EN
Four Bayesian network models (SB‑1, SB‑2a, SB‑2b, SB‑2c) for assessing reinforcement corrosion probability in concrete were compared. Seven corrosion parameters were considered: potential; resistivity; chlorides; pH; corrosion current; charge transfer resistance; cracking. Monte Carlo simulations for three threat scenarios (low, medium, high) demonstrated the superiority of model SB‑2c – highest accuracy and flexibility. Model SB‑2c was identified as optimal for corrosion diagnostics of reinforced concrete.
PL
Porównano cztery modele sieci bayesowskich (SB‑1, SB‑2a, SB‑2b, SB‑2c) oceniające prawdopodobieństwo korozji zbrojenia w betonie. Uwzględniono siedem parametrów korozyjnych: potencjał; rezystywność; chlorki; pH; prąd korozyjny; opór przeniesienia ładunku; zarysowanie. Symulacje Monte Carlo dotyczące trzech scenariuszy zagrożenia (niskie, średnie, wysokie) wykazały przewagę modelu SB‑2c – największą dokładność i elastyczność. Wskazano model SB‑2c jako optymalny w diagnostyce korozyjnej żelbetu.
EN
This article presents contemporary methods for diagnosing corrosion damage in reinforced concrete structures. The first section provides a brief overview of traditional measurement methods used to assess the corrosion risk of reinforced concrete, including tests of concrete’s protective properties against reinforcement, corrosion probability tests, and polarisation tests of the corrosion rate of reinforcement in concrete. The second part of the article describes modern digital technologies that support the diagnosis of corrosion damage, including visual inspection using mixed reality and artificial intelligence, and remote inspection using drones. Additionally, the article describes a BIM model of the diagnosed structure allowing for the creation of a digital twin. This model integrates all classical and digital diagnostic tools.
PL
W artykule przedstawiono współczesne możliwości prowadzenia zaawansowanej diagnostyki uszkodzeń korozyjnych konstrukcji żelbetowych. W pierwszej części skrótowo omówiono standardowe metody pomiarowe, od dawna stosowane w ocenie zagrożenia korozyjnego żelbetu: badania właściwości ochronnych betonu względem zbrojenia, badania prawdopodobieństwa korozji i polaryzacyjne badania szybkości korozji zbrojenia w betonie. W drugiej, zasadniczej części artykułu scharakteryzowano nowoczesne technologie cyfrowe wspierające diagnostykę uszkodzeń korozyjnych: inspekcję wizualną z użyciem technologii rzeczywistości mieszanej i sztucznej inteligencji, a także zdalną inspekcję z wykorzystaniem dronów. Jako technologię integrującą wszystkie standardowe i cyfrowe narzędzia diagnostyczne opisano model BIM diagnozowanej konstrukcji, umożliwiający stworzenie cyfrowego bliźniaka.
EN
Protective coating of reinforcement extends the period of safe use of reinforced concrete structures. However, the available literature does not present any methods for reliable evaluation of extended durability of concrete members with galvanized reinforcement compared with conventional rebars without any protection. This paper proposes a simple method of comparative evaluation of durability on the basis of corrosion current density in the function of time measured with polarization (LPR and EIS) methods. After converting distribution of corrosion current density into distribution of corrosion rate CR indicator, accumulated corrosion loss of zinc coating on a rebar was determined by numerical integration of the surface under the distribution of the CR indicator in the function of time. Then, as further corrosion rate of zinc coating was predicted until dissolution of its thinnest fragment, the extended durability of reinforced concrete member was estimated. This extended time was a result of applying the protective coating of reinforcement in the form of hot-dip galvanisation.
PL
W wyniku zastosowania ochrony powłokowej zbrojenia w konstrukcjach żelbetowych istotnie wydłuża się okres ich bezpiecznego użytkowania. W literaturze przedmiotu nie wskazuje się jednak sposobów miarodajnej oceny wzrostu trwałości elementów betonowych z ocynkowanym zbrojeniem w porównaniu z tradycyjnie wykonywanymi elementami z prętami, w wypadku których nie zastosowano żadnej ochrony. W artykule zaproponowano prosty sposób porównawczej oceny trwałości na podstawie realizowanych w funkcji czasu pomiarów gęstości prądu korozyjnego metodami polaryzacyjnymi (LPR i EIS). Po przeliczeniu rozkładów gęstości prądu korozyjnego na rozkłady wartości wskaźnika szybkości korozji CR sumaryczny ubytek korozyjny powłoki cynkowej na pręcie zbrojeniowym wyznaczono przez numeryczne całkowanie powierzchni pod rozkładem wskaźnika CR w funkcji czasu. Następnie, prognozując dalszą szybkość korozji powłoki cynkowej do momentu roztworzenia jej najcieńszego fragmentu, oszacowano czas wydłużenia trwałości elementu żelbetowego dzięki zastosowaniu ochrony powłokowej zbrojenia w formie ogniowej powłoki cynkowej.
PL
Przedstawiono propozycję uproszczonej analizy spadku nośności elementów belkowych konstrukcji stropu żelbetowego w wyniku oddziaływania agresywnego środowiska korozyjnego w kopalnianym budynku technologicznym płuczki węgla kamiennego. Podstawą analizy redukcji nośności elementów belkowych stropu były badania konstrukcji zrealizowane in situ oraz w warunkach laboratoryjnych. Wyniki badań były bardzo zróżnicowane i nie pozwoliły jednoznacznie przyjąć do obliczeń stopnia zaawansowania korozji betonu i stali. Z tego względu przeanalizowano różne możliwe poziomy destrukcji betonu i stali oraz ich wpływ na zmianę nośności elementów konstrukcji. Wariantowa analiza postępu degradacji pozwoliła ocenić stan stropu jako przedawaryjny i precyzyjnie określić sposób naprawy.
EN
The method of simplified analysis was presented for load-carrying capacity decrease of beam elements of the reinforced concrete structure as the effect of aggressive corrosion environment present in the infrastructure building for hard coal washer. The analysis of decreased load-carrying capacity of beam elements in the concrete floor was based on the tests performed on the structure in the in situ and laboratory conditions. Concrete cores cut out from the structure were subjected to strength and compressive tests, and chemical tests. Tensile testing was conducted on rebars taken from the structure. The obtained test results significantly differed and did not clarify which degree of corrosion development of concrete and steel should be used in calculations. Therefore, various levels of concrete and steel destruction and their effect on changing load-carrying capacity of the structure elements were analysed. The variant analysis of degradation development was used to evaluate the floor structure condition as the imminent failure condition and to determine the method of its repair.
PL
W artykule przedstawiono analizę przyczyn uszkodzeń płyt i ścian żelbetowych dwóch najniższych, nieużytkowanych kondygnacji, wielorodzinnego budynku mieszkalnego, nadbudowanego niezgodnie z projektem o kilka pięter. Istniało podejrzenie, że znaczne zwiększenie obciążeń nadbudową jest przyczyną powstania rys na ścianach i stropach najniższych kondygnacji. Ponadto obawiano się, że penetrująca od 25-ciu lat przez rysy woda opadowa może być przyczyną korozji betonu i stali zbrojeniowej zmniejszającej nośność elementów konstrukcji. W ramach oceny stanu konstrukcji przeprowadzono badania wytrzymałościowe betonu, pomiary układu zbrojenia oraz badania właściwości ochronnych otulenia betonowego wobec stali zbrojeniowej. Wyniki badań uwzględnione w obliczeniach numerycznych modelu konstrukcji budynku pozwoliły jednoznacznie wskazać skurcz betonu jako przyczynę pęknięć płyt i ścian żelbetowych. Wykonanie nadbudowy nie było więc przyczyną uszkodzeń konstrukcji, a beton pomimo długotrwałego oddziaływania wód opadowych nie stracił swoich właściwości mechanicznych ani ochronnych wobec zbrojenia.
EN
This article presents an analysis of damage to reinforced concrete slabs and walls in two unoccupied lowest stories of the multi-family building with a few-storey upward extension incompatible with the design. A significant increase in loading caused by that extension was supposed to cause cracks in walls and floors at the lowest stories. Moreover, rainwater penetrating cracks for 25 years was expected to induce corrosion of concrete and reinforcing steel reducing the load capacity of structural members. Strength tests, measurements of the reinforcement and tests on protective properties of concrete cover to reinforcing steel were performed as part of evaluating conditions of the structure. Test results included in numerical calculations of the structure model, provided the clear finding that concrete shrinkage was the reason for cracks in reinforced concrete slabs and walls. Thus, the upward extension did not cause damage to the structure, and concrete maintained its mechanical and protective properties to reinforcement despite the long-term effect of rainwater.
PL
W pracy przedstawiono wyniki polaryzacyjnych badań stałoprądowych wykonywanych na fragmentach prętów zbrojeniowych znajdujących się w wyciętych z konstrukcji żelbetowych rdzeniach. W pierwszym etapie badań zastosowano tradycyjny układ trzech elektrod, w którym elektrodą badaną był pręt zbrojeniowy w walcowym rdzeniu, elektrodą pomocniczą krążek blachy ze stali trudnordzewiejącej, a elektrodą odniesienia klasyczna Ag, AgCl | Clˉ w korpusie szklanym. Elektrody pomocnicza i odniesienia były przykładane do płaskiej powierzchni próbki przez wilgotną podkładkę filcową lub żel przewodzący. W drugim etapie badań zastosowano alternatywny układ elektrod, w którym elektrodą pomocniczą była powłoka lakieru z dodatkiem proszku srebra naniesiona na pobocznicę próbki, a pręt grafitowy osadzony w próbce wykorzystywano jako elektrodę odniesienia. Wyniki badań w warunkach powietrzno-suchych wykazały, że tradycyjne - elektrody przykładane do powierzchni betonu powodują duże zaburzenia wyników uniemożliwiające ich analizę, natomiast elektrody na stałe osadzone w betonie w tych samych warunkach wilgotnościowych pozwalają uzyskać zadawalające rezultaty.
EN
This article describes results from d.c. polarization measurements of rebar fragments in concrete cores drilled from a structure. In the first stage of tests, a traditional arrangement of three electrodes was applied, in which the working electrode was the rebar in a cylindrical core, the counter electrode was a stainless steel disk, and the reference electrode was a traditional Ag, AgCl | Clˉ electrode in a glass body. The counter and reference electrodes were applied to a flat surface of the specimen covered with a wet felt washer or conductive gel. In the second stage of tests, an alternative electrode setup was used, in which the reference electrode was covered with the varnish and silver powder additive present on the specimen side surface, and a graphite rod in the specimen was used as the reference electrode. Results from tests performed under dry air conditions indicated that traditional electrodes applied to concrete surface caused significant discrepancies in results, and consequently their analysis became impossible. And electrodes permanently embedded into concrete provided satisfactory results for tests under the same conditions.