EN
The conventional approach to electrical safety under fault condition in typical power systems considers earth fault currents of sinusoidal waveform and frequency of 50‒60 Hz. However, in circuits with variable-speed drives, there is earth fault current flow with harmonics, and these harmonics influence the threshold of ventricular fibrillation. The paper presents earth fault current waveforms in circuits with variable-speed drives without inverter output (motor) filter and with one of the two types of inverter output filters being used. The details of both filters are presented, and the effect of harmonics of earth fault current on ventricular fibrillation is evaluated. Furthermore, the effect of harmonics, which occurs in circuit of variable-speed drive, on the tripping current of residual current devices is presented. Residual current devices may be utilized to ensure protection against direct and indirect contact, but limitations in their proper operation, due to harmonics, may exist. Operational characteristics of a proposed residual current device dedicated to circuits with earth fault current containing harmonics, as in the variable-speed circuits, are presented.
PL
W artykule zaprezentowano współczesne kierunki rozwoju energoelektroniki, w tym w szczególności dotyczące obiektów morskich. Przedstawiono podstawowe parametry aktualnie stosowanych w energoelektronice przyrządów półprzewodnikowych, jak również wykazano interdyscyplinarny charakter rozwoju tej dziedziny. Na przykładzie wybranych urządzeń energoelektronicznych przedstawiono ich komercyjne zastosowania oraz podział i miejsce w łańcuchu od wytwórcy energii elektrycznej do odbiorcy. W dalszej części artykułu przedstawiono wybrane zastosowania urządzeń energoelektronicznych na obiektach morskich (statkach, platformach wiertniczych). W końcowej części szczegółowo omówiono przekształtniki energoelektroniczne dużej mocy, w które wyposażane są elektryczne napędy główne na statkach – przedstawiono ich zalety i wady.
EN
This paper presents current trends in the development of power electronics of offshore objects, basic parameters currently used in power semiconductor devices and the interdisciplinary nature of the development of this field of study. Some examples of power electronic devices are used in order to show their commercial application and their place in the chain from the power plant to the recipient. Selected applications of power electronic devices selected for offshore objects (e.g. ships, oil platform) are presented in addition to detailed elaboration about the high-power power converters, in which main electric motors on ships are equipped with – their advantages and disadvantages are presented in the final section of this paper.
3
Content available remote Zagrożenie migotaniem komór serca przy odkształconym prądzie rażeniowym
PL
Przedstawiono zasady wyznaczania równoważnej wartości skutecznej prądu sinusoidalnego, który ze względu na migotanie komór serca wywoła takie same skutki, jak prąd odkształcony. Przeanalizowano wybrane przebiegi wyprostowane, przebiegi o sterowaniu fazowym oraz przebieg prądu ziemnozwarciowego silnika indukcyjnego zasilanego z przemiennika częstotliwości.
EN
The principles of calculation of sinusoidal current, equivalent in terms of ventricular fibrillation, have been presented. The analysis of some rectified currents, phase controlled currents and earth fault current in motor circuit supplied via frequency converter was performed.
4
Content available remote Idealny bezszczotkowy silnik prądu stałego wzbudzany magnesami trwałymi
PL
W artykule omówiono silnik bezszczotkowy prądu stałego z magnesami trwałymi. Założono przy tym, że jest to silnik 3-fazowy, idealny, z komutatorem elektronicznym w układzie mostka. Tranzystory komutatora elektronicznego są przełączane w sposób dyskretny co 60° elektrycznych. W silniku tym pominięto wpływ indukcyjności oraz założono liniowość i symetrię układu. Szczególną uwagę zwrócono na ogólne algorytmy przełączania zaworów. Wykazano również, że taki silnik charakteryzuje się bardzo dobrymi właściwościami elektromechanicznymi i wysoką sprawnością.
EN
The brushless DC motor with permanent magnets has been discussed in the paper. It is assumed that we have a three-phase ideal motor with linearity and symmetry of the circuit, whose inductance impact has been disregarded. The motor is connected with the electronic commutator with particular switching algorithms. It has been proven that this motor is characterized by very good electromechanical properties and high efficiency.
EN
The paper presents the method of control of an induction squirrel-cage machine supplied by a voltage source converter. The presented idea is based on an innovative method of the voltage source converter control, consisting in direct joining of the motor control system with the voltage source rectifier control system. The combined control system gives good dc-bus voltage stabilization. In the applied control system the limits of the reference variables have been introduced. A correction of the estimated machine load torque is proposed. The new proposed solutions are confirmed by mathematical dependences, simulation and experimental results.
EN
In this paper one of the modeling method of digital control systems of power electronics converters is presented. The main task depends on precise mapping phenomenon occurred in real experimental systems. So, we have to take into account for example delays, which are carried in control system by signal sampling, as well as delays of algorithms realized by processor. The chosen results of simulation and also experimental research are shown.
PL
Artykuł przedstawia zastosowania układów energoelektronicznych we współczesnych i przyszłych rozwiązaniach sieci energetycznych wyposażonych w elementy technologii SmartGrid i Vehicle To Grid. Przedstawione zostały także podstawy działania tych technologii z uwzględnieniem ich wpływu na system energetyczny.
EN
The paper introduces application of power electronics devices into the modern and future electric grids equipped with SmartGrid and Vehicle To Grid technology. Fundamentals of operation of these technologies have been described as well as their influence on power system.
EN
The paper has as an objective to combine and disseminate a brief knowledge on generators and power electronics for Wave Dragon MW (WDMW) Power Take Off system. Wave Dragon MW captures power from sea waves by means of low-head turbines and converts it into rotating mechanical power. In recent years because of energy saving problem on almost whole world power electronics and electric machines as well as renewable energy market has been intensively developed. Problems which can appear in conversion mechanical power to electrical power in WDMW can be expected to be similar as in wind turbine. Therefore, state of the art briefly can base on state of the art for wind turbines. However, subject of the mechanical energy conversion from sea waves to electrical energy is not well identified and further research should be curried out.
PL
Artykuł ma na celu zebranie i przedstawienie podstawowych informacji na temat przekształtnika energii fal morskich Wave Dragon MW (WDMW). Ponadto również wstępne wyniki symulacyjne zespołu generator-przekształtnik energoelektroniczny - sieć.
PL
W pracy przedstawiono analizę problemów występujacych w trakcie pomiarów oraz oceny kompatybilności elektromagnetycznej układów zawierających przekształtniki energoelektroniczne. Proponowana metodyka rozwiązywania problemów EMC w tych układach polega na lokalizacji źródeł i dróg rozprzestrzeniania się zakłóceń, na podstawie pomiarów w dziedzinie czasu i częstotliwości oraz ich analizy za pomocą modeli symulacyjnych.
EN
In this paper the problems of Electromagnetic Compatibility achieving and measurements in system with power electronics converters has been presented. The proposed methodology of solving of EMC problems in such systems is based on a localization of sources and path of interference currents. The analyzes have been done on the basis of instantaneous measurements in both the time and the frequency domain and simulation models.
PL
W artykule przedstawiono zasadę działania oraz badania symulacyjne i laboratoryjne układu przekształtnika osiemnastopulsowego o wyjściu stałoprądowym, przeznaczonego zasadniczo do współpracy z niskonapięciową siecią zasilającą. Prezentowany przekształtnik pozwala znacznie zredukować w przebiegu prądu sieciowego niepożądane wyższe harmoniczne, głównie rzędu 11, 13, 17 i 19. Osiemnastopulsową pracę układu osiąga sie dzięki zastosowaniu sprzężonego trójfazowego dławika wstepnego podziału prądu (WPP) oraz zestawu sieciowych dławików sprzężonych (TDS). Efekt działania, oprócz redukcji do około 5% zawartości wyższych harmonicznych w przebiegu prądu zasilajacego, przejawia sie także w postaci uzyskania wartości współczynnika mocy na poziomie 97%. Na uwagę zasługuje również niewielka moc pozorna i rozmiary układu magnetycznego.
EN
A rectifier circuit with 18-pulse performance and dc output for three-phase rectification with capacitive dc-smoothing and connection to the independent low voltage disribution network is presented. This circuit allows for significant reduction of unwanted harmonics, particularly those of 11th, 13th, 17th and 19th order. To get the desired 18-pulse performance, the line-side interphase transformer (LIT) and the current divider transformer (CDT) connections without isolation were applied. The circuit is characterised by nearly sinusoidal line currents and low cost. Under nimonal conditions the distortion content of the line currents is less than 5% and the power factor is better than 97%. The circuit consists of only three line-commutated three-phase diode rectifier bridges and few, moderate sized, magnetic components. The principle of operation, simulation and experimental results of a 2kW rectifier with LIT and CDT system are also presented.