The paper presents the test results of pool boiling heat transfer on the rough surface and the surface covered with capillary – porous microstructure. The porous layer is made of copper fibers sintered in the reduction atmosphere. The volumetric porosity amounted to 68%, while its height 1 mm. Distilled water and ethyl alcohol were used as the working fluids. The experiments have been carried out under the atmospheric pressure. Enhancement of heat transfer in relation to the smooth reference surface has been recorded especially for the low range of superheats, which might be related to the density of active nucleation sites. Experimental results have been compared with selected models of boiling available in literature.
PL
Artykuł przedstawia wyniki badań wymiany ciepła przy wrzeniu na powierzchniach chropowatych i z porowatym pokryciem metalowo-włóknistym. Mikrostruktura porowata została wykonana z włókien miedzianych spiekanych w atmosferze redukcyjnej. Porowatość objętościowa wynosi 68%, a wysokość warstwy 1 mm. Badania prowadzono dla wody destylowanej i alkoholu etylowego jako cieczy wrzących pod ciśnieniem atmosferycznym. Zaobserwowano intensyfikację wymiany ciepła w porównaniu do powierzchni gładkiej, szczególnie w zakresie małych przegrzań, co może być związane z gęstością aktywnych centrów nukleacji. Wyniki badań eksperymentalnych porównano z wybranymi modelami wrzenia dla danych powierzchni.
PL
Z biomechanicznego punktu widzenia właściwa współpraca elementów tworzących połączenie kości (naturalnego materiału porowatego) z porowatym implantem warunkowana jest m.in. porodostępnością porowatej warstwy pokrywającej implant dla adaptacyjnego wrastania w nią tkanki kostnej. Przez porodostępność należy rozumieć zdolność przestrzeni porów porowatej warstwy pokrywającej implant, do przyjęcia wrastającej w nią tkanki kostnej i utworzenia w ten sposób funkcjonalnego biomechanicznie połączenia porowaty implant-kość, co warunkowane jest wypełnieniem przestrzeni tych porów zmineralizowaną tkanką kostną. Przedstawiono sposób stereometrycznej oceny strukturalno-osteoindukcyjnych właściwości porowatych pokryć implantów dokostnych mocowanych bezcementowo. Zestaw parametrów, tzw. parametrów porodostępności [8, 16, 20], których wartości można wyznaczyć dokonując analizy struktury geometrycznej powierzchni w układzie 3D [9, 12] porowatych pokryć, umożliwia przeprowadzenie oceny właściwości, które cechują zdolność przestrzeni porowej porowatych pokryć implantów do przyjęcia wrastającej w nią tkanki kostnej i - w następstwie - utworzenia połączenia porowaty implant-kość.
EN
Presented is a method of three dimensional appraisal of the structural and osteoinductive properties of the bone graft coating materials when applied by means of non-cemented procedure.
PL
Metalowe, włókniste struktury porowate powodują, znaczną intensyfikację wymiany ciepia przy wrzeniu. W pracy przedstawiono wyniki badań wymiany ciepła w miedzianych, włóknistych strukturach kapilarno-porowatych, pokrywających powierzchnie grzejne. W procesie wrzenia występuje silna zależność współczynnika przejmowania ciepła od parametrów struktury (porowatość, grubość) pokrywającej powierzchnię. Badania wizualizacyjne są koniecznym uzupełnieniem podstawowych badań wymiany ciepła w strukturach kapilarno-porowatych. Pozwalają one na obserwację i analizę zjawisk towarzyszących wzrostowi strumienia ciepła, jak powstanie i odrywanie się pęcherzy pary.
EN
Metal fibrous porous structures cause considerable heat transfer intensification in boiling. The experimental result? dealing with heat transfer in copper fibrous capillary-porous structures covering heat surfaces are presented in the paper. In boiling process a strong dependence between heat transfer coefficient and a structure of covering surface (porosity, thickness) is observed. Visualization tests are necessary in basic investigation of heat transfer in capillary-porous structures. These tests enable one to observe and analyse phenomena accompanying the increase of heat flux such as generation and detachment of vapour bubbles.
PL
W pracy przedstawiono wyniki badań wymiany ciepła przy zastosowaniu miedzianych, włóknistych struktur kapilarno-porowatych, pokrywających powierzchnie grzejne. Metalowe, włókniste pokrycia porowate powodują znaczną intensyfikację wymiany ciepła przy wrzeniu. Przedstawiono wyniki badań eksperymentalnych wpływu porowatości i grubości struktury na wymianę ciepła przy wrzeniu w dużej objętości wody, etanolu i freonu 113. Zaobserwowano silną zależność współczynnika przejmowania ciepła od parametrów struktury. Opisano zjawisko histerezy wymiany ciepła, ograniczające obszar zastosowań pokryć porowatych.
EN
The paper presents results of investigations into heat transfer, in which copper fibrous capillary-porous structures covered heating surfaces. Metal fibrous porous structures yielded significant boiling heat transfer enhancement. Experimental investigations dealt with the impact of the structure porosity and thickness on heat transfer in water, ethanol and freon 113 pool boiling. Heat transfer coefficient showed strong dependence on the structure parameters. Heat transfer hysteresis phenomenon, restricting the application range of porous coverings, was described.
PL
Przedstawiono rozwiązanie numeryczne zagadnienia dwuwymiarowego rozkładu temperatury w przekroju żebra z pokryciem porowatym, z uwzględnieniem zmienności współczynnika przejmowania wzdłuż wysokości żebra oraz dla porównania, uproszczone rozwiązania jednowymiarowe, przy założeniu stałego współczynnika przejmowania ciepła wzdłuż wysokości żebra. Opisano specjalne stanowisko do określania rozkładu temperatur, za pomocą kamery termowizyjnej, w przekroju żebra z pokryciem kapilarno-porowatym, które przekazuje ciepło do wrzącej wody lub freonu 113. Określono pole temperatur dla obszaru składającego się z dwóch warstw o różnej przewodności cieplnej: miedzianego rdzenia i warstwy porowatej, nasączonej wrzącą cieczą. Porównano wyznaczony numerycznie rozkład temperatury w przekroju żebra ( z warunkami brzegowymi III rodzaju) z rozkładem zmierzonym przy użyciu kamery termowizyjnej.
EN
Temperature field for two-layer fin, composed of copper core and porous covering, filled with boiling fluid, was calculated. The heat transfer coefficient was assumed to way withpower-law-type formula. This solution was compared with simplified one-dimension solution. Temperature distribution in a fin vertical section was determined experimentally by infrared camera. A quite reasonable degree of agreement was found between the theory and the experimental carried out in practice.