Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 67

Liczba wyników na stronie
first rewind previous Strona / 4 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 4 next fast forward last
EN
This study presents findings on the chemical and microbiological safety of the polyurea-based composite coating, designed for renovating potable water pipelines. Tests were performed in line with European standards PN-EN 12873-1, PN-EN 14395-1, and PN-EN 16421. The research examined metal, organic compound, and primary aromatic amine migration, along with organoleptic and microbiological water quality after contact with the coating. No regulatory limits were exceeded, and PAAs were below the detection threshold of 0.001 mg/L. These results demonstrate that COVERLAN does not adversely impact drinking water quality and is safe for use in internal pipeline rehabilitation.
PL
W pracy przedstawiono wyniki badań dotyczących bezpieczeństwa chemicznego i mikrobiologicznego kompozytowej powłoki na bazie polimocznika, przeznaczonej do renowacji przewodów wodociągowych do transportu wody do spożycia. Badania wykonano zgodnie z europejskimi normami PN-EN 12873-1, PN-EN 14395-1 oraz PN-EN 16421. Oceniano migrację metali, związków organicznych i pierwszorzędowych amin aromatycznych, a także właściwości organoleptyczne i mikrobiologiczne wody po kontakcie z powłoką. Nie stwierdzono przekroczenia dopuszczalnych wartości parametrów, a stężenia amin aromatycznych pozostawały poniżej progu oznaczalności 0,001 mg/L. Wyniki potwierdzają, że badany materiał nie wpływa negatywnie na jakość wody i może być bezpiecznie stosowany w technologiach renowacji wewnętrznych powłok rurociągów.
2
Content available remote Efektywność procesu UV/H2O2 w usuwaniu estrogenów ze środowisk wodnych
PL
Celem pracy była ocena skuteczności procesu UV/H2O2 w usuwaniu 17α-estradiolu z wody destylowanej i ścieków modelowych z wykorzystaniem metody QuEChERS-LC-MS/MS. Sama fotoliza UV zapewniała umiarkowaną redukcję (ok. 75% po 45 min), natomiast zastosowanie H2O2 wyraźnie zwiększało szybkość i efekt końcowy, prowadząc do niemal całkowitego usunięcia 17α-estradiolu (ok. 97% po 45 min). W próbie kontrolnej z samym H2O2 nie obserwowano ubytku, co potwierdza konieczność aktywacji fotochemicznej. Wyniki wskazują, że UV/H2O2 może być skutecznym i szybkim rozwiązaniem do ograniczania estrogenów w ściekach.
EN
The aim of this study was to evaluate the effectiveness of the UV/H2O2 process in removing 17α-estradiol from distilled water and model wastewater using the QuEChERS-LC-MS/MS method. UV photolysis alone provided moderate reduction (approx. 75% after 45 min), whereas the addition of H2O2 markedly increased the rate and final effect, leading to near-complete removal (approx. 97% after 45 min). In the control test with H2O2 only, no loss was observed, confirming the necessity of photochemical activation. The results indicate that UV/H2O2 can be an effective and rapid solution for reducing estrogens in wastewater.
4
EN
The aim of this study was to analyse the quality and compare the functional value of water from traditionally dug and drill wells located in west Poland. Basic physicochemical and microbiological (Escherichia coli in 100 ml, coliform bacteria in 100 ml, enterococci in 100 ml, total number of bacteria in 1 ml grown at 22 °C, total number of bacteria in 1 ml grown at 36 °C) were determination for the water samples. Additionally, some waters samples were analysed of the presence of heavy metals , TN (total nitrogen), TOC (total organic carbon) and NPOC (dissolved organic carbon). The conducted research has indicated that mineral and microbiological contamination occurs in the waters collected from the wells. This confirms that the wells were not sufficiently protected and that penetration of pollutants into the water occurs from their immediate surroundings, geological layers with which underground water resources come into contact.
PL
Celem pracy była analiza jakości i porównanie wartości użytkowej wód z tradycyjnie kopanych i wiertniczych studni zlokalizowanych w zachodniej Polsce. Określono podstawowe parametry fizykochemiczne i mikrobiologiczne (Escherichia coli w 100 ml, bakterie z grupy coli w 100 ml, enterokoki w 100 ml, łączna liczba bakterii w 1 ml hodowanych w 22°C, całkowita liczba bakterii w 1 ml hodowanych w 36°C) dla próbek wody. Dodatkowo w niektórych próbkach wód analizowano obecność metali ciężkich, TN (całkowity azot), TOC (całkowity węgiel organiczny) i NPOC (rozpuszczony węgiel organiczny). Przeprowadzone badania wykazały, że w wodach pobieranych ze studni występuje skażenie mineralne i mikrobiologiczne. Potwierdza to niedostateczną ochronę studni oraz przenikanie zanieczyszczeń do wód z ich bezpośredniego otoczenia, warstw geologicznych, z którymi stykają się zasoby wód podziemnych.
PL
Obiecującą strategią walki ze szkodliwymi dla zdrowia drobnoustrojami wydają się być tworzywa o właściwościach biobójczych.
PL
System REACH to pakiet legislacyjny obowiązujący na terenie Europejskiego Obszaru Gospodarczego, którego celem jest zwiększenie bezpieczeństwa zarządzania chemikaliami.
PL
Materiały biostatyczne i biobójcze pożądane są z uwagi na nowe wyzwania XXI w., związane z nabywaniem oporności bakterii na antybiotyki. Problem ten sprawia, że takie materiały są potrzebne w zastosowaniach ogólnych celem eliminacji warunków rozwoju i rozprzestrzeniania się tych patogenów.
EN
Due to the increasing problem resulting from environmental pollution with heavy metals, great emphasis is placed on the development of removal methods of these pollutants from the environment. This study presents a literature review on the methods for the removal of nickel ions from aqueous solutions such as sorption, especially using low-cost sorbents which are very popular in 21𝑠𝑡 century, electrochemical processes and membrane techniques. It is often impossible to use a single technique for efficient removal of heavy metals from wastewater as the process depends on many factors, such as wastewater composition, pH, temperature and many others. The aim of this review is to present some selected removal techniques of nickel(II) from wastewater from the point of view of their efficiency and applicability.
first rewind previous Strona / 4 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.