From the World Health Organization (WHO) Thailand has reported from Wuhan, China, regarding the outbreak of novel coronavirus (COVID-19). Therefore, a novel wireless automatic body temperature sensing system (WA-BTSS) is proposed. WA-BTSS consists of three main functions, which are 1) sensing mode – 2) embedded microcontroller–WiFi chip, and 3) IoT communication network. The proposed novelty WABTSS screen the people who enter the building with long-distance detection of 50 cm. The infrared sensor used is high quality with medical accuracy. It works together with NodeMCU-ESP8266 Microcontroller, which module is embedded with a WiFi internet chip. The proposed IoTinnovation is to facilitate users in any organization due to the high security of personnel screening personnel entering and exiting the building. The performance of both body temperature devices was tested in terms of accuracy test based on the actual experiment, and then analyze the obtained results using the statistics program. The obtained results have shown the Cronbach's Alpha value of .752, and it can be summarized that the proposed WA-BTSS performance in terms of accuracy test is positively consistent with the standard model at a significant 95 % confidence level.
PL
Zaproponowano nowatorski bezprzewodowy system automatycznego wykrywania temperatury ciała (WA-BTSS). WA-BTSS składa się z trzech głównych funkcji, którymi są 1) tryb wykrywania - 2) wbudowany mikrokontroler - układ WiFi oraz 3) sieć komunikacyjna IoT. Proponowana nowość WA-BTSS ekran dla osób wchodzących do budynku z detekcją 50 cm. Zastosowany czujnik podczerwieni jest wysokiej jakości z medyczną dokładnością. Współpracuje z mikrokontrolerem NodeMCU-ESP8266, którego moduł jest osadzony w chipie internetowym WiFi. Proponowana innowacja IoT ma na celu ułatwienie użytkownikom w każdej organizacji dzięki wysokiemu bezpieczeństwu personelu sprawdzającego personel wchodzący i wychodzący z budynku. Działanie obu urządzeń do pomiaru temperatury ciała przetestowano pod kątem testu dokładności na podstawie rzeczywistego eksperymentu, a następnie przeanalizowano uzyskane wyniki za pomocą programu statystycznego. Uzyskane wyniki pokazały wartość Alfa Cronbacha wynoszącą 0,752 i można podsumować, że proponowane działanie WA-BTSS w zakresie testu dokładności jest pozytywnie zgodne z modelem standardowym przy istotnym 95% poziomie ufności.
W artykule omówiono badanie wpływu ustawień emisyjności cieplnej dla wybranego termometru bezkontaktowego (pirometru) na odczyt temperatury i błąd pomiaru. Podano w nim, jak na podstawie własnych badań sprawdzono właściwości wybranego pirometru pod tym względem. Zbadano różne materiały, określono ich emisyjność i zmierzono temperaturę bezkontaktow, a także za pomocą termopary. Wyniki pomiarów przedstawiono w postaci tabeli.
EN
Article describe influence of emissivity settings on pyrometer temperature measurement results. All information was received by measurement with pyrometer. Data was obtained by different types of materials. Surface temperature was also measured by thermocouple K.
Temperatura jest bardzo istotnym parametrem procesu podziemnego zgazowania węgla (PZW), warunkującym jego przebieg - również pod kątem bezpieczeństwa - oraz skład otrzymywanego gazu procesowego. Specyficzne środowisko pomiarowe jakie stanowi reaktor PZW utrudnia, a niekiedy praktycznie uniemożliwia, pomiar (metodami kontaktowymi) temperatury w jego wnętrzu. Dlatego stosowane do tej pory urządzenia termometryczne, nie spełniają w pełni wymogów procesu. Konieczne jest zatem, opracowanie nowych metod i urządzeń dopasowanych do warunków w jakich przebiega proces PZW tj. ciągłego pomiaru wysokiej temperatury (do ok. 2300 K), in situ, w obecności gazów palnych i wybuchowych (także w warunkach kopalnianych). Pociąga to za sobą konieczność przestrzegania wymogów dyrektywy ATEX w zakresie bezpieczeństwa przeciwwybuchowego. W artykule przedstawiono możliwość realizacji bezkontaktowego pomiaru temperatury w procesie podziemnego zgazowania węgla, zarówno w reaktorze in-situ jak i ex-situ. Podstawą działania bezkontaktowych urządzeń termometrycznych jest prawo Plancka oraz prawo przesunięć Wiena. Prawa te opisują ilość promieniowania elektromagnetycznego emitowanego ze źródła termicznego w funkcji temperatury, a w przypadku prawa Plancka, także długości fali (lub alternatywne częstotliwości). Opracowany system do pomiaru wysokiej temperatury w procesie PZW, wymagał zaprojektowania i wykonania niezbędnych podzespołów optycznych i mechanicznych oraz przeprowadzenia testów zdolności transmisyjnych zaprojektowanych elementów w reaktorze in-situ i ex-situ. Przeprowadzone eksperymenty potwierdziły możliwość przesyłania promieniowania temperaturowego przez zaprojektowane podzespoły optyczne, do detektora w urządzeniu pomiarowym, w postaci wymaganej do dalszego przetwarzania (sygnał optyczny). Umożliwi to bezkontaktowy pomiar wysokiej temperatury (do ok. 2300 K) w trakcie procesu podziemnego zgazowania węgla, wykorzystując opracowany (autorski) optoelektroniczny system pomiarowy, zintegrowany ze skanującym spektrometrem VIS-NIR oraz autorskim algorytmem wyznaczania wysokich temperatury.
EN
Temperature is one of the most significant parameters in the underground coal gasification (UCG) process – also for safety - which determines the progress of the process and composition of the UCG gas obtained. The specific measurement environment that is constituted by UCG reactor limits, and sometimes basically precludes, direct (contact) temperature measurement in the reactor’s interior. Hence, the thermometry devices, commonly utilized in the industrial applications, do not meet the requirements of the process of this kind, and therefore it is necessary to develop new methods and related equipment being well-adjusted to the UCG conditions i.e. a continuous measurement of high temperature (up to c.a. 2300 K) in situ, in the presence of flammable and explosive gases. (also in the mine’s conditions) . This implies the need to comply with the requirements of the ATEX Directive on safety in potentially explosive atmosphere in a mine. The paper presents the capability to carry out the non-contact temperature measurement, in the underground coal gasification process, both in situ and ex situ-located reactors. Planck’s law and Wien’s displacement law are the basis of operation of the non-contact thermometry devices. These basic laws describe the amount of electromagnetic radiation emitted by a thermal source, as a function of temperature and in the case of Planck’s law also wavelength (or alternative frequencies). The measuring system developed here for high temperature measurements in the process of underground coal gasification, imposed designing and constructing of indispensable optical and mechanical subassemblies and conductance of transmission capability tests of the designed elements in-situ and ex-situ UCG reactors. The conducted experiments confirmed the ability to transmit thermal radiation via designed optical subassemblies to a detector in a measuring unit in the form required for further processing (optical signal). This will allow for non-contact measurement of high temperature (of up to abt. 2300K) in the course of underground coal gasification process, using the purpose-developed (original) optoelectronic measuring system, integrated with the VIS-NIR scanning spectrometer and original algorithm for high temperature determination.
4
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Artykuł przedstawia zagadnienia związane z metodami termowizyjnymi oraz prezentuje próby, jakie pracownicy Zakładu Użytkowania Paliw Instytutu Nafty i Gazu przeprowadzili podczas badań prototypów urządzeń, dążąc do zastąpienia metod konwencjonalnych pomiaru temperatury pomiarem promieniowania podczerwonego, z zastosowaniem kamery FLIR GF320. Przedstawiono wnioski z przeprowadzonych badań i zwrócono uwagę na problemy i zalety bezkontaktowego pomiaru temperatury, starając się odnieść go do konwencjonalnych metod znormalizowanych.
EN
The paper presents issues related to thermal imaging methods and presents attempts which the staff of the Department of Fuel Usage of the Oil and Gas Institute in Krakow carried out during tests of prototypes, whilst trying to replace the conventional method of temperature measuring by measurement in infrared spectrum, using camera FLIR GF320. The article presents conclusions of the tests and highlights the advantages and disadvantages of noncontact temperature measurement, trying to relate it to the conventional normative methods.
Omówiono oryginalne rozwiązanie układu do bezkontaktowego pomiaru temperatury preform PET uplastycznianych w tunelu grzewczym maszyny do produkcji pojemników techniką rozdmuchiwania sprężonym powietrzem. Opisano szczegółowo poszczególne elementy toru pomiarowego oraz zastosowane algorytmy cyfrowego przetwarzania sygnału pomiarowego. Przedstawiono przykładowe rezultaty pomiarów zarejestrowane w trakcie rzeczywistego procesu produkcji opakowań z PET.
EN
Paper presents the original method of non-contact measuring the temperature of surface of PET preforms during reheating process in stretch blow moulding machine. Main parts of measuring chain were described as well as algorithms for digital signal processing. Example results of measures recorded in real manufacturing process were presented.
W artykule przedstawiono system pomiarowy do wyznaczania rozkładu temperatury modułów elektronicznych. Czujnik pirometryczny umożliwia wykonanie bezkontaktowych pomiarów temperatury. Przedstawiony system umożliwia badania dwu- lub trójwymiarowych rozkładów wartości temperatury płyt głównych komputerów PC lub central alarmowych. W drugiej części artykułu przedstawiono zrealizowane stanowisko pomiarowe do wykonywania badań środowiskowych typu burn-in.
EN
In this paper, the temperature mapping system for electronic devices is presented. The pyroelectronic temperature sensor enables non-contact measurements. The measured system provides two or three dimensions temperature scan of electronic modules as PC motherboards or security system motherboards. In the second part of this paper, the measurement system for thermal environment test on security system modules is presented.
Temperatura jest najczęściej mierzonym parametrem nieelektrycznym elementów i modułów elektronicznych. Związane jest to z bezpośrednią zależnością temperatury pracy elementu a jego niezawodnością. W artykule przedstawiono system pomiarowy umożliwiający wyznaczenie rozkładu temperatury modułów elektronicznych. Czujnik pirometryczny umożliwia wykonanie bezkontaktowych pomiarów temperatury. Przedstawiony system umożliwia przykładowo wykonanie dwu lub trójwymiarowych rozkładów wartości temperatury płyt głównych komputerów PC lub central alarmowych. W artykule zaprezentowano wyniki pomiarów temperaturowych wybranych układów elektronicznych.
EN
Temperature is one of the most common measured non-electric parameter of electronic devices and modules. This is due to its direct relationship to electronic reliability over time. In this paper the temperature mapping system for electronic devices is presented. The piroelectric temperature sensor enables non-contact measurements. The measured system provides two or three dimensions temperature scan of electronic modules as PC motherboards or security system motherboards. In this paper several temperature maps of electronics modules are presented, too.
Przedstawiono problemy występujące przy konstruowaniu urządzeń optoelektronicznych z detektorami podczerwieni, produkowanymi przez polską firmę VIGO System S.A. Zaprezentowano profil standardowej produkcji firmy i specyfikę współpracy z klientem nad projektami wykonywanymi wg indywidualnych wymagań, zwłaszcza wybrane projekty zrealizowane przez Wydział Elektroniki ww. firmy w ostatnich kilku latach. Szczególnie omówiono współpracę wzmacniaczy transimpedancyjnych z wysoko rezystancyjnymi źródłami sygnału o znacznej pojemności.
EN
This article presents a short scope of IR applications against a back-ground of Vigo - System's activity. Apart of standard IR products, a customer oriented approach has been described. It covers non-typical solutions designed according to our customer's requirements. Special attention has been paid to IR detectors and current mode (transimpedance) amplifiers, including selected methods of matching them. The article shows also some difficult problems faced by a designer, when high resistance IR detectors are used. In the final part of this work the prospects of development of the Polish IR market have been discussed.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.