Purpose: The aim of this paper is to examine the multifaceted field of deep thermomodernization of the 11-storey hotel building located in Bialystok, with an emphasis on unraveling the complex interaction between energy efficiency and economic considerations. Design/methodology/approach: Today, there are several methods used to gauge the most effective ways of cutting energy demand, including Simply Pay Back Time (SPBT), Pay Back Time (PBT), Net Present Value (NPV), Net Present Value Ratio (NPVR), Internal Rate of Return (IRR), and Dynamic Pay Back Time (DPBT). In Poland, studies mostly based on SPBT due to its precision and accuracy, which offers clearer and more reliable outcomes compared to other methods. However, combining multiple methods can enhance result clarity and reliability even further. During examination, we initially used SPBT to assess the impacts of energy- saving measures, resulting in clear and dependable insights into efficiency improvements. Findings: Total energy gain after deep thermomodernization is 42%. It shows that after the implementation of deep thermomodernization, annual heating expenditures were reduced by almost half (by 41%). The simple payback time (SPBT) for individual thermal modernization projects ranged from 4,32 years for external walls to 15,41 years for external doors and 13.74 years for ventilated flat roof and 10,34 for windows. Practical implications: Our research efforts have made our building more durable and valuable. Additionally, we have economized our building by minimizing energy consumption and reducing annual heating costs as much as possible. Social implications: Deep thermomodernization can reduce energy costs, increase environmental awareness, and improve quality of life by increasing society's energy efficiency. This can reinforce a sense of social responsibility and shape environmental policies. Change can be achieved in the industry by encouraging it through public policy. Originality/value: Research has shown that as technology advances, it should also be reflected in the construction sector. Instead of demolishing old buildings and rebuilding, which is costly and environmentally unfriendly, deep thermomodernization offers a more economical and eco- friendly solution for renovation. Calculations and comparisons have pointed to its effectiveness.
W artykule przedstawiono i porównano różne sposoby magazynowania energii elektrycznej, wskazując ich główne zalety, wady i ograniczenia. Przeanalizowano koszty związane z magazynowaniem energii. Omówiono kryteria doboru odpowiedniego magazynu energii w zależności od zastosowania, uwzględniając zarówno aspekty techniczne, jak i ekonomiczne. Przedstawiono również zestawienie mocy zainstalowanej w magazynach energii w Polsce i na świecie.
EN
The paper presents and compares different methods of storing electricity, pointing out their main advantages, disadvantages and limitations. The costs associated With energy storage were analyzed. The criteria for selecting the appropriate energy storage depending on the application were discussed, taking into account both technical and economic aspects. A summary of installed energy storage power in Poland and around the world is also presented.
Niniejsze opracowanie przedstawia możliwość zastosowania technologii opartych na ogniwach fotowoltaicznych wspartych magazynem energii, które mogą posłużyć do zasilania energią elektryczną elementów infrastruktury drogowej. Analiza przeprowadzona została dla istniejącego węzła drogowego, którego odbiorem energii elektrycznej jest instalacja oświetlenia drogowego. Autor scharakteryzował obiekt, określił parametry sieci zasilającej oraz przedstawił profil odbiorcy. W artykule przedstawiono możliwości zastosowania instalacji PV z magazynem energii wraz z określeniem ich wielkości. Dla danego przykładu wskazano wymagania formalno-prawne oraz dokonano oceny efektywności ekonomicznej inwestycji.
EN
This paper presents the possibility of using technologies based on photovoltaic cells supported by energy storage, which can be used to power road infrastructure elements with electricity. The analysis was carried out for an existing road junction in which the electricity recipient is the road lighting installation. The author characterises the facility, specifies the parameters of the power supply network and presents the recipient’s profile. The article presents the possibilities of using PV installations with energy storage and specifies their size. For a given example, formal and legal requirements are indicated and the economic effectiveness of the investment is assessed.
Niniejsze opracowanie przedstawia możliwość zastosowania technologii opartych na ogniwach fotowoltaicznych wspartych magazynem energii, które mogą posłużyć do zasilania energią elektryczną elementów infrastruktury drogowej. Analiza została przeprowadzona dla istniejącego węzła drogowego, którego odbiorem energii elektrycznej jest instalacja oświetlenia drogowego. Autor scharakteryzował obiekt, określił parametry sieci zasilającej oraz przedstawił profil odbiorcy. W artykule przedstawiono możliwości zastosowania instalacji PV z magazynem energii wraz z określeniem ich wielkości. Dla danego przykładu wskazano wymagania formalno-prawne oraz dokonano oceny efektywności ekonomicznej inwestycji.
EN
This paper presents the possibility of using technologies based on photovoltaic cells supported by energy storage, which can be used to power road infrastructure elements with electricity. The analysis was carried out for an existing road junction in which the electricity recipient is the road lighting installation. The author characterises the facility, specifies the parameters of the power supply network and presents the recipient’s profile. The article presents the possibilities of using PV installations with energy storage and specifies their size. For a given example, formal and legal requirements are indicated and the economic effectiveness of the investment is assessed.
Zadaniem Krajowego Systemu Elektroenergetycznego (KSE) jest zapewnienie odpowiednio wysokich i dyspozycyjnych dostaw energii elektrycznej w warunkach odchodzenia od węgla i innych paliw kopalnych. Obecnie w Polsce nastąpił znaczący wzrost mocy wytwórczych w obszarze fotowoltaiki (PV) i farm wiatrowych (FW), dzięki czemu udział tych OZE w wytwarzaniu energii istotnie wzrósł. Jednak te OZE nie są w pełni dyspozycyjne, co powoduje, że dla bezpieczeństwa KSE potrzebna jest moc zainstalowana w źródłach o wysokiej dyspozycyjności, którymi są klasyczne elektrownie oparte na spalaniu paliw oraz jądrowe. Dopóki zdolność magazynowania energii nie osiągnie poziomu zapewniającego bezpieczeństwo KSE, to zarówno PV jak i FW muszą być wspierane przez te elektrownie. Nie ma przy tym znaczenia wielkość mocy zainstalowanej w tych OZE, skoro nie jest ona w stanie zapewnić pełnej dyspozycyjności dostaw energii w ciągu roku. Natomiast energia wytwarzana w elektrowniach na paliwa kopalne nie jest zielona – jej ślad węglowy jest nieakceptowalny. Dopóki nie pojawią się w Polsce elektrownie jądrowe, jedynym źródłem odnawialnym spełniającym kryterium pełnej dyspozycyjności są elektrownie na biomasę. Przy czym nie powinna to być biomasa leśna, ponieważ jej szersze wykorzystanie obniża zdolność absorbcji CO2 przez lasy. Pozostaje więc biomasa Agro specjalnie produkowana na cele energetyczne, również na gruntach o małej bonitacji. W artykule przeanalizowano możliwość suplementacji polskiego KSE wykorzystaniem energii z biomasy Agro wskazując, że nadmierny rozwój PV i FW nie tylko generuje duże koszty, ale doprowadzi do zapaści w dostawach energii w okresie przed uruchomieniem źródeł jądrowych. Alternatywą jest konieczność dalszego spalania paliw kopalnych w elektrowniach, co trudno zaakceptować zarówno ze względów ekologicznych, jak i ekonomicznych.
EN
The task of the National Power System (NPS) is to ensure sufficiently high and available electricity supplies in the transition period of abandoning coal and other fossil fuels. Currently, in Poland there has been a significant growth in generating capacity in photovoltaics (PV) and in wind farms (WF), thanks to which the share of these renewable energy sources (RES) in energy generation has significantly increased. However, these RES are not fully available, which means that for the security of the NPS, still the capacity installed in high-availability sources, such as classic fuel-burning and nuclear power plants, is needed. Until the energy storage capacity reaches a level that ensures the security of the NPS, both PV and WF must be supported by these thermal power plants. Consequently, the amount of capacity installed in these RES is irrelevant, as it is not able to ensure full availability of energy supplies throughout the year. However, energy produced in fossil fuel power plants is not green – its carbon footprint is unacceptable. Until nuclear power plants appear in Poland, the only renewable source that meets the criterion of full availability are biomass power plants. However, they should not be fueled with forestry biomass, since its wider use reduces the intrinsic CO2 absorption capacity of the forests. What remains at our disposal is Agro biomass produced specifically for energy purposes, preferably on land of low quality. This work analyzes the possibility of supplementing the Polish NPS with energy from Agro biomass, pointing out that excessive development of PV and WF not only generates high costs, but also will lead to a collapse in energy supplies in the period before the launch of nuclear sources. The alternative is the need to continue burning fossil fuels in power plants, which is difficult to accept for both ecological and economic reasons.
W artykule odpowiedziano na bardzo istotne pytanie: czy bilans egzergii procesu energetycznego zmienia wyniki jego analizy opłacalności ekonomicznej, gdy będzie ona bazowała nie na bilansie energii, a właśnie na bilansie egzergii? Odpowiedź na powyższe pytanie jest dlatego tak bardzo istotna, gdyż autor artykułu relatywnie często spotyka się z opinią, że właśnie tak jest, co jest oczywistym nonsensem. Nonsens ten zapewne wynika z faktu, że w literaturze przedmiotu: podręcznikach, monografiach i publikacjach naukowych dotyczących termodynamiki, bilanse egzergii i energii są zawsze traktowane i przedstawiane jako „osobne byty”, gdy tymczasem tak nie jest. Bilans energii jest bowiem wyłącznie szczególnym przypadkiem bilansu egzergii, który to bilans jest nie tylko zapisem bilansu energii, ale dodatkowo jeszcze dwóch praw: prawa mówiącego o możliwym kierunku zachodzenia w układzie cieplnym procesów termodynamicznych oraz prawa mówiącego o stracie mocy w silniku cieplnym lub wzrostu mocy napędowej cieplnych maszyn roboczych (ziębiarek i pomp ciepła) na skutek nieodwracalności zachodzących w nich zjawisk. Należy zatem kolejny raz z całą mocą podkreślić, że z bilansu egzergii otrzymuje się bilans energii, że bilans energii jest pochodnym bilansu egzergii, a nie odwrotnie (sic!). To bilans egzergii jest ogólnym zapisem zjawisk zachodzących w przyrodzie, w którym zapisany jest także bilans energii. Prawda ta została expressis verbis udowodniona w niniejszym artykule. A więc czyż to nie zasada dewaluacji energii i wzrostu entropii nie powinna być najważniejszą i pierwszą zasadą termodynamiki? Czyż zatem nie należałoby przedefiniować fundamentalnych praw termodynamiki?
EN
Answered is here a very essential question whether the egzergy balance of an energy proces changes results of its cost-effectiveness analysis when this analysis is based not on the energy balance but on the egzergy one? The answer to the above question is so important because the author of this article often meets the opinion that this is exactly so which is an evident nonsense. This nonsense undoubtly results from the fact that in the subject literature i.e. in handbooks, monographs and scientific publications concerning thermodynamics, the balances of egzergy and energy are always treated and presented as „separate entities” while it is not so. The energy balance is just an exclusive case of the egzergy balance which is not only a record of the energy balance but also of some two more laws – the one saying about the possible course direction of thermodynamic processes occurring in a thermal system and the other one saying about power loss in a heat engine or growth of driving power of heat working machinery (coolers and heat pumps) because of the irreversibility of phenomena occurring in them. Then it should be once again forcefully emphasized that it is the energy balance that is obtained from the egzergy balance and that the energy balance is the egzergy balance derivative and not vice versa (sic!). It is the egzergy balance that is a general record of all phenomena occurring in nature where the energy balance is also registered. This truth has been expressis verbis proved in this article. So, should it not the principle of energy devaluation and entropy increase be the most important and the first law of thermodynamics? Why, should not then the fundamental laws of thermodynamics be redefined?
Structural and economic analysis of changes in design and construction parameters of sections of urban railway stations is conducted. Station I2 of line 2 of Mashhad, Khorasan Razavi, Iran urban railway is considered as a sample station to be studied. Considering the existing condition of the station as a reference design, the effects of changes of concrete compressive strength, section height and type of rebar on load-bearing capacity of the structure are investigated. Further, economic analysis of the mentioned changes is conducted to obtain the most efficient design. The results indicate that bending members play more important roles; thus, an increase of concrete compressive strength could not substantially affect the decrease of area of reinforcement in those members. The minimum concrete compressive capacity that can be utilized in I2 station is C25 grade, so that the lower concrete grades could not meet the structural requirements. Furthermore, the results of parametrical analysis show that an increased concrete compressive strength as well as a decreased section height leads to a similar cost and load-bearing capacity to the reference design, while including better durability and lifetime characteristics. In this way, with the purpose of obtaining a similar load-bearing capacity to the reference design, utilization of rebar with increased strength grade (AIV instead of AIII rebar) can also result in decreasing the area of reinforcement, which can be followed by a 9% added value for the project.
Odnawialne źródła energii odgrywają kluczową rolę w transformacji energetycznej na świecie. Farmy wiatrowe jako OZE w dużym stopniu przyczyniają się do dekarbonizacji gospodarki i pozwalają na ograniczenie emisji szkodliwych substancji, takich jak dwutlenek węgla, emitowanych do otoczenia. W niniejszym artykule została przedstawiona analiza ekonomiczna lądowej farmy wiatrowej o mocy 33 MW. Wyznaczono graniczną cenę sprzedaży energii elektrycznej, który wynosi 147,23 USD/MWh dla bazowych założeń bez zewnętrznego wsparcia finansowego oraz 63,43 USD/MWh z zewnętrznym wsparciem w postaci zielonych certyfikatów. Przedstawiono analizę wrażliwości i wpływ wskaźnika mocy znamionowej turbiny wiatrowej oraz wybranych parametrów na LCOE farmy wiatrowej. Dalszy rozwój elektrowni wiatrowych może mieć pozytywny wpływ na obniżenie granicznej ceny sprzedaży energii elektrycznej.
EN
Renewable energy sources are playing a key role in the world's energy transition. Wind farms, as RES, contribute greatly to the decarbonization of the economy and allow reducing emissions of harmful substances such as carbon dioxide emitted into the environment. This article presents an economic analysis of a 33 MW onshore wind farm. The levelized cost of energy was determined, which is 147.23 USD/MWh for the base assumptions without external financial support and 63.43 USD/MWh with external support in the form of green certificates. A sensitivity analysis and the impact of the wind turbine rating index and selected parameters on the LCOE of a wind farm are presented. Further development of wind power plants may have a positive impact in the future on lowering the levelized cost of energy.
W niniejszym artykule przedstawiono wyniki analizy techniczno-ekonomicznej różnych typów konstrukcji stropu kondygnacji powtarzalnej budynku szpitala uzyskane w ramach pracy dyplomowej magisterskiej wykonanej na Wydziale Inżynierii Lądowej Politechniki Warszawskiej. Do rozważań przyjęto strop o konstrukcji żelbetowej opartej na belkach żelbetowych (w dwóch wariantach – płyty jednokierunkowo zbrojonej i płyty dwukierunkowo zbrojonej) oraz o konstrukcji zespolonej stalowo-betonowej, w której płyta stropu wykonana została jako strop zespolony z blachą fałdową oparty na belkach stalowych. Przedstawiono podstawowe wyniki obliczeń oraz porównano koszt wykonania poszczególnych rodzajów stropów.
EN
This article presents the results of a technical and economic analysis of different types of floor construction of the recurrent floor of a hospital building obtained as part of the master’s thesis carried out at the Faculty of Civil Engineering of Warsaw University of Technology. The solutions taken into consideration are: a floor with a reinforced concrete structure based on reinforced concrete beams (in two variants – a one-way reinforced slab and a two-way reinforced slab) and a steel-concrete composite structure in which the floor slab was made as a composite floor with a corrugated plate based on steel beams. The basic results of calculations are presented, and the cost of constructing each type of floor is compared.
10
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W artykule przeprowadzono analizę porównawczą budowy sieci kanalizacyjnych, z wykorzystaniem dwóch różnych metod: bezwykopowej (technika mikrotunelowania) i wykopu otwartego.
EN
The article presents a comparative analysis of the construction of sewage networks using two different methods: trenchless (microtunneling technique) and open excavation.
This article presents an assessment of the technical and economic feasibility of a 20 MW grid-connected windsolar-photovoltaic hybrid system in the city of Dakhla, located in southern Morocco. During this study, GIS and virtual reality were integrated to model and simulate the productivity of the hybrid system under local climatic conditions. Additionally, 3D modeling of the system provides an immersive view to visually assess the system’s impact on the local landscape and anticipate potential logistical challenges. By taking advantage of this technology, our study goes beyond traditional models, proposing an innovative approach to better understand the spatial and visual dimensions of the project. The results of our study, based on these state-of-the-art methodologies, reveal promising conclusions regarding its annual energy production, which is approximately 60 GW, the levelized cost of energy of the system, which is approximately LCOE = $0.045/kWh, the net present value (NPV) of $27,439,559.00, the internal rate of return (IRR) of 17.5%, and a discounted payback period (DPP) of 8 years. Additionally, from an environmental perspective, the hybrid system has the capacity to avoid approximately 936,494 tons of greenhouse gas emissions, equivalent to savings of approximately $18,729,875.00 in terms of carbon dioxide reduction over its lifetime.
As the global quest for sustainable energy solutions intensifies, the role of solar power plants in meeting energy demands while mitigating environmental impact becomes increasingly vital. This study focuses on the performance evaluation and economic analysis of Engreen Sarishabari Solar Plant Ltd., a 3.3 MW grid-connected photovoltaic (PV) power plant located in Sarishabari, Jamalpur, Bangladesh. A thorough evaluation of the solar power plant’s performance ratio was carried out using the PVsyst software and data supplied by plant authorities. Moreover, a mathematical model was developed to analyze energy output variations, while grid stability post-integration of PV into the distribution feeder was examined under diverse conditions, including load and irradiance variations, as well as different short-circuit fault scenarios. The findings reveal that the annual performance ratio of the solar power plant stands at approximately 71%, with an average annual energy production of 3132 MWh. With a pay-back period of 10.1 years and an energy generating cost per kWh of 0.1132 USD, the installation cost came to 6,740,853 USD. This research not only provides valuable insights into the operational efficiency and economic viability of the Engreen Sarishabari Solar Plant Ltd. but also contributes to the broader discourse on the integration of solar energy into the grid infrastructure of Bangladesh, offering practical implications for policymakers, energy stakeholders, and investors striving towards a sustainable energy future.
Purpose: The research objective of the work is to quantify the levels of profitability of a photovoltaic installation for a company from the clothing industry. The authors of the article answer the question of where and under what boundary conditions in Poland there is already economic justification for the construction of photovoltaic power plants producing energy for the needs of their own business activity. Design/methodology/approach: The study was conducted using the methods of models of economic measures. These methods allowed the authors to calculate the market value of the investment with the assumed boundary criteria and to determine the economic efficiency of the investment. In addition, the authors made an analysis of the energy consumption of the company's implementation of individual manufacturing processes. The research was carried out in the period 2020-2022 on the example of a real PV installation. Findings: Installing a photovoltaic system in production plants brings many benefits. It should be noted that each kWh produced in a PV installation makes the investor independent of the grid distributor, reduces the consumption of energy from conventional sources, minimizes the emission of pollutants into the atmosphere and favors economic development. In addition, investment in this type of installation allows for obtaining income from the sale of surplus energy produced. Practical implications: The presented models have shown that the project of their implementation is fully economically justified and will allow investors to make a rational investment decision. Originality/value: The contribution of this work is to obtain data that allowed the authors to indicate directions for improvement that may contribute to a more reliable assessment of the profitability of the tested installations. The proposed research can improve the planning of new industrial plants in terms of PV Installations as well as the redesign of existing ones.
The complex relationships of economic actors and the high dependency on information and communication technologies make it necessary for all relevant entities to develop protection. This protection should include preventive and reactive controls in a risk-proportionate manner in relation to the business value protected. We aimed to develop a solution to support cybersecurity-related business decisions with financial analytics. The risk-based approach helps management find the optimum solution with minimal costs, where protection prevents some incidents from occurring, while the risks associated with other incidents are accepted in an informed way. The security industry developed a number of apparatuses to find the optimum security controls that enforced the fiscal aspects, which typically contain solutions used in planning. However, the actual expenditure often differs from the planned budget for several reasons, one of which is the occurrence of security incidents. We used the common methodology toolset for financial analysis (NPV, NFV, risk assessment). We developed novel metrics based on these that can be used in cybersecurity management. Within the framework thus defined, the article discusses the economic context of the effects of incidents involving Meta (previously Facebook) services from 2016 to 2020. This paper introduces the ‘Effect of incidents’ metric to measure the impact of unplanned incidents’ on actual expenditure compared to the planned budget and the ‘Incidence of incident recognition’ metric to measure deviations of an incident’s impact as perceived by owners relative to the effect on the value of the assets. The paper also proves the applicability of those metrics using the example of Meta.
One potential solution for reducing carbon dioxide emissions from ships and meeting the Energy Efficiency Existing Ship Index (EEXI) requirements is to use a hybrid propulsion system that combines liquid hydrogen and liquefied natural gas fuels. To improve energy efficiency for diesel-electric dual-fuel ship propulsion systems, an engine power limitation system can also be used. This paper examines the potential use of these systems with regard to several factors, including compliance with EEXI standards set by the International Maritime Organization, fuel ratio optimisation, installation requirements, and economic feasibility. As a case study, an LNG carrier is analysed, with dual-fuel diesel-electric and two hybrid systems adjusted to meet IMO-EEXI requirements with engine power limitation percentages of 25%, 0% (hybrid option 1), and 15% (hybrid option 2), respectively. From an economic standpoint, the liquid hydrogenbased system has competitive costs compared to the dual-fuel diesel-electric system, with costs of 2.1 and 2.5 dollars per kilogram for hybrid system options 1 and 2, respectively.
Vehicle transport is the predominating type of technological transport in natural stones mines, and its profitability is closely related to the operating costs. Reasonable selection of a transport system with the use of haul trucks should result from a thorough analysis of technical and economic aspects – investment and operational ones. Moreover, haul trucks should be selected having regard to all relevant parameters for specific mining and geological conditions. Given the above, this paper presents a technological and economic analysis of the loading and transport process in a natural stones mine.
17
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Istnieją dwa główne sposoby zmniejszenia zużycia wody wodociągowej w budynkach, wykorzystanie ścieków szarych lub wód opadowych na część potrzeb budynku i jego użytkowników. W niniejszej publikacji przedstawiona zostanie analiza możliwości wykorzystania systemu gromadzenia i podczyszczania ścieków szarych w budynku zamieszkania zbiorowego - akademika zamieszkiwanego przez 195 osób. Głównym celem przedstawionej w artykule modernizacji było zaprojektowanie w istniejącym budynku dualnej instalacji wodno-kanalizacyjnej uzupełniającej istniejącą instalację o piony kanalizacyjne zbierające wodę z umywalek oraz natrysków oraz instalację wodociągową zasilającą wodą szarą spłuczki toalet i pisuarów w budynku zamieszkania zbiorowego - Dom Studenta nr 1 znajdujący się przy Alei Politechniki 3b w Łodzi wraz ze sporządzeniem kosztorysu instalacji. Analizę oparto o rzeczywiste zużycie wody wodociągowej w Domu Studenta, przenalizowano koszty użytkowania obiektu w odniesieniu do opłat za wodę wodociągową i ścieki oraz koszty energii elektrycznej.
EN
There are two main ways to reduce the consumption of tap water in buildings, usage of gray sewage or rainwater, for part of the needs of the building and its users. This publication presents an analysis of the possibilities for using a gray sewage collection and pre-treatment system in a collective housing building - a dormitory inhabited by 195 people. The main goal of the modernization presented in the publication was to design a dual water and sewage installation in the existing building, which supplements the existing installation with sewage risers collecting water from washbasins and showers, and a water supply installation supplying gray water to the flush toilets and urinals in the collective residence building - Student Dormitory No. 1 located at Alei Politechniki 3b in Łódź, along with preparing a cost estimate of the installation. The analysis was based on the actual consumption of tap water in the Student Dormitory, and the costs of using the facility were analyzed in relation to fees for tap water and sewage, as well as the costs of electricity.
18
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The paper presents the results of a technical and economic analysis of the power supply for a model industrial facility based on intermittent renewable energy sources in the form of wind turbines and photovoltaic modules, supplemented with hydrogen energy storage. The adopted power supply strategy assumed the maximisation of self-consumption of self-produced electricity. Six variants were considered, including two with an energy storage system, three using only RES, and a reference variant in which the model facility is powered by the power grid. The modelling and optimisation of the proposed variants was carried out in the HOMER software, in terms of the lowest net present cost. The results obtained indicate that the most advantageous configuration is a grid-connected hybrid renewable energy system consisting of wind turbines and a photovoltaic power plant. A system with hydrogen energy storage is much more profitable than powering the facility from the grid. The profitability of hydrogen energy storage increases even more with the projected increase in electricity prices and the falling prices of hydrogen system components.
PL
W artykule przedstawiono wyniki techniczno-ekonomicznej analizy zasilania modelowego obiektu przemysłowego energią elektryczną pochodzącą z niestabilnych źródeł energii odnawialnej. Jako źródła OZE rozpatrzono turbiny wiatrowe i moduły fotowoltaiczne współpracujące z wodorowymi magazynami energii. W przyjętej strategii zasilania założono maksymalizację zużycia na potrzeby własne samodzielnie wyprodukowanej energii elektrycznej. Rozważano sześć wariantów, w tym dwa z systemem magazynowania energii, trzy wykorzystujące wyłącznie OZE oraz wariant referencyjny, w którym modelowy obiekt był zasilany z sieci elektroenergetycznej. Modelowanie i optymalizację zaproponowanych wariantów przeprowadzono w programie HOMER pod kątem najniższego kosztu bieżącego netto. Uzyskane wyniki wskazują, że najkorzystniejszą konfiguracją jest przyłączony do sieci hybrydowy system energii odnawialnej, składający się z turbin wiatrowych i elektrowni fotowoltaicznej. Taki system z układem magazynowania energii za pośrednictwem wodoru jest znacznie bardziej opłacalny niż zasilanie obiektu z sieci. Rentowność magazynowania energii znacząco rośnie wraz z prognozowanym wzrostem cen energii elektrycznej i spadkiem cen elementów instalacji wodorowych.
Sektor ciepłowniczy stoi przed wyzwaniami związanymi z transformacją w obszarze źródeł wytwarzania. Regulacje prawne i dynamicznie zmieniające się ceny nośników energii skłaniają do inwestowania w nowe rozwiązania. W artykule przedstawiono technologie decydujące o efektywności systemu ciepłowniczego – jednym z warunków uzyskania dotacji na rozwój, a także analizę ekonomiczną jako podstawę do podejmowania decyzji inwestycyjnych.
EN
The district heating sector is presently facing the challenges associated with the transformation of energy generation sources. Legal regulations and dynamically changing prices of energy carriers encourage investment in new solutions. The article presents technologies decisive for efficiency of district heating systems, which is one of the conditions to obtain subsidies for development, and also provides economic analysis as the basis for investment decisions.
To better understand the latest development of renewable energy systems, recent studies on multi-energy complementary power systems with a high proportion of renewable energy are reviewed in this paper. The connection modes of power grids and economic system analysis are summarized and discussed respectively, putting forward some suggestions on the system design and operation optimization. Firstly, the characteristics and differences between an integrated system and an off-grid system are reviewed, concluding that an integrated system is more reliable and costeffective based on a few case studies. Secondly, the commonly used economic parameters and cost evaluation methods of the hybrid power system are reviewed. Those methods offer crucial tools to optimize the system, and they are able to analyze the system feasibility, enabling the most economical configuration. The results of several cases prove that the hybrid multi-energy system is more economical than the single-energy system. Finally, there are few articles focusing on technical details assessments and environmental impacts, which leaves room for future study.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.