EN
This research aimed to investigate the impact on performance and environmental factors of newly developed blended refrigerants XP10-Opteon and Solstice® N13 from the olefins group. With a focus on mobile air conditioning (AC) systems, the necessity to replace high global warming potential (HGWP) R134a (1400) refrigerant has become prominent over the past decades. It was crucial to find a more suitable refrigerant with low global warming potential (LGWP), such as HFO-blend R513a (573) or R450a (547), especially for industrial or commercial applications within the medium temperature range of 25°C to -10°C. This particular research entailed utilizing HFC-HFO blend refrigerants for automotive air conditioning applications. The experimental setup employed a 0.50HP hermetic reciprocating compressor and a copper tube-type condenser. The temperature range for testing was maintained between 30°C and 60°C. A more pronounced reduction of 14-24.6% in electricity usage because of less power consumption enhanced the value of COP. The results revealed noteworthy findings in comparison to R134a; the average coefficient of performance (COP) for R513a exhibited almost the same performance coefficient with a little bit reduction factor of approximately 13%, whereas R450a showed results better than R134a with 8% enhancement at the same operating conditions. Additionally, the mass flow rate for R513a increased by 14-16%. Most importantly, R513a showed a substantial global warming potential (GWP) reduction by approximately 56-57% compared to the conventional refrigerant R134a.
PL
Artykuł przedstawia wybrane doświadczenia z wykorzystania pompy ciepła do ogrzewania budynku jednorodzinnego pierwotnie ogrzewanego kotłem węglowym. Omówiono zagadnienia związane z doświadczeniami po stronie zasilania elektrycznego pompy ciepła oraz zagrożeń korozją związanych z jakością wykorzystywanej wody. Wyznaczono faktycznie osiągany COP (ang. Coefficient of Performance) pompy ciepła poprzez odniesienie zużytej energii elektrycznej do energii cieplnej wcześniej dostarczonej ze spalania węgla. Przedstawiono też ogólne uwagi dotyczące upowszechnienia pomp ciepła w ogrzewnictwie.
EN
The article presents the selected lessons learned from the use of a heat pump for heating the single-family house previously heated by the coal-fired boiler. The article highlights the obtained experience as regards the heat pump power supply and corrosion risks due to the quality of water used. The actual Coefficient of Performance (COP) of the heat pump is determined by referring the electrical energy used to heat previously supplied from coal combustion. Moreover, general remarks relating to the enhancement of more popular deployment of heat pumps in the district heating sector are discussed.
3
Content available remote Chłodzenie obiektów szpitalnych z wykorzystaniem odnawialnych źródeł energii
PL
W artykule wykonano analizę efektywności istniejącego centralnego systemu chłodzenia zw. Źródłem ciepła i chłodu” zainstalowanego w Samodzielnym Publicznym Wojewódzkim Szpitalu Zespolonym w Szczecinie. Została także rozważona możliwość modernizacji systemu chłodzenia, której celem jest maksymalizacja stopnia wykorzystania odnawialnego źródła energii (gruntowego wymiennika ciepła) i w efekcie obniżenie kosztu ekologicznego i ekonomicznego eksploatacji instalacji chłodzenia obiektu szpitalnego. Modernizacja systemu polega na dodaniu miejscowych źródeł chłodu do zasilania niektórych odbiorów oraz przebudowie odbiorów w celu maksymalizacji wykorzystania chłodzenia „pasywnego” (odbioru ciepła przez dolne źródło ciepła- grunt). W rezultacie zaproponowanej modernizacji efektywność energetyczna układu (COP) osiągnie wartość 3,79, a jego udział chłodzenia pasywnego w ogólnej produkcji chłodu wyniesie 0,44. Natomiast efektywność energetyczna analizowanego wariantu z uwzględnieniem współpracy ze źródłem pasywnego chłodu wyniesie COP=9,1.
EN
The article presents the possibilities of analyzing the efficiency of the existing central cooling system of the facility “Źródło ciepła i chłodu” (Heat and Cooling Source) located in the Independent Public Provincial Hospital in Szczecin. A possible modernization was also considered, aimed at maximizing the use of renewable energy (ground heat exchanger), as a result of which the ecological and economic cost of operating the cooling installation of the hospital facility under study was reduced. The modernization will be carried out by adding local cooling sources for the receivers requiring it and by rebuilding the receivers in order to maximize the use of “passive” cooling (receipt of thermal energy by the lower heat source). The obtained economic effect allows determining the efficiency of the proposed solution (COP) at the level of 3.79, and its share in the production of cooling at 0.44. In the tested variant, the efficiency (COP) taking into account cooperation with the passive cooling source was 9.1.
PL
Artykuł przedstawia analizę porównawczą dwóch rozwiązań chłodniczych średniej skali: instalacji transkrytycznej CO2 oraz instalacji zasilanej propanem R290. Pod względem całkowitych kosztów posiadania (TCO) w horyzoncie 10-letnim oceniono: wpływ efektywności energetycznej (COP, SEPR), kosztów inwestycyjnych (CAPEX) oraz operacyjnych (OPEX). Uwzględniono aspekty związane z serwisem i konserwacją, a także aspekty środowiskowe (GWP, emisje pośrednie CO2). Układy z R290 są efektywniejsze i tańsze, a systemy CO2 konkurencyjne w dużych instalacjach przemysłowych (zwłaszcza przy odzysku ciepła).
EN
The article compares two medium-scale refrigeration systems: a transcritical CO2 installation and a propane-based (R290) system. The study considered the mainstream economic criteria, such as: COP and SEPR (energy efficiency), CAPEX (investment), OPEX (operation) and TCO over 10 years. Environmental aspects (GWP, indirect CO2 emissions) and service requirements were also taken into account. The results demonstrate that R290 systems exhibit higher efficiency and lower total costs, while CO2 installations remain a competitive option for large industrial facilities especially when heat recovery is applied.
PL
W artykule przedstawiono możliwości analizy efektywności istniejącego centralnego systemu chłodzenia obiektu „Źródło Ciepła i Chłodu” znajdującego się w Samodzielnym Publicznym Wojewódzkim Szpitalu Zespolonym w Szczecinie. Została także rozważona możliwa do wykonania modernizacja mająca na celu maksymalizację wykorzystania odnawialnej energii (gruntowego wymiennika ciepła), w efekcie obniżenie kosztu ekologicznego i ekonomicznego eksploatacji instalacji chłodniczej badanego obiektu szpitalnego. Modernizacja zostanie przeprowadzona przez dodanie miejscowych źródeł chłodu dla odbiorów tego wymagających oraz przebudowę odbiorów celem maksymalizacji wykorzystania „pasywnego” chłodu (odbioru ciepła przez dolne źródło ciepła). Uzyskany efekt ekonomiczny pozwala na określenie efektywności zaproponowanego rozwiązania (COP) na poziomie 3,79, a jego udział w produkcji chłodu na 0,44. W badanym wariancie efektywność (COP) uwzględniająca współpracę ze źródłem pasywnego chłodu wynosiła 9,1.
EN
The article presents the possibilities of analyzing the efficiency of the existing central cooling system of the facility "Źródło Ciepła i Chłodu" (Heat and Cooling Source) located in the Independent Public Provincial Hospital in Szczecin. A possible modernization was also considered, aimed at maximizing the use of renewable energy (ground heat exchanger), as a result of which the ecological and economic cost of operating the cooling installation of the hospital facility under study was reduced. The modernization will be carried out by adding local cooling sources for the receivers requiring it and by rebuilding the receivers in order to maximize the use of "passive" cooling (receipt of thermal energy by the lower heat source). The obtained economic effect allows determining the efficiency of the proposed solution (COP) at the level of 3.79, and its share in the production of cooling at 0.44. In the tested variant, the efficiency (COP) taking into account cooperation with the passive cooling source was 9.1.
PL
Przedstawiono wyniki badań eksploatacyjnych pompy ciepła typu powietrze-woda w wersji monoblok z naturalnym czynnikiem chłodniczym R290. W pompie ciepła zastosowano sprężarkę inwerterową. Omówiono wpływ temperatury i zmiennego strumienia masy wody w obiegu parownika oraz zmiennego obciążenia cieplnego skraplacza na dobór nastaw elektronicznego zaworu rozprężnego i moc chłodniczą pompy ciepła. Badania wykonano dla pompy ciepła w trybie chłodzenia pomieszczenia hali laboratoryjnej. W czasie 60-minutowych cykli pomiarowych dla pełnego obciążenia sprężarka zużywała średnio 2700 Wh energii elektrycznej, a zapotrzebowanie wentylatorów i pompy obiegowej wynosiło średnio 900 Wh. Pompa ciepła wytwarzała energię chłodniczą na poziomie 8000 Wh.
EN
Operational tests of an air-to-water heat pump in a monoblock version with the natural refrigerant R290 (propane) were presented. The effect of temp. and variable mass flow of water in the evaporator circuit and variable heat load of the condenser on the selection of electronic expansion valve settings and the cooling power of the heat pump was discussed. Tests were carried out for the heat pump in the cooling mode of a laboratory room, in 60-minute measurement cycles. For the full heat load, an av. COP of 2.20 was obtained for the entire system.
EN
Energy scarcity in the world and the pollutants resulting from excessive use of energy lead to an increase in global warming. There is a need to search for sustainable alternatives that use less energy to reduce environmental problems as well as alternatives to the use of Freon, which is harmful to the environment, one of the most dangerous pollutants, and increases the ozone hole. The current research aims to investigate the performance of thermoelectric refrigerators with different operating conditions. A portable thermoelectric refrigerator was developed for those living in remote areas of Egypt off the electrical grid (e.g., deserts). The designed refrigerator is based on the Peltier effect using Peltier units. The refrigerator is designed, manufactured, and experimentally tested. Several variables were studied in fast cooling systems for different conditions to minimize time, decrease the cooling temperature, and increase the coefficient of performance (COP) by the response surface methodology (RSM) model. The results reveal that the obtained maximum COP was 77.3%, at 4 V and 1.006 with a difference in cooling temperature (∆T) of 8°C. The highest ∆T was 26.4°C at 10 V, 9.149 A, 91.49 W and COP 11.2%. The optimum condition was cooling temperature 12.7°C, COP 51.4% at 4 V, 3.445 A by using 4 Peltier, according to Response surface methodology (RSM) includes optimization procedures for the settings of factorial variables by design expert 13, such that maximum ∆T was 20.3°C and maximum COP 49.576% with 4 volts, 4 no. of Peltier and current 3.601 A in the value range. The results reveal that the obtained determination coefficient for ∆T and the COP adjusted R2 and R3 values 0.9286 and 0.9603 respectively.
PL
Niedobór energii na świecie i zanieczyszczenia wynikające z nadmiernego zużycia energii prowadzą do wzrostu globalnego ocieplenia. Istnieje potrzeba poszukiwania zrównoważonych alternatyw, które zużywają mniej energii w celu zmniejszenia problemów środowiskowych, a także alternatyw dla stosowania freonu, który jest szkodliwy dla środowiska, jednym z najniebezpieczniejszych zanieczyszczeń i zwiększa dziurę ozonową. Obecne badania mają na celu zbadanie wydajności lodówek termoelektrycznych w różnych warunkach pracy. Przenośna lodówka termoelektryczna została opracowana dla osób mieszkających w odległych obszarach Egiptu poza siecią elektryczną (np. pustynie). Zaprojektowana lodówka opiera się na efekcie Peltiera z wykorzystaniem jednostek Peltiera. Lodówka została zaprojektowana, wyprodukowana i przetestowana eksperymentalnie. Zbadano kilka zmiennych w systemach szybkiego chłodzenia dla różnych warunków, aby zminimalizować czas, obniżyć temperaturę chłodzenia i zwiększyć współczynnik wydajności (COP) za pomocą metodologii powierzchni odpowiedzi (RSM). Wyniki pokazują, że uzyskany maksymalny współczynnik COP wynosił 77,3% przy 4 V i 1,006 przy różnicy w temperaturze chłodzenia (ΔT) wynoszącej 8°C. Najwyższa ΔT wynosiła 26,4°C przy 10 V, 9,149 A, 91,49 W i COP 11,2%. Optymalnym warunkiem była temperatura chłodzenia 12,7°C, COP 51,4% przy 4 V, 3,445 A przy użyciu 4 Peltierów, zgodnie z metodologią powierzchni odpowiedzi (RSM) obejmującą procedury optymalizacji ustawień zmiennych czynnikowych przez eksperta ds. projektowania 13, tak że maksymalna ΔT wynosiła 20,3°C i maksymalny COP 49,576% przy 4 V, 4 nr Peltiera i prądzie 3,601 A w zakresie wartości. Wyniki pokazują, że uzyskany współczynnik determinacji dla ΔT i COP skorygowane wartości R2 i R3 odpowiednio 0,9286 i 0,9603.
EN
Synthetic refrigerants are being phased out gradually in accordance with international environmental protection protocols because of global warming and ozone layer depletion. Adopting R290/R600 refrigerant, an environmentally friendly refrigerant, to replace R134a, a high global warming potential refrigerant, provides one of the solutions. In this study, exergy analysis of R134a and TiO2 suspended with lubricant and R290/R600 with a composition of 60% R290 and 40% R600 (60:40) was investigated in vapour compression system (VCRS) using R290/R600 in TiO2 nanomixture lubricant and compared with R134a and R290/R600 in pure lubricant. At the inlets and outlets, the main components of the VCRS are connected to temperature and pressure sensors to measure the inlet and outlet temperatures and pressures. The results obtained were used to analyses the exergy losses at various VCrR components (compressor, condenser, evaporator, expansion valve) were investigated to determine the refrigerator’s total exergy destruction (Exdest.Total) and efficiency (ηex). The Exdest.Total of R290/R600 in pure lubricant and R290/R600 TiO2 nanomixture lubricant was reduced by 26.9% and 42.3%, respectively, and system ηex increased by 27.7% and 38.9% respectively when compared to R134a in the system. Hence, TiO2 suspended with R290/R600 is potential a substitute for R134a.
EN
The paper presents the design of a two-stage subcritical compressor heat pump operating in an air-to-water system and running on environmentally friendly refrigerants. The pump is dedicated to buildings where there is a high-temperature central heating system and wall-mounted radiators are used as heat receivers. The first stage of the unit was supplied with R290 refrigerant and the second stage with R1234 ze(E) refrigerant. The nominal heating power of the unit is 10kW for a lower source temperature in the range -20°C÷10°C. The unit's refrigeration system was designed and simulation tests were carried out to determine the unit's operating parameters for the lower source temperature in the range -20°C÷10°C, the condensation temperature of the stage I refrigerant for values: 20°C, 25°C, 30°C and the condensation temperature of the stage II refrigerant in the range 30°C÷60°C. The value of the coefficient of performance (COP) was determined in relation to the heating power generated in stages I and II to the electricity consumed, which value, depending on the operating parameters, ranges from 2.55 to 5.6. The value of the COP related to the heating power received from the stage II condenser to the total power consumed by the stage I and II compressor, depending on the operating parameters, ranges from 1.5 to 2.9. It was found that by using a stepless adjustment of the volumetric efficiency of the stage I and II compressor, it is possible to match the heating power of stage I to the cooling power of stage II and thus increase the COP value by 50%.
EN
In order to further increase the energy efficiency of the experimental building, field experiments were conducted to maintain the proper thermal regime of its premises when using a heat pump heating system. The paper presents the results of experimental studies of the operating parameters of the heat pump heat supply system of an energy-efficient building of the Institute of Engineering Thermophysics of the National Academy of Sciences of Ukraine. The given analysis of the energy efficiency of the operation of the "soil-water" type heat pump in the nominal mode with the maximum load showed a high value of the energy conversion coefficient.
PL
Technologia pomp ciepła może być wykorzystywana nie tylko do ogrzewania domów jedno- czy też wielorodzinnych, ale coraz częściej znajduje swoje ekonomiczne zastosowanie także w przemyśle. Z powodzeniem może być stosowana w ogrzewaniu i chłodzeniu podczas procesu zagęszczania produktów mlecznych oraz do pasteryzacji i zagęszczania soków i koncentratów spożywczych w urządzeniach zwanych wyparkami. W artykule przeprowadzono analizę termodynamiczną i ekonomiczną zastosowania obiegu wyparki w zakładzie mleczarskim zasilanej pompą ciepła.
EN
Photovoltaics powered DC air conditioners have a lot of potential for energy-efficient cooling while also being very cost-effective. They have the potential to significantly cut energy consumption in the construction sector, which is critical in meeting the larger goal of lowering greenhouse gas emissions. In this paper, the performance of a split-unit DC air conditioner is evaluated. The DC air conditioner, which operates directly on 48 VDC and includes a variable-speed compressor, has lately become accessible on the international market. This study discusses a number of topics, including energy use, investigation of the coefficient of performance (COP) and power quality concerns. Solar power is the primary energy source, as it is a renewable resource that is both readily available and beneficial to future generations. The output of the DC air conditioner can be alternatively changed according to the size of the room by altering the speed of the Brushless DC motor in this work.
PL
Klimatyzatory DC zasilane fotowoltaiką mają duży potencjał w zakresie energooszczędnego chłodzenia, a jednocześnie są bardzo opłacalne. Mają potencjał, aby znacząco obniżyć zużycie energii w sektorze budowlanym, co ma kluczowe znaczenie dla osiągnięcia większego celu, jakim jest obniżenie emisji gazów cieplarnianych. W tym artykule oceniana jest wydajność klimatyzatora DC typu split. Klimatyzator DC, który działa bezpośrednio na 48 VDC i zawiera sprężarkę o zmiennej prędkości, stał się ostatnio dostępny na rynku międzynarodowym. W niniejszym opracowaniu omówiono szereg tematów, w tym zużycie energii, badanie współczynnika wydajności (COP) i problemy z jakością energii. Energia słoneczna jest podstawowym źródłem energii, ponieważ jest zasobem odnawialnym, który jest zarówno łatwo dostępny, jak i korzystny dla przyszłych pokoleń. Moc klimatyzatora DC można alternatywnie zmienić w zależności od wielkości pomieszczenia, zmieniając prędkość bezszczotkowego silnika prądu stałego w tej pracy.
PL
Artykuł przedstawia wyniki pomiarów temperatury na wybranych głębokościach wzdłuż pionowych gruntowych wymienników ciepła przy różnej wydajności dolnego źródła w przypadku systemu grzewczego z wykorzystaniem sprężarkowej pompy ciepła. W eksperymencie analizowano wybrane przypadki pracy systemu grzewczego z pompą ciepła - z jednym, dwoma oraz trzema pionowymi gruntowymi wymiennikami, stanowiącymi dolne źródło ciepła. Celem pracy było badanie zachowania się gruntu w przypadku niedoszacowania, dopasowania oraz przewymiarowania dolnego źródła ciepła.
EN
The article presents the results of temperature measurements at selected depths along vertical ground heat exchangers with different efficiency of the lower heat source for a heating system based on a compressor heat pump. The experiment analyzed selected cases of operation of a heating system with a heat pump - with one, two and three vertical ground heat exchangers. The aim of the study was to investigate the behavior of the soil in the event of underestimation, adjustment and oversizing of the lower heat source.
EN
The description of original technical decision of using heat pump for heating part of administrating building is described. The hydraulic connection scheme has been developed and selection of heat devices was made for it. The energy efficiency for using heat pump in heating season is analyzed. Based on the obtained experimental data, the coefficient of performance of the heat pump was calculated for the above mode of operation of the heat supply system. With such indicators, a significant saving of thermal energy is achieved in comparison with the use of a centralized heat supply system.
EN
Solid-state thermoelectric elements, such as thermoelectric (TE) modules, can be used as cooling devices. Small-sized TE modules, characterized by: lack of moving parts, no required refrigerants application as well as variable possible installation and operation positions, allow, in several specified cases, achieving the advantage in cooling process over the conventional refrigeration devices. This paper presents the results of the preliminary numerical determination of energetic efficiency of thermoelectric cooling system, applied for cooling a small-scale experimental room. The heat exchangers used in the cooling system consisted of heat sinks and radiators installed on the both sides of the TE module. The numerical assessment included in this paper, based on a 3D model reflecting the experimental room and thermoelectric cooling system, allowed determining the relation between TE module power supply characteristics and cooling effects, as well as time-related temperature distribution inside the modeled experimental room. The commercial modeling software FLUENT, ANSYS 12.0 by ANSYS Inc. was applied in numerical calculations. The results of the performed laboratory studies were used as a basis for model development, required input data, initial and boundary conditions. The results of laboratory tests showed the influence of amperage of power supply on the efficiency of cooling characteristics, as well as distribution of air temperature inside the experimental room. Calibration and validation of the developed model was also based on the results of laboratory experiment. The obtained results of numerical calculations showed the influence of amperage of power supply on efficiency of cooling characteristics as well as distribution of air temperature inside the experimental room.
PL
W artykule przedstawiono wyniki badań parametrów termodynamicznych w celu zwiększenia efektywności energetycznej sprężarkowej powietrznej pompy ciepła o mocy 14 kW. Publikacja zawiera: wprowadzenie, opis rynku pomp ciepła w Polsce oraz zakres wykonanych badań własnych oraz szczegółowo zawiera opis opracowanego modelu matematycznego z wykorzystaniem teorii i planowania eksperymentu.
EN
The article presents the results of research on thermodynamic parameters in order to increase the energy efficiency of a 14 kW air compressor heat pump. The publication includes: an introduction, a description of the heat pump market in Poland and the scope of own research, and includes a detailed description of the mathematical model developed using the theory and experiment planning.
PL
W pracy przedstawiono i uzasadniono celowość stworzenia domu zero-energetycznego skupiającego się na odnawialnych źródłach energii w postaci pompy ciepła i instalacji fotowoltaicznej. Na potrzeby pracy pozyskano rzeczywiste wyniki z pracy pompy ciepła, porównano je z warunkami atmosferycznymi takimi jak: panująca temperatura, wilgotność i nasłonecznienie oraz dobrano wielkość instalacji fotowoltaicznej pozwalającej na całkowite zaspokojenie potrzeb energetycznych budynku. Stworzono również program pozwalający dobrać odpowiednią moc pompy w zależności od danych jakie inwestor bądź firma dobierająca posiada Na podstawie tych danych wykazano ekonomiczną słuszność inwestycji tego rozwiązania.
EN
The paper presents and justifies the desirability of creating a zero-energy house focusing on renewable energy sources in the form of a heat pump and a photovoltaic installation. For the purposes of the study, actual results of a heat pump operation were obtained and compared with atmospheric conditions such as: temperature, humidity, and insolation. The size of the photovoltaic installation was selected, allowing the building to fully meet its energy needs. Furthermore, a program was created that allows people to select the appropriate pump power depending on the data provided by the investor or the selection company. On the basis of these data, the economic viability of the investment of this solution has been demonstrated.
EN
The paper presents the analysis of modern nuclear energy development possibilities in Poland, which is considered as an ecological energy source. As the demand for electrical energy is constantly growing the use of such energy sources in one of the ways to meet the requirements of the Paris Agreement, adopted at COP (Conference of Parties) 21, 2015. The agreement obliges the countries around the world to develop a low carbon dioxide emission economy in order to stop the global temperature rise at 2°C and preferably at 1.5°C.
PL
Artykuł przedstawia wyniki analizy możliwości rozwoju współczesnej energetyki jądrowej w Polsce, zaliczanej do ekologicznych źródeł energii. Wykorzystanie takich źródeł do produkcji energii elektrycznej, której zapotrzebowanie stale rośnie, jest jednym ze sposobów na spełnienie postanowień porozumienia paryskiego, przyjętego na COP 21 w 2015 r. Umowa zobowiązuje państwa na całym świecie do opracowania niskiego poziomu emisji dwutlenku węgla, aby wzrost temperatury na ziemi nie przekraczał 20 C, a najlepiej 1,50 C.
PL
W artykule porównano wartości sezonowego współczynnika efektywności grzewczej wybranych pomp ciepła, określone na podstawie normy PN-EN 14825, wytycznych VDI 4650 oraz danych szacunkowych zawartych w rozporządzeniu w sprawie metodologii wyznaczania charakterystyki energetycznej budynku. W ramach przeprowadzonej analizy wskazano na różnice w uzyskanych wynikach oraz przyczyny ich występowania. Wykorzystane metody różnią się od siebie zarówno sposobem, jak i zakresem uwzględnienia poszczególnych czynników mających wpływ na wartość sCOP. Pomimo że żadna z porównywanych metod nie uwzględnia wszystkich czynników związanych z eksploatacją pomp ciepła, podkreślono, że pozwalają one na istotną poprawę jakości analiz energetycznych w stosunku do wykorzystania danych szacunkowych.
EN
The paper presents comparison of values of seasonal coefficient of performance of selected heat pumps, determined on the basis of PN-EN 14825, VDI 4650 guidelines and estimated data provided in the regulation on the methodology for determining the energy performance of a building. In the analysis, the differences in the obtained results an well as the causes for their occurrence were indicated. The methods used differ in both the way and scope of taking into account various factors affecting the sCOP value. Although none of the compared methods takes into account all of the factors related to the operation of heat pumps, it was emphasized that they allow a significant improvement in the quality of energy analyses compared to the use of estimated data.