Znaleziono wyników: 18
Liczba wyników na stronie
Wyniki wyszukiwania
into the nutritional value, medicinal properties, and potential applications in different fields. The results of the FTIR analysis showed absorbance bands in the same wavelengths, but with different peaks, indicating the presence of long-chain linear aliphatic compounds, lipids, amides, aromatic compounds, and other functional groups in both plants. The CHNS/O analysis revealed high levels of carbon and oxygen, followed by hydrogen, nitrogen, and sulfur for both plants, with no significant differences in the values. The ICP analysis detected 16 minerals, including calcium, potassium, phosphorus, and magnesium in Ammi visnaga, and low levels of sodium in comparison to Calendula officinalis. Calendula officinalis accumulated more aluminum and lead than Ammi visnaga, indicating higher tolerance to contaminations. Zinc, iron, manganese, and copper were important micronutrients present in both plants. The findings of this study suggest that both plants have significant amounts of phytochemical compounds and minerals, which could be beneficial for their potential use in the pharmaceutical, nutraceutical, and cosmetic industries.
2
was used for an identically prepared feed. The feed for the separators consisted of PCBs shredded in a knife mill at cryogenic temperatures. The separation efficiency and purity of the products were evaluated based on microscopic analysis, ICP-AES, SEM-EDS, XRD, and specific density. The yield of concentrates (valuable metals) obtained from the shaking table and the cyclofluid separator amounted to 25.7% and 18.9%, respectively. However, the concentrate obtained from the cyclofluid separator was characterised by much higher purity, amounting to ~88% of valuable metals, compared to ~72% for the shaking table. In both cases, middlings formed a significant share, their yield amounting to ~25%, with the share of valuable metals of ~15%. The yield of waste obtained from the shaking table and the cyclofluid separator were 42.6% and 52.5%, respectively. In both cases, as a result of the applied process, the waste was divided into two homogeneous groups differing in grain size and shape. The recovery of metals through gravity separation is possible, in particular, by using a shaking table. These processes can also be applied to separate waste (plastics) into two groups to be selectively processed to produce new materials in line with a circular economy.
atomowej ze wzbudzeniem w indukowanej plazmie (ICP-AES) i spektrometrii mas ze wzbudzeniem w indukowanej plazmie (ICP-MS). Przy wykorzystaniu testów statystycznych dokonano porównania wyników oznaczeń glinu w próbkach wód podziemnych dla poszczególnych technik analitycznych.
coupled plasma atomic emission spectroscopy (ICP-AES) and inductively coupled plasma mass spectrometry (ICP-MS). The results of aluminum determinations in groundwater samples for particular analytical techniques were compared based on statistical analysis.
Wierzbno and Mokobody commune. Quarterly investigations covered analysis of water reaction (pH) by potentiometric method, electrical conductivity (EC) by electrochemical method and total concentration of 26 elements by inductively coupled plasma atomic emission spectrometry (ICP-AES). It was found that untreated waters being the source of tap water in selected localities on South Podlasie Lowland contained excessive iron and manganese amounts, that were efficiently removed during the treatment. Concentration of analyzed elements in treated water did not exceed the permissible limits and quality of analyzed tap water changed a little during its transport due to the secondary contamination.
różnych dzielnicach Łukowa i Sokołowa Podlaskiego, a także w różnych miejscowościach gmin Łochów, Wierzbno i Mokobody. Próbki wody pobierano w odstępach kwartalnych. W pobranych próbkach oznaczono odczyn (pH) wody metodą potencjometryczną, przewodnictwo właściwe metodą elektrochemiczną oraz stężenie K, Ca, Mg, Na, S, Fe, Mn, B, Li, Ba, Sr, Cu, Zn, Ni metodą optycznej spektrometrii emisyjnej ze wzbudzeniem w plazmie sprzężonej indukcyjnie (ICP-AES). Stężenie pierwiastków objętych badaniami na ogół nie przekraczało obowiązujących wartości dopuszczalnych. Sporadycznie odnotowano podwyższone wartości analizowanych parametrów w próbkach wody pobieranych w kurkach czerpalnych, wskazujące na zanieczyszczenie wody w systemie dystrybucji. W wodzie surowej stwierdzono ponadnormatywne stężenia żelaza i manganu, ale pierwiastki te były skutecznie usuwane w procesie uzdatniania.
biochemical oxygen demand, total concentration of twenty six elements by inductively coupled plasma atomic emission spectrometry (ICP-AES). The resulting data were processed statistically using arithmetic means, concentration ranges, standard deviations and relative standard deviations. Due to the effect of sample collection date on concentrations of analyzed elements, a single factor analysis of variance and Tukey post-hoc test were completed. It was found that the quality of water in the rivers was differential if selected water quality indicators were taken account. The values of this indicators were dependent on location of checkpoints, season and type of surrounding grounds cultivation. The quality of water in particular checkpoints was affected by anthropogenic sources of contamination: community waste from private possessions and sewage from fertilized arable land and greenlands.
pierwiastków metodą ICP-AES. Uzyskane dane opracowano statystycznie podając średnie arytmetyczne, zakresy stężeń, odchylenie standardowe (SD) oraz względne odchylenie standardowe (RSD). Z uwagi na wpływ terminu pobrania próbki na zawartość pierwiastków przeprowadzono jednoczynnikową analizę wariancji. Stwierdzono, że jakość wód analizowanych rzek była zróżnicowana w zakresie badanych wskaźników jakości. Na wartość wybranych wskaźników wpływała głównie lokalizacja pobrania próbki wody, pora roku oraz sposób użytkowania terenów przyległych. Zróżnicowaną jakość pobieranej wody powodowały antropogenne źródła zanieczyszczeń, a przede wszystkim zrzuty ścieków komunalnych z prywatnych posesji i spływy z nawożonych terenów rolniczych. Sporadyczne występowanie podwyższonych wartości niektórych wskaźników miało charakter punktowy i zmniejszało się w dalszym biegu rzek.
wody pobrano w czterech terminach, w odstępach kwartalnych, w latach 2004/2005. Badano w nich zawartość 26 pierwiastków metodą ICP-AES. Uzyskane dane opracowano statystycznie. Stwierdzono, że jakość wody uzdatnionej przekazywanej do systemu dystrybucji w Siedlcach spełnia wszystkie normy w zakresie wskaźników objętych badaniami. Jej jakość w wyniku wtórnego zanieczyszczenia ulega niewielkiej zmianie w czasie transportu. Nie zaobserwowano znacznych przekroczeń dopuszczalnych stężeń składników mineralnych w próbkach wody, a niewielkie ponadnormatywne ilości wystąpiły w małej liczbie analizowanych próbek.
by inductively coupled plasma atomic emission spectrometry (ICP-AES). The resulting data were processed statistically. It was found that treated water in Siedlce water supply system meets the requirements for drinking water. Quality of water slightly worsens during transport due to secondary contamination, but this happened sporadically.
wastes. The aim of this study was to determine the total content of lithium, barium and strontium in waste activated sludge produced in the sewage purification plant of meat processing factory in Sokolow Podlaski. 20 samples were collected periodically, at biweekly intervals, from March to December in 2005. Total content of Li, Ba and Sr was determined using inductively coupled plasma atomic emission spectrometry (ICP-AES). The data were processed statistically using means, percentiles, and concentration ranges. Due to the variability of trace elements content in waste activated sludge within sample collection date a single factor analysis of variance was completed. It was found that the total content of lithium, barium and strontium in the analyzed sludge was low and this material could be used as soil amendment.
Celem niniejszej pracy było przedstawienie ogólnej zawartości litu, baru i strontu w osadach ściekowych wytworzonych w oczyszczalni ścieków zakładów mięsnych w Sokołowie Podlaskim. Do badań wybrano 20 próbek osadu ściekowego pobranych od marca do grudnia 2005 r. w odstępach dwutygodniowych. W próbkach oznaczono całkowitą zawartość litu, baru i strontu metodą atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie sprzężonej indukcyjnie (ICP-AES). Uzyskane dane opracowano statystycznie, przedstawiając zawartości wybranych pierwiastków śladowych jako średnie, percentyle oraz zakresy stężeń. Wykazano istotne różnice w zawartościach wybranych pierwiastków śladowych, w zależności od terminu pobrania próbki, przez jednoczynnikową analizę wariancji. Stwierdzono, że całkowita zawartość litu, baru i strontu w próbkach osadów ściekowych była relatywnie mała, co pozwala na rolnicze wykorzystanie tych odpadów.
from clinical and environmental chemistry. The paper presents an updated review of the techniques for hair analysis, including spectrometry and more sophisticated methodologies adopted for result confirmation and/or for research purposes.
presented for the elemental and dimensional characterization of atmospheric fine aerosols and, in particular, for its submicronic fraction, obtained by gravitational sedimentation (operational cut-off: 2 žm). The natural sample particle matter < 10 žm (PM,10), was transferred from collection filters into slurry aqueous solution, via ultrasonic agitation. The direct slurry sample analysis by ICP-AES, evaluated to be accurate enough for the investigation of heavy metal occurrence, was shown able to provide prompt analytical answers, thanks to its instrumental multi-elemental performances, either for the total PM,10 sample and relative subsamples, obtained by gravitational sedimentation. The considered heavy metals of environmental interest were Cd, Cr, Cu, Ni, Mn and Pb. The SdFFF fractionation was applied to the sub-sample < 2 žm to determine the particie size distribution. The collected fractions were analyzed by Scanning Electron Microscopy (SEM).
wykorzystaniu techniki ICP-MS możliwe było bezpośrednie i szybkie oznaczenie zawartości metali ciężkich, takich jak Cd, Cr, Cu, Ni, Mn oraz Pb. Frakcjonowanie SdFFF wykorzystano natomiast dla próbek aerozoli zawierających cząstki o średnicy mniejszej niż 2 žm w celu wyznaczenia rozkładu rozmiaru cząstek. Zebrane frakcje analizowane były przy wykorzystaniu Skaningowego Mikroskopu Elektronowego.
been paid to sample preparation, an important stage at which a sample is explored to contaminants. Results of the analysis of all samples arc discussed.
(ICP-AES). Szczególną uwagę zwrócono na przygotowanie próbek, roztwarzanie, będące niezwykle ważnym i istotnym krokiem, w którym próbka narażona jest na zanieczyszczenie. Otrzymane wyniki posłużyły do przeprowadzenia dyskusji na temat roztwarzania i mineralizacji analizowanych materiałów.
kontakcie z wyżej wymienionymi urządzeniami i materiałami, za pomocą odpowiednio czułych metod spektrometrii atomowej, np. spektrometrii emisyjnej ze wzbudzeniem w plaźmie indukcyjnie sprzężonej (ICP-AES). Przeprowadzone badania potwierdziły występowania zjawiska uwalniania się srebra z filtrów węglowych, modyfikowanych tym pierwiastkiem, stosowanych do doczyszczania wody. Dodatkowo materiały, służące do budowy instalacji i armatury, mogą być odpowiedzialne za znaczne zwiększenie w wodzie wodociągowej obserwowanych stężeń metali, takich jak: chrom, nikiel, miedź, cynk i ołów. Materiały stosowane do uzdatniania wody w procesach technologicznych wodociągów, takie jak piasek, grys czy też wapno hydratyzowane, zazwyczaj nie powodują wtórnego zanieczyszczenia wody metalami ciężkimi.
wodnym. Tym bardziej, że zgodnie z rozporządzeniem ministra zdrowia, obowiązującym w Polsce w sprawie wymagań dotyczących jakości wody przeznaczonej do spożycia przez ludzi, najwyższe dopuszczalne stężenie (NDS) As w wodzie do picia zostało ustalone na niskimpoziomie, wynoszącym 0,01 mg/l. Dodatkowo, metody analityczne, stosowane do oznaczeń tego metalu, muszą charakteryzować się granicą wykrywalności równą 1μg/l, (lub niższą) przy uzyskiwanej 10-procentowej precyzji, wyrażonej jako względne odchylenie standardowe, i 10-procentowej poprawności podczas oznaczeń arsenu na poziomie NDS. Celem pracy była ocena możliwości oznaczania arsenu w wodzie metodą ICP-AES z różnymi układami wprowadzania analitu do plazmy o geometrii poziomej przy zastosowaniu osiowego systemu obserwacji i porównanie charakterystyki opracowanej metody z analogiczną metodą opartą na detekcji AAS.
Coupled Plasma Atomic Emission Spectrometry (ICP-AES).
w nich ołów za pomocą atomowego spektrometru emisyjnego z indukcyjnie wzbudzoną plazmą (ICP-AES).
jest do oznaczania prawie wszystkich pierwiastków układu okresowego za wyjątkiem gazów. W laboratoriach, w zależności od potrzeb i zasobów materialnych, można spotkać spektrometry sekwencyjne, bądź jednoczesne.
on a mass of sample was studied. The correlations between elements are discussed.
między badanymi pierwiastkami.
100 mg może wywołać silne zatrucie człowieka. Zgodnie z normą IMO Gliwice dopuszczalna zawartość tego pierwiastka nie powinna przekraczać 0,0005% As. Oznaczanie tak niskich zawartości arsenu przy użyciu techniki atomowej spektrometrii absorpcyjnej lub spektrometrii emisyjnej z plazmą wzbudzoną indukcyjnie, jest kłopotliwe z powodu wpływów matrycowych, pochodzących od pierwiastków głównych Ca i Mg. Przedmiotem badań była optymalizacja warunków oznaczania arsenu metodą spektrometrii emisyjnej z plazmą wzbudzoną indukcyjnie i zastosowaniem generacji wodorków. Metoda generacji wykorzystuje zdolność tworzenia przez arsen lotnych wodorków co pozwoliło wyeliminować wpływy matrycy. Wyznaczono doświadczalnie granicę wykrywalności, czułość, precyzję i liniowość metody oznaczania arsenu w dolomicie.
concentration of toxic elements present in dolomite. One of these, which may be very toxic is arsenic. IMO Gliwice standard allows up to 0,0005% maximum concentration of this element in a dolomite. Analysis of such Iow concentration by means of atomic absorption spectrometry or of inductively coupled plasma atomic emission spectrometry (ICP AES) techniques is very troublesome on account of the matrix effects, caused by the presence of high concentration of Ca and Mg in the tested dolomite samples. The aim of the investigations was the optimization of the conditions of As determination in dolomite by the ICP AES technique coupled with hydride generation. There have been examined: the detection limit, sensitivity, linearity and precision of the determination. The use of hydride generation technique combined with ICP AES has proved to be a sensitive analytical tool for the determination of the Iow arsenic levels able to form volatile hydride, which allows to avoid the matrix effects, as Ca and Mg do not form volatile hydride compounds. Another advantage of the elaborated method is a considerable decrease of the detection limit of arsenic determination (DL = 0,7 ppb As) in comparison with the "classic" ICP AES method.
Ograniczanie wyników