Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 59

Liczba wyników na stronie
first rewind previous Strona / 3 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  protection against electric shock
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 3 next fast forward last
EN
In the TN low-voltage network containing overhead lines with bare conductors, there may be a risk of electric shock if a line (phase) conductor breaks and falls to the ground. This risk results from the potential of the network neutral point, the level of which may exceed the permissible value of 50 V during this fault. Therefore, it is necessary to determine the resistance to earth of the bare conductor lying on the ground, which affects the aforementioned potential. This article presents a theoretical analysis related to the bare conductor lying on the ground and the results of the resistance to earth measurements for such a conductor.
PL
W sieci niskiego napięcia o układzie TN zawierającej linie napowietrzne o przewodach gołych może powstać zagrożenie porażeniem w przypadku zerwania przewodu liniowego (fazowego) i opadnięcia na ziemię. Zagrożenie to wynika z przesunięcia potencjału punktu neutralnego sieci, którego wartość przy tym zakłóceniu może przekraczać dopuszczalne 50 V. Konieczne jest więc określenie rezystancji przejścia (rezystancji uziemienia) przewodu leżącego na ziemi, która wpływa na poziom potencjału punktu neutralnego sieci. W artykule przedstawiono analizę teoretyczną związaną z przewodem leżącym na ziemi oraz wyniki pomiarów rezystancji uziemienia takiego przewodu.
EN
This paper presents the concept and start-up measurements of a traction short-circuit system enabling field measurements to verify the effectiveness of protection against electric shock of a DC traction network in accordance with the PN-EN 50122:1:2023 standard. The presented system uses proprietary solutions, including optical separation of the control panel and the circuit breaker position, ensuring the safety of conducting short-circuit tests. The operation of the system is illustrated by the results of field measurements recorded on a railway facility.
PL
Niniejsza praca przedstawia koncepcję oraz pomiary rozruchowe trakcyjnego układu zwarciowego umożliwiającego terenowe pomiary weryfikacyjne skuteczności ochrony przeciwporażeniowej sieci trakcyjnej prądu stałego zgodnie z normą PNEN 50122:1:2023. W prezentowanym układzie zastosowano autorskie rozwiązania m. in. dotyczące optycznej separacji pulpitu sterowniczego oraz stanowiska wyłącznikowego, zapewniającego bezpieczeństwo prowadzenia prób zwarciowych. Działanie układu, zostało zilustrowane wynikami pomiarów terenowych, zarejestrowanych na obiekcie kolejowym.
PL
W instalacjach niskiego napięcia przeznaczonych do ładowania pojazdów elektrycznych obowiązkowe jest stosowanie zabezpieczeń różnicowoprądowych. W instalacjach tych istnieje jednak ryzyko pojawienia się w prądzie ziemnozwarciowym stosunkowo dużej wartości składowej stałej, która negatywnie wpływa na próg zadziałania powszechnie instalowanych wyłączników różnicowoprądowych. Konieczny jest więc dobór zabezpieczenia zdolnego do wykrywania tej składowej, np. zabezpieczenia różnicowoprądowego typu RDC-DD. W artykule przedstawiono wyniki badań działania takich zabezpieczeń przy prądzie różnicowym sinusoidalnym o częstotliwości 50 Hz oraz przy prądzie różnicowym jednokierunkowym.
EN
In low-voltage installations intended for charging of electric vehicles, the use of residual current devices is mandatory. However, in such installations there is a risk of occurrence of an earth fault current containing a relatively high value of the DC component. Therefore, it is necessary to select protection device capable of detecting this component, e.g. a residual direct current detecting device (RDC-DD). The paper presents the results of tests of the operation of example RDC-DDs under a sinusoidal current having 50 Hz and under a unidirectional current.
EN
The main requirements of national regulations and international standards regarding protection against electric shock in electric vehicle charging installations are presented. The principles of using residual current devices (RCDs) in such installations are discussed. It is pointed out that RCDs are mandatory equipment for safe charging of electric vehicles. It is noted that the standards require the use of RCDs having an appropriate type of tripping, due to the fact that in the event of an earth fault in the charging circuit, a DC component of significant value may appear in the earth fault current. A new type of residual current devices for DC installations (DC-RCD) has been indicated.
PL
W artykule przedstawiono zasady ochrony przeciwporażeniowej i stosowania wyłączników różnicowoprądowych (RCDs) w instalacjach przeznaczonych do ładowania pojazdów elektrycznych. Omówiono wymagania przepisów i norm, w szczególności zwrócono uwagę na obowiązek stosowania takich zabezpieczeń w instalacjach ładowania pojazdów. Zaznaczono, że normy wymagają zastosowania wyłączników różnicowoprądowych o odpowiednim typie wyzwalania, aby zapewnić skuteczną ochronę przeciwporażeniową w przypadku pojawienia się w prądzie ziemnozwarciowym składowej stałej o znacznej wartości. Podano podstawowe informacje dotyczące nowego typu wyłączników różnicowoprądowych przeznaczonego do instalacji prądu stałego (DC-RCD).
PL
Przedstawiono właściwości zabezpieczeń różnicowoprądowych z punktu widzenia ich zdolności do wykrywania określonego kształtu przebiegu prądu różnicowego. Podano wymagania norm odnoszące się do zabezpieczeń różnicowoprądowych stosowanych w instalacjach ładowania pojazdów elektrycznych. Omówiono charakterystyki działania zabezpieczeń IC-CPD oraz RDC-DD, które są przeznaczone do instalacji zapewniających ładowanie pojazdu elektrycznego odpowiednio w trybie 2 oraz 3.
EN
The properties of residual current devices have been presented from the point of view of their ability to detect a specific shape of the residual current waveform. Moreover, the standard requirements relating to residual current protection used in electric vehicle charging installations have been pointed out. The operating characteristics of the IC-CPD and RDC-DD protections, which are intended for charging electric vehicles in mode 2 and mode 3, respectively, have been also discussed.
EN
The properties of residual current devices have been presented from the point of view of their ability to detect a specific shape of the residual current waveform. Moreover, the standard requirements relating to residual current protection used in electric vehicle charging installations have been pointed out. The operating characteristics of the IC-CPD and RDC-DD protections, which are intended for charging electric vehicles in mode 2 and mode 3, respectively, have been also discussed.
PL
Przedstawiono właściwości zabezpieczeń różnicowoprądowych z punktu widzenia ich zdolności do wykrywania określonego kształtu przebiegu prądu różnicowego. Podano wymagania norm odnoszące się do zabezpieczeń różnicowoprądowych stosowanych w instalacjach ładowania pojazdów elektrycznych. Omówiono charakterystyki działania zabezpieczeń IC-CPD oraz RDC-DD, które są przeznaczone do instalacji zapewniających ładowanie pojazdu elektrycznego odpowiednio w trybie 2 oraz 3.
PL
Artykuł przedstawia metodykę weryfikacji zabezpieczeń nadprądowych w mikrosieci niskiego napięcia pod kątem dostosowania jej do pracy w trybie wyspowym. Metodyka umożliwia sprawdzenie skuteczności ochrony przeciwporażeniowej i selektywności działania zabezpieczeń. Jest ona pokazana na przykładzie mikrosieci o topologii zakładającej przyłączenie lokalnych źródeł energii i magazynu energii do szyn stacji, która zasila odbiorców na wybranym obszarze.
EN
The paper presents the methodology of protection verification in terms of adopting the low-voltage microgrid to island operation. The methodology enables the checking of effectiveness of protection against electric shock and selectivity of protection operation. The whole process of verification is shown relying on case study of the microgrid which topology assumes both local power sources and storage energy equipment interconnection with the substation supplying the customers in particular area.
EN
The paper presents the principles of residual current devices (RCDs) application in photovoltaic (PV) installations. Provisions of standards in this regard are commented on, in particular, attention is drawn to the lack of obligation to use of RCDs in PV installations. The issue of the shape of the earth fault current and the level of leakage currents in such installations are discussed. These factors influence the selection of RCDs in terms of their rated residual operating current as well as the type of tripping characteristic.
PL
W artykule przedstawiono zasady stosowania wyłączników różnicowoprądowych (RCDs) w instalacjach fotowoltaicznych (PV). Skomentowano zapisy norm w tym zakresie, w szczególności zwrócono uwagę na brak obowiązku stosowania takich zabezpieczeń w instalacjach PV. Omówiono problematykę kształtu prądu ziemnozwarciowego oraz poziom prądów upływowych charakteryzujący te instalacje – są to czynniki wpływające na dobór znamionowego prądu różnicowego oraz typu charakterystyki wyzwalania wyłączników różnicowoprądowych.
PL
Magazyny energii w pojazdach elektrycznych mają zainstalowany system BMS, który kontroluje parametry eksploatacyjne baterii akumulatorów oraz ma wbudowane zabezpieczenia: nadprądowe, podnapięciowe, nadnapięciowe i termiczne. W sytuacjach awaryjnych pojazdu i uszkodzeniu obudowy akumulatora system BMS nie zabezpiecza jednak ludzi przed porażeniem napięciem baterii trakcyjnej. W artykule przedstawiono koncepcję podziału baterii trakcyjnej na moduły, z których każdy ma napięcie nie wyższe niż traktowane jako bezpieczne dla ludzi. Moduły baterii połączono stycznikami, a na obudowie baterii umieszczono czujnik uderzeniowy. Uzwojenia sterujące styczników połączono z akumulatorem niskonapięciowym, systemem BMS i z czujnikiem uderzeniowym. W przypadku kolizji drogowej pojazdu i zadziałania czujnika uderzeniowego prąd w obwodzie uzwojeń sterujących zostaje wyłączony i styczniki rozłączają moduły baterii. Także w czasie postoju pojazdu lub zdjęcia obudowy system BMS przerywa prąd w uzwojeniach sterujących styczników i moduły baterii są rozłączone.
EN
Energy stores in electric vehicles have a BMS installed that controls the operating parameters of the battery pack, and has built-in overcurrent, undervoltage, overvoltage, and thermal protection. However, during vehicle emergencies and battery case damage, the BMS does not protect people from being shocked by the traction battery voltage. This paper presents the concept of dividing the traction battery into modules, each of which has a voltage no higher than that treated as safe for humans. The battery modules are connected by contactors and a shock sensor is placed on the battery housing. The control windings of the contactors are connected to the low voltage battery, the BMS system and the impact sensor. In the event of a road ollision with the vehicle and activation of the impact sensor, the current in the control windings circuit is switched off and the contactors disconnect the battery modules. Also, when the vehicle is stationary or the chassis is removed, the BMS interrupts the current in the control windings of the contactors and the battery modules are disconnected.
EN
Residual current devices (RCDs) are most popular devices used in low-voltage installations for protection against electric shock and fire. In cases of high risk of electric shock the application of RCDs is mandatory. Currently, the spread of local direct current (DC) microgrids is widely considered. This creates new challenges for protective systems, in particular those based on RCDs. The main purpose of the research is to test the operation of B-type RCDs by simulating the conditions that may occur in DC microgrids as well as assessment of the effectiveness of electrical safety with the use of such RCDs. The research has revealed that theoretically identical RCDs in terms of technical data can have different tripping properties, including no reaction to residual direct current, which poses a risk of electric shock. This signalizes the necessity of extension of the normative tests performed by manufacturers. The scope of these additional RCDs tests is indicated, from the point of view of the persons’ safety in DC microgrids.
EN
The peculiarities of the operation of distributed generation systems lead to a change in the requirements for the reliability and safety of the power distribution systems in which they are integrated. To meet the increased requirements, continuous monitoring of the insulation parameters (active resistance and capacitance to ground) is often used with operating artificial non-industrial frequency operational signals introduced into the network. In the case of a sudden touch, such a system is not effective, since the response time of the protection device, which consists of the signal processing time and the operating of the actuator, is crucially important. For the used operational signals with a frequency of 100 and 200 Hz, the processing time using the Fourier transform is 10 ms for 100 Hz and 5 ms for 200 Hz. Considering that the response time of the fastest actuators (based on vacuum switches) is from 3 to 7 ms, this is a rather significant period of time. To develop an effective resolver system, the capabilities of the Matlab environment were used to determine the most successful design of an analog prototype (Butterworth, Bessel, Chebyshev and Cauer of 6th order) for an operational signal with a frequency of 200 Hz. As a result, the processing time was established, which varies widely from 3.5 to 19 ms. Taking into account the known indicators, namely the frequency and number of operational signals, a signal processing system was developed using the vector-matrix analysis method. As a result of modeling the processing characteristics of functional signals (at a sampling rate of 1 kHz), the system quick-response was 3 ms, with the possibility of its further decrease as its productiveness increases.
PL
Sieci rozdzielcze niskiego napięcia (nn) eksploatowane w Polsce, są w większości w układzie TN-C, w którym najpowszechniej stosowanym środkiem ochrony przeciwporażeniowej przy uszkodzeniu jest samoczynne wyłączanie zasilania. W obwodach liniach napowietrznych do samoczynnego wyłączania zasilania powszechnie wykorzystywane są wkładki topikowe o charakterystyce gG. Dla tych obwodów, dla których pomiary eksploatacyjne wykazały nieskuteczną ochronę przeciwporażeniową, stosowane są wkładki topikowe o charakterystyce gF, które nie są przedmiotem norm europejskich: PN-EN 60269-1 oraz PN-EN 60269-2, a ich produkcja oparta jest o normy zakładowe. W artykule przedstawiono propozycję zmiany charakterystyk prądowo-czasowych dotychczasowych wkładek topikowych gF, aby możliwe było spełnienie ww. wymagań normatywnych, m.in. w zakresie sprawdzenia charakterystyk, a w szczególności granic charakterystyk pasmowych.
EN
Low-voltage (LV) distribution networks operated in Poland, are mostly in the TN-C system. The most commonly used means of additional protection against electric shock during damage is automatic switching off the power supply. In low voltage overhead line circuits, most often, these are fuse links with gG characteristics. In these circuits, where operational measurements have shown ineffective protection against electric shock, are mostly used fuse links with gF characteristics, which are not subject of European standards: EN 60269-1 and PN EN 60269-2 and their production is based on factory standards. The paper presents a proposal of changing the tripping characteristics of the current gF fuse links in order to be able to meet the normative requirements, including the verification of tripping characteristics, in particular the limits of band characteristics.
PL
W artykule przedstawiono wyposażenie gospodarstw wiejskich w wybrane urządzenia elektryczne oraz przeanalizowano stan techniczny instalacji i sieci elektroenergetycznych, w tym jakość dostarczanej energii elektrycznej, pod kątem zagrożeń odbiorców porażeniem prądem elektrycznym i oddziaływaniem pól elektromagnetycznych.
EN
The paper presents the equipment of rural households with selected electrical receivers. The technical condition of power installations and networks, including the quality of electricity supply, in terms of the consumer risks by electric shock and the effects of electromagnetic fields were analysed.
PL
Zagrożenie porażeniem prądem elektrycznym jest podstawowym rodzajem zagrożenia towarzyszącego procesom wykorzystania energii elektrycznej oraz użytkowania maszyn i urządzeń zasilanych energią elektryczną. Podstawowym środkiem bezpieczeństwa stosowanym przy zagrożeniu porażeniem prądem elektrycznym jest izolacja stosowana w formie różnych rozwiązań technicznych przede wszystkim po stronie urządzeń elektrycznych, która pozwala przeciętnemu użytkownikowi na bezpieczne użytkowanie urządzeń elektrycznych w podstawowym zakresie ich przeznaczenia [...].
EN
The risk of electric shock is the basic type of risk that accompanies the processes of electricity use and the use of machinery and equipment powered by electricity. The basic safety measure applied reduce the risk of electric shock is the insulation used in the form of various technical solutions, primarily on the electrical devices (constructionally designed insulation of active parts), which allows the average user to safely use electrical devices in the basic scope of their use. The construction of electrical equipment and its periodic service (maintenance, repair, modernization, etc.) often take place in conditions of insufficient insulation of the active parts or intentionally without insulation and without power supply disconnected, which is dictated by the technology of performing these works. Professional electricians and assemblers of electrical equipment and appliances are then subject to an increased risk of electric shock, which forces the use of basic and additional protective measures to reduce this risk to the level required by the regulations. Safety equipment that reduces the risk of electric shock relies heavily on electrical insulating protection measures intended for both individual and collective use. The article will describe the design features and safety requirements for the selected electrical insulating equipment: ladders, hand tools, rigid and flexible covers. The rules for the selection of this protective equipment and the requirements for its use, periodic inspections and storage will be presented
PL
Zagrożenie porażeniem prądem elektrycznym jest podstawowym rodzajem zagrożenia towarzyszącego procesom wykorzystania energii elektrycznej oraz użytkowania maszyn i urządzeń zasilanych energią elektryczną. Podstawowym środkiem bezpieczeństwa stosowanym przy zagrożeniu porażeniem prądem elektrycznym jest izolacja stosowana w formie różnych rozwiązań technicznych, przede wszystkim po stronie urządzeń elektrycznych (konstrukcyjnie przewidziana izolacja części czynnych), która pozwala przeciętnemu użytkownikowi na bezpieczne użytkowanie urządzeń elektrycznych w podstawowym zakresie ich przeznaczenia. Budowanie urządzeń elektrycznych oraz ich okresowa obsługa (konserwacja, naprawa, modernizacja itp.) często odbywają się w warunkach niedostatecznej izolacji części czynnych lub celowo bez izolacji oraz przy nie wyłączonym zasilaniu energią elektryczną, co podyktowane jest technologią wykonywania tych prac. Zawodowi elektrycy i monterzy urządzeń i wyposażenia elektrycznego podlegają wtedy zwiększonemu ryzyku porażenia prądem elektrycznym, co wymusza stosowanie podstawowych i dodatkowych środków ochronnych do obniżenia tego ryzyka do poziomu wymaganego przez przepisy. Wyposażenie bezpieczeństwa zmniejszające ryzyko porażenia prądem elektrycznym w znacznym stopniu opiera się na elektroizolacyjnych środkach ochronnych przewidzianych zarówno do użytku indywidualnego, jak i zbiorowego. W artykule scharakteryzowane zostaną cechy konstrukcyjne i wymagania bezpieczeństwa dotyczące wybranego sprzętu elektroizolacyjnego: drabin, narzędzi ręcznych, osłon sztywnych i elastycznych. Przedstawione zostaną zasady doboru tego sprzętu ochronnego oraz wymagania dotyczące jego użytkowania, kontroli okresowych i przechowywania.
EN
The risk of electric shock is the basic type of risk that accompanies the processes of electricity use and the use of machinery and equipment powered by electricity. The basic safety measure applied reduce the risk of electric shock is the insulation used in the form of various technical solutions, primarily on the electrical devices (constructionally designed insulation of active parts), which allows the average user to safely use electrical devices in the basic scope of their use. The construction of electrical equipment and its periodic service (maintenance, repair, modernization, etc.) often take place in conditions of insufficient insulation of the active parts or intentionally without insulation and without power supply disconnected, which is dictated by the technology of performing these works. Professional electricians and assemblers of electrical equipment and appliances are then subject to an increased risk of electric shock, which forces the use of basic and additional protective measures to reduce this risk to the level required by the regulations. Safety equipment that reduces the risk of electric shock relies heavily on electrical insulating protection measures intended for both individual and collective use. The article will describe the design features and safety requirements for the selected electrical insulating equipment: ladders, hand tools, rigid and flexible covers. The rules for the selection of this protective equipment and the requirements for its use, periodic inspections and storage will be presented.
EN
The conventional approach to electrical safety under fault condition in typical power systems considers earth fault currents of sinusoidal waveform and frequency of 50‒60 Hz. However, in circuits with variable-speed drives, there is earth fault current flow with harmonics, and these harmonics influence the threshold of ventricular fibrillation. The paper presents earth fault current waveforms in circuits with variable-speed drives without inverter output (motor) filter and with one of the two types of inverter output filters being used. The details of both filters are presented, and the effect of harmonics of earth fault current on ventricular fibrillation is evaluated. Furthermore, the effect of harmonics, which occurs in circuit of variable-speed drive, on the tripping current of residual current devices is presented. Residual current devices may be utilized to ensure protection against direct and indirect contact, but limitations in their proper operation, due to harmonics, may exist. Operational characteristics of a proposed residual current device dedicated to circuits with earth fault current containing harmonics, as in the variable-speed circuits, are presented.
PL
W artykule omówiono zasady wykonywania prób i pomiarów w instalacjach elektrycznych niskiego napięcia. Dokonano przeglądu postanowień najnowszej normy dotyczącej sprawdzania instalacji i zwrócono uwagę na zmiany przez nią wprowadzone.
EN
In the paper principles of testing of safety in low voltage systems, according to the standard PN-HD 60364-6:2016-07, are presented. The new provisions of the standard are compared with the provisions presented in the previous version: PNHD 60364-6:2008. Main changes in these provisions are underlined. It may be concluded that the new standard introduces only slight modifications to the verification process.