In this paper, a control strategy for real-time operation of a master-slave controlled microgrid is developed. The basic idea of this control strategy is to schedule all dispatchable energy sources available into a microgrid to minimize its operational costs. Control actions are centrally evaluated by solving a two-stage optimization problem formulated to take place on two different time-scales: in the day-ahead and in the real-time. The first one provides a 24-hour plan in advance. It mainly draws up the active power levels that Distributed Energy Resources (DERs) should provide for each quarter hour of the next day by taking into account energy prices of the day-ahead energy market, the forecasted energy production of non-dispatchable renewables and loads. The real-time optimization problem updates the active power set-points of DERs in order to minimize as much as possible the real-time deviations between the actual power exchanged with the utility grid and its scheduled value. The effectiveness of the proposed methodology has been experimentally tested on an actual microgrid.
2
Content available remote Koncepcja wirtualizacji usług zabezpieczeniowych w stacjach elektroenergetycznych
PL
Artykuł opisuje koncepcję technologii wirtualizacji, które mogą posłużyć do stworzenia nowej generacji Inteligentnych Urządzeń Elektronicznych (IED). Przegląd koncepcji został oparty o rozwiązania informatyczne stosowane w konwencjonalnych systemach informatycznych. Poddano analizie rozwiązania platform witalizacyjnych firm VMware oraz Microsoft pod kierunkiem wykorzystania w urządzeniach IED.
EN
The article describes the concept of virtualization technology, which can be used to create a new generation of Intelligent Electronic Devices (IEDs). The presented overview of the concept was based on well-known virtualization concepts used in conventional systems. The VMware and Microsoft platforms are analyzed under their potential application for IEDs virtualization.
EN
The submitted paper presents the results of research on the development of a monitoring system for HV power transformers using the IEC 61850 communication standard. The characteristic feature of this system is its implementation on Linux-based programmable PLC. Data registration functionality, aggregation, archiving and data visualization are merged on one controller. Data registration is performed through built-in digital and analogue input cards, Ethernet and serial ports used for communication with external devices. Data aggregation and archiving is based on the MySQL database system, through data visualization and presentation thanks to an in-built HTML server with an implemented HTML web page that shows the most important parameters in real time. In addition, the implemented IEC 61850 stack enables a direct communication with the SCADA system. The stack has been implemented within the controller in such a way that the need for additional equipment, such as standard machine translation, is reduced. Both the device and all the algorithms developed in the Institute of Electrical Engineering allow collecting and recording the signals in real time, and moreover make a preliminary diagnosis of the transformer.
PL
Artykuł zawiera wyniki badań nad opracowaniem systemu monitoringu transformatorów najwyższych mocy wykorzystującego standard IEC 61850. Cechą charakterystyczną opisywanego systemu jest jego implementacja na programowalnym sterowniku PLC, bazującym na systemie Linux. W jednym sterowniku została połączona funkcjonalność rejestracji, agregacji, archiwizacji i wizualizacji danych.
EN
The paper describes schemes of modern digital protection automation devices using Ethernet technology as the main medium of exchange of information, which allows building a communication architecture for a power system, using all aspects of the IEC 61850 standard.
PL
W artykule opisano konstrukcje nowoczesnych urządzeń cyfrowej automatyki zabezpieczeniowej, wykorzystujących technologie Ethernet jako główne medium wymiany informacji. Pozwala to na zbudowanie architektury komunikacyjnej systemu elektroenergetycznego, wykorzystującej wszystkie aspekty standardu IEC 61850.
EN
The article describes the travelling wave fault location algorithm for high voltage lines based on wavelet transform. The algorithm is implemented in a prototype and tested in the laboratory. The article presents the hardware and software part of a travelling wave fault locator, methodology and test results.
PL
W artykule opisano algorytm falowej lokalizacji miejsca zwarcia w linii wysokiego napięcia (WN) oparty na przekształceniu falowym zaimplementowany w prototypie urządzenia, a następnie przetestowano w warunkach laboratoryjnych. Artykuł przedstawia opis części sprzętowej i programowej falowego lokalizatora, metodykę oraz wyniki testów.
PL
Źródła gazowe, w warunkach polskich, mają obecnie małe znaczenie dla wytwarzania energii elektrycznej. Z drugiej zaś strony, od wielu już lat, w kolejnych dokumentach rządowych, takich jak „Polityka energetyczna Polski”, przewiduje się znaczący wzrost zużycia gazu do produkcji energii elektrycznej i ciepła. W referacie omówiono problematykę rozwoju źródeł gazowych oraz ich wpływu na regulację częstotliwości i mocy. Rozważania teoretyczne zostały wzbogacone badaniami symulacyjnymi, w których przeanalizowano wpływ struktury wytwarzania na właściwości dynamiczne sytemu elektroenergetycznego, w zakresie regulacji częstotliwości.
EN
Gas sources are now of minor importance for the generation of electricity in Poland. For many years, according to the subsequent government documents such as the "Polish Energy Policy", a significant increase in gas consumption to produce electricity and heat is expected. Presented paper discusses the problems of the development of gas resources and their impact on the load frequency control. The problem of wind generation impact on load and frequency control is explicitly detailed. Accompanying simulations are included in order to clarify the theoretical basis presented in the first sections of the paper. Simulations show the impact of gas sources on frequency quality control and dynamical features of power systems under the angle of frequency control.
7
Content available Falowa lokalizacja miejsca zwarcia w linii WN
PL
W artykule porównano metody impedancyjne i falowe, wykorzystywane do lokalizacji miejsca zwarcia w linii wysokiego napięcia, przedstawiono podstawowe zagadnienia związane z rozpatrywaniem zjawisk falowych, opisano falowe metody pomiarowe oraz poszczególne elementy wchodzące w skład układów pomiarowych falowych lokalizatorów.
PL
W artykule przedstawiono krótką dyskusję dotyczącą definicji generacji rozproszonej. Nakreślono stan obecny oraz perspektywy rozwoju generacji rozproszonej w Polsce. Opisano możliwości pozyskania jednostek generacji rozproszonej do celów sterowania pracą systemu elektroenergetycznego, poprzez świadczenie usług systemowych.
EN
This paper presents a method for the short-circuit parameter estimate in a network including wind power plants. The originality of the method consists in the treatment of wind generators (as well as whole farms) as current sources that “inject” to grid network in the connection node an inductive current being a multiple of the rated current of a single generator (or a group of generators, respectively). This behaviour occurs when the voltage in the generator connection point has dropped below a certain level. Thus, the traditional generator short-circuit model in the form of electromotive force is replaced with a voltage-controlled current source.
9
Content available remote Internal interactions of UPFC multifunction controller
EN
Interactions between controllers are one of the main reasons of weakly damped oscillations in power systems. This phenomenon is mostly due to either their inadequate tuning or the lack of coordination of their action. The analysis of the problem becomes much more complicated in case of using FACTS-based multifunctional controllers. In such a situation other reasons of control interactions could appear. This paper presents an analysis of internal interactions occurring during the multifunction operation of Unified Power Flow Controller (UPFC) installed a multimachine test system. The analysis is performed using relative gain array and generalised dynamic relative gain.
PL
Interakcje regulatorów są jedną z głównych przyczyn słabo tłumionych oscylacji pojawiających się w systemie elektroenergetycznym. Zjawisko to występuje głównie w wyniku niewłaściwego doboru parametrów regulatorów lub braku koordynacji ich działania. Analiza problemu interakcji jest szczególnie złożona w przypadku wielofunkcyjnych regulatorów urządzeń FACTS. W tym przypadku również inne przyczyny mogą powodować występowanie interakcji w układzie regulacji. Artykuł przedstawia analizę wewnętrznych interakcji powstających w wyniku działania wielofunkcyjnego regulatora urządzenia UPFC w wielomaszynowym systemie elektroenergetycznym. Analiza interakcji została przeprowadzona z wykorzystaniem metody macierzy względnego wzmocnienia oraz metody uogólnionego względnego dynamicznego wzmocnienia.
EN
A new concept of mathematical model of multimachine power system is presented. This model was used to analyse the steady-state stability of power system. A set of algebraic and differential equations, which led to the elaboration of the model, has been drived. The following linearised mathematical model of power system has been taken in consideration: 5th order mathematical model of generators, simple mathematical models of excitation control and AVR, models of power system stabilisers and network with additional constant impedances as load model. It was proved that it is possible to elaborate a more accurate mathematical model of power system considering the influence of voltage sensitibity of the loads on the steady-state stability of electrical power system.
PL
Artykuł dotyczy koncepcji tworzenia nowego modelu matematycznego systemu elektroenergetycznego do badania stabilności lokalnej przy wykorzystaniu modelu matematycznego 5. rzędu generatorów synchronicznych, modeli układów wzbudzenia, stabilizatorów systemowych i sieci elektroenergetycznej. Wprowadzono zależności algebraiczno-różniczkowe pozwalające na tworzenie modelu matematycznego 5. rzędu generatorów, układów wzbudzenia i regulacji napięcia stabilizatorów systemowych oraz sieci elektroenergetycznej przy zastosowaniu dokładniejszego modelu odbiorów, uwzględniającego ich podatność napięciową. Podstawowym problemem rozwiązanym w tej pracy jest włączenie tego nowego modelu odbioru do modelu matematycznego systemu elektroenergetycznego.