In the article, a new light reflectance model is proposed. The model is based on the modified cosine-quadratic bidirectional reflectance distribution function. The concept of bidirectional reflectance distribution function is analyzed. The disadvantages of existing physically accurate and empirical bidirectional reflectance distribution functions, including classical cosine-quadratic function, are discussed. The necessity of new empirical distributive functions development is justified. The comparison of double integrals of hemispherical reflectivity of reference Blinn function and classical cosine-quadratic function is provided. Based on the comparison, the new expression of cosine-quadratic distributive function calculation is obtained. The proposed expression makes it possible to significantly increase the accuracy of glare epicentre reproduction and is intended for use in highly productive three-dimensional rendering systems.
PL
W artykule zaproponowano nowy model odbicia światła. Model ten opiera się na zmodyfikowanej dwukierunkowej funkcji rozkładu odbicia. Przeanalizowano koncepcję dwukierunkowej funkcji rozkładu odbicia. Rozważono główne niedociągnięcia istniejących, fizycznie dokładnych i empirycznych dwukierunkowych funkcji rozkładu odbicia, w szczególności klasycznej funkcji cosinus-kwadratowej. Uzasadniono potrzebę opracowania nowych empirycznych funkcji rozkładu. Dokonano porównania całek podwójnych współczynnika odbicia półkulistego funkcji odbicia Blinna i standardowej funkcji cosinus-kwadratowej. Na podstawie porównania uzyskano nowe wyrażenie umożliwiające obliczenie funkcji cosinus-kwadratowej. Proponowane wyrażenie pozwala znacząco zwiększyć dokładność odwzorowania epicentrum olśnienia oraz strefy tłumienia olśnienia i jest przeznaczone do stosowania w wysokowydajnych systemach renderowania trójwymiarowego.
2
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Egzystencja coraz liczniejszej populacji człowieka w szeroko pojętym środowisku XXI wieku, prowadzi do zachwiania równowagi w przyrodzie. Poszukiwanie rozwiązań tego problemu wymaga pilnej edukacji oraz działań, w których dużą wagę i nadzieję przypisuje się roli architekta krajobrazu. Edukacja współczesnego człowieka powinna zmierzać w kierunku możliwości wyboru takich rozwiązań i działań, które będą wywierać najmniej negatywne wpływy na otaczające go środowisko. Tego typu działania wymagają przemyśleń w stronę retardacji niekorzystnych przekształceń wszystkich zasobów przyrody. W publikacji opisano przykłady projektowania obiektów architektury zacieniającej przestrzeń.
EN
The existence of an increasingly large human population in the broadly understood environment of the 21st century leads to an imbalance in nature. The pursuit of solutions to this problem requires urgent education and activities in which the landscape architect takes a large role. The education of a modern human should aim at the possibility of choosing such solutions and activities that will have the least negative impact on the surrounding environment. Such activities require reflections towards retardation of unfavourable transformations of all natural resources. This publication describes examples of space shading architectural objects designing.
3
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Instalacja pompy ciepła wraz z wymiennikami gruntowymi korzystnie kształtuje komfort cieplny w pomieszczeniach latem. W artykule sprawdzono, czy zastosowanie w szkole w standardzie pasywnym w Budzowie modyfikacji przyjętych tam rozwiązań konstrukcyjnych i lokalizacyjnych mogłoby wystarczająco ograniczyć przegrzewanie obiektu latem, eliminując w ten sposób potrzebę stosowania systemów chłodzenia. Stosując analizy symulacyjne, w programie Design Builder, rozpatrywano warunki, jakie powstają w przypadku różnych modyfikacji systemów osłon zewnętrznych i wewnętrznych zastosowanych w szkole. Analizie poddano także różne możliwości orientacji wybranej klasy względem stron świata. Dokonano obrotu modelu budynku szkoły, odpowiednio o 90°, 180° i 270°. Symulacje przeprowadzono w okresie dwumiesięcznym, tj. 01.05 - 31.06. Zaprezentowane w artykule wyniki wykazały, iż system wentylacji mechanicznej skutecznie ogranicza przegrzewanie pomieszczeń latem jedynie w połączeniu ze źródłem chłodu w formie gruntowego wymiennika ciepła i pompy ciepła. Pozostałe sugerowane modyfikacje budynku nie są tak efektywne jak chłodzenie gruntowe. W celu obiektywnej oceny warunków komfortu, w artykule zaproponowano odmienny i bardzo prosty sposób szacowania miary dyskomfortu, związanej z przegrzewaniem.
EN
Heat pumps together with ground heat exchangers favorably shape thermal comfort in summer. This study examines whether the use of modifications to the construction and location solutions adopted in a passive standard school building in Budzów could sufficiently reduce overheating in summer, thus eliminating the need for building services. Through simulation in Design Builder, the conditions that arise for various modifications of the exterior and interior insulation systems used in the school were considered. Also analyzed were various possibilities for the orientation of the selected classroom in relation to the cardinal directions. Rotations of the school building model by 90°, 180° and 270° respectively, were done. Simulations were carried out for the two-month period between May 1 and June 31. The results presented showed that the mechanical ventilation system, in combination with a source of cooling in the form of a ground heat exchanger and heat pump, can effectively reduce discomfort in summer on its own. The other suggested modifications to the building, were not as effective as ground cooling. In order to objectively assess comfort conditions, this study proposes a different and very simple way of estimating the measure of discomfort associated with overheating.
In the article themodel of light reflection based on the combination of two cubicbidirectional reflectancedistribution functions is developed.The main components of color and the main requirements for reproducing the object`s glaresareanalyzed. The usage characteristicsof Cook-Torrance, Bagher, Oren-Nayar, coupled Shirley reflection models are described. The advantages and disadvantages of the highly productive Blinn-Phong modelare considered. The necessity of approximating the Blinn-Phong model by a function of low degree is justified. The characteristics of the cubic polynomial approximation of the Blinn-Phong model are determined. It was established that the main drawback of this approximation is a significant deviationof the function from the reference function in the glare’sattenuation zone. Thecombined function that combines two cubic functions is proposed. The first cubic function reproduces the glare’s epicenter, and the second replaces the specified function in the attenuation zone. A system of equationsfor calculating the coefficients of the second function was created. The formula for the connectionpointof two cubic functions is obtained. A graphof the developed combined model based on cubic functions is obtained. For the combined and original cubic functions a comparison of the maximum relative errors in the glare’sepicenterzone, the maximum absolute errors, and the relative errors at the inflection point was made. A three-dimensional plot of the absolute error of the combined cubic model from the Blinn-Phong modeldepending on the shininessand the angle value is built. Visualization results based on the combined and the original cubic functionsare compared. It is confirmed that the proposed reflection model increases the realismof glare formation in the attenuation zone. The resulting combined reflection model provides a highlyaccurate approximation of the Blinn-Phong model and is highly efficient because the third power function is used.
PL
W artykule opracowano model odbicia światła oparty na kombinacji dwóch sześciennych dwukierunkowych funkcji rozkładu odbicia.Przeanalizowano główne składniki koloru i główne wymagania dotyczące odtwarzania odblasków obiektu. Opisano charakterystykę użytkowania modeli odbicia Cooka-Torrance'a, Baghera, Orena-Nayara i Shirleya. Rozważono zalety i wady wysoce wydajnego modelu Blinn-Phong. Uzasadniono konieczność aproksymacji modelu Blinna-Phonga funkcją niskiego stopnia. Określono charakterystykę wielomianu sześciennego aproksymującego model Blinna-Phonga. Ustalono, że główną wadą tej aproksymacji jest znaczne odchylenie funkcji od funkcji odniesienia wstrefie tłumienia olśnienia. Zaproponowano funkcję kombinowaną, która łączy dwie funkcje sześcienne. Pierwsza funkcja sześcienna odtwarza epicentrum olśnienia, a druga zastępuje określoną funkcję w strefie tłumienia. Stworzono układ równań do obliczania współczynników drugiej funkcji. Uzyskano wzór na punkt połączenia dwóch funkcji sześciennych. Uzyskano wykres opracowanego połączonego modelu opartego na funkcjach sześciennych. Dla połączonychi oryginalnych funkcji sześciennych dokonano porównania maksymalnych błędów względnych w strefie epicentrum olśnienia, maksymalnych błędów bezwzględnych i błędów względnych w punkcie przegięcia. Zbudowano trójwymiarowy wykres błędu bezwzględnego połączonego modelusześciennegoz modelu Blinna-Phonga w zależności od połysku i wartości kąta. Porównano wyniki wizualizacji oparte na połączonych i oryginalnych funkcjach sześciennych. Potwierdzono, że proponowany model odbicia zwiększa realizm powstawania odblasków w strefie tłumienia. Wynikowypołączony model odbicia zapewnia bardzo dokładne przybliżenie modelu Blinna-Phonga i jest bardzo wydajny, ponieważ używana jest funkcja trzeciej potęgi.
The paper presents the research on the influence of the connection configuration and the location of the PV cells shading on the output parameters of photovoltaic roof tiles. The problem of shading occurs in all photovoltaic installations, but in the case of solar tiles it can cause much greater power losses than in the case of traditional panels. The series, parallel and series-parallel configurations of photovoltaic roof tiles with different shading locations were tested. The values of roof tiles output parameters, current-voltage and power characteristics of the analyzed systems were presented.
PL
W pracy przedstawiono badania wpływu konfiguracji połączeń oraz lokalizacji zacienienia ogniw PV na parametry wyjściowe dachówek fotowoltaicznych. Problem zacienienia występuje we wszystkich instalacjach z fotowoltaicznymi, jednak w przypadku dachówek solarnych może on powodować znacznie większe straty mocy niż w przypadku tradycyjnych paneli. Przebadano konfiguracje szeregową, równoległą oraz szeregowo-równoległą dachówek fotowoltaicznym z różnymi miejscami wystąpienia zacienień. Przedstawiono wartości parametrów wyjściowych dachówek, charakterystyki prądowo-napięciowe oraz mocowe analizowanych układów.
The presented distributed photovoltaic system is made of divided into individual modules photovoltaic panel, consisting of several photovoltaic cells properly connected and coupling them with low-power DC / DC converters. The essence of the research is to increase the reliability of the system and the resultant efficiency of the entire system, so that it is possible to convert solar radiation energy into electricity with the greatest efficiency. The article focuses on the presentation of the implementation and tests of the overriding control algorithm, the task of which is to provide full functionality for a distributed photovoltaic system. The control is designed to minimize the negative effects of shadows on the operation of the photovoltaic system and conduct self-diagnostics. The conclusion for the carried out work is the formulation of hardware and interface requirements for the further development of the project.
The silvopasture system is an integrated system which has been widespread in tropical and sub-tropical climates. However, there is a lack of detailed studies regarding agroecological silvopasture systems. This study assessed whether the different levels of shading in an agroecological silvopastoral system influences the microclimate and botanical composition of polyphytic pasture. We used eight paddocks composed of a silvopastoral system in a subtropical climate, with different tree species arranged in simple lines with polyphytic pasture. In each paddock, we established three levels of visual shading (under the canopy, intermediate and full sun). The following microclimatic variables were recorded monthly during the daytime: illuminance, air temperature, air relative humidity, wind speed, and surface soil temperature. The samples of forages were separated into grasses, legumes and spontaneous, then fractionated into leaves, stems, and senescent material. We observed lower values of illuminance and surface soil temperature under the canopy, with differences between full sun and under the canopy at noon. Regarding the forage, the percentage of legumes was higher in full sun, and spontaneous species and leaves had high proportions under the canopy. Based on the results, the agroecological silvopastoral system changed the microclimatic characteristics and altered the plant composition of polyphytic pasture.
Na polskim rynku energii fotowoltaika staje się w ostatnich latach coraz bardziej popularna, wzbudzając rosnące zainteresowanie społeczeństwa. W niniejszym artykule zawarto podstawowe informacje na temat fotowoltaiki, a więc innowacyjnej technologii konwersji światła słonecznego na energię elektryczną. Ukazano oraz opisano główne elementy składowe instalacji fotowoltaicznej, a także jej wady i zalety.
EN
In the Polish energy market, photovoltaics has become increasingly popular in recent years, arousing growing interest among the public. This article contains basic information about photovoltaics, i.e. an innovative technology for the conversion of sunlight into electricity. The main components of a photovoltaic installation are shown and described as well as its advantages and disadvantages.
Instalacje fotowoltaiczne coraz bardziej wpisują się w krajobraz Polski. Biorąc pod uwagę geograficzne uwarunkowania naszego kraju, jak również mając na uwadze niekorzystny wpływ zjawiska zacieniania na pracę systemu fotowoltaicznego należy zastanowić się, czy klasyczna struktura elektrowni solarnej jest tutaj najlepszym rozwiązaniem. W niniejszej pracy zaprezentowana została koncepcja elektrowni fotowoltaicznej o tzw. strukturze rozproszonej, polegającej na podziale panelu fotowoltaicznego na mniejsze części. Szczególna uwaga poświęcona została podstawowemu elementowi każdej elektrowni tego typu, czyli ogniwu fotowoltaicznemu, od którego w głównej mierze zależą parametry robocze całego systemu. W rozdziale opisującym dobór parametrów i struktury modułu fotowoltaicznego oraz wyniki jego badań laboratoryjnych pokazano, jak dużą stratę mocy generowanej przez moduł powoduje zacienienie o niewielkich wymiarach – stanowiące tutaj mniej niż 1% powierzchni całego modułu Wykazano również, że poza powierzchnią zacienienia, istotny wpływ na wartość straty mocy ma również położenie miejsca zacienienia.
EN
Photovoltaic installations have blend in the Polish landscape. Taking into account the geography of our country, as well as bearing in mind the negative impact of shading on the operation of photovoltaic systems, it should be considered whether the classic structure of a solar plant is the best solution. In this paper, the concept of power plant based on system of distributed photovoltaic panels is presented. Particular attention is paid to the photovoltaic cell, being a basic element of each power plant of this type, on which the operation parameters of the entire system depend. The chapter describing the selection of solar module parameters and its structure, as well as the results of laboratory tests, shows how much power loss, generated by the module, is caused by shading of a small area (less than 1% of the surface of entire module). It is also shown that, apart from the shaded surface, the location of the shaded space has a significant influence on the value of the power loss.
10
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W pracy przedstawiono wpływ zacienienia na działanie ogniw fotowoltaicznych oraz oddziaływanie cienia na uzysk energii. Dokonano analizy prawdopodobieństwa uszkodzenia paneli fotowoltaicznych. Wykazano możliwości ochrony modułów, sposoby zapobiegania lub zmniejszania efektu zjawiska zacienienia.
EN
The paper presents the effect of shading on the operation of photovoltaic cells and the impact of shadow on energy yield and the likelihood of their damage. The possibilities of module protection, methods of preventing or reducing the effects of shading have been demonstrated.
11
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Jedną z ważniejszych analiz wykonywanych we wczesnych fazach projektowania budynku jest analiza nasłonecznienia, która ułatwia prawidłowe usytuowanie go zgodne z warunkami technicznymi oraz pozwala na wskazanie interesariuszy przyszłej inwestycji. Analizy przesłaniania, zacienienia czy nasłonecznienia poszczególnych elementów budynku mogą być przydatne na różnych etapach realizacji inwestycji. W artykule przedstawiono rodzaje analiz nasłonecznienia, możliwości sporządzania ich w aplikacjach BIM oraz omówiono wpływ słońca, topografii i zieleni na wyniki analiz.
EN
One of the most important analyzes carried out in the early stages of design of the building is the sunshine and shadow analysis than makes it easier to correct in accordance with technical conditions and allow to identify stakeholders of future investment. Analyzing the occlusion, shading or insolation of individual building elements may be useful at different stages of investment implementation. The article presents the types of sunshine analyzes, possibilities of their preparation in BIM applications and discusses the influence of the sun, topography and green on the results of analyzes.
12
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Availability of light to solar cells is crucial for the efficiency of photovoltaic systems. For this reason, even partial shading can result in significant reduction of generated electric power (loss of current). This paper examines the changes in the efficiency of multicrystalline silicon solar cells which are caused by different kinds of shading. Full and partial shading were simulated by the use of three types of shutter-foils printed in a gray and black scale. The measurements of current-voltage characteristics show that totally or partially shaded modules can drastically reduce the generated power. Short circuit current decreases from about 8100 to 100 mA that in the case of the series connection of cells in a module, lead to the shift of the point of the maximum power and finally to the considerable reduction of nominal system photovoltaic power.
14
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Podczas projektowania budynku, projektant musi rozwiązać wiele kluczowych problemów. Jednym z takich problemów jest ustalenie wielkości okien. Prócz rozwiązania kwestii estetycznych, należy się zastanowić jak wielkość okien będzie wpływać na bilans cieplny budynku. Zwiększanie powierzchni przeszkleń z jednej strony zwiększa straty ciepła (współczynnik U okna jest znacznie większy niż ściany, w której okno zlokalizowano – okno posiada mniejsze właściwości izolacyjne), z drugiej potęguje bierne zyski ciepła od promieniowania słonecznego. Zyski takie są pożądane w okresach zimnych (zmniejszają zapotrzebowanie na ciepło pomieszczenia), jednak w okresach letnich mogą powodować nadmierne przegrzewanie. Poniższa praca jest próbą wskazania wielkości okna zewnętrznego elewacji południowej budynku pasywnego. W analizach wykorzystano przykładowy model budynku, a obliczenia prowadzono przy pomocy programu ESP-r. Analizowano różne powierzchnie przeszkleń oraz różne wielkości zacienień okien elewacji południowej. Powierzchnię przeszkleń odnoszono do całkowitej powierzchni ściany zewnętrznej danego pomieszczenia – rozpatrywano przypadki, w których powierzchnia szklenia odpowiadała od 15% do 50% całkowitej powierzchni ściany. Dla każdej wielkości okna prowadzono dodatkowo obliczenia wpływu 4 wielkości zacienień: 0,5 m, 1 m, 1,5 m, 2 m, a także przypadku okna niezacienionego. Badania prowadzono w kierunku określenia zapotrzebowania na energię do ogrzewania oraz chłodzenia. Zgodnie z przewidywaniami zwiększanie udziału przeszklenia ściany zmniejsza się zapotrzebowanie na ciepło pomieszczenia, jednak znacząco wzrasta zapotrzebowanie na energię do chłodzenia.
EN
While designing a building, the designer has to resolve a number of key issues. One of these issues is to determine the size of windows. In addition to solving aesthetic aspect, we should ponder how the windows' size will affect the thermal balance of the building. On one hand, increasing the glazing area increases heat losses (window's U coefficient is much larger than wall's in which the window is located - window has lower insulating properties), but on the other hand it intensifies passive heat gains from solar radiation. Such gains are desired during cold periods (they reduce room's heat demand), however during summer periods they can cause excessive overheating. This research is an attempt to indicate the size of external window of passive building's south facade. In the analysis, the exemplary building model was used and the calculations were carried out with the use of ESP-r software. Various areas of glazing and windows' shading of south facade were analyzed. The glazing surface was compared with the total surface of given room's external wall - the cases in which glazing surface corresponded to 15% to 50% of wall's total surface were considered. For each window's size the additional calculations of the impact of 4 shading sizes: 0,5 m, 1 m, 1,5 m, 2 m, as well as the case of window without shading, were carried out. The research was conducted in the direction of determining energy demand for heating and cooling. As expected, increasing wall's glazing reduces room's heat demand, however, the demand for cooling energy rises.
Podstawowym walorem inwestycji budowlanych jest optymalne wykorzystanie dostępnej przestrzeni - szacowane prawdopodobnymi efektami ekonomicznymi, możliwymi do osiągnięcia w planowanym czasie. Istotną barierę uzyskiwania satysfakcjonujących wyników inwestycyjnych stanowią przepisy techniczne dotyczące, tzw. przesłaniania i zacieniania mieszkań przez projektowane obiekty, w zasięgu których znajdują się mieszkania. Pojawia się zatem problem wyceny wartości, jaką jest dopływ słońca do mieszkania, a więc cena słońca, którą trzeba zapłacić właścicielom mieszkań za częściowe lub całkowite zacienienie mieszkania, a więc obniżenie jego wartości. Pozbawionej jednej z cech jakościowych. Przedstawiono własną metodę i oryginalny wzór obliczania ubytku wartości mieszkań całkowicie lub częściowo zacienionych.
EN
The primary economic quality of architectural design is the optimal use of space - estimated by probable functional results, achievable within the scheduled time. There is a barrier to achieving satisfactory investment results in the form of technical regulations regarding so called obscuring and shading of residential apartments by designer structures in whose vicinity such apartments are located. Owners of obscured apartments demand financial compensation from investors for partial or complete deprivation of sunlight, thereby reducing the value of an apartment. Therefore, there is an issue of estimating the value of sunlight supply to the potentially shaded apartments, i.e. an arbitrarily specified price of sunlight. This report presents a method and original formula for calculating the loss of value of apartments partially or completely deprived of sunlight.
W artykule przedstawiono analizę obciążeń chłodniczych budynku przy uwzględnieniu zmienności czynników wpływających na wielkość zysków ciepła. W celu zminimalizowania zapotrzebowania na chłód określono wpływ elementów zacieniających instalowanych po stronie zewnętrznej na oknach na wielkość mocy chłodniczej niezbędnej do klimatyzacji wybranego budynku. Wielowariantowe obliczenia obciążenia chłodniczego budynku mają na celu określenie wielkości redukcji zapotrzebowania na chłód. Określenie zysków ciepła od nasłonecznienia jest pracochłonne, lecz daje wynik odzwierciadlający wpływ powierzchni przegród przezroczystych, zastosowanych urządzeń przeciwsłonecznych oraz usytuowania budynku względem stron świata, na wewnętrzne zyski ciepła. W niniejszej pracy, wchodzące w skład bilansu zyski ciepła od nasłonecznienia określone są w trzech wariantach zacienienia okien. Aby ograniczyć zużycie anergii elektrycznej w instalacji chłodniczej określono wariant najmniejszego zapotrzebowania na energie potrzebną do funkcjonowania układu chłodzenia. Oszacowano również korzyści wynikające z czasowego niedotrzymania warunków komfortu cieplnego.
EN
The article presents an analysis of the building cooling load taking into account the variability of the factors affecting the size of the heat gains. In order to minimize the demand for cooling, the effect of shading elements installed on the outside on the windows and its effect on size of the cooling capacity of air conditioning system for the building has been estimated. Multivariate building cooling load calculations to determine the size of the reduction in cooling demand has derived. Determination of heat gain from the sun is laborious, but gives a result which reflects the influence of the surface transparent partitions, devices used as sunscreen and its location on the building envelope in relation to the world, as well as to the internal heat gains has great attention in obtained calculation. In this study, included in the balance sheet of solar heat gains are defined in three different shading of windows. To reduce the consumption of electricity energy in the cooling system of the smallest variant identified the need for the power supply for the operation of the cooling system. Also assessed the financial benefits of the temporary default of comfort.
The work presents the components of solar radiation that reaches the horizontal plane and a method of determining the energy value of the radiation that reaches the surface of a photovoltaic receiver inclined to the ground line at a certain angle. A shading assessment diagram and a methodology for determining the vertical angles and the influence of the horizon on the shading of a PV receiver were provided. A method of determining the direct radiation correction factor depending on the horizon line was presented. The influence of light shading on the current and voltage characteristics of a solar module was determined.
PL
W pracy przedstawiono składowe promieniowania słonecznego docierającego do powierzchni horyzontalnej oraz sposób wyznaczenia wartości energii promieniowania padającej na powierzchnię odbiornika fotowoltaicznego nachylonego pod pewnym kątem do ziemi. Zamieszczono diagram oceny cieniowania oraz metodykę wyznaczenia kątów pionowych i wpływu horyzontu na cieniowanie odbiornika PV. Przedstawiono sposób wyznaczania współczynnika korekcyjnego promieniowania bezpośredniego wywołanego linią horyzontu. Określono wpływ słabego cienia na charakterystykę prądowo-napięciową modułu solarnego.
20
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
During the 20th century in Central and Eastern Europe, traditional agricultural management was either heavily intensified or abandoned due to socio-economic reasons. The land abandonment led to subsequent secondary succession reverted many wet meadows into Phragmites swamps, Salix or Alnus thickets, as well as woodlands. Therefore, the understanding of changes in abundance and structure of populations in the process of succession has become very important especially for rare and endangered species. In Poland one of strictly protected plant is Gentiana pneumonanthe L. It is a nonclonal, long-lived, iteroparous plant consisted of numerous vegetative and generative stems, bearing 1–25 flowers per year. The investigations of abundance and structure of subpopulations of Gentiana pneumonanthe were conducted in the years 2009–2011 in abandoned Molinietum caeruleae meadows dominated by low-stature species (Patch I), prevailed by tall grasses (Patch II), willows (Patch III), as well as partly overgrown by shrubs and trees (Patch IV). The average height of vegetation cover achieved from 65.3 cm (Patch I), via 85.8 cm (Patch II) and 94.0 cm (Patch III), to 142.7 cm (Patch IV). The gradually decline of abundance of Gentiana pneumonathe subpopulations and increased trend toward their senilization along the gradient of vegetation height might be due to successional closure of plant cover, preventing seedling recruitment. The total number of stems per individual and length of vegetative stems decreased with augmentation of neighbouring plants dimensions, whereas the height of generative stems, as well as flower and fruit production presented inversed trend. The greatest dimensions of capsules found in patch dominated by small meadow species might be due to greater availability of solar radiation. The conditions of studied subpopulations decrease gradually from patch dominated by small meadow species, via sites prevailed by grasses and willows, to place overgrown by shrubs and trees. Although obvious differences in abundance and structure of individuals, the prospects of all observed populations are poor, especially that patches are not subjected active protection.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.