Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 484

Liczba wyników na stronie
first rewind previous Strona / 25 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  stabilność
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 25 next fast forward last
EN
This paper reviews the legal and regulatory framework in Bosnia and Herzegovina (BiH) for  connecting renewable energy production facilities. It assesses how well BiH’s regulations align  with European Union (EU) standards for grid connections, focusing on stability criteria from the  EU network code for generators. The paper also establishes a theoretical foundation for the transient  stability of distributed generators and presents a verification methodology for distribution system  operators in general. By developing a distribution network model and offering practical examples,  this study aims to enhance the application of stability criteria, which are crucial for managing  grids with high shares of renewable energy sources. This study underscores the importance of  harmonized regulatory frameworks for the successful integration of renewable energy sources  into the BiH power grid, aligning with the Energy Community Treaty objectives. It also identifies  key gaps in the regulatory oversight of distribution networks, offering practical methodologies  for distribution system operators to ensure compliance with stability requirements. Ultimately,  this research provides actionable insights for policymakers, advancing practices for integrating  renewable energy. These findings are essential not only for the sustainable expansion of renewable energy sources and the reliable operation of the distribution network but also for informing  regulatory oversight and ensuring consistent implementation of EU standards across the sector.
PL
W niniejszym artykule dokonano przeglądu ram prawnych i regulacyjnych w Bośni i Hercegowinie  (BiH) w zakresie przyłączania zakładów produkujących energię odnawialną. Oceniono, w jakim stopniu  przepisy Bośni i Hercegowiny są zgodne z normami Unii Europejskiej (UE) dotyczącymi przyłączania do  sieci, koncentrując się na kryteriach stabilności z unijnego kodeksu sieci dla generatorów. Artykuł ustanawia  również teoretyczne podstawy stabilności przejściowej generatorów rozproszonych i przedstawia metodologię  weryfikacji dla operatorów systemów dystrybucyjnych. Opracowując model sieci dystrybucyjnej i oferując  praktyczne przykłady, niniejsze opracowanie ma na celu poprawę stosowania kryteriów stabilności, które  mają kluczowe znaczenie dla zarządzania sieciami o wysokim udziale odnawialnych źródeł energii.  Analiza ta podkreśla znaczenie zharmonizowanych ram regulacyjnych dla udanej integracji odnawialnych  źródeł energii z siecią energetyczną BiH, zgodnie z celami Traktatu o Wspólnocie Energetycznej.  Identyfikuje również kluczowe luki w nadzorze regulacyjnym sieci dystrybucyjnych, oferując praktyczne  metodologie dla operatorów systemów dystrybucyjnych w celu zapewnienia zgodności z wymogami  stabilności. Ostatecznie przeprowadzone badania dostarczają praktycznych spostrzeżeń dla decydentów  politycznych, rozwijając praktyki integracji energii odnawialnej. Ustalenia te są niezbędne nie tylko dla  zrównoważonej ekspansji odnawialnych źródeł energii i niezawodnego działania sieci dystrybucyjnej,  ale także dla informowania o nadzorze regulacyjnym i zapewnienia spójnego wdrażania standardów UE  w całym sektorze.
EN
The paper is devoted to numerical analysis of the roof truss subjected to upward wind loading and braced at the tensioned top chord. Linear buckling analysis was performed for the beam and shell model of the structure. As a result, the influence of rotational connection stiffness between the brace and the top chord on truss stability was noted. A bi-axial strength testing machine was used to conduct the experimental tests of the rotational connection stiffness between selected steel profiles. The results in the form of measured structural displacements and rotations were presented. The static nonlinear analysis results obtained for the shell model of the structural connection were compared to the results obtained on the experimental set-up.
PL
W artykule przedstawiono możliwości, jakie daje technika PMU w aspekcie ewolucji w energetyce związanych z redukcją emisji CO2 oraz szerokim wprowadzaniem odnawialnych źródeł energii. Powyższe zmiany skutkują występowaniem zjawisk w systemie elektroenergetycznym, którymi trzeba będzie zarządzać. Korzystny jest fakt, że przed nami, z podobnymi problemami zderzyły się już służby energetyczne w wielu innych krajach, próbując wdrażać nowe techniki i aplikacje, aby sobie lepiej w nowej sytuacji radzić. Dlatego należy im się przyglądać i wdrażać szybko elementy wykorzystujące te techniki, najpierw na poziomie stacji elektroenergetycznej (instalacja źródeł PMU, serwerów PDC oraz infrastruktury komunikacyjnej), a potem budować aplikacje WAMS/WASC korzystające z tych informacji, tak aby rzeczywistość nas jutro nie zaskoczyła.
EN
The article presents the possibilities offered by the PMU technique in the aspect of the evolution in the energy sector related to the reduction of CO2 emissions and the wide using of renewable energy sources. The above changes result in the occurrence of phenomena in the electrical power system, which will have to be managed. It’s good situation that before changes in Poland, energy services in many other countries have already faced similar problems, trying to implement new techniques and applications to cope better in the new situation. Therefore, they should be watched and elements using these techniques should be implemented quickly. First at substation level (installation of PMU units, PDC servers and communication infrastructure) and then build WAMS/WASC applications using this information, so that reality does not surprise us tomorrow.
EN
The increasing complexity and scope of military computer networks necessitate robust methods to ensure network stability and security. This study presents a comprehensive analysis of computer network statistics in military local networks to develop a method for detecting information flows that disrupt stability. By leveraging advanced statistical techniques and machine learning algorithms, this research aims to enhance the cybersecurity posture of military local networks globally. Military networks are vital for communication, data exchange, and operational coordination. However, the dynamic nature of network traffic and the persistent threat of cyberattacks pose significant challenges to maintaining network stability. Traditional monitoring techniques often fail to meet the unique requirements of military networks, which demand high levels of security and rapid response capabilities. This study employs a multi-faceted approach to detect anomalies in network traffic, utilizing statistical methods such as Z-score analysis, Principal Component Analysis (PCA), and Autoregressive Integrated Moving Average (ARIMA) models. Machine learning techniques, including SupportVector Machines (SVM), Random Forests, Neural Networks, K-means clustering, and Reinforcement Learning, are also applied to identify patterns indicative of stability-disrupting information flows. The integration of statistical and machine learning methods forms a hybrid model that enhances anomaly detection, providing a robust framework for network security. The research problem is formulated as follows: does data collection include comprehensive network traffic data from various segments of military local area networks, including packet flows, transmission rates, and error rates over a specified period? Statistical analysis identifies patterns in the network traffic, which are then used to train machine learning models to classify normal and abnormal traffic. The research hypothesis states that machine learning models achieve high accuracy in detecting stability-disrupting information flows, with a precision rate exceeding 90%. The models identified several instances of stability-disrupting events, correlating these with known security incidents to validate the effectiveness of the detection method. This study underscores the importance of continuous monitoring and analysis of network statistics to ensure stability and security. The proposed method can be integrated with existing network monitoring and intrusion detection systems, providing a comprehensive approach to network security. Future research can build on these findings to develop more sophisticated models and explore additional factors influencing network stability, including the incorporation of advanced machine learning techniques, such as deep learning, and the exploration of other network metrics, like latency and packet loss. This comprehensive approach aims to enhance the security and operational reliability of military local networks.
PL
Rosnąca złożoność i zakres wojskowych sieci komputerowych wymagają solidnych metod zapewniających stabilność i bezpieczeństwo sieci. Celem niniejszej pracy jest przedstawienie kompleksowej analizy statystyk sieci komputerowych w lokalnych sieciach wojskowych w celu opracowania metody wykrywania przepływów informacji, które zakłócają stabilność. Wykorzystując zaawansowane techniki statystyczne i algorytmy uczenia maszynowego, niniejsze badanie ma na celu poprawę postawy cyberbezpieczeństwa lokalnych sieci wojskowych na całym świecie. Sieci wojskowe są niezbędne do komunikacji, wymiany danych i koordynacji operacyjnej. Jednak dynamiczna natura ruchu sieciowego i ciągłe zagrożenie cyberatakami stanowią poważne wyzwanie dla utrzymania stabilności sieci. Tradycyjne techniki monitorowania często nie spełniają unikalnych wymagań sieci wojskowych, które wymagają wysokiego poziomu bezpieczeństwa i możliwości szybkiego reagowania. W niniejszym badaniu zastosowano wieloaspektowe podejście do wykrywania anomalii w ruchu sieciowym, wykorzystując metody statystyczne, takie jak analiza Z-score, analiza głównych składowych (PCA) i modele autoregresyjnej zintegrowanej średniej ruchomej (ARIMA). Techniki uczenia maszynowego, w tym maszyny wektorów nośnych (SVM), lasy losowe, sieci neuronowe, klasteryzacja K-means i uczenie wzmacniające, są również stosowane w celu identyfikacji wzorców wskazujących na przepływy informacji zakłócające stabilność. Integracja metod statystycznych i uczenia maszynowego tworzy hybrydowy model, który wzmacnia wykrywanie anomalii, zapewniając solidne ramy dla bezpieczeństwa sieci. Problem badawczy sformułowano w następujący sposób: czy zbieranie danych obejmuje kompleksowe dane o ruchu sieciowym z różnych segmentów wojskowych sieci lokalnych, w tym przepływy pakietów, szybkości transmisji i wskaźniki błędów w określonym okresie? Analiza statystyczna identyfikuje wzorce w ruchu sieciowym, które są następnie wykorzystywane do trenowania modeli uczenia maszynowego w celu klasyfikowania normalnego i nieprawidłowego ruchu. Hipoteza badawcza stwierdza, że modele uczenia maszynowego osiągają wysoką dokładność w wykrywaniu przepływów informacji zakłócających stabilność, ze współczynnikiem precyzji przekraczającym 90%. Modele zidentyfikowały kilka przypadków zdarzeń zakłócających stabilność, korelując je ze znanymi incydentami bezpieczeństwa w celu sprawdzenia skuteczności metody wykrywania. Niniejsze badanie podkreśla znaczenie ciągłego monitorowania i analizy statystyk sieci w celu zapewnienia stabilności i bezpieczeństwa. Proponowaną metodę można zintegrować z istniejącymi systemami monitorowania sieci i wykrywania włamań, zapewniając kompleksowe podejście do bezpieczeństwa sieci. Przyszłe badania mogą opierać się na tych ustaleniach, aby opracować bardziej wyrafinowane modele i zbadać dodatkowe czynniki wpływające na stabilność sieci, w tym włączenie zaawansowanych technik uczenia maszynowego, takich jak głębokie uczenie, oraz eksplorację innych metryk sieciowych, takich jak opóźnienie i utrata pakietów. To kompleksowe podejście ma na celu zwiększenie bezpieczeństwa i niezawodności operacyjnej wojskowych sieci lokalnych.
EN
This paper proposes an optimal placement of FACTS to enhance smart grid performance. Indeed, this work analyzes the static and dynamic stability of voltage, angle, power and frequency of smart grid by testing some cases to explore the weakest regions. Currently, power grids, long power lines and rapidly increasing load demand make the system more demanding than ever. Random placement of FACTS cannot improve power grid performance. By studying unstable voltage regions using the line stability index method when placing FACTS methods predicts and prevents system failures. For this reason, a static and synchronous capacitors and Thyristor Controlled Series Compensator (TCSC) are used for effective voltage recovery and regulation. This device will be integrated in IEEE-14 bus. As results, the system can be managed efficiently and provide electricity to consumers in a reliable, safe and cost-effective manner. The PSAT SIMULINK environment is also used for performance analysis.
PL
W artykule zaproponowano optymalne rozmieszczenie FACTS w celu zwiększenia wydajności inteligentnych sieci. Rzeczywiście, w tej pracy analizowano statyczną i dynamiczną stabilność napięcia, kąta, mocy i częstotliwości inteligentnej sieci, testując niektóre przypadki w celu zbadania najsłabszych regionów. Obecnie sieci energetyczne, długie linie energetyczne i szybko rosnące zapotrzebowanie na obciążenie sprawiają, że system jest bardziej wymagający niż kiedykolwiek. Losowe rozmieszczenie FACTS nie może poprawić wydajności sieci energetycznej. Badając niestabilne obszary napięcia za pomocą metody wskaźnika stabilności linii podczas umieszczania metod FACTS, przewiduje się i zapobiega awariom systemu. Z tego powodu do skutecznego odzyskiwania i regulacji napięcia stosowane są kondensatory statyczne i synchroniczne oraz kompensator szeregowy sterowany tyrystorowo (TCSC). Urządzenie to będzie zintegrowane z magistralą IEEE-14. Dzięki temu można efektywnie zarządzać systemem i dostarczać energię elektryczną odbiorcom w sposób niezawodny, bezpieczny i opłacalny. Do analizy wydajności wykorzystywane jest także środowisko PSAT SIMULINK.
EN
The herein-described work aims to study and analyze the impact of harmonics on the transient stability of electrical networks. To do this, we measured harmonics in an Algerian industrial installation for different load power values namely (P = 2MW, P = 4MW, P = 6 MW and P = 10 MW). Using harmonic measurements obtained through this industrial facility, a harmonic model was created using MATLAB/SIMULINK software. Subsequently, this model was introduced in a standard IEEE 9 bus electrical network model to carry out study and analysis simulations of the transient stability of this network system with fault ( line opening fault) to observe the impact of these harmonics on the transient stability of the being studied network. The contribution in this work is the creation of a harmonic model under MATLAB/SIMULINK. Through harmonic measurement tests in an industrial electrical installation for different load power values, this created model can be used with any electrical network to study the effect of harmonics on the object to be studied.
PL
Opisana praca ma na celu badanie i analizę wpływu harmonicznych na stan przejściowy sieci elektrycznych. W tym celu zmierzyliśmy harmoniczne w algierskiej instalacji przemysłowej dla różnych wartości mocy obciążenia, mianowicie (P = 2 MW, P = 4 MW, P = 6 MW i P = 10 MW). Wykorzystując pomiary harmoniczne uzyskane w tym zakładzie przemysłowym, stworzono model harmoniczny przy użyciu oprogramowania MATLAB/SIMULINK. Następnie model ten wprowadzono do standardowego modelu sieci elektrycznej magistrali IEEE 9 w celu przeprowadzenia symulacji badania i analizy przejściowej stabilności tego systemu sieciowego z uszkodzeniem (błąd otwarcia linii) w celu obserwacji wpływu tych harmonicznych na przejściową stabilność sieci badana sieć. Wkładem w tę pracę jest utworzenie modelu harmonicznego w środowisku MATLAB/SIMULINK. Dzięki testom pomiarów harmonicznych w przemysłowej instalacji elektrycznej dla różnych wartości mocy obciążenia, stworzony model można wykorzystać w dowolnej sieci elektrycznej w celu zbadania wpływu harmonicznych na badany obiekt.
PL
Artykuł przedstawia proces projektowania i wykonywania zaprawy cementowej o optymalnej urabialności, spełniającej regulaminowe kryteria konkursu „Mortar Workability 2024” organizowanego przez American Concrete Institute (ACI) w Nowym Orleanie w USA, dotyczące właściwości reologicznych, parametrów ekologicznych i ekonomicznych.
EN
The article presents the process of designing and manufacturing a concrete mortar with optimal workability, meeting the regulatory criteria of the „Mortar Workability 2024” competition, concerning rheological properties of cement-based mixtures. The event is organized by the American Concrete Institute (ACI) in New Orleans USA.
PL
W związku z dostrzeżonymi wadami dotychczas stosowanej metody analizy wpływu drzew na stabilność posadowienia obiektów budowlanych autorzy postanowili zmienić kilka szczegółów procedury. Postanowiono wykorzystać pomysł stosowany już od dawna w innych dziedzinach wiedzy – mapę warstwobarwną. W artykule zamieszczono praktyczne wskazówki, jak taką mapę wykonać i zinterpretować.
EN
Due to the noticed shortcomings of the previously used method of analyzing the impact of trees on the stability of the foundations of building structures, the authors decided to change several details of the procedure. It was decided to use an idea that has long been used in other fields of knowledge – a color layer map. The article contains practical tips on how to create and interpret such a map.
EN
Wheelchairs are the primary means of movement for people with mobility disabilities, regardless of their type of drive. One of the main features of wheelchairs, besides their ability to generate drive, maneuverability, and body support, is their stability of movement. This stability largely depends on the height of the center of gravity in the human-wheelchair system. This parameter is very important from the perspective of wheelchair user safety, especially when overcoming architectural obstacles such as curbs, stairs, or slopes. Currently, many models available on the market have additional protection in the form of support wheels, which prevent the wheelchair from tipping over backwards with the user. However, the use of these support wheels is associated with an increase in the weight and dimensions of the wheelchair, as well as a decrease in ergonomics. Faced with this problem, the authors have set out to present an innovative method for calculating the height of the center of gravity and conducted a series of experimental tests on various wheelchair designs. The research analyzed the displacement of the center of gravity depending on the angle of the inclination of the ground from 0⁰ to 15⁰. The conclusions obtained regarding stability and the calculation of the center of gravity in relation to maintaining balance can form the basis for designing new wheelchair structures.
EN
The study delves into characterizing the mechanical parameters of the Tahar Louchene aggregate quarry unit in Ain Touta municipality, Batna province, Algeria. This investigation is crucial to address recurring instabilities commonly encountered in open-cast mines. Our approach adopts a comprehensive methodology integrating geotechnical, geomechanical, and numerical analyses, aiming to provide a thorough assessment of fractured rock mass behavior. Our methodology begins with detailed geological surveys aimed at optimal drilling site selection. Geomechanical analysis follows, focusing on fracturing and evaluating rock mass quality, complemented by geotechnical investigations featuring in-situ testing. To gather representative samples, we extracted eighteen cylindrical cores (102 mm × 204 mm) from various benches using a mechanical coring drill. These cores underwent rigorous physical characterization, geochemical analysis, and mechanical testing. Furthermore, 3D FEM numerical modeling was applied to comprehensively assess rock edge stability. The outcomes of our study unveil the presence of four distinct discontinuity sets within the primary formations, with particular emphasis on fault families of geological significance influencing deposit configuration. These fault structures provide valuable insights into stress history and tectonic evolution that directly impact the stability of the quarry. Moreover, our analysis identified various failure types, notably exacerbated by blasting practices that reduce safety factor values, highlighting the critical need for improved safety protocols. Our approach not only contributes to enhancing mining efficiency and productivity but also prioritizes the safety of equipment and personnel in open-cast mining operations across Algeria.
PL
W artykule przedstawiono problem intensyfikującego wpływu procesu koagulacji na korozyjne właściwości wody, na przykładzie przeprowadzonych badań nad stabilnością chemiczną wody powierzchniowej po koagulacji wzrastającymi dawkami siarczanu glinu. Omówiono wyniki przeprowadzonych badań, metody zastosowane do oceny stabilności chemicznej analizowanej wody przy wykorzystaniu różnych indeksów stabilności oraz porównanie ich wskazań.
EN
The article presents the problem of the intensifying influence of the coagulation process on the corrosive properties of water, based on the example of conducted research on the chemical stability of surface water after coagulation with increasing doses of aluminum sulphate. The results of research, methods used to assess the chemical stability of the analyzed water with the use of various stability indices and the comparison of their indications are discussed.
EN
The research focuses on solving the important problem of slope stability in the field of civil engineering. The study adopted an advanced strength double reduction coefficient method for slope stability analysis, which considers the different influence weights of cohesion and internal friction angle, and reduces them with different reduction coefficients to describe the stability of the slope. The simulation experiment results indicate that the attenuation degree of cohesion and internal friction angle affects slope stability. When the reduction coefficient of cohesion increases to 1.737 and the reduction coefficient of internal friction angle increases to 1.201, the slope is prone to instability and failure, and the safety factor of the calculated result is 1.493. Moreover, when the anti-slip pile is set in the middle of the slope (1/2), and the slope is in a critical state, the bending moment and shear force suffered by the anti-slip pile are both maximum, so the reinforcement effect is also the best.
13
EN
Scaffolds are temporary structures that include anchors, elements, and platforms that are used during the construction of steel or concrete structures to support equipment or workers at height. Since these structures have aimed to guarantee safety and support workers at heights, the stability of scaffold systems is of significant importance. These systems have some disadvantages. For example, they are sensitive to vibrations. This feature reduces their stability under service-, cyclic-, or earthquake loadings. Furthermore, the vibrating nature of scaffolds can impose additional axial loads and consequently additional moment loads on the scaffold columns and decrease the safety of workers and increase the accidents of use of them. In this paper, a review of some research has been performed that aimed to solve this problem and improve the stability of scaffolds. These articles have investigated the behaviour of anchors and joints and the influence of imperfections and inaccuracies on scaffolds. A summary of research has been presented that has proposed new methods for predicting the behaviour, damage, and collapse of scaffolds using some structural health monitoring (SHM) methods. Finally, the research gaps and limitations of previous studies have been investigated, with a focus on monitoring and solving the problems of the scaffolds and critical elements so that these problems can be solved and evaluated in future studies.
PL
Rusztowania to konstrukcje tymczasowe. Składają się ze stojaków, prętów stężeń, podestów i zakotwienia. Najczęściej są one wykorzystywane na etapie budowy czy remontu konstrukcji budowlanych i służą do podtrzymywania sprzętu i pracowników na wysokości. Ponieważ konstrukcje te mają na celu zagwarantowanie bezpieczeństwa ludzi pracujących na wysokości to olbrzymie znaczenie ma ich stateczność. Rusztowania mają różne wady np. są wrażliwe na wibracje. Ta cecha zmniejsza ich stabilność pod działaniem obciążeń zmiennych, cyklicznych lub trzęsieniem ziemi. Co więcej, drgania rusztowań mogą powodować dodatkowe siły osiowe i momenty zginające w słupach rusztowania, zmniejszając bezpieczeństwo pracowników i zwiększając liczbę wypadków związanych z ich użytkowaniem. W niniejszym artykule dokonano przeglądu badań mających na celu rozwiązanie tego problemu i poprawę stabilności rusztowań. Analizowana w pracy literatura dotyczyła zachowania kotew i złączy oraz wpływu imperfekcji geometrycznych i niedokładności montażowych na bezpieczeństwo rusztowań. W artykule przedstawiono podsumowanie badań, w których zaproponowano nowe metody przewidywania zachowania, uszkodzeń i katastrof rusztowań przy użyciu metod monitorowania stanu konstrukcji (SHM). Wskazano luki badawcze i ograniczenia poprzednich badań. Skoncentrowano się na monitorowaniu i rozwiązywaniu problemów rusztowań i ich elementów krytycznych, tak aby mogły być one rozwiązywane i oceniane w przyszłych badaniach.
EN
In the work improved system of equation of plane-parallel movement of the road train with single-axle O1-category trailer. Defined lateral reactions on the vehicle and trailer wheels at body roll, wheels slip caused by body roll and also developed road train spatial mathematical model in a transverse plane. This model is used to study the road train course stability with O1-category trailer. It is shown that the spatial model of road train with no vehicle and trailer wheels inclination has the same divergent instability characteristic as the plane road train layout.
PL
W artykule omówiono zagadnienie wpływu OZE, którego udział w sieci elektroenergetycznej wzrasta i będzie dalej ulegał znacznemu wzrostowi w niedalekiej przyszłości. Będzie to powodowało nowe, niespotykane wcześniej w systemie elektroenergetycznym, problemy związane z szeroko rozumianą stabilnością systemu elektroenergetycznego. Zwrócono też uwagę na fakt, że rozwój energetyki rozproszonej wpływa na nowe zadania i uwarunkowania pracy układów EAZ, a operatorzy sieci przewidują decentralizację i automatyzację systemów regulacji napięcia i sankcjonowanie pracy wyspowej. Przydatnym narzędziem do analizy stanu stabilności w systemach może być pomiar PMU (Phasor Measurment Unit), coraz częściej dostępny w przekaźnikach zabezpieczeniowych jako dodatkowa funkcja. Zastosowanie synchrofazorów i techniki PMU w systemie elektroenergetycznym obejmuje już nie tylko szeroko omawianą ocenę stabilności, ale także może być przydatne w tworzeniu obszarowych - Wide Area - systemów zabezpieczeń WAP oraz systemów sterowania WACS. Oferenci, przygotowując się do zmian w systemie elektroenergetycznym, opracowują automatyki wspomagające utrzymanie stabilności w systemie. Przykładem może być firma GE, która wprowadziła na rynek produkt PowerNode, do którego nawiązano w niniejszym artykule.
EN
The article discusses the issue of the impact of Renewable Energy Sources on HV network, the share of which in the power grid is increasing and will continue to increase significantly in the near future. This will cause new problems, not previously encountered in the power system, related to the widely understood stability of the electricity system. Attention was also drawn to the fact that the development of distributed energy affects new tasks and conditions for the operation of Power Protection Automation systems, and network operators envisage decentralization and automation of voltage regulation systems and accepting of island operation of the Power System. A useful tool for analyzing the state of stability in systems may be PMU (Phasor Measurement Unit) measurement, which is more often available in protection relays as an additional function. The use of synchrophasors and PMU technology in the power system not only covers the widely discussed Power System stability assessment, but can also be useful in creating Wide Area WAP security systems and WACS control systems. In preparation for changes in the Power System, bidders are developing automation systems that help maintain stability in the system. An example is GE, which introduced the product PowerNode, which is referred to in this publication.
EN
Asphalt concrete from old pavements may be reused as a semi-product in production of new bituminous mixtures or recycled in place using the cold-in-place recycling method. The first of the two above-mentioned recycling methods is appropriate when dealing with uniform materials, coming from bituminous pavements whose parameters are either known or can be reliably determined. The second method comes into play when dealing with old pavements in which the mixes used for the respective layers included different bituminous binders, typical of local roads in Poland. Smaller size jobs are an example of works for which cold-in-place recycling methods are not practicable. Fortunately, there is an option of using the old asphalt or reclaimed asphalt pavement (RAP) as aggregate in production of cement-bound mixtures. This paper describes the study on determination of their properties. These properties included density, compressive strength at different temperatures, split tensile strength and Marshall stability. The results of the relevant tests, which were carried out as part of this study, showed suitability of RAP as aggregate used for production of cement stabilised base mixtures.
PL
Destrukt asfaltowy może stanowić półprodukt w nowych mieszankach mineralno-asfaltowych jak i być wykorzystywany do mieszanek w technologii recyklingu na zimno. Pierwsza technologia jest właściwa w sytuacji kiedy destruktu jest jednorodny i pochodzi z nawierzchni o znanych lub możliwych do ustalenia parametrach. Druga technologia może być wykorzystana do przetwarzania starych nawierzchni asfaltowych, o zmiennych parametrach (różne warstwy z różnym lepiszczem), które nadal dominują na drogach lokalnych. Technologie na zimno z różnych względów nie zawsze mogą być zastosowane, np. w sytuacji, której przewidywany zakres prac jest niewielki. Alternatywą może być wykorzystania destruktu asfaltowego jako kruszywo do wykonania mieszanek stabilizowanych spoiwem. Autorzy przeprowadzili program badawczy, który miał na celu określenie parametrów mieszanek stabilizowanych spoiwem cementowym z wykorzystaniem destruktu. W badaniach określono takie cechy jak: gęstość, wytrzymałość na ściskanie w różnych temperaturach, wytrzymałość na rozciąganie przy rozłupywaniu, badanie stabilności wg Marshalla. Na podstawie przeprowadzonych badań, ustalono, że destrukt asfaltowy może zostać z powodzeniem wykorzystany jako kruszywo do produkcji mieszanki związanej spoiwem cementowym.
EN
In this research paper, we intend to study the issue of improving the stability robustness and accuracy performance of double Proportional-Integral and reduced order state estimator based speed controlled DC drive system when subjected to sudden change of load torque disturbance, where an optimized transfer function based feedforward compensating technique is proposed and applied for this purpose. The simulation results have shown a significant improvement of systems’ accuracy performance and stability robustness to variable load torque.
PL
W tym artykule badawczym zamierzamy zbadać kwestię poprawy stabilności, wytrzymałości i dokładności systemów napędowych DC sterowanych prędkością w oparciu o podwójną proporcjonalność-całkę i estymator stanu zredukowanego, gdy są poddawane nagłej zmianie zakłócenia momentu obrotowego obciążenia, gdzie zoptymalizowana funkcja przenoszenia W tym celu zaproponowano i zastosowano technikę kompensacji opartą na wyprzedzaniu. Wyniki symulacji wykazały znaczną poprawę dokładności i odporności systemów na zmienny moment obciążenia.
EN
This paper describes how fuzzy based STATCOM was used to improve the small signal stability of Tis Abay II electric power generation. Tis Abay II is a power generation facility in Ethiopia, located in the Bahir Dar Amhara region, with a nominal apparent power generating capacity of 40MVA. The oscillating nature of a rotating machine, the imbalance of load and generation, the presence of exciter and compensator, and the occurrence of faults all contribute to the disruption on an interconnected power network. The frequency oscillation of the existing plant was evaluated in the absence of a power system stabilizer (PSS) and an adaptive fuzzy logic controller (AFLC). The proposed system network configuration was used to fine-tune the mathematical analysis of synchronous machine data and model. The proposed model incorporates SMIB system modeling and an AFLC. MATLAB Simulink was used to simulate the effect of the PSS and AFLC on rotor speed, angle, and electrical torque. The proposed system's power system dynamic stability was improved using a PSS and a fuzzy logic-based STATCOM. According to the simulation results, FLCbased STATCOM is best suited for improving the dynamic stability of Tis Abay II power generation.
PL
W tym artykule opisano, w jaki sposób STATCOM oparty na rozmyciu został wykorzystany do poprawy stabilności małych sygnałów w wytwarzaniu energii elektrycznej Tis Abay II. Tis Abay II to zakład energetyczny w Etiopii, położony w regionie Bahir Dar Amhara, o nominalnej mocy pozornej wytwarzania 40MVA. Oscylacyjny charakter maszyny wirującej, niezrównoważenie obciążenia i generacji, obecność wzbudnicy i kompensatora oraz występowanie usterek przyczyniają się do zakłóceń w połączonej sieci energetycznej. Oscylacje częstotliwości istniejącej elektrowni zostały ocenione przy braku stabilizatora systemu elektroenergetycznego (PSS) i adaptacyjnego sterownika logiki rozmytej (AFLC). Zaproponowana konfiguracja sieci systemu została wykorzystana do dostrojenia analizy matematycznej danych i modelu maszyny synchronicznej. Proponowany model obejmuje modelowanie systemu SMIB i AFLC. MATLAB Simulink wykorzystano do symulacji wpływu PSS i AFLC na prędkość wirnika, kąt i moment elektryczny. Stabilność dynamiczna systemu elektroenergetycznego proponowanego systemu została poprawiona za pomocą PSS i STATCOM opartego na logice rozmytej. Zgodnie z wynikami symulacji, STATCOM oparty na FLC najlepiej nadaje się do poprawy dynamicznej stabilności generacji Tis Abay II.
PL
W pracy za pomocą zmian przewodności zbadano zmiany konformacyjne proteiny BSA oraz jej kompleksów (BSA-Au oraz BSA-NAA) pod wpływem promieniowania UV oraz MF aplikowanego frakcyjnie w dawkach (3 × 10 min oraz 6 × 10 min) oraz w sposób ciągły (30 min, 60 min). Wykonano analizę porównawczą wpływu promieniowania UV i mikrofalowego w dawkach ciągłych i frakcyjnych na BSA, BSA-Au, BSA-NAA oraz przeanalizowano czułość na pole elektromagnetyczne z zakresu UV i MF dla badanych substancji. Udowodniono efekt przyspieszonych zmian konformacyjnych pod wpływem pola elektromagnetycznego z zakresu UV i MF. Wykazano wpływ czynników na stabilność BSA i jej kompleksów zależny od: rodzaju czynnika, sposobu jego aplikacji oraz czasu ekspozycji. Najbardziej czuły na pole elektromagnetyczne okazał się kompleks BSA-Au.
EN
In this study, the conformational changes of BSA protein and its complexes (BSA-Au and BSA-NAA) under UV and MF radiation applied in fractional doses (3 × 10 min and 6 × 10 min) and continuously (30 min, 60 min) were investigated by means of conductivity changes. A comparative analysis of the effect of UV and microwave radiation in continuous and fractional doses on BSA, BSA-Au, BSA-NAA was performed, and the sensitivity to UV and MF electromagnetic fields of the tested substances was analysed. The effect of accelerated conformational changes under the influence of UV and MF electromagnetic field was proved. The influence of the factors on the stability of BSA and its complexes was shown to depend on: the type of agent, the method of its application and the exposure time. The most sensitive to the electromagnetic field turned out to be the complex BSA-Au.
EN
This paper aims to determine the effect of global economic policy uncertainty on the banking system's stability in Asian countries. The dependent variable in the study is measured through the bank's payment risk Zscore. The primary explanatory factor is global economic policy uncertainty, and other control variables include the banking system's characteristics and the national economic environment. Asian banking systems’ data are collected from World Bank between 2008 and 2020. Based on the System Generalized Method of Moments, the main results indicate that global economic policy uncertainty is seriously exacerbating the instability of the banking system of Asian countries. The study also shows that the ability to use mobilized capital and the degree of concentration of the system reduces the adverse impact of global economic policy uncertainty on the stability of the banking system in Asian countries.
PL
Celem niniejszego artykułu jest określenie wpływu niepewności globalnej polityki gospodarczej na stabilność systemu bankowego w krajach azjatyckich. Zmienna zależna w badaniu jest mierzona za pomocą wskaźnika Zscore ryzyka płatniczego banku. Głównym czynnikiem objaśniającym jest niepewność globalnej polityki gospodarczej, a inne zmienne kontrolne obejmują charakterystykę systemu bankowego i krajowe środowisko gospodarcze. Dane dotyczące azjatyckich systemów bankowych pochodzą z Banku Światowego w latach 2008-2020. W oparciu o system uogólnionej metody momentów, główne wyniki wskazują, że niepewność globalnej polityki gospodarczej poważnie pogarsza niestabilność systemu bankowego krajów azjatyckich. Badanie pokazuje również, że zdolność do wykorzystania zmobilizowanego kapitału i stopień koncentracji systemu zmniejsza niekorzystny wpływ niepewności globalnej polityki gospodarczej na stabilność systemu bankowego w krajach azjatyckich.
first rewind previous Strona / 25 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.