The existing legal status [4] requires that the construction design of a building must include an analysis of the possibilities of rational use of renewable energy and heat sources. It is interesting that neither the Construction Law [5] nor the regulation on the technical conditions to be met by buildings [3] contain sentences strictly defining this obligation. And the legal obligation to use renewable heat and energy sources should not apply to the author of the construction design, but to the investor of the building, as the entity deciding on the conditions of future operation of the heating system. This article discusses only the technical issues of cooperation between a heating substation supplied by a centralized heating system and a heat pump, leaving legislative issues to lawyers and economic issues to the authors of analyzes and feasibility studies.
2
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Artykuł jest kontynuacją zamieszczonego w numerze 6/2024 artykułu „Efektywność przygotowania ciepłej wody w węźle cieplnym współpracującym z instalacją kolektorów słonecznych”, w którym podano m.in. ogólne warunki prawidłowego funkcjonowania słonecznych systemów przygotowania ciepłej wody współpracujących z węzłami cieplnymi. Niniejszy artykuł zawiera omówienie schematów ideowych instalacji słonecznych mogących prawidłowo współpracować z węzłem cieplnym zasilanym z miejskiej sieci ciepłowniczej. Zwrócono w nim także uwagę na nieprawidłowości w oferowanych na rynku schematach instalacji słonecznych, mogące znacznie obniżyć efektywność działania układów przygotowania ciepłej wody.
EN
The article is a continuation of the article “Efficiency of domestic hot water production in a district heating substation cooperating with the solar collector installation” published in issue 6/2024, which includes, among others, general conditions for the proper functioning of solar hot water production systems cooperating with district heating substations. This article discusses the schematic diagrams of solar installations that can properly cooperate with a district heating substation powered from the municipal heating network. It also draws attention to inaccuracies in the solar installation diagrams offered on the market, which may significantly reduce the efficiency of hot water preparation systems.
3
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W artykule przedstawiono problematykę efektywności technicznej i ekonomicznej przygotowania ciepłej wody w węźle cieplnym współpracującym z instalacją kolektorów słonecznych. W przykładowym budynku mieszkalnym, na podstawie danych meteorologicznych roku porównawczego, obliczono roczny stopień pokrycia zapotrzebowania na ciepłą wodę oraz wyznaczono współczynnik efektywności technicznej i ekonomicznej systemu w czasie jednego roku. Wyznaczono prosty czas zwrotu przykładowej inwestycji polegającej na dołączeniu do węzła cieplnego baterii kolektorów słonecznych.
EN
The article describes the issues of technical and economic efficiency of hot domestic water production in a district heating substation cooperating with a solar panel installation. In an example residential building, based on meteorological data from the reference year, the annual degree of coverage of hot water demand was calculated, and the efficiency and economic coefficient of the system were determined during one year. A simple payback period for an example investment consisting of connecting a solar collector battery to a heating substation was determined.
4
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W artykule przedstawiono specyfikę projektowania węzłów cieplnych współpracujących z układem podgrzewania powietrza w systemach klimatyzacji bloków operacyjnych szpitala. Zwrócono uwagę na następujące specyficzne problemy: dobór wymienników ciepła stosownie do bilansu mocy cieplnej w kontekście zastosowania wymienników do odzyskiwania ciepła o wysokiej sprawności w systemie wentylacji i klimatyzacji, dobór elementów węzła cieplnego uwzględniający istotne i szybkie zmiany zapotrzebowania na moc cieplną, zabezpieczenie instalacji podgrzewania powietrza i węzła cieplnego przed skokową zmianą parametrów operacyjnych, dobór właściwego schematu zasilania nagrzewnic i elementów automatycznej regulacji z punktu widzenia zapewnienia precyzji parametrów i z punktu widzenia właściwego funkcjonowania węzła cieplnego, zabezpieczenie instalacji podgrzewania powietrza przed wpływem niskiej temperatury otoczenia. Podano warunki, jakie powinien spełniać nie tylko węzeł cieplny, ale również instalacja podgrzewania powietrza wentylacyjnego.
EN
The article presents the specificity of designing district heating substation (DHS) cooperating with the air heating system in the air conditioning systems of hospital operating blocks. The following specific problems are highlighted: selection of heat exchangers according to the heat power balance in the context of the use of heat exchangers with high-efficiency heat recovery in ventialion and air conditioning systems, selection of the elements of the DHS, taking into account significant and rapid changes in heat power demand, protection of the air heating installation and the DHS against jumps of operating parameters, selection of the correct power supply scheme for heaters and control elements from the point of view of the precision of air parameters and from the point of view of the proper functioning of the DHS, protection of the air heating installation against the influence of low ambient temperature. The conditions that should be met not only by the heat substation, but also by the air conditioning installation are given.
5
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Przepisy prawne obowiązujące w Polsce [4,7] wymagają projektowania budynków i ich infrastruktury z zachowaniem zasad oszczędności energii i racjonalności przyjętych rozwiązań. Zapotrzebowanie na moc cieplną do ogrzewania budynków spełniających wysoki standard ochrony cieplnej jest znacznie mniejsze niż zapotrzebowanie na moc cieplną do przygotowania ciepłej wody, nawet jeśli jako miarodajne do doboru wymiennika ciepła przyjąć warunki 20 minutowego zapotrzebowania [1,5]. W artykule przedstawiono wyniki symulacji stanów eksploatacyjnych wymiennikowego węzła cieplnego w budynku mieszkalnym o 18 mieszkaniach w 3 wybranych warunkach klimatycznych sezonu grzewczego. Wykazano, że węzeł w budynku o wysokim standardzie ochrony cieplnej charakteryzuje się dużą dobową zmiennością strumienia masy nośnika ciepła i niewielką zmiennością maksymalnego dobowego strumienia masy w przekroju rocznym.
EN
Law regulations in Poland [4,7] require the design of buildings and their infrastructure with energy saving principles and rationality. Energy consumption (heat load) for heating buildings that meet the high standard of thermal protection is much lower than the demand of heat flux for preparing hot water, even if the conditions of the 20-minute demand [1,5] are used as a reliable condition for the selection of the heat exchanger. The article presents the results of simulation of the operating conditions of a heat exchanger substation in a residential building with 18 apartments at 3 selected climatic conditions of the heating season. It has been shown that a DHS in a building with a high standard of thermal protection is characterized by a high daily variability of mass flow in a district heating network. There is a small variability of the maximum daily mass flow in a year.
6
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W artykule, o nieco przewrotnym tytule, opisano wyzwania stojące przed polskimi systemami ciepłowniczymi spowodowane koniecznością ich transformacji i modernizacji po to, aby osiągnąć główny i wyjątkowo ambitny cel unijnej polityki klimatycznej, tj. neutralność klimatyczną do r. 2050. Jest to również główne i wymuszone, lecz ogromnie kosztowne, zadanie stojące przed polskim ciepłownictwem/ogrzewnictwem. Przedsięwzięcie to jest wyjątkowo trudne ze względu na to, że podstawowym paliwem w polskich systemach ciepłowniczych jest węgiel kamienny, a ponadto systemy te są największe w UE. Plany transformacji systemów energetycznych sformułowane są w globalnych, regionalnych (UE) oraz krajowych projektach, przy czym wspólnym mianownikiem tych projektów jest minimalizacja zużycia paliw kopalnych i zastąpienie ich ciepłem oraz energią z zasobów OZE, poprawa efektywności wytwarzania, przesyłania i wykorzystania ciepła oraz energii, a także integracja systemów energetycznych, cieplnych i chłodniczych, w system multienergetyczny. To ostatnie przedsięwzięcie wymusza konieczność elektryfikacji gospodarki, a w tym także ciepłownictwa/ogrzewnictwa. Elektryfikacja ciepłownictwa/ogrzewnictwa związana jest z kolei koniecznością większego rozpowszechnienia w tej dziedzinie technologii pomp ciepła, które pozwalają na wyjątkowo efektywne i racjonalne wykorzystanie energii elektrycznej. Jednak, ze względu na to, że podaż energii pochodzącej ze źródeł wykorzystujących OZE jest nieprzewidywalna i niekoherentna w stosunku do potrzeb, a ponadto roczny stopień wykorzystania mocy zainstalowanej stosunkowo niewielki: elektrownie wiatrowe ‒ 22%, a fotowoltaiczne ‒ 10%, to źródła te muszą być wspomagane przez urządzenia konwencjonalne (reaktory jądrowe, urządzenia do termicznej utylizacji odpadów komunalnych, kotły opalane lokalną biomasę, biogazem itd.). Ponadto w systemach tych powinny być stosowane zasobniki ciepła i energii, a ich racjonalna eksploatacja wymaga wprowadzenia specjalnych rozwiązań umożliwiających inteligentne zarządzanie podażą energii oraz popytem na nią. Zagadnienia te są tematem artykułu, przy czym w ich analizie uwzględniono specyficzne uwarunkowania krajowe.
EN
The article, with a slightly perverse title, describes the challenges faced by the Polish district heating systems due to the necessity of their transformation and modernisation to achieve the main and extremely ambitious objective of the EU climate policy, i.e., climate neutrality by 2050. This is also the main and forced, but extremely costly task facing the Polish district heating/heating sector. This undertaking is extremely difficult because the basic fuel in Polish district heating systems is hard coal and since these systems are the largest in the EU. The plans for the transformation of energy systems are formulated in global, regional (EU), and national projects, the common denominator of which is to minimise the consumption of fossil fuels and replace them with heat and energy from RES resources, to improve the efficiency of heat and energy production, transmission, and use as well as to integrate energy systems, heating, and cooling, into a multi- energy system. The latter requires the electrification of the economy, including the heating sector. Electrification of the heating sector, in turn, is associated with the need for greater dissemination in this field of heat pump technology, which allows for extremely efficient and rational use of electricity. However, since the supply of energy from RES sources is unpredictable and incoherent to needs and, the annual utilisation rate of installed capacity is relatively low: wind power plants – 22% and photovoltaic – 10%, these sources must be supported by conventional equipment (nuclear reactors, municipal waste thermal treatment plants, boilers fired by local biomass, biogas, etc.). Moreover, heat and energy storage tanks should be used in these systems, and their rational operation requires the introduction of special solutions enabling intelligent energy supply and demand management. These issues are the subject of the article, while their analysis considers the specific national conditions.
7
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W artykule, o nieco przewrotnym tytule, opisano wyzwania stojące przed polskimi systemami ciepłowniczymi spowodowane koniecznością ich transformacji i modernizacji po to, aby osiągnąć główny i wyjątkowo ambitny cel unijnej polityki klimatycznej, tj. neutralność klimatyczną do r. 2050. Jest to główne i wymuszone, lecz ogromnie kosztowne, zadanie stojące przed polskim ciepłownictwem/ogrzewnictwem. Przedsięwzięcie to jest wyjątkowo trudne ze względu na to, że podstawowym paliwem w polskich systemach ciepłowniczych jest węgiel kamienny, a ponadto systemy te są największe w UE. Plany transformacji systemów energetycznych sformułowane są w globalnych, regionalnych (UE) oraz krajowych projektach, przy czym wspólnym mianownikiem tych projektów jest minimalizacja zużycia paliw kopalnych i zastąpienie ich ciepłem oraz energią z zasobów OZE, poprawa efektywności wytwarzania, przesyłania i wykorzystania ciepła oraz energii, a także integracja systemów energetycznych, cieplnych i chłodniczych, w system multienergetyczny. To ostatnie przedsięwzięcie wymusza konieczność elektryfikacji gospodarki, a w tym także ciepłownictwa/ogrzewnictwa. Elektryfikacja ciepłownictwa/ogrzewnictwa związana jest z kolei koniecznością większego rozpowszechnienia w tej dziedzinie technologii pomp ciepła, które pozwalają na wyjątkowo efektywne i racjonalne wykorzystanie energii elektrycznej. Jednak, ze względu na to, że podaż energii pochodzącej ze źródeł wykorzystujących OZE jest nieprzewidywalna i niekoherentna w stosunku do potrzeb, a ponadto roczny stopień wykorzystania mocy zainstalowanej jest stosunkowo niewielki: elektrownie wiatrowe ‒ 22%, a fotowoltaiczne ‒ 10%, to źródła te muszą być wspomagane przez urządzenia konwencjonalne (reaktory jądrowe, urządzenia do termicznej utylizacji odpadów komunalnych, kotły opalane lokalną biomasę, biogazem itd.). Ponadto w systemach tych powinny być stosowane zasobniki ciepła i energii, a ich racjonalna eksploatacja wymaga wprowadzenia specjalnych rozwiązań umożliwiających inteligentne zarządzanie podażą energii oraz popytem na nią. Zagadnienia te są tematem artykułu, przy czym w ich analizie uwzględniono specyficzne uwarunkowania krajowe.
EN
The article, with a slightly perverse title, describes the challenges faced by the Polish district heating systems due to the necessity of their transformation and modernisation to achieve the main and extremely ambitious objective of the EU climate policy, i.e., climate neutrality by 2050. This is also the main and forced, but extremely costly task facing the Polish district heating/heating sector. This undertaking is extremely difficult because the basic fuel in Polish district heating systems is hard coal and since these systems are the largest in the EU. The plans for the transformation of energy systems are formulated in global, regional (EU), and national projects, the common denominator of which is to minimise the consumption of fossil fuels and replace them with heat and energy from RES resources, to improve the efficiency of heat and energy production, transmission, and use as well as to integrate energy systems, heating, and cooling, into a multi- energy system. The latter requires the electrification of the economy, including the heating sector. Electrification of the heating sector, in turn, is associated with the need for greater dissemination in this field of heat pump technology, which allows for extremely efficient and rational use of electricity. However, since the supply of energy from RES sources is unpredictable and incoherent to needs and, the annual utilisation rate of installed capacity is relatively low: wind power plants – 22% and photovoltaic – 10%, these sources must be supported by conventional equipment (nuclear reactors, municipal waste thermal treatment plants, boilers fired by local biomass, biogas, etc.). Moreover, heat and energy storage tanks should be used in these systems, and their rational operation requires the introduction of special solutions enabling intelligent energy supply and demand management. These issues are the subject of the article, while their analysis considers the specific national conditions.
8
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W artykule omówiono zagadnienie obliczenia parametrów operacyjnych węzła cieplnego w przypadku zmiany mocy zamówionej do ogrzewania i przygotowania ciepłej wody. Problem ten występuje w wielu systemach ciepłowniczych z powodu postępującej termomodernizacji budynków i projektowania nowych budynków zgodnie ze współczesnymi standardami ochrony cieplnej. W artykule wykorzystano programy komputerowe umożliwiające modelowanie stanów pracy instalacji i węzła cieplnego w zmienionych warunkach.
EN
In the article a problem concerning calculation of operating parameters of District Heating Substation in case of ordered capacity change have been discussed. The problem is important in a large group of District Heating Systems due to progress of thermomodernization of existing buildings and designing the new buildings in accordance to the contemporary thermal protection standards. Computer programs for simulation of DHS and building installation work at changed operating conditions were used.
9
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W cyklu artykułów przedstawiono zagadnienia dotyczące automatycznej regulacji parametrów operacyjnych węzłów ciepłowniczych. Omówiono podstawy teorii automatycznej regulacji, przedstawiono statyczną i dynamiczną charakterystykę członów regulacyjnych, podano zasady doboru elementów automatycznej regulacji w węzłach ciepłowniczych w miejskich systemach ciepłowniczych. Zbiór artykułów jest fragmentem przygotowanej do druku książki.
EN
In the set of articles issues concerning control of operating parameters of district heating substation have been presented. The basis of control theory, static and dynamic characteristics of control units, rules for selection of control system elements in urban district heating substations are given. The set of articles is a part of the book being prepared for printing.
10
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W cyklu artykułów przedstawiono zagadnienia dotyczące automatycznej regulacji parametrów operacyjnych węzłów ciepłowniczych. Omówiono podstawy teorii automatycznej regulacji, przedstawiono statyczną i dynamiczną charakterystykę członów regulacyjnych, podano zasady doboru elementów automatycznej regulacji w węzłach cieplnych w miejskich systemach ciepłowniczych. Zbiór artykułów jest fragmentem przygotowanej do druku książki.
EN
In the set of articles issues concerning control of operating parameters of district heating substation have been presented. The basis of control theory, static and dynamic characteristics of control units, rules for selection of control system elements in urban district heating substations are given. The set of articles is a part of the book being prepared for printing.
Przedstawiono działanie systemu ciepłowniczego obejmującego obieg centralnego ogrzewania oraz ciepłej wody użytkowej. Pokazano różnice architektury węzłów ciepłowniczych kompleksu uczelnianego AGH oraz Miasteczka Studenckiego AGH. Przedstawiono stan urządzeń automatyki w węzłach ciepłowniczych Miasteczka Studenckiego AGH oraz przedstawiono i przeanalizowano wyniki pomiarów z wybranego węzła.
EN
One presented functionality of heating system including circuit of central heating and hot tap water. One described differences of architecture of district heating substation of AGH complex building and AGH Student Campus. The state of automatic devices was shown in district heating substation of AGH Student Campus and also measurement results from exemplary substation was presented and analyzed.