Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 56

Liczba wyników na stronie
first rewind previous Strona / 3 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  energy analysis
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 3 next fast forward last
EN
Maximizing energy efficiency of buildings is essential to meet EU climate targets and strict national regulations. We examine how local climate influences energy performance of residential building and mitigation options. A model of single-family house was analyzed in whole year energy simulation software WUFI Plus. Three Polish locations were investigated, namely Wrocław, Warszawa and Kołobrzeg. Implementation of the original meteorological dataset into WUFI Plus based on typical meteorological year (2005–2023) is a novel element of this work. Hourly heat and mass transfer, usable, final and primary energy indicators, and CO2 emissions were calculated for a gas-boiler baseline and two alternatives: an air-to-water heat pump, and air-to-water heat pump with photovoltaic panels. Results for the gas-boiler scenario show location-dependent heating demand differences up to 30%; usable energy for heating ranged from 7561 to 9760 kWh/year, and EP of the system from 114 to 129 kWh/(m2·year). Replacing the boiler with an air-to-water heat pump reduced final energy indicator by over 60% but produced similar CO2 due to Poland’s carbon-intensive electricity mix. Adding photovoltaic system, that covers electricity demand only of auxiliary equipment, cut CO2 emissions by about 10%. These findings highlight the importance of climate-specific meteorological inputs and on-site renewables to meet forthcoming energy performance standards.
PL
W artykule przedstawiono porównanie i analizę dwóch sposobów montażu modułów fotowoltaicznych uwzględniającą efektywność energetyczną i koszty inwestycji dla przedsiębiorstwa z sektora produkcyjnego. Przeprowadzono badania symulacyjne dla dwóch konfiguracji instalacji fotowoltaicznych (PV) – w konfiguracji południowej oraz wschód - zachód. W symulacji uwzględniono lokalne warunki atmosferyczne i rzeczywiste ceny energii i zapotrzebowanie energetyczne przedsiębiorstwa. Na podstawie analizy wyników symulacji ustalono rekomendacje wspomagające przedsiębiorstwa w podejmowaniu decyzji dotyczących inwestycji w systemy fotowoltaiczne, z uwzględnieniem optymalizacji kosztów i efektywności energetycznej dla zaproponowanych konfiguracji.
EN
The article presents a comparison and analysis of two methods for mounting photovoltaic modules, taking into account energy efficiency and investment costs for a company in the manufacturing sector. Simulation studies were conducted for two configurations of photovoltaic (PV) installations – in a south-facing configuration and an east-west configuration. The simulation considered local weather conditions as well as actual energy prices and the energy demand of the company. Based on the analysis of the simulation results, recommendations were established to assist companies in making decisions regarding investments in photovoltaic systems, with a focus on cost optimization and energy efficiency for the proposed configurations.
PL
Na całym świecie trwa intensywna modernizacja sektora energetycznego, z tego względu w artykule omówiono wybrane aspekty dotyczące dekarbonizacji na przykładzie polskiej energetyki. Poruszono również kwestie dotyczące aktualnego miksu energetycznego, planowanych wyłączeń elektrowni systemowych oraz kluczowych zagadnień związanych z eksploatacją technologii jądrowych. Ponadto zaprezentowano wyniki analizy energetycznej, przeprowadzonej na modelach komputerowych, obiegów wtórnych elektrowni jądrowej (z wykorzystaniem programu EBSILON®Professional).
EN
Intensive modernization of the energy sector is underway around the world, therefore the article discusses selected aspects of decarbonization on the example of Poland. Issues related to the current energy mix, planned shutdowns of system power plants and key points related to the operation of nuclear technologies were also discussed. In addition, the results of the energy analysis carried out on computer models of secondary circuits of a nuclear power plant (using the EBSILON®Professional program) were presented.
PL
W artykule przedstawiono analizę zużycia energii elektrycznej przez budynek uczelni wyższej w Warszawie oraz ocenę możliwości jego redukcji w zależności od przyjętego poziomu nakładów inwestycyjnych. Przeprowadzono symulację i ocenę opłacalności instalacji fotowoltaicznej. Określono również potencjał wykorzystania magazynu energii w celu ograniczenia kosztów oraz zapewnienia autonomiczności energetycznej. W wyniku analizy po zastosowaniu wszystkich działań oraz inwestycji zaproponowanych w artykule uzyskano prawie 70% rocznej redukcji kosztów energii elektrycznej.
EN
The article presents an analysis of electricity consumption by a university building in Warsaw, along with an assessment of the potential for its reduction depending on the level of investment. A simulation and assessment of the profitability of the PV installation were carried out. The potential of using an energy storage facility to reduce costs and ensure energy autonomy was also determined. As a result of the analysis, after applying all the actions and investments proposed in the article, an almost 70% annual reduction in electricity costs was achieved.
PL
Instalacje fotowoltaiczne (PV) stały się bardzo powszechnym źródłem pozyskiwania energii elektrycznej. Obowiązujące w ostatnim okresie regulacje prawne w zakresie pozyskiwania „zielonej energii” oraz różne formy wsparcia finansowego, wpłynęły na bardzo dynamiczny przyrost budowanych i użytkowanych instalacji PV. W artykule porównano roczne uzyski energii z rzeczywistych instalacji PV zlokalizowanych w miejscowości Częstochowa – trzech instalacji PV stacjonarnych oraz jednej instalacji nadążnej. Instalacje PV wybudowane są w promieniu 2 km pomiędzy sobą.
EN
Photovoltaic (PV) installations have become a very common source of acquiring of electrical energy. The last legal regulations concerning of "green energy" acquisition and various forms of financial support have resulted in a very dynamic increase in the number of PV installations built and used. The paper compares the annual energy yields from real PV installations built in Czestochowa - three stationary PV installations and one follow-up installation. PV installations are built within a radius of 2 km between each other.
PL
Celem artykułu jest porównanie budynku przykładowego z dwoma typami dachów, pierwszy z klasycznym dachem z konstrukcją drewnianą, membraną i pokryciem, drugi – zielony ze niezbędnymi warstwami (modelem pobranym ze strony producenta). W niniejszym artykule zostaną zaprezentowane wyniki z modelu, wykonanego w programie Autodesk Revit oraz przeanalizowanego przez program Autodesk Insight, jednego budynku o wariantowym rodzaju dachu. Zielony dach został wybrany do analizy ze względu na właściwości oferowane przez tę technologię, nie tylko dobrze znane właściwości termiczne, ale także dodatkowe aspekty, takie jak obniżenie zużycia energii oraz pozytywny wpływ na środowisko.
EN
The purpose of this paper is to compare an example building with two roof types, the first with a classic roof with timber structure, membrane and covering, the second with a green roof with the necessary layers (model downloaded from the manufacturer’s website). This paper will present results from a model, made in Autodesk Revit and analysed by Autodesk Insight, of one building with a variant roof type. The green roof was chosen for the analysis because of the properties offered by this technology, not only the well-known thermal properties, but also additional aspects such as reduced energy consumption and positive environmental impact.
PL
Rosnące ceny energii elektrycznej, potrzeba ograniczania emisji gazów cieplarnianych oraz rozwój odnawialnych źródeł energii uzasadniają konieczność oceny efektywności energetycznej i ekonomicznej przydomowych instalacji fotowoltaicznych w warunkach klimatycznych Polski. Szczególnie istotne jest określenie rzeczywistych korzyści wynikających z ich eksploatacji na podstawie danych rzeczywistych. Celem pracy była analiza energetyczna i ekonomiczna przydomowej instalacji fotowoltaicznej o mocy 3 kWp zlokalizowanej w Rzeszowie, obejmująca ocenę produkcji energii, stopnia pokrycia zapotrzebowania gospodarstwa domowego, poziomu autokonsumpcji oraz opłacalności inwestycji. Badania przeprowadzono na podstawie danych eksploatacyjnych z lat 2022–2023, udostępnionych przez prosumenta. Analizie poddano miesięczne wartości energii wyprodukowanej, wprowadzonej do sieci, pobranej z sieci, zużytej w gospodarstwie domowym oraz koszty zakupu energii w wariancie z instalacją PV i bez niej. Wyniki wykazały wyraźną sezonowość pracy instalacji oraz średnie pokrycie zapotrzebowania energetycznego na poziomie 78,41%. Instalacja umożliwiła redukcję kosztów energii elektrycznej o 31–34% w analizowanym okresie, a okres zwrotu inwestycji oszacowano na około 8 lat, co potwierdza jej zasadność energetyczną i ekonomiczną.
EN
Rising electricity prices, the need to reduce greenhouse gas emissions, and the development of renewable energy sources justify the necessity of assessing the energy and economic efficiency of residential photovoltaic installations under Polish climatic conditions. In particular, it is important to determine the actual benefits resulting from their operation based on real data. The aim of this study was to perform an energy and economic analysis of a residential photovoltaic installation with a capacity of 3 kWp located in Rzeszów, including an assessment of energy production, the degree of household energy demand coverage, the level of self-consumption, and the profitability of the investment. The analysis was based on operational data from 2022–2023 provided by the prosumer. Monthly values of energy produced, fed into the grid, drawn from the grid, and consumed by the household were analyzed, as well as electricity purchase costs for scenarios with and without a PV installation. The results demonstrated a clear seasonal pattern in system operation and an average household energy demand coverage of 78.41%. The photovoltaic installation enabled a reduction in electricity costs by 31–34% over the analyzed period, while the payback period of the investment was estimated at approximately 8 years, confirming both its energy and economic viability.
8
Content available remote Energy and exergetic analysis of the transmission system
EN
The article discusses the energy and exegetic analysis of the gas transmission system using real network.
PL
W artykule na przykładzie omówiono analizę energetyczną i egzegetyczną gazowego systemu przesyłowego.
PL
W artykule przedstawiono wyniki analizy ekonomicznej działań koniecznych do wdrożenia w celu spełnienia wymagań wynikających z aktualizacji programu budownictwa socjalnego i komunalnego (BSK). Wymagania te dotyczą pożądanego standardu energetycznego dla którego wartość wskaźnika rocznego zapotrzebowania na nieodnawialną energię pierwotną EP nie może przekraczać 52 kWh/(m2rok). Przeanalizowano łącznie 25 wariantów technicznych, w tym jeden pierwotnie zaprojektowany, z czego sześć w zakresie architektonicznym, osiem w zakresie instalacji sanitarnych oraz dziesięć w zakresie instalacji pozyskujących energię odnawialną. Najkorzystniejszymi rozwiązaniami ze względu na koszty eksploatacyjne zmienne i stałe są rozwiązania bazujące na wykorzystaniu pomp ciepła typu powietrze-woda oraz pomp ciepłą typu glikol-woda wsparte instalacją fotowoltaiczną o mocy 33,78 kWp pokrywająca całą dostępną powierzchnią dachu w przedmiotowym budynku. Roczne całkowite koszty eksploatacyjne dla tych rozwiązań są niższe od rozwiązania bazowego o odpowiednio 76,80% i 81,57%. Znaczące środki finansowe, które można uzyskać w ramach przedmiotowego programu przy uwzględnieniu dodatkowych środków w postaci uzyskania grantu OZE powoduje, że warianty bazujące na wykorzystaniu rozwiązań alternatywnych finalnie stają się tańsze o ok. 35,0% całkowitych kosztów inwestycyjnych od rozwiązania bazowego. Ta stymulacja powinna ukierunkować decydentów w kierunku podjęcia decyzji o budowie budynków energooszczędnych zgodnie z wytycznymi programu wsparcia.
EN
The article presents the results of the economic analysis of the measures necessary to implement in order to meet the requirements resulting from the update of the social and municipal housing program (BSK). These requirements apply to the desired energy standard for which the value of the annual demand for non-renewable primary energy EP cannot exceed 52 kWh/(m2year). A total of 25 technical variants were analysed, including one originally designed, of which six architectural variants, eight sanitary installations and ten renewable energy installations. The most advantageous solutions in terms of variable and fixed operating costs are solutions based on the use of air-water heat pumps and glycol-water heat pumps supported by a photovoltaic installation with a capacity of 33.78 kWp covering the entire available roof area in the building. The annual total operating costs for these solutions are lower than the base solution by 76.80% and 81.57%, accordingly. Significant financial resources that can be obtained under the program in question, taking into account additional funds in the form of obtaining a RES grant, make the variants based on the use of alternative solutions ultimately cheaper by approx. 35.0% of the total investment costs than the base solution. This stimulation should direct decision-makers towards making decisions on the construction of energy-efficient buildings in accordance with the guidelines of the support programme.
PL
W obliczu rosnących kosztów energii analiza egzergii staje się kluczowa dla zwiększenia efektywności energetycznej, szczególnie w sektorach przemysłowych wykorzystujących parę wodną. Badanie koncentruje się na ocenie strat egzergii w systemach nieustalonych i ściśliwych, przy zastosowaniu zaawansowanych technik symulacyjnych, takich jak OpenFOAM CFD. Wykorzystując twierdzenie o transporcie Reynoldsa, analiza zapewnia wgląd w straty jakości energii i efektywność pomiaru w systemach przemysłowych. Dokładność pomiaru wyznaczono wg normy, przez co wyniki oparte są na wiarygodnych wnioskach. Badanie podkreśla potrzebę zmiany założeń w projektowaniu i funkcjonowaniu systemów pomiaru strumienia masy dla mediów ściśliwych. Potrzeba ta wynika z możliwego do osiągnięcia zwiększenia jakości transportowanej energii, która to jakość jest mierzona jako wartość egzergii strumienia płynu.
EN
Simulation studies on the detn. of the amt. of energy and exergy in a flowmeter based on the measurement of the pressure difference at a measuring nozzle installed in a steam pipeline were presented. The simulation was performed in the CFD OpenFOAM program using the k-ω-SST 2006 turbulence model. The amt. of total stream energy and exergy losses in the measuring section of the steam flow through the measuring element was detd. A decrease in energy qual. in mass flow measurement systems was demonstrated.
PL
W polskich przedsiębiorstwach, po wielu latach braku szczególnej uwagi w obszarze zarządzania energią, widzimy efekt planowanych i wdrażanych działań transformacyjnych. Dlatego właśnie dla transformacji energetycznej warto przyjąć optykę przedsiębiorcy. Które trendy oraz zmiany mają szansę rozwinąć łańcuch energetyczny, a jakie ryzyka spowolnią proces dekarbonizacji?
PL
Odgazowanie jest krytyczną czynnością konserwacyjną instalacji wody ogrzewczej i chłodzącej. Skutecznie usuwając rozpuszczone gazy i uwięzione powietrze, odgazowanie zapewnia optymalną wydajność wymiany ciepła, zmniejsza korozję i hałas, zapobiega powstawaniu śluz powietrznych i kawitacji oraz wydłuża żywotność elementów systemu. Stosowanie metod, takich jak: odpowietrzanie ręczne lub automatyczne, odgazowywanie próżniowe, odgazowywanie termiczne czy separatory odśrodkowe mogą znacznie poprawić wydajność i niezawodność systemów ogrzewczych. Zastosowanie układu odgazowania próżniowego oraz separatora zanieczyszczeń podnosi efektywność energetyczną i pozwala na obniżenie zużycia energii. Sam układ odgazowania próżniowego pozwala zwiększyć efektywność energetyczną instalacji ogrzewczych, odpowiednio dla instalacji grzejnikowej do 4,7%, a dla instalacji ogrzewania podłogowego do 5,1%, natomiast dla instalacji chłodniczych do 4,2%. Układ odgazowania próżniowego wraz z separatorem zanieczyszczeń pozwala zwiększyć efektywność energetyczną instalacji ogrzewczych, odpowiednio dla instalacji grzejnikowej do 6,5%, a dla instalacji ogrzewania podłogowego do 10,6%, natomiast dla instalacji chłodniczych do 10,3%. Zastosowanie odgazowania próżniowego przyczynia się do realizacji celów zrównoważonego rozwoju, zmniejsza zużycie energii, a tym samym zmniejsza emisję CO2 do środowiska, ponadto pozwala znacząco obniżyć koszty eksploatacji przy niskich kosztach inwestycyjnych i łatwości aplikacji rozwiązania.
EN
Degassing is a critical maintenance procedure for heating and cooling water systems. By effectively removing dissolved gases and entrapped air, degassing ensures optimum heat transfer efficiency, reduces corrosion and noise, prevents airlocks and cavitation, and extends the life of system components. The use of methods such as manual venting, automatic venting, vacuum venting, thermal venting, and centrifugal separators can significantly improve the efficiency and reliability of heating systems. The use of a vacuum venting system and a dirt separator increases energy efficiency which implicates reduced energy consumption. The vacuum venting system alone can increase the energy efficiency of heating systems, up to 4.7% for radiator systems, up to 5.1% for underfloor heating systems, and up to 4.2% for refrigeration systems. The vacuum venting system together with a vacuum dirt separator can increase the energy efficiency of heating systems, up to 6.5% for radiator systems, up to 10.6% for underfloor heating systems, and up to 10.3% for refrigeration systems. The use of vacuum degassing contributes to the achievement of sustainable development goals, reduces energy consumption and thus reduces CO2 emissions into the environment, and also allows for a significant reduction in operating costs with low investment costs and ease of application of the solution.
13
Content available remote Analiza wariantów zaopatrzenia w energię budynku pasywnego
PL
W artykule przedstawiono analizę trzech wariantów zaopatrzenia w energię budynku pasywnego. Pierwszy wariant to grzejniki niskotemperaturowe z kotłem gazowym kondensacyjnym, drugi wariant to ogrzewanie podłogowe z powietrzną pompą ciepła, a trzeci wariant to również ogrzewanie podłogowe, lecz z gruntową pompą ciepła. W artykule podano ogólny opis budynków pasywnych, charakterystykę analizowanego budynku, a także narzędzi obliczeniowych, których użyto do wykonania obliczeń. Obliczono wskaźniki rocznego zapotrzebowania na energię użytkową, energię końcową oraz nieodnawialną energię pierwotną w każdym z analizowanych wariantów zaopatrzenia w energię. W dalszej części artykułu obliczone wskaźniki poddano analizie, a także porównano je w celu wyznaczenia najkorzystniejszego rozwiązania dla analizowanego budynku. Dodatkowo przeanalizowano koszty inwestycyjne oraz koszty dostawy energii w każdym z wariantów i obliczono współczynnik SPBT. Najkorzystniejszym systemem ogrzewania analizowanego budynku okazał się wariant pierwszy.
EN
The article presents an analysis of three variants for the energy supply of a passive house. The first variant is low-temperature radiators with a condensing gas boiler, the second variant is underfloor heating with an air-source heat pump, and the third variant is also underfloor heating, but with a ground-source heat pump. The article includes a general description of passive buildings, the characteristics of the analyzed building, as well as the calculation tools that were used to perform the calculations. For each of the variants, the indices of annual demand for usable energy, final energy and non-renewable primary energy were calculated. In the remainder of the article, the calculated indices are analyzed, and a comparison is made as to which variant is most beneficial for the analyzed building. In addition, the investment and energy supply costs for each variant were analyzed and the SPBT coefficient was calculated. The most favorable heating system for the analyzed building turned out to be the first variant.
PL
W ostatnich miesiącach, w wielu czasopismach branżowych mogliśmy natrafić na publikacje dotyczące chłodzenia adiabatycznego, jego energooszczędności i zalet. W ocenie autora niniejszego artykułu, brakuje jednak w tych publikacjach twardych danych popierających postawione w nich tezy, a część z nich zwyczajnie mija się z prawdą, gdyż autorzy nie wykazali z czego wynikają owe oszczędności czy zalety. Dlatego proponuję przyjrzeć się bliżej przemianom chłodzenia adiabatycznego ze stosownymi analizami na wykresie psychrometrycznym, a na koniec wyciągniemy obiektywne wnioski, wady i zalety takich systemów.
EN
Purpose: The research objective of the work is to quantify the levels of profitability of a photovoltaic installation for a company from the clothing industry. The authors of the article answer the question of where and under what boundary conditions in Poland there is already economic justification for the construction of photovoltaic power plants producing energy for the needs of their own business activity. Design/methodology/approach: The study was conducted using the methods of models of economic measures. These methods allowed the authors to calculate the market value of the investment with the assumed boundary criteria and to determine the economic efficiency of the investment. In addition, the authors made an analysis of the energy consumption of the company's implementation of individual manufacturing processes. The research was carried out in the period 2020-2022 on the example of a real PV installation. Findings: Installing a photovoltaic system in production plants brings many benefits. It should be noted that each kWh produced in a PV installation makes the investor independent of the grid distributor, reduces the consumption of energy from conventional sources, minimizes the emission of pollutants into the atmosphere and favors economic development. In addition, investment in this type of installation allows for obtaining income from the sale of surplus energy produced. Practical implications: The presented models have shown that the project of their implementation is fully economically justified and will allow investors to make a rational investment decision. Originality/value: The contribution of this work is to obtain data that allowed the authors to indicate directions for improvement that may contribute to a more reliable assessment of the profitability of the tested installations. The proposed research can improve the planning of new industrial plants in terms of PV Installations as well as the redesign of existing ones.
PL
W rozdziale przedstawiono przykłady inwestycji w technologie wodorowe w Polsce. Przedstawiono wyniki analizy energetycznej układu farma fotowoltaiczna–elektrolizer do produkcji czystego, zielonego wodoru. Zdefiniowano wzór na czas wykorzystania mocy zainstalowanej elektrolizera zasilanego z farmy PV oraz wyznaczono jego wartość. Przedstawiono profil produkcji energii elektrycznej przez farmę PV. Obliczenia wykonano na podstawie danych nasłonecznienia dla lokalizacji miasta Poznania. Przytoczono wzór na wartość mocy generowanej przez farmę PV oraz wzory pozwalające określić roczną wartość masy wyprodukowanego wodoru. Przebadano wpływ wartości stosunku mocy elektrolizera do mocy farmy fotowoltaicznej (PEL/PPV) na wartość czasu wykorzystania jego mocy zainstalowanej. Wyniki analizy przedstawiono w formie graficznej za pomocą charakterystyki PEL/PPV = f(TEL). Zaproponowano metodologię doboru mocy i pojemności baterii elektrochemicznej w celu zwiększenia produkcji wodoru.
EN
The chapter presents examples of investments in hydrogen technologies in Poland. The results of the energy analysis of the photovoltaic farm-electrolyser system for the production of pure, green hydrogen are presented. The formula for the use of the installed power of the electrolyser supplied from a PV farm was defined and its value was determined. The profile of electricity production by a PV farm was presented. The calculations were made on the basis of insolation data for the city of Poznań. The formula for the value of the power generated by the PV farm and the formulas allowing to determine the annual value of the mass of produced hydrogen were presented. The influence of the ratio of the electrolyser power to the power of a photovoltaic farm (PEL/PPV) on the value of the utilization time of its installed power was investigated. The results of the analysis are presented graphically by means of the PEL/PPV = f(TEL) characteristic. A methodology for selecting the power and capacity of an electrochemical battery was proposed to increase hydrogen production.
PL
W artykule przedstawiono wyniki analizy energetycznej działań koniecznych do wdrożenia dla zaprojektowanego zgodnie z WT 2021 budynku mieszkalnego wielorodzinnego zlokalizowanego w miejscowości Świdnica należącego do Świdnickiego Towarzystwa Budownictwa Społecznego sp. z o.o. w celu spełnienia wymagań wynikających z aktualizacji programu budownictwa socjalnego i komunalnego (BSK). Wymagania te dotyczą pożądanego standardu energetycznego dla którego wartość wskaźnika rocznego zapotrzebowania na nieodnawialną energię pierwotną EP nie może przekraczać 52 kWh/(m2rok). Przeanalizowano łącznie 25 wariantów technicznych, w tym jeden pierwotnie zaprojektowany, z czego sześć w zakresie architektonicznym, osiem w zakresie instalacji sanitarnych oraz dziesięć w zakresie instalacji pozyskujących energię odnawialną. Nie wszystkie z analizowanych wariantów przyczyniły się do redukcji zapotrzebowania na nieodnawialną energię pierwotną. Wyłącznie 8 wariantów z 25 analizowanych pozwoliło uzyskać zadowalający wynik. Najniższą wartość współczynnik EP wynoszącą 13,45 kWh/(m2rok) uzyskano dla wariantu O10 polegającego na zastosowaniu instalacji fotowoltaicznej o mocy 33,78kWp, która pokrywa 100% dostępnej powierzchni dachu dla rozwiązania bazującego na wykorzystaniu jako źródła ciepła pompy ciepła typu glikol-woda z niskoparametrową instalacją centralnego ogrzewania i przepływowym sposobem podgrzewu CWU, a także z instalacją wentylacji mechanicznej wyciągowej higrosterowalnej. Wykazano, że stosowanie odnawialnych źródeł energii (OZE) przyczynia się do zmniejszenia zapotrzebowania na nieodnawialną energię pierwotną.
EN
The article presents the results of the energy analysis of the measures necessary to be implemented for multi-family residential building designed in accordance with WT 2021, located in Świdnica, belonging to Świdnickie Towarzystwo Budownictwa Społecznego sp. z 0.0. in order to meet the requirements resulting from the update ofthe social and municipal housing program (BSK). These requirements apply to the desired energy standard for which the value of the annual demand for non-renewable primary energy EP cannot exceed 52 kWh/(mzyear). A total of 25 technical variants were analysed, including one originally designed, of which six architectural variants, eight sanitary installations and ten renewable energy installations. Not all of the analyzed variants contributed to reducing the demand for non-renewable primary energy. Only 8 variants out of 25 analyzed allowed to obtain a satisfactory result. The lowest value of the EP coefficient of 13.45 kWN(m2year) was obtained for the 010 variant consisting in the use of a photovoltaic installation with a capacity of 33.78 kWp, which covers 100% ofthe available roof area for a solution based on the use of a glycol-water heat pump as a heat source a low-parameter central heating installation and a flow method of DHW heating, as well as a hygro-controlled mechanical exhaust ventilation system. It has been shown that the use of renewable energy sources (RES) contributes to reducing the demand for non-renewable primary energy.
EN
The paper presents a technical and economic analysis of the power supply for a model industrial facility with the use of the most promising renewable energy sources (RES), supported by a hydrogen energy storage. This scenario was compared with the variants of supplying the facility directly from the grid and from RES without energy storage. A strategy was proposed for powering the plant aimed at maximising self-consumption of self-generated electricity. In this paper the importance of hybrid renewable energy systems (HRES) with hydrogen energy storage in the Polish Power System is pointed out. For the analysed industrial object, the modelling and optimisation of the systems were performed in the HOMER software, in terms of the lowest net present cost. Attention was also paid to the need to compress hydrogen and the associated electricity consumption.
PL
W artykule przedstawiono analizę techniczno-ekonomiczną zasilania modelowego obiektu przemysłowego z wykorzystaniem najbardziej perspektywicznych odnawialnych źródeł energii (OZE), wspomaganych magazynem wodoru. Scenariusz ten porównano z wariantami zasilania obiektu bezpośrednio z sieci oraz z OZE bez układu magazynowania energii. Zaproponowano strategię zasilania obiektu mającą na celu maksymalizację zużycia energii elektrycznej wytworzonej przez OZE na potrzeby własne. W artykule podkreślono znaczenie hybrydowych systemów OZE z wodorowym magazynem energii w Krajowym Systemie Elektroenergetycznym. Dla analizowanego obiektu przemysłowego, z wykorzystaniem oprogramowania HOMER przeprowadzono modelowanie i optymalizację systemów pod kątem najniższego kosztu bieżącego netto. Zwrócono uwagę na konieczność sprężania wodoru i związane z tym zużycie energii elektrycznej.
EN
The need of significant reduction of energy supply to building sector joined with new European Union regulations, known as Green Deal, requires application of energy and exergy efficient solutions of energy production and distribution. One of the feasible options is use of co-generation and tri-generation energy systems in the small scale. The article presents the study on application of natural gas fired tri-generation system based on gas fired micro-turbine. The system consists of natural gas fired micro-turbine and heat exchanger which produces heat for space heating and ventilation and for cooling energy production in single stage absorption water chiller. The system operates whole year providing fixed electricity production - electrical power NEl, and heating/cooling energy production varying depending on building requirements. As a case study small office building of 1632 m2 useable area has been chosen. Energy and exergy models of evaluated system have been presented. It has been found that annual average energy and exergy efficiencies of the system are low - 0,339 and 0,247 respectively. It is due to the limited utilization of enthalpy and exergy of flue gas in heat exchanger.
PL
Konieczność znaczącego ograniczenia potrzeb energetycznych budynków związana z najnowszą strategią Unii Europejskiej znaną jako Zielony Ład, wymaga stosowania efektywnych energetycznie rozwiązań w zakresie produkcji i dystrybucji energii. Jedną z możliwych do realizacji opcji jest wykorzystanie systemów ko-generacyjnych i tri-generacyjnych małej mocy. W artykule przedstawiono studium zastosowania układu tri-generacyjnego małej mocy opartego o mikroturbinę gazową. Układ składa się z mikroturbiny gazowej z wymiennikiem ciepła dostarczającym ciepło do układu ogrzewania i wentylacji budynku oraz absorpcyjnej jednostopniowej wytwornicy wody lodowej. Układ pracuje przez cały rok zapewniając stałą produkcję mocy elektrycznej - NEl, i produkcję mocy cieplnej/chłodniczej zależną od potrzeb budynku. Jako studium przypadku przyjęto mały budynek biurowy o powierzchni użytkowej 1632 m2. Dla potrzeb analizy stworzone zostały modele energetyczny i egzergetyczny układu. Wyniki analizy wykazały niską średnioroczną sprawność energetyczną i egzergetyczną układu - odpowiednio 0,339 i 0,247. Jest to związane z ograniczonym wykorzystaniem entalpii i egzergii spalin przepływających przez wymiennik ciepła.
PL
Z punktu widzenia polityki dekarbonizacji Unii Europejskiej kluczowe staje się szersze wdrażanie odnawialnych źródeł energii i zwiększenie efektywności energetycznej sektora budowlanego. Szczególne znaczenie ma to w przypadku budynków jednorodzinnych, które w Polsce stanowią 40% wszystkich budynków. Wśród nich znajdują się budynki starsze, które w najbliższych latach będą wymagały termomodernizacji. W celu poprawy ich charakterystyki energetycznej można wykorzystać energię solarną, energię gruntu, czy energię powietrza w instalacjach pomp ciepła, kolektorów słonecznych i systemów fotowoltaicznych. W artykule przedstawiono wyniki wielowariantowych analiz przeprowadzonych w programie Audytor OZC 7.0 Pro dla istniejącego budynku jednorodzinnego. Uwzględniono w nich instalacje konwencjonalnych i odnawialnych źródeł energii na potrzeby systemów ogrzewania i ciepłej wody użytkowej z uwzględnieniem dostarczenia energii elektrycznej z instalacji fotowoltaicznej. Przeanalizowano w jakim stopniu poszczególne warianty wpływają na wartości wskaźników rocznego zapotrzebowania na energię końcową i pierwotną oraz jednostkowej wielkości emisji CO2.
EN
From the point of view of the European Union’s decarbonisation policy, the wider implementation of renewable energy sources and increasing the energy efficiency of the construction sector are becoming crucial. This is particularly important in the case of single-family buildings, which in Poland account for 40% of all buildings. Among them there are older buildings that will require thermal modernization in the coming years. In order to improve their energy performance, solar energy, ground energy or air energy can be used in heat pump installations, solar collectors and photovoltaic systems. The publication presents the results of multi-variant analyses carried out in the Audytor OZC 7.0 Pro software for an existing single-family building. They included installations of conventional and renewable energy sources for the needs of heating and hot water systems, including the supply of electricity from a photovoltaic installation. The extent to which individual variants affect the values of indicators of annual demand for final and primary energy as well as the unit volume of CO2 emissions was analysed.
first rewind previous Strona / 3 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.