Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 123

Liczba wyników na stronie
first rewind previous Strona / 7 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  AAC
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 7 next fast forward last
2
EN
The article presents the results of experimental tests of reinforced lintels made of autoclaved aerated concrete assembled incorrectly. The subject of the tests were models diversified in terms of the width of the cross-section and the geometry of the reinforcement. Failure loads, loads causing the loss of anchorage of the tensile reinforcement, deflections and cracks were tested. The test results were compared with the results of load-bearing capacity tests of lintels assembled correctly.
PL
W artykule przedstawiono wyniki badań doświadczalnych zbrojonych nadproży wykonanych z autoklawizowanego betonu komórkowego ułożonych w nieprawidłowy sposób. Przedmiotem badań były modele zróżnicowane pod względem szerokości przekroju poprzecznego oraz geometrii zbrojenia. Badano siły niszczące, siły powodujące utratę zakotwienia zbrojenia rozciąganego, ugięcia oraz zarysowania. Wyniki porównano z wynikami badań nośności nadproży ułożonych w sposób prawidłowy.
PL
Określanie wytrzymałości na ściskanie muru w warunkach in-situ jest niezbędne w pracach diagnostycznych do określania bezpieczeństwa konstrukcji. Najbardziej wiarygodną metodą są badania pobranych fragmentów ścian, ale ze względu na stopień uszkodzeń diagnozowanej konstrukcji są rzadko stosowane. Coraz częściej stosuje się metody nieniszczące, które wymagają odpowiedniej walidacji na pobranych z konstrukcji rdzeniach. Późniejsza aplikacja otrzymanych korelacji prędkość fali ultradźwiękowej – wytrzymałość na ściskanie cp – fc powinna uwzględniać wpływ występującego w elementach murowych stanu naprężeń. W celu wyznaczenia skorygowanej prędkości fali ultradźwiękowej w elementach murowych wykorzystano efekt elastoakustyczny (AE), który bazuje na korelacji prędkości fal ultradźwiękowych z wartością i kierunkiem działających naprężeń. Wykorzystując badania AE i opracowane zależności wiążące wartość średnich naprężeń hydrostatycznych P z prędkościami podłużnej fali ultradźwiękowej cp zaproponowano autorską metodę uwzględniania wpływu wytężenia konstrukcji murowej.
EN
Determining the compressive strength of masonry under in-situ conditions is essential in diagnostic investigations aimed at assessing structural safety. Although testing of extracted wall fragments is considered the most reliable method, it is rarely applied due to the extent of damage it causes. As a result, non-destructive methods are increasingly being employed; however, they require appropriate validation using cores taken from the structure. When applying the resulting correlations between ultrasonic wave velocity cp and compressive strength fc, it is necessary to account for the influence of the stress state present in the masonry elements. To determine the corrected ultrasonic wave velocity in masonry under load, the acoustoelastic effect (AE) was utilised. This phenomenon is based on the relationship between ultrasonic wave velocity and both the magnitude and direction of acting stresses. Based on AE tests and developed correlations between the average hydrostatic stress (P) and longitudinal ultrasonic wave velocity (cp ), an original method was proposed to account for the effect of structural stress on masonry elements.
EN
The article presents the results of original research on wall connections made of autoclaved aerated concrete subjected to shear with bending. The shape of the test element and the test stand layout were innovatively selected based on the author’s research, a literature review, and numerical analyses. The study examined crack morphology and failure mechanisms, comparing load-displacement relationships for different types of connections. The obtained results were referenced against those from a reference model featuring a traditional masonry bond. In other test models, the connection was formed using steel connectors. For wall connections without a masonry bond, commonly available steel connectors from the construction market and a proprietary metal plate were used. The study demonstrated varied cracking and failure mechanisms, as well as significant differences in the behavior and load-bearing capacity of each connection type. The obtained results encourage further analyses to refine connections and explore new construction methods for wall joints.
PL
W pracy przedstawiono wyniki badań doświadczalnych 4 serii (łącznie 24 modeli badawczych) połączeń wzajemnie prostopadłych ścian wykonanych z elementów murowych z autoklawizowanego betonu komórkowego (abk) poddanych ścinaniu ze zginaniem. Badano modele referencyjne składające się z dwóch ścian połączonych prostopadle tradycyjnym wiązaniem murarskim oraz modele o takiej samej geometrii, ale ze zmodyfikowanym sposobem łączenia - z wykorzystaniem różnych, dostępnych na rynku typów łączników (blach, kratowniczek). Dokonano analizy dotyczącej nośności oraz morfologii i mechanizmu uszkodzeń modeli.
EN
The paper presents the results of experimental tests of 4 series (a total of 24 research models) of mutually perpendicular joints of walls made of autoclaved aerated concrete (aac) masonry elements subjected to shearing with bending. Reference models consisting of two walls connected perpendicularly with a traditional masonry bond and models with the same geometry, but with a modified method of connection - using various types of connectors available on the market (plates, trusses) were tested. An analysis of the load capacity, morphology and damage mechanism of the models was made.
EN
In 2023, the production of AAC modular wall panels began in Poland. The panels have the advantages of aerated concrete, but the installation time is significantly shorter, which may translate into a significant increase in the popularity of the technology in Poland. The paper discusses the fields of application, the technology of assembly, compares the labor intensity in relation to walls made of other materials, and discusses microeconomic factors that may affect the available technologies on the market in the future.
PL
W 2023 r. w Polsce rozpoczęła się produkcja paneli ściennych z betonu komórkowego. Panele mają zalety betonu komórkowego, przy czym czas ich montażu jest znacznie krótszy niż stosowanych bloczków z ABK do wykonywania ścian, co może przełożyć się na istotny wzrost popularności technologii w Polsce. W artykule omówiono możliwości zastosowania paneli, sposób wykonywania ścian w tej technologii, porównano pracochłonność w odniesieniu do przegród z innych materiałów oraz omówiono czynniki mikroekonomiczne, które mogą wpłynąć na dostępne technologie wykonywania przegród w najbliższych latach.
18
Content available remote Kotwienie i mocowanie w betonie komórkowym
EN
The article presents the possibility of applying moisture desorption processes for determining the diffusion coefficient. Two calculation methods are presented – the √t type method for the initial phase of the process and the logarithmic method for the advanced phase. Their application is presented on the example of autoclaved aerated concrete class 400, for desorption processes occurring in the humidity range 98 → 85%. The difference between the diffusion coefficients Dm(√t) and Dm(ln) did not exceed 20%.
PL
W artykule przedstawiono możliwość wykorzystania procesów desorpcji wilgoci do wyznaczania współczynnika dyfuzji. Zaprezentowano dwie metody obliczeniowe – metodę typu √t dotyczącą fazy wstępnej procesu i metodę logarytmiczną odnoszącą się do fazy zaawansowanej. Ich zastosowanie zaprezentowano na przykładzie betonu komórkowego klasy 400, w przypadku procesów desorpcji zachodzących w wilgotności 98 → 85%. Różnice między współczynnikami dyfuzji Dm(√t) i Dm(ln) nie przekroczyły 20%.
PL
W artykule przedstawiono badawczą i obliczeniową analizę wpływu zewnętrznego wzmocnienia na nośność na ścinanie ścian wykonanych z bloczków z autoklawizowanego betonu komórkowego (ABK). Jako wzmocnienie zastosowano niekonstrukcyjne materiały, tj. siatkę szklaną i zaprawę tynkarską, które są przeznaczone do prac termomodernizacyjnych. W pierwszej części omówiono i pokazano wyniki badań poszczególnych materiałów i zestawu wzmacniającego w postaci próbek zakładkowych i typu coupon oraz normowe badania modelowe ścian o wymiarach 1,2 x 1,2 m. Przebadano dwa sposoby ułożenia siatek na powierzchni modeli (poziomo i pionowo), wykazując, że w przypadku użytych materiałów obydwie konfiguracje przynoszą podobne wzrosty nośności na ścinanie wynoszące odpowiednio 89% i 80%. Na podstawie parametrów wyznaczonych w badaniach materiałowych w zakresie efektywnych odkształceń i modułu sprężystości, obliczono, zarówno na podstawie wybranych wytycznych literaturowych, jak i z uwzględnieniem zaproponowanej modyfikacji własnej, udział wzmocnienia w nośności badanych elementów. Porównanie wyników uzyskanych z obliczeń i z badań modelowych wykazało ich bardzo dużą zgodność.
EN
The article presents a research and computational analysis of the effect of external strengthening on the shear capacity of walls made of autoclaved aerated concrete (AAC) blocks. Non-structural materials, i.e. glass mesh and plaster mortar, which are used in thermal modernization works, were used as strengthening. The first part discusses and shows the results of testing of individual materials and strengthening set in the form of single-lap and coupon type specimens, as well as standard model tests of 1.2 x 1.2 m walls. Two arrangements of meshes on the surface of the models (horizontally and vertically) were tested, showing that for the materials used, both configurations yield similar increases in shear capacity of 89% and 80%, respectively. On the basis of the parameters determined in the material tests, that is, the effective strains and the modulus of elasticity of the strengthening, the contribution of the strengthening to the load capacity of the strengthened walls was calculated, directly on the basis of literature guidelines, as well as taking into account the proposed modification. Comparison of the results derived from the calculations and model tests indicated very good agreement.
first rewind previous Strona / 7 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.