This article presents the impact of accuracy of sensors, or more specifically Pt100 temperature sensors, on result analysis of experimental studies. For this purpose, an experiment was carried out consisting in measuring the temperature on the surface of a partition - a concrete wall, beneath its insulation layer. The tested surface was separated from external environment and could only be influenced by the wall structure. Therefore, the expected result of the experiment, i.e. the difference in temperature sensor readings in identical locations on both sides of the partition, should reach a value close to 0. This article also presents the values of absolute error for sensors which were determined before their installation on the surface, and on which their location depended. The obtained deviations were included in the results of the experiment, which led to a decrease in temperature differences on both sides of the partition, in some cases even reaching the expected value of 0. This analysis showed how important it is to know the measurement error and then eliminate it in result interpretation.
2
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The article presents the influence of environmental conditions on the temperature distribution in a pipe-embedded wall. For this purpose, measurements were taken on a test stand, a concrete wall with thermoplastic pipes (with a thermally activated element) embedded inside it in its symmetry axis. The wall is insulated with polystyrene on both sides. Additionally, as a result of its closure in an insulated casing made of oriented strand board (OSB), 2 air zones were created on both sides of the wall. The concreted loop was connected to a cooling bath thermostat used to set the supply temperature in the pipes. In the case of air, its supply to the air zones was provided by ventilation ducts mounted to the housing. The tests consisted of two stages: stabilization of the temperature on the surface of the partition between the concrete and polystyrene layer and the reaction of the structure to a variable outside temperature when fresh outside air was supplied to one of the air zones. All measurements were performed for the following settings: 16°C, 18°C, 20°C and 22°C. It was noted that in order to achieve an even temperature on the wall surface, 24 hours were required from the moment the cooling bath thermostat was turned on. When outside air is supplied to one of the air zones, this partition is resistant to temperature fluctuations, and only after about 6 hours a temperature change of 0.1°C takes place for sensors located at the extreme measurement points and in the other air zone (without air inflow).
PL
W artykule przedstawiono wpływ warunków otoczenia na rozkład temperatury w ścianie z wbudowanymi przewodami. W tym celu wykonano pomiary na stanowisku badawczym, betonowej ścianie z przewodami tworzywowymi (z elementem aktywowanym termicznie) wbudowanymi wewnątrz niej w jej osi symetrii. Ściana ta została z obu stron zaizolowana styropianem. Dodatkowo w wyniku zamknięcia jej w zaizolowanej obudowie wykonanej z płyt OSB powstały dwie strefy powietrzne z obu stron ściany. Zabetonowana pętla została podłączona do ultratermostatu, służącego do nastawienia temperatury zasilania w przewodach. W przypadku powietrza jego dostarczenie do stref powietrznych zapewniały zamontowane do obudowy przewody wentylacyjne. Badania składały się z dwóch etapów: stabilizacji temperatury na powierzchni przegrody między warstwą betonu a styropianu oraz reakcji konstrukcji na zmienną temperaturę zewnętrzną podczas dostarczania do jednej ze stref powietrznych świeżego powietrza zewnętrznego. Wszystkie pomiary odbywały się dla nastaw: 16°C, 18°C, 20°C i 22°C. Zauważono, że w celu osiągnięcia wyrównanej temperatury na powierzchni ściany potrzeba 24 godzin od momentu włączenia ultratermostatu. W przypadku dostarczania powietrza zewnętrznego do jednej ze stref powietrznych, przegroda ta jest odporna na wahania temperatury i dopiero po około 6 godzinach następuje zmiana temperatury o 0,1°C dla czujników zlokalizowanych w skrajnych punktach pomiarowych oraz w drugiej strefie powietrznej (bez napływu powietrza).
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.