Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 442

Liczba wyników na stronie
first rewind previous Strona / 23 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  wzmocnienie
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 23 next fast forward last
EN
Microstructural coatings enable large heat fluxes to be exchanged during nucleate boiling at small temperature differences. Such heat exchangers are highly efficient and can be used in various mechanical systems. The production techniques of selected types of microstructures (meshes, micro-fins, and longitudinal fins) are presented in the paper, with the main focus on the comparison of thermal performance of these heat-enhancing coatings during nucleate boiling of distilled water and ethyl alcohol. The comparison was done for the same structure height of ca. 0.90. The results indicate that generally, the highest performance was obtained with the laser-processed surface. The heat flux was even about 2.4 times higher for this type of structure than for the micro-fin surface. A modification to the selected model of boiling heat transfer on microstructural coatings was proposed and verified against the experimental data.
PL
W artykule opisano zasady działania ochrony katodowej oraz jej wpływ na trwałość i koszty naprawy obiektów inżynierskich. Przedstawiono przykłady zastosowania ochrony katodowej w remontowanych konstrukcjach mostowych na świecie i w Polsce w długoletnim okresie eksploatacji.
EN
The prevention of corrosion foci in the reinforcement of reinforced concrete engineering structures is one of the main factors that enable their long and reliable service life. This article describes the principles of cathodic protection as well as its impact on the durability and repair costs of engineering structures. Examples of the application of cathodic protection in repaired bridge structures worldwide and in Poland over a long service life are presented.
EN
This article describes the effects that the unstable foundation of a secondary buttress has had on the historic church. The consideration particularly concerns the walls of the apse on which the analysed buttress „was suspended”. The numerical analysis of the work of the walls of the apse and the piercing vault proved to be identical to the inventory of these damages made in reality. This made it possible to propose and carry out further tests, on the basis of which it was possible to determine the working parameters of the object. As a consequence of the reconnaissance and computational analysis carried out, a repair programme was proposed. This programme was adapted to the historic nature of the building.
PL
W artykule opisano skutki, jakie w przypadku zabytkowego kościoła wywołało niestabilne posadowienie wtórnie dostawionej przypory. Rozważanie dotyczy przede wszystkim ścian absydy, na której analizowana przypora „została zawieszona”. Analiza numeryczna pracy ścian absydy i przekrywającego sklepienia okazała się tożsama z inwentaryzacją tych uszkodzeń sporządzonych w rzeczywistości. Pozwoliło to zaproponować i przeprowadzić dalsze badania, na podstawie których możliwe było określenie parametrów pracy obiektu. W konsekwencji przeprowadzonego rozpoznania i analizy obliczeniowej zaproponowano program naprawy dostosowany do zabytkowego charakteru obiektu.
EN
The article analyses of two selected cases of steel tank failures due to the occurrence of a sudden vacuum in the tank are presented. In one case, hot steam suddenly condensed in an empty industrial wastewater tank, causing a sudden drop in pressure in the tank, so the implosion phenomenon occurred. A similar phenomenon of rapid pressure drop occurred in a steel silo for lime meal due to the collapse of the lime meal seepage above the bottom of the silo. In both cases analyzed, permanent damage occurred to the tanks due to loss of stability of their cylindrical shells. Conclusions from the analyses can be useful in preventing failures of similar structures at the stage of their design and during periodic inspections of their technical condition.
PL
W artykule przedstawiono analizy dwóch wybranych przypadków awarii zbiorników stalowych wskutek wystąpienia w nich gwałtownego podciśnienia. W jednym przypadku w pustym zbiorniku na ścieki przemysłowe doszło do nagłego skroplenia się gorącej pary wodnej, co wywołało gwałtowny spadek ciśnienia w zbiorniku, a w efekcie zjawisko implozji. Podobne zjawisko gwałtownego spadku ciśnienia odnotowano w silosie stalowym na mączkę wapienną z powodu tąpnięcia przesklepienia mączki nad dnem silosu. W obu analizowanych przypadkach wystąpiło trwałe uszkodzenie zbiorników wskutek utraty stateczności ich płaszczy walcowych. Wnioski z analiz mogą być przydatne w zapobieganiu awariom podobnych konstrukcji na etapie ich projektowania oraz podczas okresowych kontroli stanu technicznego.
EN
This paper discusses how to strengthen the head of a certain reinforced concrete column. The disadvantages of using CFRP mats for this purpose are described. Alternative solutions, such as the use of external prestressing and Embedded Through‑Section, are presented. Models of the element were made using non‑linear FEM in Atena software. The load‑bearing capacity was determined both in the as‑is condition and after strengthening using Embedded Through‑Section bars. The effectiveness of the proposed solution was proven computationally.
PL
W artykule zaprezentowano sposób wzmocnienia pewnej głowicy słupa żelbetowego. Opisano wady wykorzystania w tym celu mat CFRP. Przedstawiono rozwiązania alternatywne polegające na wykorzystaniu zewnętrznego sprężenia i prętów wklejanych. Wykonano modele elementu, wykorzystując nieliniową MES w programie Atena. Wyznaczono nośność zarówno w stanie zastanym, jak i po wzmocnieniu z wykorzystaniem prętów wklejonych do betonu. Udowodniono obliczeniowo skuteczność zaproponowanego rozwiązania.
6
Content available remote Naprawy i wzmocnienia konstrukcji murowych. Zszycie rys zbrojeniem
PL
W artykule opisano naprawę muru poprzez zszycie rys za pomocą zbrojenia. Opisano zasady współpracy tego rodzaju wzmocnienia z istniejącym murem, przedstawiono metody analiz obliczeniowych oraz technologię wykonania.
EN
The article describes repairing a wall by stitching the cracks with reinforcement. The principles of cooperation of this type of reinforcement with the existing wall are described, and the methods of computational analysis and the technology of execution are presented.
PL
W artykule opisano sposoby napraw zarysowań występujących w konstrukcjach murowych: zbrojenie murów kamiennych siatkami w spoinach, ankrowanie i wieńce rozproszone, iniekcja rys. O wyborze odpowiedniej metody powinny decydować możliwości techniczne realizacji, poparte szczegółową analizą ekonomiczną opłacalności robót.
EN
The article describes methods of repairing cracks in masonry structures: reinforcement of stone walls with mesh in joints, anchoring and dispersed ring beams, crack injection. The choice of the appropriate method should be determined by the technical possibilities of implementation, supported by a detailed economic analysis of the profitability of the works.
8
Content available remote Naprawy i wzmocnienia konstrukcji murowych. Wzmocnienie powierzchniowe
PL
Artykuł jest kontynuacją cyklu o metodach napraw i wzmocnień konstrukcji murowych. W tej części autor dokładnie opisuje metodę wzmacniania powierzchniowego.
EN
The article is a continuation of the series on methods of repair and strengthening of masonry structures. In this part, the author describes in detail the method of surface strengthening.
9
Content available remote Naprawy i wzmocnienia konstrukcji murowych. Przykłady napraw
PL
Artykuł jest ostatnią częścią cyklu, w którym opisano sposoby napraw zarysowań występujących w konstrukcjach murowych oraz podano przykłady napraw takich uszkodzeń. Różnorodność stosowanych metod i technik naprawczych pokazuje, że wybór skutecznego sposobu naprawy zarysowania wcale nie jest łatwy. O takim wyborze powinny decydować możliwości techniczne realizacji, poparte szczegółową analizą ekonomiczną opłacalności robót. Każde uszkodzenie powinno być rozpatrywane indywidualnie. Przed wyborem metody naprawy należy zawsze określić przyczynę powstania zarysowania, a przyjęty sposób naprawy powinien w pierwszej kolejności eliminować lub przynajmniej minimalizować tę przyczynę. W miarę możliwości przyjęta metoda wzmocnienia lub naprawy powinna być sprawdzana obliczeniowo.
EN
This article is the final part of a series describing methods for epairing cracks in masonry structures and providing examples of such damage. The variety of repair methods and techniques demonstrates that choosing an effective crack repair method is difficult. Such a choice should be determined by the technical feasibility of implementation, supported by a detailed economic analysis of the work’s profitability. Each damage should be considered individually. Before selecting a repair method, the cause of the crack should always be determined, and the adopted repair method should primarily eliminate or at least minimize this cause. Whenever possible, the adopted strengthening or repair method should be verified computationally.
PL
Artykuł rozpoczyna cykl, w którym autor opisuje metody napraw i wzmocnień konstrukcji murowych. Przedstawia zasady współpracy danego wzmocnienia/naprawy z istniejącym murem oraz metody analiz obliczeniowych oraz technologię wykonania.
EN
The article begins a series in which the author describes repair methods and reinforcements of masonry structures. It presents the rules cooperation of a given reinforcement/repair with the existing wall and computational analysis methods and production technology.
EN
For many years, the transparency of glass has been a major feature that has excited architects to search for new applications for this material in architecture. Laminated glass is commonly used for structural elements. This requires a durable bond between at least two glass layers and an interlayer. When the glass is fractured, the interlayer holds the glass fragments together. Introducing reinforcement into the cross-section of glass laminates is a way to improve the load-bearing capacity in the post-failure phase. This paper summarises the main results of the research project "Innovative solutions for point-fixed laminated glass with increased load-bearing capacity" funded by the National Centre for Research and Development (NCBR) under the LIDER XI Programme. The article presents the results of destructive tests on laminated glass panes in three load configurations: in-plane, perpendicular to the plane, and combined loading. An important aspect of the work is the testing of full-scale elements. The results of the research can be applied directly to the safety analysis of glass structures, making them significant in terms of failure prevention.
PL
Praca podsumowuje główne rezultaty projektu badawczego “Innowacyjne rozwiązania dla szkła laminowanego mocowanego punktowo o zwiększonej nośności pokrytycznej”, finansowanego przez Narodowe Centrum Badań i Rozwoju (NCBR), w ramach Programu LIDER XI. Artykuł przedstawia wyniki badań niszczących laminowanych tafli w trzech układach obciążeń: w płaszczyżnie tafli, prostopadle do jej płaszczyzny oraz obciążenie kombinowane. Ważnym elementem pracy są również badania elementów wskali rzeczywistej.Wyniki badań mogą mieć wprost zastosowaniewanalizie bezpieczeństwa konstrukcji wykonanych ze szkła, a zatem są istotne w aspekcie zapobiegania awariom.
EN
This article is focusing on a technical design of superstrate layer using 3x3 unit cells to enhance the antenna gain, operating at the center frequency of 2.50 GHz. In fabrication of the proposed antenna, a microstrip antenna is fed by a 50Ω-SMA 3.50 mm connector, and the superstrate is designed using 9 octagon ring-shaped unit cells, which are integrated to form a meta-surface antenna (MS antenna). A prototype antenna is manufactured on an FR4 substrate material with a relative permittivity (ԑr) of 4.3 and a height of 1.6 mm. The prototype antenna is great matched to achieve |S11| of -31.55 dB, exhibits a gain enhancement of >2.0 dBi and achieves a maximum gain of >6.0 dBi. Additionally, the proposed design has been fabricated to validate |S11|, gain, and radiation patterns as comparing with the simulated results that will be presented. Evidently, the simulated results reasonably align with the experimental findings.
PL
W artykule skupiono się na projekcie technicznym warstwy superstratnej wykorzystującej ogniwa elementarne 3x3 w celu zwiększenia zysku anteny, pracującej na częstotliwości środkowej 2,50 GHz. Podczas produkcji proponowanej anteny antena mikropaskowa jest zasilana przez złącze 50 Ω-SMA 3,50 mm, a superstrata została zaprojektowana przy użyciu 9 ośmiokątnych ogniw elementarnych w kształcie pierścienia, które są zintegrowane, tworząc antenę metapowierzchniową (antena MS). Prototypowa antena jest produkowana na podłożu FR4 o przenikalności względnej (ԑr) wynoszącej 4,3 i wysokości 1,6 mm. Prototypowa antena jest doskonale dopasowana do osiągnięcia |S11| -31,55 dB, wykazuje wzmocnienie wzmocnienia >2,0 dBi i osiąga maksymalne wzmocnienie >6,0 dBi. Ponadto proponowany projekt został opracowany w celu sprawdzenia |S11|, wzmocnienia i wzorców promieniowania w porównaniu z symulowanymi wynikami, które zostaną zaprezentowane. Najwyraźniej symulowane wyniki są w rozsądny sposób zgodne z wynikami eksperymentów.
EN
This work designs, simulates, and fabricates a millimeter-wave antenna array for a 5G base station to support the significant improvements that come with the new 5G technology. The work starts with 1x8 arrays with sizes of 64.21.2 mm² and 55x20.2 mm² for 28 and 38 GHz, respectively. The elements are then increased to 8x8 arrays with dimensions of 64x169 mm² for 28 GHz and 55x161.5 mm² for 38 GHz. The proposed design is further promoted to a 16x8 array antenna with dimensions of 74x255x0.508 mm³. This antenna configuration initially consists of an 8x8 series-fed array operating at 28 GHz and another 8x8 operating at 38 GHz, all implemented on a Rogers/RT 5880 substrate with εr=2.2. At 28 GHz and 38 GHz, the radiation efficiency was measured to be 97.6% and 96.8%, respectively, and the greatest actual gain was 24.7 dBi. Additionally, the antenna array significantly boosts gain. The antenna's performance spans a dual-band millimeter-wave spectrum operating at 28 38 GHz. Specifically, at 28 GHz, 8x8 arrays have a realized gain of 20.33 dBi, and at 38 GHz, the gain is 22.23 dBi. Moreover, for the antenna range, the model displays a symmetrical radiation pattern, and the side lobe level is diminished to -10.2 dB. Two simulation programs, MWSCST2020, and ANSYS HFSS19, are used to simulate these array antennas. The simulation results closely match the actual model performance. Furthermore, the antenna is measured using an Agilent R&S Z67 VNA.
PL
W ramach tej pracy projektuje, symuluje i wytwarza układ anten wykorzystujących fale milimetrowe dla stacji bazowej 5G, aby wspierać znaczące ulepszenia wprowadzone w nowej technologii 5G. Prace rozpoczynają się od układów 1x8 o rozmiarach 64,21,2 mm² i 55x20,2 mm² odpowiednio dla 28 i 38 GHz. Elementy są następnie powiększane do macierzy 8x8 o wymiarach 64x169 mm² dla 28 GHz i 55x161,5 mm² dla 38 GHz. Proponowany projekt jest dalej promowany do anteny szeregowej 16x8 o wymiarach 74x255x0,508 mm³. Ta konfiguracja anteny początkowo składa się z układu zasilanego szeregowo 8x8 pracującego przy 28 GHz i kolejnego 8x8 pracującego przy 38 GHz, wszystkie zaimplementowane na podłożu Rogers/RT 5880 z εr=2,2. Dla częstotliwości 28 GHz i 38 GHz zmierzona efektywność promieniowania wyniosła odpowiednio 97,6% i 96,8%, a największe rzeczywiste wzmocnienie wyniosło 24,7 dBi. Dodatkowo układ anten znacznie zwiększa zysk. Wydajność anteny obejmuje dwuzakresowe widmo fal milimetrowych w paśmie 28–38 GHz. W szczególności przy 28 GHz macierze 8x8 mają zrealizowany zysk na poziomie 20,33 dBi, a przy 38 GHz zysk wynosi 22,23 dBi. Ponadto dla zasięgu anteny model wykazuje symetryczną charakterystykę promieniowania, a poziom listka bocznego jest obniżony do -10,2 dB. Do symulacji tych anten szeregowych służą dwa programy symulacyjne, MWSCST2020 i ANSYS HFSS19. Wyniki symulacji są ściśle zgodne z rzeczywistą wydajnością modelu. Ponadto antena jest mierzona za pomocą Agilent R&S Z67 VNA.
PL
Przedmiotem analizy są strunobetonowe dźwigary dachowe systemu P70 (SBn-I-65/15). Produkowano je w wersji umożliwiającej wzmocnienie nadbetonem ułożonym między prefabrykowanymi płytami dachowymi, dzięki czemu uzyskiwano pełną projektowaną nośność. W trakcie oględzin analizowanego obiektu stwierdzono, iż nadbeton taki wykonano, jednak nie w obrębie świetlików kalenicowych, gdzie wykonano wyłącznie nadbeton spadkowy. Z tego względu odcinek pod świetlikami jest krytyczny z punktu widzenia bezpieczeństwa konstrukcji. Brak nadbetonu jest również powodem znaczących ugięć dźwigarów. W pracy przedstawiono wyniki oceny stanu technicznego, badań, pomiarów geodezyjnych ugięć i sprawdzających obliczeń statyczno-wytrzymałościowych oraz sposób wzmocnienia dźwigarów, umożliwiający jego realizację na czynnym obiekcie.
EN
The subject of the analysis is prestressed concrete roof girders of the P70 system (SBn-I-65/15). They were produced in a version that allowed reinforcement with superconcrete laid between prefabricated roof slabs, thus achieving the full design load capacity. During the visual inspection of the analyzed facility, it was found that such overcrete was made, but not within the ridge skylights, where only sloping overcrete was made. Therefore, the section under the skylights is critical from the point of view of structural safety. The lack of overconcrete is also the reason for the significant deflection of the girders. This paper presents the results of a technical condition assessment, tests, geodetic measurements of deflections and verifying static-strength calculations, as well as the method of strengthening the girders, allowing it to be carried out on an active building.
PL
W latach 70. ubiegłego wieku, w Polsce, w okresie dużego rozwoju przemysłu, powstało szereg obiektów inżynierskich. Do grupy tych obiektów należały opisane w artykule stalowe wieże kominowe, stanowiące konstrukcję wsporczą dla umieszczonych wewnątrz – przewodów kominowych, wykonanych z rur poliestrowych. Obecnie przedsiębiorstwa, na terenie których zlokalizowane są tego typu obiekty, stoją przed decyzją dotyczącą ewentualnej modernizacji lub rozbiórki. Modernizacja konstrukcji poprzedzona jest ekspertyzą stanu technicznego, pomiarami geodezyjnymi i analizą nośności w oparciu o obowiązujące normy. Na ich podstawie dla opisywanych wież określono konieczne do wykonania prace wzmacniające. W artykule zwrócono również uwagę na konieczność uwzględnienia w analizach obliczeniowych obok obciążeń środowiskowych, technologicznych również rzeczywistych imperfekcji geometrycznych.
EN
In the 1970s in Poland, during the period of great industrial development, a number of engineering facilities were built. The group of these objects included the steel chimney towers described in the article, which are supporting structures for the chimney flues made of polyester pipes placed inside. Currently, companies in which such facilities are located are faced with decisions regarding possible modernization or demolition. The modernization of the structure is preceded by an expert opinion on the technical condition, geodetic measurements and load-bearing analysis based on applicable standards. On their basis, the necessary strengthening works were determined for the described towers. The paper also drew attention to the need to take into account, in addition to environmental and technological loads, actual geometric imperfections in computational analyses.
PL
Praca dotyczy zagadnień związanych ze wzmocnieniem dachów dwóch budynków przemysłowych o konstrukcji drewnianej, uszkodzonych na skutek działania wiatru. Dachy budynków o konstrukcji tradycyjnej, wykonanych na początku XX wieku zostały uszkodzone na skutek działania porywistego wiatru we wrześniu 2020 r. W pracy opisano konstrukcję budynków, zakres zniszczeń oraz koncepcję naprawy i wzmocnienia.
EN
The paper deals with issues related to the reinforcement of the roofs of two industrial buildings with a timber structure, damaged by wind. The roofs of buildings of traditional construction, made at the beginning of the 20th century, were damaged by winds in September 2020. The work describes the structure of the buildings, the extent of damage and the concept of repair and strengthening.
PL
W pracy przedstawiono problematykę związaną z nieodpowiednim wykonaniem dawnej rozbudowy budynku użyteczności publicznej pełniącego częściowo funkcję muzeum. Przedstawiono stan istniejący wraz z zakresem powstałych uszkodzeń stanowiących zagrożenie w dalszej eksploatacji obiektu. Na podstawie przeprowadzonych odkrywek i badań w oparciu o analizę obliczeniową podano przyczynę ich powstania. Finalnie przedstawiono program naprawczy, który po zrealizowaniu umożliwił dalsze użytkowanie obiektu w bezpiecznym zakresie.
EN
The paper presents the problems associated with the inadequate execution of the former extension of a public building serving partially as a museum. The existing condition is presented, along with the extent of the damages that have occurred, posing a threat in the further operation of the building. On the basis of the excavations and investigations carried out as well as computational analysis, the cause of their occurrence is given. Finally, a repair program was presented, which, when implemented, enabled further use of the object in a safe range.
PL
Artykuł dotyczy naprawy i wzmocnienia żelbetowych słupów podpierających konstrukcję nośną pomostów komunikacyjnych łączących komory fermentacyjne we Wrocławskiej Oczyszczalni Ścieków. W wyniku sprawdzenia stanu technicznego słupów podporowych pod kątem bezpieczeństwa dalszego użytkowania stwierdzono, że słupy żelbetowe mają liczne zarysowania poziome prostopadłe do osi podestu. Przeprowadzona analiza wykazała błędy projektowe i wykonawcze na etapie wytwarzania konstrukcji i podczas jej realizacji. Wśród nich można wyróżnić: niewłaściwe zbrojenie, mikrorysy i naprężenia skurczowe, zbyt dużą otulinę zbrojenia oraz brak podparcia belek pomostu na łożyskach powiązanych z konstrukcją zwieńczającą poszczególne komory fermentacyjne. W artykule autorzy przedstawili wytyczne prac remontowych betonu oraz zalecenia dotyczące wzmocnienia uszkodzonych słupów oraz dodatkowego przegubowego podparcia pomostu komunikacyjnego.
EN
The paper deals with the strengthening of reinforced concrete columns supporting the load-bearing structure of the communication platforms connecting fermentation chambers in the Wrocław Sewage Treatment Plant. As a result of the check of the technical condition of the supporting columns in terms of safety for future use, it was found that the reinforced concrete columns had numerous horizontal cracks perpendicular to the platform axis. The analysis carried out revealed design and construction errors during the design and construction phases. These include: inappropriate reinforcement, microcracking, and shrinkage stresses, excessive reinforcement cover, and the lack of support for the beams of the platform on bearings associated with the structure topping individual fermentation chambers. In the paper, the authors presented guidelines for concrete repair work and recommendations for reinforcing damaged columns and providing additional pinned support for the communication platform.
EN
The paper presents test results of eccentrically compressed concrete elements strengthened with PBO-FRCM. FRCM (Fabric Reinforced Cementitious Matrix) composites consist of high-strength PBO (p-Phenylene Benzobis Oxazole) fibers embedded in mineral matrix, which gives greater resistance to elevated temperatures compared to popular FRP (Fiber Reinforced Polymer) composites with a polymer matrix. The tests were conducted on elements made of normal-strength concrete with a compressive strength of approximately 45 MPa, which is typical for currently constructed reinforced concrete structures. The strengthening of the tested elements consisted of one, two, or three layers of PBO mesh with an overlap length of 1/4 of the sample circumference. The samples were subjected to both axial and eccentric compression tests.This research provides the foundation for developing a model to calculate the interactive capacity (axial force-bending moment) of reinforced concrete sections, taking into account the external PBO-FRCM composite wrapping.
PL
W artykule przedstawiono wyniki badań mimośrodowo ściskanych elementów betonowych wzmocnionych kompozytami PBO-FRCM. Kompozyty FRCM (ang. Fabric Reinforced Cementitious Matrix – matryca cementowa zbrojona tkaniną) składają się z wysokowytrzymałych włókien PBO (p-Phenylene Benzobis Oxazole) zatopionych w matrycy mineralnej, przez co charakteryzują się większą odpornością na podwyższone temperatury w porównaniu z popularnymi kompozytami FRP (ang. Fiber Reinforced Polymer – polimer zbrojony włóknami) o matrycy polimerowej. Badania przeprowadzono na elementach wykonanych z betonu zwykłego o wytrzymałości na ściskanie ok. 45 MPa, typowego w przypadku obecnie wykonywanych konstrukcji żelbetowych. Wzmocnienie badanych elementów stanowiły jedna, dwie bądź trzy warstwy siatki PBO z zakładem o długości 1/4 obwodu próbki. Próbki poddawano zarówno próbom ściskania osiowego, jak i mimośrodowego. Przedstawione badania są punktem wyjścia do sformułowania modelu, służącego do wyznaczania interakcyjnej nośności (siła osiowa – moment zginający) przekrojów żelbetowych, z uwzględnieniem zewnętrznego uzwojenia kompozytowego PBO-FRCM.
EN
The aim of the presented research was to determine the effect of reinforcement on the behavior of compressed masonry arches. Three research serieswere tested: unreinforced models and reinforced with a reinforced concrete rib and the FRCM (Fiber Reinforced Cementitious Matrix) system. In each series, two models were tested. The research was conducted at the Faculty of Civil Engineering of the Silesian University of Technology.
PL
Celem prezentowanych badań było określenie wpływu wzmocnienia na zachowanie ściskanych łuków murowanych. Przeprowadzono badania trzech serii modeli: niewzmocnionych oraz wzmocnionych żebrem żelbetowym i systemem FRCM (ang. Fiber Reinforced Cementitious Matrix). W każdej serii badano dwa modele. Badania realizowano na Wydziale Budownictwa Politechniki Śląskiej.
first rewind previous Strona / 23 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.