Nonlinear load characteristics intrinsic to switch-mode power converters lead to elevated harmonic distortion levels in the AC mains. This power quality degradation must be counteracted by implementing Power Factor Correction (PFC) techniques, frequently in the form of supplementary modular circuitry. The most widely adopted solution employs an active PFC configuration comprising inductive components and power switches that regulate and modify the converter’s input current, shaping it to mirror both the phase and waveform of the input voltage. This modelling of the mains current shape can be performed by means of various PFC topologies combined with distinct conduction modes of the PFC inductor. This paper provides an overview of PFC circuitry designs, including boost-type topologies and their derivatives, the flyback-topology-based configuration, and the bridgeless totem-pole architecture noted for its superior power conversion efficiency. A detailed theoretical analysis of the power factor correction problem is presented, along with descriptions of the main operational characteristics of the examined PFC topologies. The study is further supported by oscilloscope screenshots captured from real, physical PFC modules, either designed by the author (boost and flyback-based topologies) or acquired for the purposes of this research.
PL
Nieliniowe charakterystyki obciążenia, typowe dla przetwornic impulsowych, przekładają się na podwyższony poziom zniekształceń harmonicznych w sieci prądu przemiennego. Wynikające z tego pogorszenie jakości energii musi być korygowane przez zastosowanie korekcji współczynnika mocy PFC (ang. Power Factor Correction), często implementowanej w postaci dodatkowych modułowych układów elektronicznych. Najpowszechniej stosowanym rozwiązaniem są aktywne obwody PFC, składające się z elementów indukcyjnych i tranzystorów mocy, które regulują oraz kształtują prąd wejściowy przetwornicy tak, aby odpowiadał zarówno kształtem, jak i fazą napięciu wejściowemu. Modelowanie kształtu prądu sieciowego może być realizowane za pomocą różnych topologii PFC, w połączeniu z różnymi trybami przewodzenia cewki PFC. Niniejsza praca przedstawia przegląd układów PFC, w tym topologii typu boost, konfiguracji opartej na topologii flyback oraz bezmostkowej architektury typu totem-pole, znanej z wysokiej sprawności przetwarzania energii. Zaprezentowano szczegółową analizę teoretyczną problemu korekcji współczynnika mocy oraz opis głównych cech operacyjnych badanych topologii PFC. Badania zostały dodatkowo zilustrowane zrzutami ekranu z oscyloskopu, wykonanymi dla rzeczywistych, fizycznych modułów PFC zaprojektowanych przez autora (topologie typu boost i flyback) lub pozyskanych na potrzeby niniejszego artykułu. Badania te stanowią część projektu finansowanego przez Narodowe Centrum Badań i Rozwoju w ramach programu LIDER XV, na podstawie umowy o wykonanie i finansowanie projektu nr LIDER15/0205/2024.
PL
W artykule przedstawiono analizę strat przełączeniowe w przekształtnikach energoelektronicznych z tranzystorami SiC MOSFET. Omówiono wpływ częstotliwości przełączania na generowanie ciepła oraz metody ograniczania strat, takie jak stosowanie gasików, optymalizacja sterowników bramkowych i wykorzystanie zaawansowanych technologii materiałowych (SiC, GaN). Badania teoretyczne i praktyczne wskazują na korzyści z wykorzystania symulacji komputerowych w projektowaniu przekształtników.
EN
The paper presents an analysis of switching losses in power electronic converters with SiC MOSFET transistors. The influence of switching frequency on heat generation and methods of reducing losses, such as the application of snubbers, gate driver optimization and the use of advanced material technologies (SiC, GaN) are discussed. Theoretical and practical studies indicate the benefits of using computer simulations in the design of power inverters.
PL
Niniejszy artykuł zajmuje się problematyką zgodności inwerterowej pompy ciepła z przekształtnikiem opartym na prostowniku sześciopulsowym z normą PN-EN 61000-3-2. Analizuje się różne rodzaje filtrów uwzględniając ich skuteczność, cenę oraz straty mocy wpływające na sprawność całego urządzenia.
EN
The article deals with the problem of compliance of an inverter heat pump with an inverter based on a six-pulse rectifier with EN 61000-3-2. Different types of filters are analyzed, considering their effectiveness, price and power losses affecting the efficiency of the whole device.
PL
W artykule omówiono możliwość zastosowania przesyłu linią prądu stałego w krajowym systemie elektroenergetycznym, co znalazło odzwierciedlenie w obowiązującym planie rozwoju sieci przesyłowej w Polsce na lata 2023-2032. W artykule przedstawiono wyniki wstępnej analizy pracy takiej linii, przy czym rozważono przyłączenia południowego jej krańca w różnych lokalizacjach. Parametrem analizy była moc przesyłana linią HVDC, a wynikiem straty przesyłowe w całym układzie, obciążenie linii przesyłowych w ujęciu średnim oraz występowanie obciążeń maksymalnych.
EN
The article discusses the possibility of using direct current transmission in the national power system, which was reflected in the current transmission network development plan in Poland for 2023-2032. The article presents the results of a preliminary analysis of the operation of such a line, considering various connection points of its southern and in different locations. The analysis parameter was the power transmitted by the HVDC line, and the result was transmission power losses in the entire system, average load on transmission lines and the occurrence of maximum loads.
EN
Power converters inherently display non-linear load characteristics, resulting in a high level of mains harmonics, and hence the necessity of implementing Power Factor Correction (PFC). Active PFC circuitry typically comprises an inductor and a power switch to control and alter the input current so that it matches, in shape and phase, the input voltage. This modelling of the waveforms can be performed by means of distinct conduction modes of the PFC inductor. The digital controller implemented in the constructed and investigated boost-type PFC converter can be programmed to operate in discontinuous conduction mode (DCM), continuous conduction mode (CCM), or a combination of the two. The individual modes of operation, via distinct PFC inductor current waveforms, impact the overall efficiency of power conversion and, by extension, temperature distribution in the magnetic component. This paper investigates how the examined conduction modes bear on distinct power-loss mechanisms present in the PFC inductor, including high-frequency eddy-current-generating phenomena, and the fringing effect in particular. As demonstrated herein, the DCM operation, for the set output power level, exhibits exacerbated power dissipation in the winding of the inductor due to the somewhat increased RSM value of the current and the intensified fringing magnetic flux at an air gap. The latter assertion will undergo further, more quantitatively focused research. Finally, the construction of the coil was optimised to reduce power loss by diminishing eddy-current mechanisms.
PL
Przetwornice impulsowe z natury charakteryzują się nieliniową charakterystyką obciążenia, co skutkuje wysokim poziomem harmonicznych prądu wejściowego, a co za tym idzie koniecznością korekcji współczynnika mocy PFC (ang. Power Factor Correction). Aktywne układy PFC mają zazwyczaj w swojej budowie element indukcyjny (cewka PFC) oraz klucz elektroniczny w formie tranzystora, które kontrolują i modyfikują prąd wejściowy, tak aby odpowiadał on kształtem i fazą napięciu wejściowemu. Modelowanie przebiegu prądu zwykle jest realizowane za pomocą kilku odmiennych trybów pracy (przewodzenia) cewki PFC. Cyfrowy układ elektroniczny zaimplementowany w konstruowanej i następnie badanej przetwornicy PFC podnoszącej napięcie (ang. Boost/Step-up converter) jest programowalny do pracy w trybie nieciągłego prądu DCM (ang. Discountinuous Conduction Mode), ciągłego prądu CCM (ang. Countinuous Conduction Mode) lub w ich połączeniu. Poszczególne tryby pracy, a dokładnie różne przebiegi prądu cewki PFC, wpływają na sprawność przetwornicy PFC, a co za tym idzie, na straty mocy i rozkład temperatury w elemencie indukcyjnym. W artykule przedstawiono, w jaki sposób badane tryby pracy wpływają na różne mechanizmy rozpraszania mocy występujące w uzwojeniu cewki PFC, w tym na występujące dla relatywnie wysokich częstotliwości zjawiska generujące prądy wirowe, a w szczególności na zjawisko strumienia rozproszenia przy szczelinie powietrznej. Jak zademonstrowano, tryb pracy typu DCM, dla danego obciążenia przetwornicy, wykazuje wyższe straty mocy w uzwojeniu cewki PFC ze względu na powiększoną wartość skuteczną prądu RMS (ang. Root-Mean-Square) i wzmożony oddziaływanie zjawiska strumień magnetycznego rozproszenia przy szczelinie powietrznej. Ostatnia teza będzie przedmiotem dalszych, ukierunkowanych ilościowo działań badawczych. W ostatnim etapie badań zoptymalizowano konstrukcję uzwojenia cewki, aby zmniejszyć straty mocy poprzez zredukowanie mechanizmów generowania prądów wirowych.
EN
Among the plans of Ministry of Electricity MOE in Iraq to evolve the power distribution sector is to replace the conventional 33/11/0.416 kV system by a new 33/0.416 kV system. The main reasons for that are the huge increase in demand for electricity especially in city center where the demand is increasing vertically for the same geographical area, and the lack of available locations to install additional 33/11 kV substations. This work presents the design of distribution network with proposed 33/0.416 kV system for reliable power supply with better voltage profile, improved power factor, lower losses, and lower cost. The method involves local zoning of area, calculating total load, computing total number, size, and location of distribution transformers, and calculating length and size of cables.The 33 kV intermediate station in the proposed system require a land area about 66% less than the area required for the installation of the conventional 33/11 kV substation. This allows installing the 33 kV intermediate stations in locations that provides the best result from the technical point of view. The line loading about 3 times increase when upgrade the operating voltage to 33kV and can be meet the increase load demand in future without needs to install new substation and new distribution feeders. The GIS software is used to locate the distribution transformers and lying of the underground cables. CYME software is used to simulate the electric distribution system and conduct the load flow and other analyses.
PL
Wśród planów Ministerstwa Energii Elektrycznej MOE w Iraku dotyczących rozwoju sektora dystrybucji energii jest zastąpienie konwencjonalnego systemu 33/11/0,416 kV nowym systemem 33/0,416 kV. Głównym tego powodem jest ogromny wzrost zapotrzebowania na energię elektryczną, zwłaszcza w centrum miasta, gdzie popyt rośnie w pionie dla tego samego obszaru geograficznego oraz brak dostępnych lokalizacji do zainstalowania dodatkowych stacji 33/11 kV. W pracy przedstawiono projekt sieci dystrybucyjnej z proponowanym systemem 33/0,416 kV zapewniającym niezawodne zasilanie o lepszym profilu napięciowym, lepszym współczynniku mocy, niższych stratach i niższych kosztach. Metoda obejmuje lokalne strefowanie obszaru, obliczanie całkowitego obciążenia, obliczanie całkowitej liczby, rozmiaru i lokalizacji transformatorów rozdzielczych oraz obliczanie długości i rozmiaru kabli. Stacja pośrednia 33 kV w proponowanym systemie wymaga powierzchni lądowej o około 66% mniejszej niż powierzchnia wymagana do zainstalowania konwencjonalnej podstacji 33/11 kV. Pozwala to na zainstalowanie stacji pośrednich 33 kV w lokalizacjach zapewniających najlepszy wynik z technicznego punktu widzenia. Obciążenie linii wzrasta około 3 razy po podniesieniu napięcia roboczego do 33kV i może w przyszłości zaspokoić rosnące zapotrzebowanie na obciążenie bez konieczności instalowania nowej podstacji i nowych linii dystrybucyjnych. Oprogramowanie GIS służy do lokalizacji transformatorów rozdzielczych i układania kabli podziemnych. Oprogramowanie CYME służy do symulacji systemu dystrybucji energii elektrycznej i przeprowadzania przepływu obciążenia oraz innych analiz.
7
Content available Some aspects of electromagnetic field shielding
EN
The paper deals with the electromagnetic field shielding both at low and high frequency. At the low frequency the goal of shielding is to regulate the distribution of electromagnetic field in order to either minimizing the power losses in the iron (steel) parts of the device in question. The main practical aim of the shielding at the low frequency electromagnetic field is to avoid the state of overheating. At the high frequency the shielding is mainly dedicated to limit the radiation from the electromagnetic sources and the protection of electronic devices. In some extreme cases the shielding has to protect the humans against electromagnetic field.
PL
Artykuł dotyczy problematyki ekranowania pola elektromagnetycznego, zarówno dla niskich jak i wysokich częstotliwości. W problemach niskoczęstotliwościowych celem ekranowania jest właściwe sterowanie polem elektromagnetycznym w celu zminimalizowania strat energii w urządzeniu, co praktycznie sprowadza się do unikania stanu przegrzania elementów metalowych. W sytuacjach wysokoczęstotliwościowych ekranowanie ma na celu ograniczenie emisji pola elektromagnetycznego , a także ochrony urządzeń elektronicznych przed działaniem pola elektromagnetycznego. W sytuacjach ekstremalnych ochrona tak może dotyczyć ludzi.
EN
Article deals with measurements of performance and analysis of power losses of two switched reluctance motors with a soft magnetic composite core made of iron powder and a laminated Fe-Si steel core. The first one is a prototype motor whereas the second is a commercial one applied in washing machines. Both motors were supplied from a prototype controller. The commercial motor at low rotational speed develops higher torque and power than the prototype, whereas, inversely at high speed. Efficiency for prototype motor is higher for a whole range of rotational speed.
PL
W artykule przedstawiono wyniki pomiarów eksploatacyjnych i analizę strat mocy dwóch silników reluktancyjnych przełączalnych różniących się materiałem rdzenia magnetycznego. W pierwszym przypadku jest to proszkowy kompozyt magnetyczny, natomiast w drugim krzemowe blachy eletrotechniczne. Prototypowy i komercyjny silnik do pralki automatycznej były zasilane natomiast z prototypowego sterownika. Komercyjny silnik dla niskich prędkości obrotowych osiąga większy moment i moc niż silnik prototypowy, dla wyższych odwrotnie. Sprawność silnika prototypowego jest większa niż silnika komarcyjnego dla całego zakresu prędkości obrotowych.
EN
The medium voltage underground cable sheaths are usually bonded and earthed in every substation on the cable route. This results in additional power losses in the sheaths. The paper presents an idea of reducing power losses caused by sheaths cross-bonding. The idea of sheaths cross-connecting only in selected MV/LV substations is given instead of a typical solution, where sheaths cross-bonding requires installing additional joints on the cable route. It leads to a significant power losses reduction while investment cost remains low. Two cases are analysed in the paper: a theoretical simple radial network and a part of a real open-loop network. A significant power losses reduction was obtained in both cases.
PL
Żyły powrotne kabli średniego napięcia są zazwyczaj łączone ze sobą i uziemiane w każdej stacji na trasie linii kablowej. Skutkuje to dodatkowymi stratami mocy w żyłach powrotnych. Referat przedstawia ideę ograniczenia tych strat poprzez zastosowanie przeplotu żył powrotnych. Proponowana jest jednak metoda wykonania połączeń cross-bondingowych jedynie w wybranych stacjach SN/nn, a nie za pomocą instalowania dodatkowych muf na trasie kabla. Powoduje to zmniejszenie strat mocy przy niewielkim nakładzie środków finansowych. W referacie rozważane są dwie sieci – sieć teoretyczna oraz fragment sieci rzeczywistej. W obu analizowanych przypadkach osiągnięto istotne zmniejszenie strat mocy.
EN
Power magnetics in the energy storage configuration are not able to handle a significant amount of power without the introduction of a physical discontinuity in their magnetic path. This frequently takes the form of a discrete air gap giving rise to certain consequences such as extra power dissipation in the coils mounted on gapped cores. The ascertainment of the impact of the fringing magnetic field at the air gap on the efficiency of power conversion is highly problematic due to the complex nature of the phenomenon. The fringing-effect power loss typically coexists and is combined with all the other power-dissipation mechanisms, which greatly complicates the extraction of losses brought about solely by the fringing flux at the air gap from the total amount of dissipation in a given magnetic component. Magnetic cores of composite materials do not require a discrete air gap, as the air gap in them is distributed throughout the entire material, thus preventing the fringing magnetic flux from forming. However, there is a downside to this approach, as power loss in the material is comparably greater and so are the manufacturing costs. As shown here, distributed-gap-type core materials, due to the absence of physical discontinuity, and hence the lack of registerable fringing-effect power loss, can be utilized to comparatively ascertain and extract the extra power dissipation due to the fringing effect phenomenon in gapped magnetic components.
PL
Elementy indukcyjne konwertujące i magazynujące moc elektryczną nie są w stanie przetworzyć znacznej ilości mocy bez wprowadzenia fizycznej nieciągłości w przestrzeń ich obwodów magnetycznych. Przerwa ta często przybiera formę dyskretnej szczeliny powietrznej, co pociąga za sobą pewne następstwa głównie w postaci dodatkowych start mocy w uzwojeniach tak skonstruowanych elementów indukcyjnych. Oszacowanie wpływu rozproszonego pola magnetycznego przy szczelinie powietrznej na sprawność przetwarzania energii jest bardzo problematyczne przede wszystkim ze względu na złożony charakter zjawiska. Ta dodatkowa strata mocy występuje zwykle wspólnie i łączy się z pozostałymi mechanizmami rozpraszania mocy, co znacznie komplikuje ekstrakcję strat spowodowanych wyłącznie przez strumień rozproszonego pola magnetycznego przy szczelinie powietrznej z całkowitej mocy rozproszonej w danym elemencie indukcyjnym. Rdzenie magnetyczne z materiałów kompozytowych nie wymagają dyskretnej szczeliny powietrznej, gdyż szczelina powietrzna jest w nich rozłożona w objętości całego materiału, a tym samym brakuje fizycznego mechanizmu powodującego powstawanie strumienia rozproszenia. Rozwiązanie to ma jednak wadę w postaci zwiększonych strat w materiale rdzenia. Jak zademonstrowano, rdzenie o szczelinie rozproszonej nie wykazują strat mocy spowodowanych strumieniem rozproszenia, a tym samym mogą stanowić podstawę do wyodrębnienia strat mocy wyłącznie z powodu tego zjawiska w elementach indukcyjnych z dyskretną szczeliną powietrzną.
EN
In this work, the temperature dependence of motor resistive losses has been analytically evaluated by using a quantum mechanical approximation. It is well known that the Bloch-Gruneisen approximation is a fundamental quantum theory to the study of the resistivity of the conductor with the change of temperature by using analytical formulation. By using the proposed method, the motor resistive losses can be controlled with respect to the temperature changes. The accuracy of the proposed algorithm has been tested by comparison with different theoretical approaches. It is demonstrated that the new analytical method for the motor resistive losses controlled with the change of temperature will be used for improving motor power and mechanical systems.
EN
The paper presents a proposition of the theoretical-experimental method of determination of power losses in the transversely vibrating rubber V-belt of continuously variable transmission. The article comprises the results of experimental tests conducted on a special test stand with a complete scooter drivetrain powered by a small two-stroke internal combustion engine. Such a configuration allows ensuring real CVT working conditions. A high-speed camera was used for the contactless measurement of belt vibrations and time-lapse image analysis was performed in dedicated software. An axially moving Euler–Bernoulli beam was assumed as the mathematical model. Longitudinal vibrations and nonlinear effects were omitted. Additionally, it was assumed that the belt material behaves according to the Kelvin–Voigt rheological model. Analysis of the damped free vibrations of the cantilever beam, made of the belt segment, allowed to determine the equivalent bending damping coefficient. The CVT power losses, due to bending in the rubber transmission belt, were obtained for the fixed working conditions after numerical calculations. The proposed methodology is a new approach in this research area, which allows to obtain results impossible to achieve with other measurement methods.
EN
This study investigates the installation of multiple droop-controlled distributed generator (DG) sites in an Autonomous Microgrid (AMG) to mitigate power losses. The methodology employs a differential evolution algorithm integrated with a modified backward-forward sweep load flow method to optimise the DG sizing and positioning. Tested on an IEEE 33-bus AMG, the results show a significant reduction in power losses with multiple DG placements, highlighting the potential to improve microgrid performance.
PL
Przedstawiono analizę umiejscowienia generatorów rozproszonych (DG) w izolowanej mikrosieci (AMG), z regulowanym statyzmem oraz z rozwiniętą strukturą hierarchiczną w celu redukcji strat mocy. Metoda wykorzystuje algorytm ewolucji różnicowej zintegrowany z modyfikowaną metodą rozpływu mocy w celu optymalizacji rozmiaru i pozycjonowania DG. Przetestowane na 33-węzłowej mikrosieci testowej IEEE wyniki ukazują znaczącą redukcję strat mocy dzięki optymalnym lokalizacjom DG, wskazują na potencjał poprawy wydajności pracy mikrosieci.
PL
Przedstawiono analizę umiejscowienia generatorów rozproszonych (DG) w izolowanej mikrosieci (AMG), z regulowanym statyzmem oraz z rozwiniętą strukturą hierarchiczną w celu redukcji strat mocy. Metoda wykorzystuje algorytm ewolucji różnicowej zintegrowany z modyfikowaną metodą rozpływu mocy w celu optymalizacji rozmiaru i pozycjonowania DG. Przetestowane na 33-węzłowej mikrosieci testowej IEEE wyniki ukazują znaczącą redukcję strat mocy dzięki optymalnym lokalizacjom DG, wskazują na potencjał poprawy wydajności pracy mikrosieci.
EN
This study investigates the installation of multiple droop-controlled distributed generator (DG) sites in an Autonomous Microgrid (AMG) to mitigate power losses. The methodology employs a differential evolution algorithm integrated with a modified backward-forward sweep load flow method to optimise the DG sizing and positioning. Tested on an IEEE 33-bus AMG, the results show a significant reduction in power losses with multiple DG placements, highlighting the potential to improve microgrid performance.
PL
Na przykładzie dwóch transformatorów olejowych grupy III przedstawiono w artykule dwa kryteria determinujące wymianę transformatorów na nowe. Transformator o mocy znamionowej 670 kVA z roku 2006 zasilał, przez falownik AC/DC/AC piec indukcyjny. Transformator po 5 latach eksploatacji miał zużytą izolację. Konieczność wymiany transformatora na nowy determinowało kryterium zużytej izolacji. Degradacja izolacji była spowodowana impulsami napięcia generowanymi w czasie komutacji zaworów energoelektronicznych. Drugi transformator o mocy znamionowej 400 kVA z roku 1964 ma straty mocy jałowe 2,7 razy większe, a straty obciążeniowe 1,5 raza większe od strat w transformatorach o tych samych parametrach produkowanych obecnie. Wymianę transformatora na nowy determinowało kryterium energii strat w transformatorze.
EN
Two criteria determining the replacement of transformers with new ones are presented on the example of two group III oil transformers. A 670 kVA transformer from 2006 powered an induction furnace via an AC / DC / AC inverter. The transformer after 5 years of operation had worn insulation. The necessity to replace the transformer with a new one determined the criterion of used insulation. Insulation degradation was caused by voltage pulses generated during commutation of power electronic valves. The second transformer with a rated power of 400 kVA from 1964 has an idle power loss 3 times greater and load losses 1,5 times greater than losses in transformers with the same parameters currently produced. Replacement of the transformer with a new one was determined by the criterion of energy loss in the transformer.
PL
W artykule przedstawiono podstawy teoretyczne wyznaczania strat mocy oraz obciążalności transformatorów energetycznych przy obciążeniu prądem odkształconym od przebiegu sinusoidalnego. Przedstawiono także wyniki badań pomiarowych wykonanych w dwóch rzeczywistych obiektach: zakładzie drukarskim oraz budynku biurowym.
EN
This paper presents the theoretical basis for the calculation of power losses and load capacity of power transformers with non-sinusoidal load. The results of measurements carried out in two real objects: a printing plant and an office building are also presented.
17
Content available Straty mocy w liniach kablowych wysokiego napięcia
PL
W artykule przedstawiono metodę wyznaczani strat mocy w kablach energetycznych wysokiego napięcia modelowanych fazowo, dla dowolnej konfiguracji kabli (układ płaski, trójkątny, mieszany, dowolny). Uwzględniono układ pracy z jednostronnym (SPB) i dwustronnym (BE) uziemieniem ekranów. W opracowanym modeli i bazującym na nim oprogramowaniu do analizy strat mocy uwzględniono przeplatanie przewodów roboczych lub ich ekranów oraz możliwość występowania przewodów ECC w konfiguracji SPB i BE.
EN
The article presents a method of determining power losses in phase-modeled high-voltage power cables, for any cable configuration (flat, triangular, mixed, arbitrary). A system of work with single point bonding (SPB) and both-ends bonding (BE) of shield grounding is included. In the developed models and the software based on it for the analysis of power losses, the interlacing of working conductors or their screens and the possibility of the presence of Earth Continuity Conductor (ECC) cables in SPB and BE configurations were taken into account.
PL
Artykuł dotyczy transformatorów energetycznych olejowych grupy III, w których izolacja uzwojeń standarddowo jest papierowo-olejowa i które pracują kilkadziesiąt lat. Transformator olejowy grupy III o mocy znamionowej 1000 kVA z roku 1970 ma parametry oleju świadczące, że izolacja jest w dużym stopniu zużyta. Sprawność transformatora jest równa 98,435%. Zgodnie z wymaganiami Rozporządzenia Komisji (UE) 201911783 obowiązującym od 01.07.2021 r. sprawność transformatora nowego wynosi 98,837%. Zużycie izolacji i straty mocy determinują wymianę transformatora na nowy.
EN
A group III oil transformer of 1,000 kVA rated power from 1970 has oil parameters that indicate that the insulation is largely worn out. The transformer has an efficiency of 98.435%. In accordance with the requirements of the Commission Regulation (EU) 201911783 in force from 01/07/2021. the efficiency of a new transformer is 98.837%. Insulation consumption and power losses determine the replacement of the transformer with a new transformer.
EN
This paper presents a new multilevel inverter topology which can generate all required numbers of levels at the output stage. The proposed topology is composed of six unidirectional switches, several bidirectional switches, and DC voltage sources. To add perspective, the proposed topology is compared with other topologies. The comparison shows that the proposed topology generates more voltage levels without the need for all excess number of switches and DC voltage sources. Moreover, the smaller number of switches in the current flow leads to decreased conductive loss in the proposed topology. To assure the proposed topology operates correctly, it is simulated with the aid of PSCAD/EMTDC software and the results are discussed.
20
Content available Straty mocy i sprawność transformatorów
PL
W artykule zdefiniowano sprawność energetyczną transformatorów. Stały postęp technologii blachy transformatorowej owocuje obniżeniem stratności i wzrostem indukcji nasycenia rdzenia. Stwarza to warunki do zmniejszenia masy rdzenia i w mniejszym stopniu zmniejszenia masy uzwojenia. Podano przykłady strat mocy jałowych i obciążeniowych transformatorów rozdzielczych produkowanych w latach 60. XX w. i produkowanych obecnie. Od 01 lipca 2021 r. Komisja Unii Europejskiej [8] i Normy Europejskie [6,7] ustaliły dalsze obniżenie strat mocy i zwiększenie sprawności w instalowanych transformatorach.
EN
The article defines the energy efficiency of transformers. The constant advancement in transformer sheet technology results in a reduction in loss and an increase in core saturation flux density. This creates conditions for reducing the core mass and, to a lesser extent, for reducing the winding mass. Examples of noload and load losses of distribution transformers manufactured in the 1960s and currently manufactured are given. From 01 July 2021, the European Union Commission [8] and European Standards [6,7] have established a further reduction of power losses and an increase in efficiency in installed transformers.