Boiling heat transfer can be enhanced when the heater’s surface morphology is altered. The paper discusses the use of the laser beam to produce efficient heat exchangers. Two types of samples were investigated with distilled water and ethyl alcohol as boiling agents. The specimens differed with the height of the microfins: 0.19 mm and 0.89 mm. It was observed that both of them enhanced boiling heat transfer in comparison to the smooth reference surface. However, the sample with higher micro-fins performed better, especially in the region of low temperature differences, where the heat flux was about three times higher than in the case of the smaller microfins. The comparison of the experimental data with selected models of boiling heat transfer revealed significant differences with regard to the heat flux. The laser-made samples dissipated larger heat fluxes than it could be anticipated according to the models. It might be linked with high surface roughness of the area between the microfins, generated as a result of the laser beam interaction with the surface.
W artykule omówiono wpływ osadów na poprawność działania wymienników ciepła oraz ich impakt na aspekt energetyczny i straty eksploatacyjne z nimi związane. Zwrócono także uwagę na konieczność okresowego oczyszczania wymienników z osadów oraz zapewnienie właściwych parametrów wody stosowanej w układach chłodniczych. Autorzy przedstawili również metody uzdatniania wody dla układów chłodniczych.
This review paper explores the significance of fluidized bed heat exchangers in various industrial applications. By delving into the operation of fluidized beds as multiphase flow systems, the aim is to enhance their capabilities and efficiency. Key parameters such as minimum fluidization velocity and local gas holdup are crucial for characterizing the hydrodynamic behavior of materials within fluidized beds. Fluidization, achieved by passing atmospheric air through particulate solids, imparts fluid-like properties to the bed. Fluidized beds serve as reactors where this phenomenon takes place, offering several advantages in industrial processes, including high rates of heat and mass transfer, low pressure drops, and uniform temperature distribution. In future work, a focus on understanding and optimizing the fluidization process will contribute to further advancements in the performance of fluidized bed heat exchangers.
PL
W artykule przedstawiono przegląd literatury dotyczący znaczenia wymienników ciepła ze złożem fluidalnym w różnych zastosowaniach przemysłowych. Zwiększenie możliwości i wydajności złóż fluidalnych jest celem badań tych wielofazowych systemów przepływowych. Kluczowe parametry, takie jak minimalna prędkość fluidyzacji i lokalne zatrzymywanie gazu, mają kluczowe znaczenie dla scharakteryzowania zachowania hydro-dynamicznego materiałów w złożach fluidalnych. Fluidyzacja, osiągnięta poprzez przepuszczanie powietrza atmosferycznego przez cząstki stałe, nadaje złożu właściwości zbliżone do płynu. Złoża fluidalne służą jako reaktory, w których zachodzi zjawisko fluidyzacji, oferując szereg korzyści w procesach przemysłowych, w tym wysokie szybkości wymiany ciepła i masy, niskie spadki ciśnienia i równomierny rozkład temperatury. W przyszłych pracach skupienie się na zrozumieniu i optymalizacji procesu fluidyzacji przyczyni się do dalszego postępu w wydajności wymienników ciepła ze złożem fluidalnym.
4
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Energia spalin z dopalania gazów procesowych pochodzących z pieca szybowego o temp. powyżej 1000°C jest odbierana w wymienniku ciepła, gdzie dominującym zjawiskiem wymiany ciepła jest promieniowanie. Analizie poddano wpływ parametrów gazów procesowych oraz postaci konstrukcyjnej wymiennika dla instalacji pilotowej i przemysłowej na emisyjność i wielkość jednostkowego strumienia ciepła odbieranego poprzez różną średnią drogę promienia w środowisku gazowym. Obliczenia przeprowadzono metodą analityczną i przy wykorzystaniu programu komputerowego HSC Chemistry 6. Emisyjność zapylonych spalin i jednostkowy strumień przekazywanego ciepła zwiększały się wraz z wydłużeniem średniej drogi promienia dla wymienników cylindrycznych i prostopadłościennych. Porównując wymienniki o różnych kształtach, ale tych samych objętościach, stwierdzono, że wymienniki cylindryczne oddawały większe jednostkowe strumienie ciepła w porównaniu z wymiennikami prostopadłościennymi.
EN
The emissivity of dusty flue gases and the size of the unit heat flux received in the cylindrical and rectangular heat exchanger were calculated. The calculations were carried out using the anal. method and by the HSC Chemistry 6 computer program. The detd. parameters increased with increasing av. path of the radius in the gaseous environment for both types of exchangers. The flue gas and the exchanger wall temperature as well as the dust and CO₂ content had the greatest impact on the values of the av. heat fluxes received by radiation. Cylindrical exchangers had higher unit heat fluxes compared to rectangular exchangers of the same volume
5
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Przedstawiono problematykę dotyczącą wytwarzania i eksploatacji wymienników ciepła w zbiornikach procesowych, pracujących w liniach technologicznych do przetwarzania warzyw i owoców. Powszechnie stosowane płaszczowe wymienniki ciepła z punktowymi spoinami montażowymi, wykonanymi ręcznie metodą TIG, są podatne na procesy korozyjne i osadzania się kamienia kotłowego. Są też wrażliwe na podwyższone poziomy ciśnienia medium grzewczo-chłodzącego. Natomiast wymienniki ciepła w postaci wężownicy wykonanej z ceownika zamontowanego na powierzchni zewnętrznej płaszcza wewnętrznego charakteryzują się mniejszą podatnością na korozję i osadzanie się kamienia kotłowego.
The operation time of HVAC systems in industry and construction engineering is counted in decades. Corrosion protection of these systems is crucial for their long-term and failure-free operation. In the case of working mediums based on glycols, corrosion protection is provided by anti-corrosion additives, which are the component of antifreeze. The defence mechanism consists in the interaction of these additives with metal surfaces, with whom they contact by creating durable and efficient layers separating their surfaces from aggressive environmental factors. Observation of the structure of protective layers and corrosion micro changes was possible due to the application of microscopic imaging. The main building material in heat exchangers is copper. Studies have shown that the dilution of antifreeze may result in the formation of insufficiently clear protective layers on the copper surface, which may intensify the negative effects of fluids on copper elements of infrastructure HVAC systems.
PL
Czas pracy systemów grzania i chłodzenia w przemyśle i budownictwie jest liczony w dziesięcioleciach. Ochrona przeciwkorozyjna tych systemów ma kluczowe znaczenie dla zapewnienia ich długotrwałej i bezawaryjnej pracy. W przypadku czynników roboczych na bazie glikoli ochronę przed korozją zapewniają przeważnie dodatki przeciwkorozyjne znajdujące się w składzie płynów niskokrzepnących. Mechanizm ochronny polega na oddziaływaniu tych dodatków z powierzchniami metali, z którymi mają kontakt poprzez wytworzenie trwałych i skutecznych warstw separujących ich powierzchnie od agresywnych czynników środowiska. Obserwacja struktury warstw ochronnych oraz mikrozmian korozyjnych była możliwa dzięki zastosowaniu metod obrazowania mikroskopowego. W konstrukcjach wymienników ciepła głównym budulcem jest miedź. W badaniach wykazano, że skutkiem rozcieńczania płynów niskokrzepnących może być uformowanie się niedostatecznie wyraźnych warstw ochronnych na powierzchni miedzi, co w konsekwencji może prowadzić do nasilenia negatywnych skutków oddziaływania płynów na miedziane elementy konstrukcji infrastrukturalnych systemów wymiany ciepła.
W artykule przedstawiono ogólne informacje na temat budowy lamelowych wymienników ciepła oraz podano algorytm obliczeń cieplno-hydraulicznych dla tego typu wymienników. Informacje zawarte w artykule mają na celu przedstawienie sposobu modelowania matematycznego tego typu wymienników i mogą stanowić źródło wiedzy dla inżynierów zajmujących się projektowaniem takich urządzeń.
The energy efficiency of ventilation systems is very important. The city of Kryvyi Rih in the Dnipropetrovs’k region of Ukraine has a humid continental climate with an average daily temperature of -6.3°C during its coldest month. Consequently, it is necessary to find methods to improve the energy efficiency of ventilation systems. One of the most effective ways to reduce energy consumption in ventilation systems is to use energy-saving technologies to maintain the microclimate of buildings, including the use of recuperators and devices based on renewable energy sources.
The paper discusses and presents the application of the Wilson plot method to the variety of issues related to convective heat transfer. The Wilson plot is a remarkable calculation procedure, which enables the analysis and estimation of convection heat transfer coefficient on the basis of experimental measurements of heat exchanger thermal and flow parameters and the evaluation of corresponding correlation equations. The main facility of the Wilson method is that the heat transfer coefficient can be obtained without the requirement of determining the surface temperature. Much attention was paid to clarify the concept of the standard, original Wilson method as well as its modified versions. The issue was presented in the form of the latest literature review, which featured the investigation of convection coefficients obtained by the Wilson method in the following cases: the flow of nanofluids, refrigerants and other working media in conventional and mini/micro channels and micro-tubes as well as heat transfer under boiling/condensation conditions. The validity of the method utilization has been presented and its future prospects have been specified.
PL
W artykule omówiono i przedstawiono zastosowanie metody Wilsona w różnorodnych zagadnieniach związanych z wymianą ciepła na drodze konwekcji. Metoda Wilsona pozwala na analizę i określenie konwekcyjnego współczynnika przejmowania ciepła na podstawie eksperymentalnych pomiarów parametrów cieplnych i przepływowych badanego wymiennika ciepła oraz zastosowanie lub opracowanie odpowiednich zależności korelacyjnych. Szczególnym atutem metody Wilsona jest możliwość określenia współczynnika przejmowania ciepła bez konieczności pomiaru temperatury powierzchni badanego wymiennika ciepła Dużo uwagi poświęcono wyjaśnieniu koncepcji standardowej, oryginalnej metody Wilsona oraz jej zmodyfikowanych wersji. Zagadnienie zostało przedstawione w formie przeglądu literatury, w którym uwzględniono podsumowanie wyników badań współczynników przejmowania ciepła uzyskanych metodą Wilsona w następujących przypadkach: przepływu nanocieczy, czynników chłodniczych i innych mediów roboczych w kanałach konwencjonalnych i mini/mikrokanałach oraz mikrorurkach, jak również wymianę ciepła podczas wrzenia/kondensacji. Przedstawiono zasadność wykorzystania metody oraz określono jej perspektywy na przyszłość.
10
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The changes in heat exchanger characteristics due to dirt sediment and the effect of corrosion on the conduction pipe can cause difficulty to control the system properly. To anticipate sudden changes in heat exchanger characteristics, this study then tried to identify the open loop recording curve on the heat exchanger in the form of a temperature curve and create a PID controller simulation program. The identification method used in this work was the C.L. Smith method. The simulation test results indicated that some changes in the process variables have occurred following the set point. In this case, the simulation often found some overshoot phenomena which would bring negative impact. In order to avoid the impact, the occurrence of overshoot must be reduced or eliminated.
PL
Zmiany w charakterystyce wymiennika ciepła spowodowane osadzaniem się brudu i wpływem korozji na rurę przewodzącą mogą powodować trudności w prawidłowym sterowaniu systemem. Aby przewidzieć nagłe zmiany w charakterystyce wymiennika ciepła, w ramach tego badania podjęto próbę zidentyfikowania krzywej rejestracji w pętli otwartej na wymienniku ciepła w postaci krzywej temperatury i stworzenia programu symulacyjnego regulatora PID. Metodą identyfikacji wykorzystaną w tej pracy była metoda C.L. Metoda Smitha. Wyniki testów symulacyjnych wykazały, że pewne zmiany w zmiennych procesowych wystąpiły po wartości zadanej. W tym przypadku symulacja często wykazywała pewne przeregulowania, które miałyby negatywny wpływ. Aby uniknąć uderzenia, należy ograniczyć lub wyeliminować występowanie przeregulowania.
11
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
As a result of experimental studies, a mathematical model of the influence of the length of the air duct, volumetric air flow, air temperature in the external environment on the useful thermal power of the developed heat exchanger for its given geometric parameters was obtained. As a result of experimental studies, the optimal values of the design and technological parameters of the developed heat exchanger have been established, at which its useful thermal power is maximum.
PL
W wyniku badań eksperymentalnych uzyskano model matematyczny wpływu długości kanału powietrznego, objętościowego przepływu powietrza, temperatury powietrza w środowisku zewnętrznym na użyteczną moc cieplną opracowanego wymiennika ciepła dla zadanych parametrów geometrycznych. W wyniku badań eksperymentalnych ustalono optymalne wartości parametrów konstrukcyjnych i technologicznych opracowanego wymiennika ciepła, przy których jego użyteczna moc cieplna jest maksymalna.
12
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
A Heat Exchanger is a secondary process unit that is widely needed in the chemical process industry. This equipment is used to exchange heat between two types of fluids that have different temperatures. The existence of several physical events that change the characteristics of the process causes the stability of the system to be disturbed that necessitates to control the changes in the process parameters. PID controllers are actually conventional controllers which, due to their relatively good condition and easy operation, are still widely used. Many methods have been introduced to analyze PID control parameters, including the Rungge-Kutta method. However, the controlling operators in an industrial process, in order to get good control performance in every industrial process in the event of overshoot or oscillation, adjust the control parameters manually through the trial and error method. For this reason, we need a technique that is able to adapt to changes in process parameters that occur, and at the same time perform automatic re-tuning of controlling parameters. This paper describes a program designed to form an oscillation and reduction curve with a PID controller on a heat exchanger. The design of this program must at least be in accordance with the dynamics of the actual events in the field. the results of the oscillation curve reduction program design which are quite good are the one with the 'PI' controller type as compared to those with the 'P' and 'PID' controller types. The results of the one with the control type 'P' are not good because the process variable (process temperature) is not close to the set. o be used for operator training in industrial processes in the event of disturbances in the form of oscillations.
PL
Wymiennik ciepła jest drugorzędną jednostką procesową, która jest powszechnie potrzebna w przemyśle chemicznym. To urządzenie służy do wymiany ciepła między dwoma rodzajami płynów, które mają różne temperatury. Istnienie kilku zdarzeń fizycznych zmieniających charakterystykę procesu powoduje zaburzenie stabilności systemu, co wymusza kontrolowanie zmian parametrów procesu. Regulatory PID to właściwie regulatory konwencjonalne, które ze względu na stosunkowo dobry stan techniczny i łatwą obsługę nadal znajdują szerokie zastosowanie. Wprowadzono wiele metod analizy parametrów regulacji PID, w tym metodę Rungge-Kutty. Jednak operatorzy kontrolujący w procesie przemysłowym, w celu uzyskania dobrej wydajności sterowania w każdym procesie przemysłowym w przypadku przeregulowania lub oscylacji, dostosowują parametry sterowania ręcznie metodą prób i błędów. Z tego powodu potrzebujemy techniki, która jest w stanie dostosować się do zachodzących zmian parametrów procesu, a jednocześnie wykonać automatyczne przestrojenie parametrów sterujących. W artykule opisano program przeznaczony do tworzenia krzywej oscylacji i redukcji z regulatorem PID na wymienniku ciepła. Projekt tego programu musi być przynajmniej zgodny z dynamiką rzeczywistych wydarzeń w terenie. wyniki projektu programu redukcji krzywej oscylacji, które są dość dobre, to te z regulatorem typu „PI” w porównaniu z tymi z regulatorami typu „P” i „PID”. Wyniki tego ze sterowaniem typu „P” nie są dobre, ponieważ zmienna procesowa (temperatura procesu) nie jest zbliżona do zadanej. o być używany do szkolenia operatorów w procesach przemysłowych w przypadku zakłóceń w postaci oscylacji.
13
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
This paper presents models of three elements: heat exchanger, compressor and expander dedicated to supercritical CO2 cycles (Brayton). The models are built using Ebsilon software and validated against experimental data from available literature. Radial turbomachinery and thin plate heat exchangers were used to meet the demands of the relatively compact design of the S-CO2 cycle elements. It seems that there are no general relationships for the turbomachinery and real characteristics need to be used for constructing the models.
This paper presents a numerical study of heat transfer through a downstream annulus using water as the working fluid within the laminar flow region. The annulus consisted of an outer twisted square duct and an inner circular pipe. A three-dimensional formulation was used to solve the Navier-Stokes equations numerically for the laminar flow system with a low Reynolds number. Three parameters were used in the numerical simulation: the length of the twisted square [...] the inner diameter of the inner circular pipe [...] and 25 mm and the twist angle [...]. Numerical calculations were conducted on sixteen twisted square duct heat exchangers, with water flowing within a Reynolds number range of .220 1100− The results were illustrated as a profile of the thermal enhancement factor, the friction factor and the Nusselt number. The results show that the twisted outer duct of the heat exchanger can create a swirl flow along the length of the heat exchanger. It also caused a boundary layer separation-reattachment on the wall of the inner pipe. Moreover, an increase in the twist angle increased the Nusselt number by %,20 and the friction factor was also increased as the annular gap of the heat exchanger decreased.
W artykule opisano nową konstrukcję miniwymiennika ciepła typu płaszczowo-rurkowego wykorzystanego jako miniskraplacz niskociśnieniowych czynników chłodniczych HFE 7000 i HFE 7100. Konstrukcja ta jest odpowiedzią na światowy trend budowy wysokosprawnych, zminiaturyzowanych konstrukcji wymienników ciepła do zastosowań w HVACR. Autorzy określili charakterystykę procesu skraplania oraz wpływ grubości kondensatu na intensywność przejmowania ciepła. Wyniki pozwoliły opracować własną zależność obliczeniową pozwalającą wyznaczać wartości współczynnika przejmowania ciepła podczas skraplania czynników chłodniczych w miniwymiennikach płaszczowo-rurkowych o małej mocy cieplnej.
The present study proposes a novel concept of a solid biomass burner for household applications. The designed biomass stove is a multipurpose burner that can be used as a cooking stove and thermal generator. It works as a basic model of a biomass cooking stove and is coupled with a coil heat exchanger for thermal generation. The experimental evaluation is conducted by using the time-to-boil (TTB) method to measure the effective energy that can be harnessed from the combustion process. It shows that the maximum temperature outlet from the coil heat exchanger is 62.2 °C. The effective energy uptake for the coil heat exchanger is 41.9%, whereas the overall energy uptake, including the kettle, is obtained by more than 50%. Therefore, the proposed model can improve the efficiency of solid biomass burners for household ware.
Energooszczędne chłodziarki i pompy ciepła nie tylko zużywają mało energii do zasilania sprężarek, powinny mieć też tak dobrane wymienniki i czynniki chłodnicze, aby procesy w nich zachodzące były najbardziej efektywne. Optymalny dobór wymienników w urządzeniach ma, oprócz sprężarek i automatyki, istotny wpływ na koszty inwestycyjne i eksploatacyjne.
18
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Many educational institutions do not have sufficient resources to acquire expensive devices to make the dialoged and practical classes more attractive, both for students and for teachers. In view of these concerns, it is proposed a procedure that integrates PBL (Problem based Learning) and HIL (Hardware in The Loop) methods to test different dynamic systems, verify stability of the implemented control equations, or even validate useful algorithms in many areas, from basic disciplines of Exact Sciences to Technical and Engineering courses. The conception approach is presented here to justify the best possible cost-effectiveness benefits to simulate real-time systems, with financial and time reductions. The project consists of developing three prototypes (heat exchanger, electronic converter and “Beam and Ball” experiment) by means of a mathematical modeling using the Matlab / Simulink software, to embedded this model in a HIL hardware in order to simulate / diagnose the performance of such systems. These examples can be used in both practical and theoretical classes, in order to encourage students to deal with real problems in search of their solutions.
PL
Wiele instytucji edukacyjnych nie ma wystarczających srodków na zakup drogich urządzeń które uczynią prowadzone z dialogiem i zajęcia praktyczne bardziej atrakcyjnymi zarówno dla uczniów, jak i nauczycieli. W związku z powyzszym proponuje się procedurę integrującą metody PBL (Problem based Learning) i HIL (Hardware in The Loop) w celu testowania róznych układów dynamicznych, weryfikacji stabilności zaimplementowanych równan sterowania, a nawet walidacji użytecznych algorytmów w wielu obszarach, od z podstawowych dyscyplin nauk ścisłych po kursy techniczne i inżynierskie. Przedstawione jest tutaj podejście koncepcyjne w celu uzasadnienia możliwie najlepszych korzyści w zakresie efektywnosci kosztowej symulacji systemów w czasie rzeczywistym, przy jednoczesnym ograniczeniu finansowym i czasowym. Projekt polega na opracowaniu trzech prototypów (wymiennik ciepła, przetwornik elektroniczny i eksperyment „Belka i kula”) za pomocą modelowania matematycznego z wykorzystaniem oprogramowania Matlab / Simulink, w celu osadzenia tego modelu w sprzęcie HIL w celu symulacji / zdiagnozowania działania takiego systemy. Przykłady te mozna wykorzystać zarówno na zajęciach praktycznych, jak i teoretycznych, aby zachęcic uczniów do rozwiązywania rzeczywistych problemów w poszukiwaniu ich rozwiązania.
The aim of the study is to investigate the influence of external fins on heat transfer in the evaporator. The scope in which the analysis was performed is to check how the capacity of the exchanger is affected by the change of individual elements of the fin geometry. The introduction describes the current state of knowledge about evaporators. One of the subchapters is entirely devoted to the phenomenon of frosting evaporators, which is unfavourable from the point of view of heat transfer. The subsection also describes how to minimize the occurrence of this phenomenon. The next chapter presents mathematical models of heat transfer coefficients during boiling of inorganic refrigerants in horizontal pipes and during the flow of a bundle of smooth and air-fined pipes. On the basis of correlations and mathematical dependencies contained in this chapter, analyses of the influence of individual factors on heat transfer in the evaporator were performed. The next chapter contains the analysis methodology, it contains drawings of modeled heat exchangers. The penultimate chapter contains the results of the analyses with graphs and descriptions, detailing the most important differences between the individual evaporator geometries. The last chapter is a summary and conclusions about the effect of fins on heat transfer in the evaporator.
20
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
This study evaluates the common process and set-up design of a static compost bioreactor for heat recovery. A technology, which fits the goal of a sustainable, growing bioeconomy which combines the utilization of compost heat and compost material. Interest on this technology has been growing the last years but precise data of pilot scale reactors is rare. Data is required to adjust the process for custom needs and further technical development. Therefore, lignin-cellulose based biomass was composted in unaerated cylindrical compost reactors size 20 to 70 m3 for 140 days. The biomass comes with C:N ratio of about 25:1, water content of 43-48 %, organic matter content of 40.6 % d.m. and calorific value of 8.3 MJ/kg d.m. Spatial distribution of temperature and gas concentration (oxygen, carbon dioxide, methane) within the reactor shows methane production of the anaerobic core area. Maximum thermal power of 5.2 kW from a 63 m3 reactor with average temperature of heating flow about 40 °C was reached. Maximum recovered heating power of 4.8 MJ/kg d.m. was calculated for an operation of 6 month. This corresponds to 50 % of the measured calorific value. Biggest influence factors detected on the recovered heating power of the pilot scale reactor has been the size of reactor, the set up quality and the control of heat exchanger. The spatial correlation between heat production and aerobic digestion suggests a technical development in terms of aeration.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.