Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 118

Liczba wyników na stronie
first rewind previous Strona / 6 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  energy performance
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 6 next fast forward last
EN
The article presents trends in changes in climate parameters in Poland and around the world in the context of the impact on the energy efficiency of buildings, highlighting the need for adaptive strategies to mitigate their effects. For specific climate change scenarios and technical equipment of an example building, an analysis of its energy performance was carried out. The possibility of using passive systems as an additional element integrated into the external building envelope and using solar energy was taken into account.
PL
W artykule przedstawiono trendy zmian parametrów klimatu w Polsce i na świecie oraz ich wpływ na efektywność energetyczną budynku. Podkreślono konieczność stosowania adaptacyjnych strategii mających na celu łagodzenie skutków tych zmian. Na podstawie określonych scenariuszy dotyczących zmian klimatu oraz wyposażenia technicznego przykładowego budynku przeprowadzono analizę jego charakterystyki energetycznej. Uwzględniono możliwość stosowania systemów pasywnych, które stanowią integralny element zewnętrznej obudowy budynku i wykorzystują energię promieniowania słonecznego.
PL
Wymagania prawa budowlanego w zakresie ochrony cieplnej budynków są coraz ostrzejsze, dlatego poszukiwane są rozwiązania poprawiające efektywność energetyczną nowoprojektowanych budynków. W budynkach mieszkalnych wielorodzinnych jednym z głównych systemów wpływających na charakterystykę energetyczną jest instalacja wentylacji oraz przygotowania ciepłej wody użytkowej. W artykule przedstawiono analizę wpływu systemu glikolowego odzysku ciepła z wentylacji do przygotowania ciepłej wody użytkowej na wartość wskaźnika nieodnawialnej energii pierwotnej EP dla przykładowego budynku mieszkalnego wielorodzinnego. W tym celu opisano rodzaje systemów do odzysku ciepła z powietrza wentylacyjnego, a następnie dla przykładowe go budynku mieszkalnego wielorodzinnego przeprowadzono analizę wpływu założeń instalacyjnych na wartość wskaźnika EP. Przeprowadzone analizy wykazały, że zastosowanie glikolowego odzysku ciepła z powietrza wentylacyjnego powoduje obniżenie wskaźnika EP. Jednak przy podstawowym źródłem ciepła, jakim jest kocioł gazowy, sama taka instalacja bez dodatkowych działań w postaci zwiększonej izolacyjności przewodów w instalacjach, czy zastosowaniu instalacji fotowoltaicznej produkującej energię elektryczną na miejscu, może nie wystarczyć, aby spełnić obecne wymagania w zakresie wskaźnika EP, jak dla nowo wznoszonych budynków. Artykuł ten powstał na podstawie pracy dyplomowej magisterskiej o tytule „Wykorzystanie ciepła zawartego w powietrzu usuwanym do przygotowania ciepłej wody użytkowej w budownictwie mieszkaniowym wielorodzinnym” wykonanej na Wydziale Instalacji Budowlanych, Hydrotechniki i Inżynierii Środowiska Politechniki Warszawskiej.
EN
The requirements of the building law in the field of thermal protection of buildings are becoming more stringent, which is why solutions are sought to improve the energy efficiency of newly designed buildings. In multi-family residential buildings, one of the main systems influencing the energy performance is the ventilation system and the preparation of domestic hot water. The article presents an analysis of the impact of the glycol heat recovery system from ventilation for the preparation of domestic hot water on the value of the non-renewable primary energy index EP for an example multi-family residential building. For this purpose, the types of systems for heat recovery from ventilation air were described, and then an analysis of the impact of installation assumptions on the value of the EP index was carried out for an example multi-family residential building. The analyses carried out showed that the use of glycol heat recovery from ventilation air reduces the EP index. However, with the basic heat source being a gas boiler, such an installation alone without additional measures in the form of increased insulation of pipes in installations or the use of a photovoltaic installation producing electricity on site may not be sufficient to meet the current requirements in terms of the EP index for newly constructed buildings. This article is based on the master's thesis entitled "Use of heat contained in exhaust air for preparing domestic hot water in multi-family residential building" completed at the Faculty of Building Services, Hydro and Environmental Engineering of the Warsaw University of Technology.
PL
W artykule przedstawiono problematykę termomodernizacji istniejących domów studenckich, na przykładzie akademika Politechniki Wrocławskiej, wybudowanego w 1976 r. w ramach projektu „Typowego Domu Studenckiego”, z naciskiem na analizę potencjalnych możliwości zaopatrzenia budynku w energię ze źródeł bezemisyjnych. Dodatkową uwagę poświęcono wskazaniu różnic i wynikających z tego problemów termomodernizacyjnych związanych z odmiennym, niż dla budynków mieszkalnych wielorodzinnych, sposobem użytkowania.
EN
The article presents problems of thermal modernization of existing student buildings, on the example of a dormitory of the Wrocław University of Science and Technology, which was built as part of the „Typical Student Building” project in 1976, with an emphasis on the analysis of the potential possibilities of supplying the building with energy from non-emission sources. Additional attention was paid to identifying the differences and the resulting thermal modernization problems, related to the way of use, different than for multi-family residential buildings.
5
Content available remote Potencjał dekarbonizacji zabytkowej kamienicy w Warszawie
PL
Konieczność zmniejszenia udziału budownictwa w ogólnym zapotrzebowaniu na nieodnawialną energię pierwotną i minimalizacji emisji dwutlenku węgla na etapie eksploatacji budynków wymusza opracowanie planu termomodernizacji i dekarbonizacji budynków. Proces ten wymaga jednak szczególnego planowania w przypadku obiektów zabytkowych. W artykule przeprowadzono analizę stanu istniejącego i opracowano dwa warianty termomodernizacji jednej z przedwojennych, zabytkowych kamienic warszawskich przy ulicy Kopernika 23. Sprawdzono, jak zmiany w budynku mogą wpłynąć na jego efektywność energetyczną oraz emisję CO2 i innych szkodliwych substancji, a także poprawę komfortu użytkowania budynków. Głównym założeniem było zmniejszenie zapotrzebowania na nieodnawialną energię pierwotną oraz zminimalizowanie emisji CO2. W przedstawionych propozycjach wzięto również pod uwagę architekturę budynku i jego otoczenie.
EN
The need to reduce the share of construction in the overall demand for non-renewable primary energy and to minimize carbon dioxide emissions during the operation stage of buildings requires the development of a plan for renovation and decarbonization of buildings. However, this process requires special planning for historic buildings. The article analyzes the existing state and develops two variants of renovation of one of Warsaw's pre-war historic apartment buildings at 23 Kopernika St. It examines how changes to the building can affect its energy efficiency and emissions of CO2 and other pollutants, as well as improve indoor comfort. The main goal was to reduce the demand for non-renewable primary energy and minimize CO2 emissions. The proposed solutions also took into account buildings architecture and surroundings.
PL
W artykule przedstawiono analizę proponowanych zmian w zakresie opracowywania charakterystyki energetycznej budynku lub części budynku.
EN
The article presents an analysis of the proposed changes in the scope of developing the energy performance of a building or part of a building.
PL
W artykule przedstawiono ogólne zasady opracowywania świadectw charakterystyki energetycznej budynku. Opisano podstawowe wskaźniki w zakresie oszczędności energii w budynkach, a także planowane zmiany do rozporządzenia w sprawie metodologii wyznaczania charakterystyki energetycznej budynku lub części budynku oraz świadectw charakterystyki energetycznej.
EN
The article presents general principles for developing building energy performance certificates. Basic indicators for energy savings in buildings are described, as well as planned changes to the regulation on the methodology for determining the energy performance of a building or parts of a building and energy performance certificates.
EN
Algeria is a country that has witnessed rapid development as a result of its abundant oil supplies. The country’s GDP to energy consumption ratio clearly shows the need to adopt energy efficiency policies. Taking into account the regulation of excess solar radiation in the desert environment, this study examines the relationship between the shape of different buildings and their energy use. This research was divided into two stages. In the first stage, the ideal building shape for the city of Adrar, in terms of energy consumption, was determined by studying three basic geometric shapes, including square, rectangular, and triangle shapes. According to simulation research conducted using Design Builder (version 6.1.0), a square building was the best shape to maximize energy performance. To analyze the thermal behavior of different building shapes, all structures with expanded shapes were simulated based on the ideal shape discovered in the first stage. Of the three extended alternative cases, the case of the Mini Arrival offers the best energy efficiency and sufficient natural lighting thanks to its 90 cm depth and no vertical offset from the top of the window. By adding design principles to the design process, this study helps improve the energy efficiency of new buildings and also gives another angle on research methods for solving energy performance issues regarding desert buildings.
EN
In contemporary literature, there are not many analyses taking into account changing heat transfer coefficients over the years and examining and comparing the variability of insulation thickness in different thermal standards. The article presents the evolution of energy demand taking into account the requirements of the Green Deal. The analysis was carried out using two materials, showing how their thickness changed in relation to the evolving energy requirements. The research was illustrated with an example of thermal modernization for a building in specific time periods. The analysis was carried out using a numerical program, comparing warming variants for individual years using the Index of annual primary energy demand. Following the requirements contained in the EPDB directive, a comprehensive reduction of the penetration coefficients for building partitions was proposed and requirements for the mandatory use of mechanical ventilation and photovoltaics were introduced.
PL
W artykule omówiono znaczenie narzędzi obliczeniowych wykorzystywanych w analizie bilansu energetycznego budynków, ze szczególnym uwzględnieniem wpływu wykorzystania oświetlenia naturalnego. Zwrócono uwagę na współzależności występujące pomiędzy czynnikami wpływającymi na kształtowanie się zapotrzebowania na ciepło, chłód, oraz energię do oświetlenia. Przedstawione w artykule wyniki obliczeń wykazały, że obliczony bilans energetyczny budynku może w znacznej mierze zależeć od wykorzystanych narzędzi obliczeniowych. Podkreślono, że przypadku wykorzystania oświetlenia naturalnego, dostęp do światła słonecznego jest uzależniony od wielu czynników, zatem zakres, oraz sposób ich uwzględnienia w modelu obliczeniowym ma istotne znaczenia dla dokładności otrzymywanych wyników.
EN
The article discusses the importance of calculation tools used for analysis of the energy balance of buildings, with particular emphasis on the impact of the use of daylight. It was highlighted that there are interdependencies between factors that shape the energy demand for heat, cooling, lighting. The calculation results presented in the article indicate that calculated energy balance of a building may depend to a large extent on the calculation tools used. It was pointed out that in the case of the use of daylight, access to sunlight depends on a number of factors, therefore the way they are included in the computational model is are important for the accuracy of the results.
PL
Budynki jednorodzinne stanowią znaczną część sektora mieszkaniowego w Polsce. Wiele z nich cechuje się niską efektywność energetyczną i będzie wymagać termomodernizacji w nadchodzących latach. W publikacji przeanalizowano możliwości zastosowania odnawialnych źródeł energii cieplnej i elektrycznej w celu poprawy charakterystyki energetycznej rzeczywistego budynku jednorodzinnego. Analizy uwzględniły różne rozwiązania źródeł energii z wykorzystaniem pompy ciepła powietrznej i gruntowej, kolektorów słonecznych, grzałki elektrycznej, istniejącego kotła gazowego oraz instalacji fotowoltaicznej. Przeprowadzono wielowariantową ocenę popularnych konfiguracji źródeł ciepła w celu określenia jaki wpływ na redukcję wartości wskaźnika nieodnawialnej energii pierwotnej EP mają: rodzaj i ekspozycja kolektorów słonecznych, rodzaj pompy ciepła, rodzaj źródła szczytowego w systemie biwalentnym z pompą ciepła, dobór przewymiarowanej pompy ciepła oraz doposażenie instalacji powietrznej pompy ciepła o kolektory słoneczne. Najniższą wartość wskaźnika EP  =  38 kWh/(m2∙rok) i jednostkową emisję CO2 równą 150 kg/rok uzyskano dla wariantu, w którym istniejącą kotłownię gazową doposażono o pompę ciepła powietrzną i instalację fotowoltaiczną. Analizy zostały przeprowadzone z wykorzystaniem oprogramowania przeznaczonego do obliczeń energetycznych, IDA ICE.
EN
Single-family buildings constitute a significant part of the housing sector in Poland. Many of them are characterized by low energy efficiency and will require retrofitting in the coming years. The publication analyzed the possibilities of using renewable energy sources to improve the thermal characteristics of a real single-family building. The calculations took into account various solutions of energy sources installations including an air and ground source heat pump, solar thermal collectors, an electric heater, an existing gas boiler and a photovoltaic installation. A multi-variant analysis was conducted on popular configurations of thermal energy sources to assess how the reduction of the non-renewable primary energy index (EP) was influenced by factors such as the type and exposure of solar collectors, the type of heat pump, the type of top-up heat source in a bivalent system with a heat pump, the selection of an oversized heat pump, the integration of solar collectors into the air source heat pump installation. The lowest value of EP  =  38 kWh/(m2∙year) and CO2 emission of 150 kg/year were obtained for the variant in which the existing gas boiler room was retrofitted with an air heat pump and a photovoltaic installation. The analyzes were performed with the use of dedicated software for energy calculations, IDA ICE
EN
The article presents an analysis of the impact that meeting LEED certification criteria has on the calculated energy performance of a building based on Polish regulations regarding the methodology for determining the energy performance of a building, taking into account the technical modernization that affects the final result of the analysis. Calculations were carried out on the example of an office building. The analysis covered a scope that combines LEED certification and energy performance, such as water use and indoor lighting. The calculations were made in a program designed for energy performance calculations. The use of energy-saving lamps (46% lower energy use in relation to standard lamps) or fittings limiting the water flow from the tap (26% lower water use) did have a positive impact on the final calculation of post-modification energy performance, according to which the demand for primary energy was reduced by 36%. The static analysis was performed using commercial software for preparing energy performance certificates and on the basis of formal guidelines set out by the LEED certification.
XX
W artykule przedstawiono analizę wpływu certyfikacji LEED (Leadership in Energy and Environmental Design) na obliczenia charakterystyki energetycznej budynku w oparciu o polskie przepisy dotyczące metodologii wyznaczania charakterystyki energetycznej budynku z uwzględnieniem modernizacji technicznych, które mają wpływ na wynik końcowy analizy. Obliczenia przeprowadzono dla budynku biurowego. Analiza obejmowała zakres, który łączy certyfikację LEED, taki jak wykorzystanie wody i oświetlenie wewnętrzne, oraz charakterystykę energetyczną. Obliczenia wykonano w programie przeznaczonym do obliczeń charakterystyki energetycznej. Zastosowanie energooszczędnych lamp (redukcja zapotrzebowania na energię o 46% w odniesieniu do standardowych lamp) czy też armatury ograniczającej wypływ wody z baterii (redukcja o 26%) potrafi korzystnie wpłynąć na ostateczny wynik charakterystyki energetycznej, gdzie zapotrzebowanie na energię pierwotną po wprowadzeniu modyfikacji zmniejszyło się o 36%. Analizę statyczną wykonano za pomocą programu komercyjnego do sporządzania świadectw charakterystyki energetycznej oraz na podstawie wytycznych formalnych stawianych przez certyfikację LEED.
PL
Niniejszy artykuł porusza tematykę wzajemnej korelacji funkcji oraz formy współczesnej architektury z uwarunkowaniami i potencjałem energetycznym nowoczesnych technologii wyposażenia budynku. W pracy przedstawiono wstęp do dalszych interdyscyplinarnych badań mających na celu określenie potencjału budynku Wydziału Architektury i Wydziału Inżynierii Zarządzania jako obiektu wspierającego pracę energetyczną całego kampusu Politechniki Poznańskiej zlokalizowanego bezpośrednio przy rzece Warta w Poznaniu.
EN
This article discusses the mutual corelation of function and form of contemporary architecture with energy conditions and potential of new technologies in buildings. The article presents an introduction to further interdisciplinary research aiming at defining the potential of the building of the Faculty of Architecture and Engineering Management as a facility supporting energy performance of the whole campus of the University of Technology located directly by the Warta river in Poznań.
PL
W artykule dokonano oceny efektywności energetycznej wybranych rozwiązań systemów HVAC w projektowanym budynku hotelowym. Analizie poddano wybrane warianty instalacji centralnego ogrzewania, klimatyzacji oraz wentylacji w aspekcie spełniania wymagań WT 2021, w tym pod względem wykorzystania odnawialnych źródeł energii i ich wpływu na wartość wskaźnika energii pierwotnej EP. Dla wariantów spełniających wymagania WT 2021 przeprowadzono analizę ekonomiczną obejmującą koszty inwestycyjne oraz eksploatacyjne.
EN
The article evaluates the energy efficiency of selected design solutions for HVAC systems in the designed hotel building. Selected variants of central heating, air conditioning and ventilation installations were analyzed in terms of meeting the requirements of Polish building codes WT 2021, including the use of renewable energy sources and their impact on the value of the primary energy index EP. For variants meeting the requirements of WT 2021, an economic analysis was carried out, including investment and operating costs.
PL
Zgodnie z obowiązującymi przepisami budowlanymi [i] konieczne jest stosowanie przegród budowlanych o wysokiej izolacyjności cieplnej (spełnienie wymagania Umax ) oraz jednoczesne zapewnienie niskich wartości wskaźnika zapotrzebowania na nieodnawialną energię pierwotną (spełnienie wymagania EPmax ). Osiągnięcie odpowiednio niskiego wskaźnika EP zależy od wielu zmiennych, związanych zarówno z rozwiązaniami architektoniczno-budowlanymi, jak i systemami technicznego wyposażenia budynku, w szczególności ogrzewania, chłodzenia, wentylacji i przygotowania cieplej wody użytkowej. Możliwe są różne kombinacje ich wzajemnej konfiguracji. W artykule zaprezentowano metodę ustalania zestawu rozwiązań architektoniczno-instalacyjnych pozwalających spełnić kryterium EPmax dla budynków mieszkalnych wielorodzinnych z wentylacją naturalną lub hybrydową. Pozwala ona w prosty sposób określić, jakie systemy technicznego wyposażenia budynku należy zastosować, by dla danego rozwiązania architektonicznego uzyskać wymaganą wartość wskaźnika EP, lub jak zmodyfikować rozwiązanie architektoniczne przy zastosowaniu danego systemu HVAC i c.w.u. Metoda ta jest uniwersalna - można ją zastosować do przeprowadzenia podobnej analizy przy wykorzystaniu innej metodologii obliczeń charakterystyki energetycznej budynku.
EN
According to the current building regulations [1] it is necessary to use building envelope with good thermal insulation (meeting the Umax requirement) and at the same time ensuring low values of non-renewable primary energy consumption (meeting the PEmax requirement). Achieving a sufficiently low PE indicator depends on many variables, related to both architectural solutions and building technical systems, in particular heating, cooling, ventilation and domestic hot water. Various configurations of architectural and HVAC design parameters are possible. The article presents a method for determining a set of solutions which meet the PEmax criterion for multifamily buildings with natural ventilation or hybrid ventilation. Presented approach allows to easily determine which systems should be used to achieve the required value of the PE index for a given architectural solution, or how to modify the architectural solution with the use of a given HVAC and DHW system. This method is universal - it can be used to carry out a similar analysis using a different methodology for calculating the energy performance of the building.
PL
Szczególnym rodzajem obiektów zabytkowych są obiekty militarne, gdyż ich charakter i pełniona niegdyś funkcja znacznie różnią się od tej, którą chce się im nadać, aby przywrócić do użytkowania. W artykule przedstawiono koncepcję architektoniczną rewitalizacji i termomodernizacji Fortów Bema w Warszawie z wariantową koncepcją modernizacji źródła ciepła, dostosowaną do specyficznej formy, zabytkowego charakteru i realnych możliwości. Przedstawiono obliczenia zapotrzebowania na energię i emisję dwutlenku węgla podczas eksploatacji we wszystkich zaproponowanych wariantach. Obliczenia pokazują możliwości przywrócenia obiektu społeczności lokalnej, poprawy komfortu jego użytkowania w wyniku poprawy parametrów obudowy zewnętrznej oraz możliwości obniżenia zapotrzebowania na energię i osiągnięcie standardu budynku zero emisyjnego.
EN
Military buildings are a special type of historic building, as their character and the function they used to provide are very different from the functions you want to give them in order to be returned to their users. This article presents an architectural concept for the thermal modernisation of the Bema Fort in Warsaw with a variant concept for the modernisation of the heat source, adapted to the specific form, historic character and realistic possibilities. Calculations of energy demand and carbon dioxide emissions during operation in all proposed variants are presented. The calculations show the possibilities of restoring the facility to the local community, improving the comfort of its use related to the upgrade of its external envelope parameters and the possibilities of lowering its energy demand and achieving a zero-emission building standard.
PL
System świadectw charakterystyki energetycznej jest ważnym elementem sektora budynków i kształtowania polityki energetycznej w Unii Europejskiej. W Polsce system ten działa już od niemal piętnastu lat bez większych zmian. Implementacja wymagań zmienianych dyrektyw w sprawie charakterystyki energetycznej budynków jest dobrym momentem na rewizję stanu obecnego i zaproponowanie ewentualnych zmian w całym systemie. W artykule przedstawiono proponowane zmiany dotyczące generalnych aspektów systemu świadectw charakterystyki energetycznej budynków przedstawione w projekcie rozporządzenia w sprawie metodologii sporządzania świadectw. Zmiany te dotyczą: stosowanych metod obliczeniowych, nowego rodzaju w klasyfikacji energii, usankcjonowania uwzględniania w obliczeniach kominka na biomasę jako źródła ciepła, przyjmowania domyślnych współczynników nakładu nieodnawialnej energii pierwotnej dla ciepła sieciowego, wprowadzenia nowych wskaźników środowiskowych, prezentacji wyników charakterystyki energetycznej w postaci klas energetycznych czy samego wzoru świadectwa charakterystyki energetycznej. Wszystkie zaproponowane zmiany mają nie tylko dostosować obowiązujące przepisy do nowych norm i wymagań dyrektyw EPBD, ale głównie mają poprawić odbiór i zrozumienie świadectw przez odbiorców końcowych.
EN
The energy performance certificate system is an important element of the buildings sector and energy policy-making in the European Union. In Poland, this system has been operating for almost fifteen years without major changes. The implementation of the requirements of the amended directives on the energy performance of buildings is a good time to review the current state and propose possible changes to the entire system. The article presents proposed changes regarding general aspects of the system of energy performance certificates for buildings presented in the draft regulation on the methodology for preparing certificates. These changes concern: the applied computational methods, a new type in energy classification, the sanctioning of considering biomass fireplace as a heat source in calculations, the acceptance of default coefficients for non-renewable primary energy input for district heating, the introduction of new environmental indicators, the presentation of results of energy performance in the form of energy classes or the energy performance certificate template itself. All proposed changes are intended not only to adapt the applicable regulations to the new standards and requirements of the EPBD directives, but mainly to improve the reception and understanding of certificates by end recipients.
EN
Improving the energy performance of buildings has thus become a major challenge, as the building sector is now one of the main sources of energy consumption and one of the main contributors to greenhouse gas emissions. Faced with these alarming challenges, current building design in the north is based on minimizing heat loss. However, this logic is not necessarily the most relevant in southern countries, characterized by excessive heat and insufficient, variable rainfall. The best way to achieve this is through sustainable design, with its intrinsic, energy_saving qualities, exploited by effective modeling. This article focuses on ideas and innovations that are helping to overcome these challenges. The results of introducing a porch into building design represent best practice in arid zones and beyond in terms of how it is thermally insulated. This has resulted in a significant reduction in thermal load in the energy ratio of up to 53.55%. This latest research aims to provide construction professionals with concrete examples of the design process, its technical feasibility, optimization and digitization based on climatic data from the arid zone.
20
Content available remote Wyzwania świadomego wyznaczania charakterystyki energetycznej budynku
PL
Przedstawiono wybrane problemy wynikające z analizy obowiązujących, uchylonych oraz zmienionych przepisów dotyczących charakterystyki energetycznej budynków w Polsce. Poruszono te, wynikające z niejasności i braków w obowiązującej metodyce, ze wskazaniem wpływu części z nich na wynik obliczeń charakterystyki energetycznej budynku oraz przedstawiono wybrane sugestie dotyczących zmian zasad wyznaczania charakterystyki energetycznej. Zaprezentowano spojrzenie z perspektywy osoby sporządzającej charakterystykę energetyczną
EN
Selected problems resulting from the analysis of the current, repealed and amended regulations on the energy performance of buildings in Poland are presented. Those resulting from ambiguities and deficiencies in the current methodology were addressed, with an indication of the impact of some of them on the outcome of the calculation of the energy performance of the building, as well as selected suggestions for changes in the rules for determining energy performance were presented. A view from the perspective of the person drawing up the energy performance was presented
first rewind previous Strona / 6 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.