This study presents findings on the chemical and microbiological safety of the polyurea-based composite coating, designed for renovating potable water pipelines. Tests were performed in line with European standards PN-EN 12873-1, PN-EN 14395-1, and PN-EN 16421. The research examined metal, organic compound, and primary aromatic amine migration, along with organoleptic and microbiological water quality after contact with the coating. No regulatory limits were exceeded, and PAAs were below the detection threshold of 0.001 mg/L. These results demonstrate that COVERLAN does not adversely impact drinking water quality and is safe for use in internal pipeline rehabilitation.
PL
W pracy przedstawiono wyniki badań dotyczących bezpieczeństwa chemicznego i mikrobiologicznego kompozytowej powłoki na bazie polimocznika, przeznaczonej do renowacji przewodów wodociągowych do transportu wody do spożycia. Badania wykonano zgodnie z europejskimi normami PN-EN 12873-1, PN-EN 14395-1 oraz PN-EN 16421. Oceniano migrację metali, związków organicznych i pierwszorzędowych amin aromatycznych, a także właściwości organoleptyczne i mikrobiologiczne wody po kontakcie z powłoką. Nie stwierdzono przekroczenia dopuszczalnych wartości parametrów, a stężenia amin aromatycznych pozostawały poniżej progu oznaczalności 0,001 mg/L. Wyniki potwierdzają, że badany materiał nie wpływa negatywnie na jakość wody i może być bezpiecznie stosowany w technologiach renowacji wewnętrznych powłok rurociągów.
Globalne wyczerpywanie zasobów naturalnego piasku kwarcowego, napędzane dynamicznym wzrostem zapotrzebowania w sektorze budowlanym i przemysłowym, podkreśla konieczność poszukiwania alternatywnych źródeł surowców mineralnych. Odzysk frakcji bogatych w krzemionkę w procesach oczyszczania ścieków wpisuje się w zasady gospodarki o obiegu zamkniętym, zmniejszając ilość odpadów kierowanych na składowiska oraz ograniczając eksploatację naturalnych złóż. Dzięki korzystnym właściwościom fizykochemicznym krzemionka odzyskana ze ścieków może działać jako składnik wzmacniający właściwości użytkowe materiałów, a nie jedynie obojętny wypełniacz. Artykuł omawia technologie stosowane w oczyszczalniach ścieków do separacji i przygotowania piasku kwarcowego do ponownego wykorzystania oraz potencjalne zastosowania w materiałach budowlanych, systemach filtracyjnych i produkcji kompozytowych rur GRP. Przykłady praktycznych wdrożeń i aktualne badania wskazują, że odzyskana krzemionka stanowi wartościowy surowiec wtórny wspierający zrównoważone gospodarowanie zasobami w środowisku zurbanizowanym.
EN
The global depletion of natural quartz sand, driven by rapid growth in construction and industrial demand, underscores the need for alternative mineral resources. Recovering silica-rich fractions during wastewater treatment aligns with circular-economy principles by reducing landfill waste and limiting extraction of natural deposits. Due to favourable physicochemical properties, wastewater-derived silica can act as a functional performance-enhancing component rather than an inert filler. This article reviews technologies used in wastewater treatment plants for separating and preparing quartz sand for reuse, and discusses potential applications in construction materials, filtration systems and GRP composite pipe production. Practical examples and current research indicate that recovered silica represents a viable secondary raw material supporting sustainable urban resource management.
W artykule przedstawiono wyniki pilotażowych badań skuteczności filtrów tkaninowych MITA zastosowanych jako trzeci stopień oczyszczania ścieków w komunalnej oczyszczalni obsługującej do 15000 RLM. Celem projektu, realizowanego przez Politechnikę Poznańską oraz firmę Probiko-Aqua, było określenie efektywności tej technologii w poprawie parametrów fizykochemiczny ścieków oczyszczonych. Zastosowana metoda wyróżnia się prostą eksploatacją i korzystną ekonomiką w porównaniu z klasycznymi filtrami piaskowymi. Filtracja tkaninowa została włączona jako uzupełniający etap po oczyszczaniu biologicznym osadem czynnym a jej skuteczność oceniano na podstawie redukcji zawiesiny ogólnej, ChZT, BZT 5, fosforu ogólnego, azotu ogólnego i OWO. Przeprowadzone pomiary wykazały znaczną poprawę jakości ścieków po zastosowaniu filtrów MITA, zwłaszcza w zakresie usuwania zawiesi (redukcja o 70-85%) i poprawy klarowności. Dodatkowo zaobserwowano korzystny wpływ na efektywność końcowej dezynfekcji UV. Uzyskane wyniki wskazują, że technologia filtrów tkaninowych MITA, dzięki możliwości prostego i liniowego skalowania procesu może być skutecznie stosowana w oczyszczalniach ścieków każdej wielkości - od małych instalacji po duże obiekty komunalne.
EN
The article presents the results of pilot studies on the efficiency of MITA cloth filters used as the third stage of waste water treatment in a municipal wastewater treatment plant serving up to 15,000 PE. The aim of the project, carried out by Poznań University of Technology in cooperation with Probiko-Aqua, was to determine the effectiveness of this technology in improving the physicochemical parameters of treated wastewater. The applied method is characterized by simple operation ant favorable cost-effectiveness compared to conventional sand filters. Cloth filtration was implemented as a supplementary stage following biological treatment with activated sludge, and its performance was evaluated based on the reduction of tota suspended solids, COD, BOD5, total phosphorus, total nitrogen and TOC. The measurements showed a significant improvement in the quality of the effluent after the application of MITA filters, particularly in terms of suspended solids removal (reduction by 70-85%) and improved clarity. In addition, a positive impact on the efficiency of final UV disinfection was observed. The results indicate that the MITA cloth filter technology, owing to its capability for simple and linear process scaling, can be effectively applied in wastewater treatment plants of any size - from small facilities to large municipal installations.
4
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Celem pracy była ocena skuteczności procesu UV/H2O2 w usuwaniu 17α-estradiolu z wody destylowanej i ścieków modelowych z wykorzystaniem metody QuEChERS-LC-MS/MS. Sama fotoliza UV zapewniała umiarkowaną redukcję (ok. 75% po 45 min), natomiast zastosowanie H2O2 wyraźnie zwiększało szybkość i efekt końcowy, prowadząc do niemal całkowitego usunięcia 17α-estradiolu (ok. 97% po 45 min). W próbie kontrolnej z samym H2O2 nie obserwowano ubytku, co potwierdza konieczność aktywacji fotochemicznej. Wyniki wskazują, że UV/H2O2 może być skutecznym i szybkim rozwiązaniem do ograniczania estrogenów w ściekach.
EN
The aim of this study was to evaluate the effectiveness of the UV/H2O2 process in removing 17α-estradiol from distilled water and model wastewater using the QuEChERS-LC-MS/MS method. UV photolysis alone provided moderate reduction (approx. 75% after 45 min), whereas the addition of H2O2 markedly increased the rate and final effect, leading to near-complete removal (approx. 97% after 45 min). In the control test with H2O2 only, no loss was observed, confirming the necessity of photochemical activation. The results indicate that UV/H2O2 can be an effective and rapid solution for reducing estrogens in wastewater.
5
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The aim of this study was to analyse the quality and compare the functional value of water from traditionally dug and drill wells located in west Poland. Basic physicochemical and microbiological (Escherichia coli in 100 ml, coliform bacteria in 100 ml, enterococci in 100 ml, total number of bacteria in 1 ml grown at 22 °C, total number of bacteria in 1 ml grown at 36 °C) were determination for the water samples. Additionally, some waters samples were analysed of the presence of heavy metals , TN (total nitrogen), TOC (total organic carbon) and NPOC (dissolved organic carbon). The conducted research has indicated that mineral and microbiological contamination occurs in the waters collected from the wells. This confirms that the wells were not sufficiently protected and that penetration of pollutants into the water occurs from their immediate surroundings, geological layers with which underground water resources come into contact.
PL
Celem pracy była analiza jakości i porównanie wartości użytkowej wód z tradycyjnie kopanych i wiertniczych studni zlokalizowanych w zachodniej Polsce. Określono podstawowe parametry fizykochemiczne i mikrobiologiczne (Escherichia coli w 100 ml, bakterie z grupy coli w 100 ml, enterokoki w 100 ml, łączna liczba bakterii w 1 ml hodowanych w 22°C, całkowita liczba bakterii w 1 ml hodowanych w 36°C) dla próbek wody. Dodatkowo w niektórych próbkach wód analizowano obecność metali ciężkich, TN (całkowity azot), TOC (całkowity węgiel organiczny) i NPOC (rozpuszczony węgiel organiczny). Przeprowadzone badania wykazały, że w wodach pobieranych ze studni występuje skażenie mineralne i mikrobiologiczne. Potwierdza to niedostateczną ochronę studni oraz przenikanie zanieczyszczeń do wód z ich bezpośredniego otoczenia, warstw geologicznych, z którymi stykają się zasoby wód podziemnych.
System REACH to pakiet legislacyjny obowiązujący na terenie Europejskiego Obszaru Gospodarczego, którego celem jest zwiększenie bezpieczeństwa zarządzania chemikaliami.
Materiały biostatyczne i biobójcze pożądane są z uwagi na nowe wyzwania XXI w., związane z nabywaniem oporności bakterii na antybiotyki. Problem ten sprawia, że takie materiały są potrzebne w zastosowaniach ogólnych celem eliminacji warunków rozwoju i rozprzestrzeniania się tych patogenów.
Due to the increasing problem resulting from environmental pollution with heavy metals, great emphasis is placed on the development of removal methods of these pollutants from the environment. This study presents a literature review on the methods for the removal of nickel ions from aqueous solutions such as sorption, especially using low-cost sorbents which are very popular in 21𝑠𝑡 century, electrochemical processes and membrane techniques. It is often impossible to use a single technique for efficient removal of heavy metals from wastewater as the process depends on many factors, such as wastewater composition, pH, temperature and many others. The aim of this review is to present some selected removal techniques of nickel(II) from wastewater from the point of view of their efficiency and applicability.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.