For most of us, Saudi Arabia seems to be an exotic country - a land of rich sheikhs, oil and gas deposits, camels and deserts. Until recently, it was closed to outside visitors, but a few years ago the situation changed and now you can not only enter the country, but also travel around it without restriction. Its area is almost 7 times larger than Poland, covering about 2/3 of the territory of the Arabian Peninsula, with a population of only about 32 million, more than 53% of which is concentrated in several metropolises (Riyadh, Jeddah, Mecca, Medina, Al Damman). Large areas of the country are sparsely populated and covered by desert, including the world’s larg-est sand desert, Ar Rab al Khali. Small villages and settlements dominate, and some of the population still leads a nomadic lifestyle, following herds of camels. It is also an area with a diverse geological structure and a rich, centuries-old history. A kind of synthesis of these two aspects are old, historic buildings - their location, architecture, and above all, the materials from which they were built. The paper has the character of geological snapshots of the journey, showing these elements as examples of well-preserved or restored old buildings in some places, such as Thee Ain, Rial Almaa, Dhahran Al Janub, Jeddah, Hegra, Al Ula, Yanbu and Riyadh. Its aim is to present traditional building materials that have been used for centuries in the territory of present-day Saudi Arabia, and to draw attention to the untapped geotourism potential of the places where they were used. Analysing traditional building materials and their use provides valuable information on a regional material culture, as well as on the geodiversity of the region. Many buildings can therefore be admired not only as works of architecture and art, but also as geotourist attractions.
Ftalany (PAEs) są szeroko stosowanymi plastyfikatorami, które zwiększają elastyczność i trwałość tworzyw sztucznych, zwłaszcza PVC, wykorzystywanego m.in. w budownictwie. Ze względu na ich działanie zaburzające gospodarkę hormonalną wprowadzono ograniczenia dotyczące ich stosowania. W pracy przedstawiono wyniki badań dotyczących zanieczyszczenia powietrza ftalanami w pomieszczeniach mieszkalnych i biurowych oraz w warunkach laboratoryjnych z wykorzystaniem komór CLIMPAQ. Analiza wykazała obecność ftalanów w pięciu pomieszczeniach, przy czym najczęściej wykrywanym związkiem był DnBP, osiągający wartości do 53 μg/m³. Stwierdzono, że źródłem emisji były głównie wykładziny PVC, zwłaszcza starsze i uszkodzone.
EN
Phthalates (PAEs) are widely used plasticizers that enhance the flexibility and durability of plastics, particularly PVC, which is commonly applied in the construction sector. Due to their endocrine-disrupting effects, restrictions on their use have been introduced. The study presents the results of research on phthalate air pollution in residential and office environments as well as under laboratory conditions using CLIMPAQ chambers. The analysis confirmed the presence of phthalates in five rooms, with DnBP being the most frequently detected compound, reaching concentrations of up to 53 μg/m³. It was found that the main sources of emissions were PVC floor coverings, especially older and damaged ones.
3
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W artykule przedstawiono właściwości autoklawizowanego betonu komórkowego. Autor zaprezentował warianty ścian z ABK spełniające wymagania Warunków Technicznych.
EN
This article presents the properties of autoclaved aerated concrete. The author presents variants of AAC walls that meet the requirements of the Technical Conditions.
The publication presents the test method and construction of a compact VOC emission test chamber. Volatile organic compounds (VOCs) are mainly occur in paint and construction materials containing chemical resins, bitumen, binders, adhesives, etc., as well as residues of unreacted monomers. VOC emission testing is carried out on product samples in environmental chambers in accordance with PN-EN ISO 16000-9. The developed chamber, together with a proprietary control and test parameter acquisition system, allows testing at a stabilized temperature and humidity of air washing over the sample at a specified rate. Qualitative identification and quantitative testing of compounds present in the air inside chambers is carried out using a chromatograph, and the test results are compared with regulations on permissible chemical pollutants in the air of buildings and in atmospheric air. The developed chamber with horizontal sample loading is another version of VOC chambers, developed in response to market demands, offered and implemented in research laboratories by the Łukasiewicz Institute for Sustainable Technologies in Radom.
PL
Publikacja przedstawia metodę badań oraz budowę kompaktowej komory do badań emisji lotnych związków organicznych. Lotne związki organiczne (VOC) występują głównie w wyrobach malarskich oraz budowlanych zawierających żywice chemoutwardzalne, bitumy, lepiszcza, kleje itp., a także pozostałości nieprzereagowanych monomerów. Badanie emisji VOC odbywa się na próbkach wyrobów w klimatyzowanych komorach zgodnie z normą PN-EN ISO 16000-9. Opracowana komora wraz z autorskim systemem sterowania i akwizycji parametrów badań pozwala na prowadzenie badań w stabilizowanej temperaturze i wilgotności powietrza omywającego próbkę z określoną prędkością. Identyfikację jakościową i badanie ilościowe związków występujących w powietrzu komór przeprowadza się za pomocą chromatografu, a wyniki badań porównuje z przepisami dotyczącymi dopuszczalnych zanieczyszczeń chemicznych w powietrzu budynków i w powietrzu atmosferycznym. Opracowana komora z poziomym załadunkiem próbek jest kolejną wersją komór VOC, powstałą w odpowiedzi na oczekiwania rynku, oferowanych i wdrażanych w laboratoriach badawczych przez Ł-ITEE w Radomiu.
6
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Artykuł porusza kwestię obecności wody w strukturze materiałów budowlanych. Autor wymienia najczęściej występujące źródła zawilgocenia budynku oraz opisuje wielkości związane z wilgotnością materiałów budowlanych.
EN
The article raises the issue of the presence of water in the structure of building materials. The author lists the most common sources of moisture in the buildings and describes the values related to the moisture content in building materials.
7
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
This paper presents the application of BIM in energy modeling (BEM) processes. Examples from the literature demonstrating the validity of using BIM in energy simulation and analysis are presented, pointing out the benefits of these applications, which include energy efficiency, facilitating innovative design solutions, sustainability-oriented design and environmental protection, as well as the creation of comprehensive construction documentation. In order to investigate the usefulness of BIM and BEM technologies in the selection of energy-efficient, environmentally friendly building materials, energy analyses were performed in Archicad software with the built-in Energy Evaluation tool. The results, obtained in the form of reports, allow, among other things, the estimation of the annual energy demand necessary for heating the studied building and the cost of this energy. The purpose of the analyses was to select the most energy-efficient insulation material, hence a review of the insulation materials available on the market and their parameters was carried out.
PL
W artykule przedstawiono zastosowanie BIM w procesach modelowania energetycznego budynków (BEM). Zaprezentowano w nim przykłady z literatury pokazujące zasadność stosowania BIM w symulacjach i analizach energetycznych, wskazując korzyści płynące z tych zastosowań, do których zalicza się efektywność energetyczną, wprowadzenie innowacyjnych rozwiązań projektowych, projektowanie zorientowane na zrównoważony rozwój i ochronę środowiska, a także tworzenie kompleksowej dokumentacji budowlanej. W celu zbadania przydatności technologii BIM i BEM w doborze energooszczędnych, przyjaznych środowisku materiałów budowlanych wykonano analizy energetyczne w programie Archicad z wbudowanym narzędziem Energy Evaluation. Wyniki uzyskane w formie raportów pozwalają m.in. oszacować roczne zapotrzebowanie na energię niezbędną do ogrzania badanego budynku oraz koszt tej energii. Celem analiz był wybór najbardziej energooszczędnego materiału izolacyjnego, dlatego też dokonano przeglądu dostępnych na rynku materiałów izolacyjnych i ich parametrów.
8
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Artykuł porusza tematykę zastosowania mas KMB. Autor wymienia podłoża, na których mogą być stosowane, a także stawiane im wymagania. Na rysunkach przedstawiono przykłady wykonania detali z zastosowaniem mas KMB.
EN
The article discusses the issues of designing terraces on the ground. Materials used for both horizontal and vertical insulation are discussed. The illustrations show the layers and eaves of a terrace on the ground with a tile floor, as well as a terrace on the ground with drainage.
Prace budowlane i rozbiórkowe prowadzone na terenie Unii Europejskiej każdego roku generują około 750 milionów ton odpadów. Stanowi to aż 30% odpadów dla wszystkich odpadów krajów Wspólnoty. Należy dodać, że przemysł budowlany generuje aż 11% światowej emisji dwutlenku węgla. W obliczu wyzwań związanych z koniecznością ochrony klimatu recykling materiałów budowlanych jest dobrym rozwiązaniem, mającym na względzie ekologię i ekonomię.
The space in which young people learn undoubtedly has an impact on the quality and effectiveness of learning. Following this lead, the project team, supported by participatory activities, created the concept of a modular mobile classroom that responds to contemporary environmental and social challenges.
The article provides an overview of energy consumption in buildings, particularly residential ones. Key aspects of building design are discussed, such as the selection of construction technologies and materials, which impact the building’s energy efficiency and operational costs. The thermal insulation requirements, regulated by legal provisions, are presented, setting the maximum allowable values for thermal transmittance and the consumption of non-renewable primary energy by the building. The research section includes analyses for a multi-family building designed to be located in Czestochowa, highlighting different variants for external walls, flat roofs, ceilings over unheated basements, as well as window and door joinery, all aimed at achieving optimal energy performance. The conducted analyses considered thermal, moisture, and economic para-meters. For each building partition analysed, three variants were examined, all of which complied with the current Technical Requirements. When selecting materials for the building partitions, factors such as low costs, material availability, and ease of installation were prioritized to minimize errors. Risks related to water vapor condensation were also analysed. The chosen variants, through the selection of materials and construction techniques, allow for achieving high energy efficiency in the building while optimizing construction and operational costs, thereby improving occupant comfort and reducing CO2 emissions.
12
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The global construction industry, notorious for resource consumption and waste production, has found an interest in the circular economy and sustainable development practices. This paper examines the reusability of ceramic building materials within architectural designs, emphasizing the principles of the circular economy and the 3R concept with a special focus on reuse. By performing a comparative analysis of 26 buildings the research explores the strategies for reusing ceramic materials. It categorizes reuse into two approaches: recreation and transformation, while also considering the prevention of materials from becoming waste. The analysis scrutinizes the origin and function of materials, their placement in new designs, and the reasons behind their reuse. The study delineates recurring design patterns of using reclaimed building materials. It also categorizes three main approaches to incorporating reused elements into new structures.
The article presents the application of the time domain reflectometry (TDR) technique for measuring the moisture of porous building materials used in construction. The work is focused on using the potential of artificial intelligence to improve the quality of TDR measurements through a new approach to the interpretation of data obtained from the TDR readings. Machine learning is a data analysis technique, used nowadays in many scientific disciplines. The authors performed a measurement data analysis using the artificial intelligence algorithms to assess moisture of aerated concrete samples tested with a TDR multimeter using two non-invasive sensors which differ in thickness. Data analysis was carried out using supervised machine learning to analyse a series of reflectograms obtained during the measurement. For the data achieved by the classical and machine learning method interpretation, correlation analysis was conducted to confirm the potential of artificial intelligence to improve the quality of TDR measurement. The summary of the work discusses the obtained analytical results and highlights the effectiveness of moisture assessment using the Gaussian Process Regression method, which allowed achieving a level of 0.2 - 0.3% of the RMSE errors value, which is about 10 times lower than the traditional approach.
The aim of the article is to analyse the influence of the wall positioning in relation to the incidence of a plane wave on the values of the electric field intensity. The subject of the analysis was an isolated system with a brick wall. Two commonly used types of bricks were considered: solid brick as a homogeneous material and hollow brick (clinker) considered as a heterogeneous material. The performed analysis also took into account various values of the electrical parameters of the ceramic material (permittivity and conductivity), which are used in the calculations. The distribution of the electric field strength generated by a wireless communication system operating at a frequency of 5 GHz is presented. The numerical finite difference time domain (FDTD) method was used. The influence of the drilling on the field intensity values in the area behind the wall is discussed. The obtained results may be useful when estimating the value of the damping coefficient for non-homogeneous materials, taking into account the angle of incidence of the plane wave.
PL
Celem artykułu jest analiza wpływu ustawienia ściany względem kąta padania fali płaskiej na wartości natężenia pola elektrycznego. Przedmiotem analizy był odosobniony układ zawierający ścianę wykonaną z cegieł. Rozpatrzono dwa powszechnie stosowane rodzaje cegieł: cegłę pełną, jako materiał jednorodny oraz cegłę z drążeniami (klinkierową) rozpatrywaną jako materiał niejednorodny. Dokonana analiza uwzględniała także różne wartości parametrów elektrycznych materiału ceramicznego (przenikalności elektrycznej i konduktywności), które są stosowane w obliczeniach. Zaprezentowany został rozkład natężenia pola elektrycznego generowanego przez system komunikacji bezprzewodowej pracujący przy częstotliwości 5 GHz. Zastosowano numeryczną metodę różnic skończonych w dziedzinie czasu (FDTD). Omówiono wpływ drążeń na wartości natężenia pola w obszarze za ścianą. Uzyskane wyniki mogą być przydatne przy szacowaniu wartości współczynnika tłumienia dla materiałów niejednorodnych przy uwzględnieniu kąta padania fali płaskiej.
15
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W artykule omówiono praktyczne wykorzystanie materiałów kompozytowych współcześnie stosowanych przy wzmacnianiu istniejących konstrukcji. Zaprezentowano przekrój możliwych zastosowań i objaśniono słuszność i zasady ich doboru. W publikacji można też odnaleźć informacje na temat optymalnych sposobów stosowania wzmocnień zależności od konstrukcji wymagającej wzmocnienia.
EN
The article discusses the practical use of composite materials currently employed in strengthening existing structures. It presents an overview of possible applications and explains the rationale and principles for their selection. The publication also provides information on optimal methods for applying reinforcements, depending on the structure in need of strengthening.
16
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Przedmiotem artykułu są materiały stosowane do wtórnej hydroizolacji budynków – membrany z tworzyw sztucznych i kauczuku. Autor analizuje zagadnienia związane ze stosowaniem folii i membran, zajmuje się hydroizolacją przyziemi budynków, po czym przechodzi do omówienia norm krajowych i międzynarodowych. Uwagę poświęca także mocowaniu membran do podłoża oraz wrażliwości membran na uszkodzenia mechaniczne.
EN
The article focuses on materials used for secondary waterproofing of buildings − plastic and rubber membranes. The author analyzes the issues related to the use of films and membranes, deals with waterproofing the basement of buildings, and then discusses national and international standards. He also pays attention to fixing the membranes to the substrate and the sensitivity of the membranes to mechanical damage.
17
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W artykule opisano metodę wzmacniania konstrukcji przy pomocy kompozytów FRCM. Przedstawiono wady i zalety stosowania kompozytów wykonanych z włókien PBO i wykazano słuszność ich stosowania przy wzmacnianiu obiektów inżynierskich, zarówno współczesnych, jak i zabytkowych. Opisano też badania podjęte w Katedrze Konstrukcji Budowlanych Politechniki Śląskiej.
EN
The article describes the method of strengthening the structure with the use of FRCM composites. The advantages and disadvantages of using composites made of PBO fibers were presented and the validity of their use in the reinforcement of engineering structures – modern and historic – was demonstrated. Research undertaken at the Department of Building Structures of the Silesian University of Technology is also described.
18
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Artykuł porusza tematykę wymagań, które powinny spełniać cienkowarstwowe zaprawy murarskie. Autorzy zwracają uwagę zarówno na parametry deklarowane, jak i te istotne dla wykonawców. Omawiają zasady aplikacji zapraw.
EN
The article describes the requirements that has be met by thin-bed mortars. The authors pay outlines both the declared parameters and those important for contractors as well as principles of mortar application.
19
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W artykule poruszono temat uszczelniania rys i złączy metodą iniekcji, z podziałem na środki iniekcyjne na bazie żywic epoksydowych, poliuretanów, akrylanów, żywic poliakryloamidowych, materiały cementowe i mikrocementowe oraz materiały polimerowo-cementowe.
EN
The article addresses the issues concerning sealing cracks and joints by injection, divided into injection agents based on epoxy resins, polyurethanes, acrylates, polyacrylamide resins, cement and microcement materials, as well as polymer-cement materials.
20
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W artykule przedstawiono charakterystykę prac termomodernizacyjnych, zasady ocieplenia przegród od zewnątrz i wewnątrz oraz przykłady obliczeniowe w zakresie kształtowania parametrów fizykalnych przegród zewnętrznych i ich złączy po dociepleniu.
EN
The article presents the characteristics of thermal modernization works, the principles of insulation of partitions from the outside and inside, and calculation examples in the field of shaping the physical parameters of external partitions and their joints after thermal insulation.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.