Znaleziono wyników: 93

Liczba wyników na stronie
first rewind previous Strona / 5 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  electromagnetic interference
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 5 next fast forward last
EN
This paper reports an experimental evaluation of electrostatic discharge (ESD) effects on three cable types—coaxial, LAN Cat. 6 UTP, and BNC signal–under IEC 61000-4-2 bench conditions. Discharges were applied in air-discharge mode at voltages up to 25 kV, and disturbances were analyzed using repeated measurements in both time and frequency domains. The results indicate that LAN cables exhibit the highest susceptibility, producing voltages above 30 V and high disturbance energies, while coaxial cables show predictable linear growth with moderate values. The BNC signal cable demonstrated the lowest disturbance levels and the most repeatable FFT spectral characteristics, confirming its superior robustness.
PL
W artykule przedstawiono eksperymentalną ocenę wpływu wyładowań elektrostatycznych (ESD) na trzy typy kabli: koncentryczny, sieciowy LAN Cat. 6 UTP oraz sygnałowy BNC, w warunkach stanowiska zgodnego z normą IEC 61000-4-2. Wyładowania w trybie powietrznym realizowano przy napięciach do 25 kV, a zakłócenia analizowano na podstawie wielokrotnych pomiarów w dziedzinie czasu i częstotliwości. Wyniki wskazują, że kable LAN są najbardziej podatne, generując napięcia powyżej 30 V oraz wysokie energie zakłóceń, podczas gdy kable koncentryczne wykazują przewidywalny liniowy wzrost o umiarkowanych wartościach. Kabel sygnałowy BNC charakteryzował się najniższymi poziomami zakłóceń i najwyższą powtarzalnością charakterystyk FFT, co potwierdza jego zwiększoną odporność.
PL
W poprzednim artykule (Przegląd elektrotechniczny, r. 99 nr 9/2023) przedstawione zostały wstępne wyniki komputerowych badań symulacyjnych (Computational Electromagnetics – Elektromagnetyka obliczeniowa), z których wynika, że intencjonalne impulsowe zaburzenie elektromagnetyczne (EM) skierowane na wybrany cel (obiekt elektroniczny) może oddziaływać również na środowisko elektromagnetyczne poprzez elektryzowanie napotykanych obiektów metalowych (niekoniecznie z infrastrukturą elektroniczną), które w rezultacie stają się niepożądanymi wtórnymi źródłami pola EM w czasie i po przejściu tego zaburzenia. W niniejszym artykule przedstawiona zostaje morfologia fal EM (pola elektryczne, magnetyczne i gęstości mocy promieniowania EM (wektora Poyntinga)) generowanych przez obiekt metalowy w czasie jego elektryzowania podczas przemieszczania się intencjonalnego impulsowego zaburzenia EM przez ten obiekt oraz po jego przejściu, kiedy zachodzi relaksacja obiektu do stanu Fneutralności elektrycznej. Z wykonanych symulacji morfologii wtórnych fal EM generowanych przez zakłócony elektromagnetycznie metalowy obiekt, niebędący bezpośrednim celem ataku EM wynika, że wtórne fale EM mogą stanowić poważne zaburzenie środowiska elektromagnetycznego wokół metalowych obiektów zakłóconych atakiem elektromagnetycznym skierowanym na inny cel.
EN
In a previous study published in Przegląd Elektrotechniczny (Vol. 99, No. 9/2023), preliminary results from computational electromagnetics simulations were presented. The findings showed that intentional electromagnetic interference (IEMI), directed at a selected electronic target, may also influence the surrounding electromagnetic environment. This occurs through electrostatic charging of encountered metallic objects, even if they are not part of any electronic infrastructure. Such objects can become unintended secondary sources of electromagnetic radiation. These emissions may occur both during and after the passage of the IEMI pulse. The current study analyzes the morphology of the resulting electromagnetic fields. This includes electric and magnetic field distributions, as well as the electromagnetic power density represented by the Poynting vector. The analysis focuses on two phases: the charging phase, when the pulse interacts with the metallic object, and the relaxation phase, when the object returns to an electrically neutral state. Simulation results demonstrate that such non-targeted metallic objects may emit significant secondary electromagnetic waves. These emissions can disturb the local electromagnetic environment. The results highlight the importance of considering such secondary effects when assessing the impact of IEMI and developing strategies for electromagnetic resilience.
EN
Energy conversion electronics, commonly known as power electronics, have become an essential component of elec trical engineering, with nearly 15% of all generated electrical energy undergoing conversion. Recent advancements in power semiconductor technology have led to the development of smaller, lighter, more cost ‑effective, and efficient power converters. In modern industrial applications – particularly in pumps, fans, and compressors – DC motor drives are widely used due to their ability to precisely meet operational requirements. However, conducted electromagnetic interference (EMI) in such systems can adversely affect performance and even cause malfunction. This paper presents a comparative simulation study of two DC/DC converter topologies used in controlling DC motor drives: the conventional series chopper and the synchronous switching chop per. Conducted EMI is analyzed under both common mode (CM) and differential mode (DM) using circuit modeling in LTspice. The series chopper employs an IRF530 MOSFET and an MUR460 diode, while the synchronous chopper utilizes two IRF530 MOS FETs for bidirectional switching. Simulation results demonstrate that the synchronous chopper exhibits significantly lower EMI levels in both CM and DM compared to the series configuration. This improvement is primarily attributed to reduced dv/dt and di/dt transients. These findings highlight the effectiveness of synchronous switching in enhancing electromagnetic compatibility (EMC) in DC motor drive systems.
PL
Energoelektronika, zwana powszechnie elektroniką mocy staje się podstawowym komponentem inżynierii elektryc znej, przy czym prawie 15% całej wytworzonej energii elektrycznej, podlega konwersji. Ostatnie osiągnięcia w zakresie technologii półprzewodnikowych elementów mocy doprowadziły do opracowania mniejszych, lżejszych, tańszych i wydajnych przetworników mocy. W nowoczesnych zastosowaniach przemysłowych – szczególnie w pompach, wentylatorach i sprężarkach – w napędach silników prądu stałego (DC) są one szeroko stosowane z powodu swej zdolności do precyzyjnego spełniania wymagań operacyjnych. Jednakże elektromagnetyczna interferencja (EMI) w takich układach może w sposób negatywny wpływać na ich funkcjonowanie a nawet powodować awarie. Niniejsza praca przedstawia porównawcze badanie symulacyjne dwóch topologii konwertera DC/ DC stosowanych w sterowaniu napędami silników DC: tradycyjny szeregowy wirnik praz wirnik z synchronicznym przełączaniem. Przeprowadzona EMI jest analizowana pod kątem zarówno prądu wspólnego (CM) jak i prądu stałego (DC), stosując modelow anie obwodu w programie LTspice. W wirniku seryjnym zastosowano diody IRD530 MOSFET i MUR 460, podczas gdy w wirniku z synchronizacją dwie IRF530 MOSFET dla dwukierunkowego przełączania. Wyniki przeprowadzonej symulacji pokazują że wirnik z synchronizacją wykazuje istotnie niższe poziomy EMI w porównaniu do konfiguracji szeregowej. Omawiane usprawnienie jest głównie związane ze zredukowanymi przejściówkami dv/dt i di/dt. Niniejsze odkrycia podkreślają efektywność synchronicznego przełączania we wzmacnianiu kompatybilności elektromagnetycznej (EMC) w układach napędowych silników DC.
EN
With the widespread use of miniaturized electronic equipment in daily life, the problem of electromagnetic interference has become increasingly prominent, especially in precision instruments and communication equipment. To effectively reduce the causes of mechanical noise generated by small DC electrodes during operation and the electromagnetic interference effects on surrounding equipment, a mechanical noise control method that combines piezoelectric impedance technology and back-propagation neural networks is proposed. In the process, small DC motor electrodes were used as the research object, and the sources of mechanical noise generated by the motor were analyzed. At the same time, different analysis software was used to simulate and model the stator and rotor of the motor. The results show that when different algorithms are run on the training set and test set, when the amount of data increases to 560 and 1120 respectively, the method constructed in the experiment has the maximum fitness value, with values as high as 98.98% and 97.86%. When the training set is run, when the running time increases to 0.894s, the accuracy of the method constructed in the experiment to control mechanical noise reaches 91.68%. The application effect shows that when the material of the stator shell is steel, the occurrence of the maximum natural frequency of the stator is affected by the elastic modulus, which is far greater than the influence of the material density. The experiment provides new ideas and methods for noise and electromagnetic interference control of small DC electrodes.
PL
W artykule opisano przeanalizowany na drodze symulacji komputerowej proces relaksacji elektryzacji metalowego obiektu po zakłóceniu intencjonalnym impulsowym zaburzeniem elektromagnetycznym (EM). Oddziaływanie EM impulsu zaburzającego na metalowy obiekt powoduje przemieszczenie się swobodnych elektronów na jego powierzchni i elektryzację obiektu. W wyniku elektryzacji na powierzchni obiektu powstają obszary elektrycznie neutralne oraz obszary o różnej polarności elektrycznej. Proces elektryzacji oraz relaksacji obiektu analizowano na podstawie zmian składowej normalnej pola elektrycznego generowanego przez obszary elektrycznie naładowane na powierzchniach obiektu. Badania wykazują, że po ustaniu oddziaływania impulsu zaburzającego na obiekt istnieje regularność w zaniku składowej normalnej pola elektrycznego na powierzchni obiektu. Relaksacja elektryzacji obiektu trwa około 20 nanosekund i obejmuje przejście przez serię modów, zmniejszając stopniowo jego naelektryzowanie i przywracając neutralność elektryczną.
EN
The article describes the computer simulation-based analysis of the relaxation process of the electrification of a metallic object following intentional impulse electromagnetic (EM) disturbances. The interaction of the EM impulse disturbance with the metallic object causes the displacement of free electrons on its surface and electrification of the object. As a result of electrification, electrically neutral areas and areas of different electrical polarity are formed on the object's surface. The process of electrification and relaxation of the object was analyzed based on changes in the normal component of the electric field generated by the electrically charged areas on the object's surfaces. The research indicates that after the cessation of the disturbing impulse's interaction with the object, there is a regularity in the decay of the normal component of the electric field on the object's surface. The relaxation of the object's electrification takes about 20 nanoseconds and involves transitioning through a series of modes, gradually reducing its electrification and restoring electrical neutrality.
EN
The article presents issues related to the reliability of power supply for electronic security devices in intelligent buildings. These systems function under varied environmental conditions and are exposed to external or internal natural and artificial interference; lightning, in particular. The authors conducted actual experimental tests of two surge arresters that are used to protect against a lightning impulse. As a result of conducted tests, followed by reliability and operational modelling, it was concluded that their use in internal connection structures increased the probability of a system staying in a state of full fitness. All of the deliberations included in the article enabled developing a new method for assessing the power supply continuity in electronic security systems of intelligent buildings, taking into account external natural interference. This method can also be applied to assess the power supply continuity in other electronic systems and devices.
PL
W artykule pokazano po raz pierwszy, że intencjonalne impulsowe zaburzenie elektromagnetyczne (EM) może spowodować nie tylko zakłócenie elektromagnetyczne w wybranym obiekcie (lub obiektach) elektronicznym, ale oddziałuje ono również na środowisko elektromagnetyczne poprzez elektryzowanie napotykanych obiektów metalowych, które następnie stają się niepożądanymi źródłami pola elektromagnetycznego, w tym fal elektromagnetycznych w czasie i po przejściu intencjonalnego impulsowego zaburzenia EM. Generacja tych fal przez naelektryzowane obiekty metalowe jest rezultatem redystrybucji swobodnych elektronów w metalowych obiektach w czasie przemieszczania się intencjonalnego impulsowego zaburzenia EM przez te obiekty oraz relaksacji tej redystrybucji po przejściu tego zaburzenia. Relaksacja redystrybucji elektronów w obiektach metalowych trwa stosunkowo długo po przejściu EM impulsu zaburzającego, wytwarzając kolejne zaburzenie EM w postaci pola EM wokół obiektów. W niniejszej pracy demonstracja istnienia ubocznego wpływu intencjonalnego impulsu EM na środowisko elektromagnetyczne została wykonana za pomocą symulacji komputerowej przy użyciu programu obliczeniowego CST Studio.
EN
The article presents for the first time that an intentional (EM) electromagnetic interference pulse can not only cause an electromagnetic disturbance in a selected electronic object (or objects) but also interacts with the electromagnetic environment by electrifying encountered metal objects, which then become undesired sources of the electromagnetic field in the form of electromagnetic waves during and after the passage of intentional EM interference. The generation of this unwanted EM field by the electrified metal objects results from the redistribution of free electrons in the metal objects as the intentional pulsed EM passes through them, as well as the relaxation of this redistribution after the passage of the interference. The relaxation of electron redistribution in the metal objects lasts relatively long after the passage of the EM interference pulse, creating the subsequent EM interference in the form of the EM field around the encountered metal objects. In this study, the demonstration of the existence of the side effect of the interaction of intentional EM pulse with the electromagnetic environment was carried out by computer simulation using the CST Studio.
8
Content available Some aspects of electromagnetic field shielding
EN
The paper deals with the electromagnetic field shielding both at low and high frequency. At the low frequency the goal of shielding is to regulate the distribution of electromagnetic field in order to either minimizing the power losses in the iron (steel) parts of the device in question. The main practical aim of the shielding at the low frequency electromagnetic field is to avoid the state of overheating. At the high frequency the shielding is mainly dedicated to limit the radiation from the electromagnetic sources and the protection of electronic devices. In some extreme cases the shielding has to protect the humans against electromagnetic field.
PL
Artykuł dotyczy problematyki ekranowania pola elektromagnetycznego, zarówno dla niskich jak i wysokich częstotliwości. W problemach niskoczęstotliwościowych celem ekranowania jest właściwe sterowanie polem elektromagnetycznym w celu zminimalizowania strat energii w urządzeniu, co praktycznie sprowadza się do unikania stanu przegrzania elementów metalowych. W sytuacjach wysokoczęstotliwościowych ekranowanie ma na celu ograniczenie emisji pola elektromagnetycznego , a także ochrony urządzeń elektronicznych przed działaniem pola elektromagnetycznego. W sytuacjach ekstremalnych ochrona tak może dotyczyć ludzi.
EN
Most automotive electronic components can cause electromagnetic interference, that can cause power electronic circuits to become unstable. As per electromagnetic compatibility (EMC) standards, these electronic circuits should meet the specifications which are not achieved under some conditions. In this paper, the conducted emissions (CEs) are generated due to the switching of a buck converter, which often occurs in automotive electronics. The noise source was found to be due to the presence of common mode currents which largely affects the performance of EMC. Two types of filtering techniques were analysed and designed, and the results were compared to find an effective filtering solution to mitigate the effects of CE due to a common mode noise for the frequency range from 150 kHz to 108 MHz according to the International Special Committee on Radio Interference (CISPR25) standard. The capacitive and parasitic impedance were calculated and then used in the simulation. Finally, the simulated and measured results are presented. The noise level can be minimized by as much as 50 dB, which is an efficient noise reduction value.
EN
Advancement of the novel strengthening method improvement including electromagnetic interference (EMI) shielding and structural performance is of utmost importance and essential in reinforced concrete structures. The purpose of this study is to present a state-of-the-art review of methods used in the effective strengthening of conductive concrete and conductive grid-strengthened RC structures. There have been novel experiments into the development of conductive concrete that can be used as both an effective external load and EMI shielding. While most of the literature focuses on developing conductive concrete that is used in casting RC structures, a few researchers have focused on developing RC structures strengthening resistance to external loads and EMI. Using this conductive concrete to strengthen RC structures is insufficient and would require additional conductive grids. This paper reviews such novel strengthening materials that have been developed to shield against external loads and EMI. Numerous research claim that using one type of conductive material to improve the SE of reinforced concrete structures is insufficient and additional conductive materials are necessary. Shielding effectiveness values exceed the standard requirement only when using fully fabricated fiber-reinforced concrete strengthened by the metallic grid. Furthermore, the review emphasizes the type of conductive materials used in the RC structures strengthening to achieve adequate SE as described standards.
PL
W artykule przedstawiono zagadnienia związane z analizą niezawodnościowo-eksploatacyjną inteligentnych systemów transportowych. Są one eksploatowane w określonym środowisku transportowym. W artykule przedstawiono wyniki pomiarów pola magnetycznego emitowanego przez kable energetyczne dostarczające energię elektryczną na dworcu kolejowym do inteligentnych systemów transportowych. Zaprezentowana w artykule metodyka analizy niezawodnościowo-eksploatacyjnej inteligentnych systemów transportowych z uwzględnieniem zakłóceń elektromagnetycznych może być zastosowana podczas projektowania systemów elektronicznych użytkowanych w transporcie.
EN
The paper presents issues associated with the reliability-exploitation analysis of intelligent transportation systems (ITS) in rail transport. They operate in a defined transportation environment. The article presents the measurement results concerning a magnetic field emitted by electrical cables, which supply electricity to ITS stations at a train station. The reliability-operational analysis method which was shown in the paper, may be utilized when engineering electronic systems used in transport.
PL
W artykule przedstawiono wyniki symulacji numerycznej zależności skuteczności ekranowania wnętrza obudowy z otworem w funkcji częstotliwości od wyboru punktu obserwacji w tej obudowie. Analizę morfologii modów i zagrożenie EM, jakie stanowią we wnętrzu obudowy podzielono na dwie tematyczne sekcje. W pierwszej sekcji wyznaczono numerycznie częstotliwości rezonansowe i dokonano wizualizacji przestrzennej morfologii poszczególnych modów wewnątrz zamkniętej obudowy. W drugiej sekcji przeanalizowano zależność efektywności ekranowania od położenia punktu obserwacji wewnątrz obudowy z otworem. Wykonana symulacja wykazała, że efektywność ekranowania pola elektrycznego SEE jest funkcją miejsca w obudowie i częstotliwości. Spotykane w literaturze całościowe oceny skuteczności ekranowania na podstawie symulacji dla jednego punktu obserwacyjnego są zazwyczaj niemiarodajne.
EN
The article presents the results of a numerical simulation of the numerical simulation of the dependence of the shielding effectiveness inside the enclosure with aperture as a function of frequency on the selection of the observation point in this enclosure. The analysis of the morphology of the mods and the EM threat posed inside the enclosure are divided into two thematic sections. In the first section, the resonance frequencies were numerically determined and the spatial morphology of individual modes inside the closed enclosure was visualized. In the second section, the dependence of the shielding effectiveness on the position of the observation point inside the enclosure with aperture was analyzed. The simulation performed showed that the SEE is a function of the space in the casing and the frequency. The overall assessments of the shielding effectiveness based on simulations for one vantage point, found in the literature, are usually unreliable.
PL
Artykuł koncentruje się na dostępnych urządzeniach wykorzystywanych w sieciach sensorowych do badania parametrów życiowych człowieka, a także wiedzy dotyczącej sensorów i ich wrażliwości na zakłócenia elektromagnetyczne. Przedstawiono podstawowe pojęcia opisujące badaną problematykę, które pozwalają na jej zrozumienie. Dodatkowo wskazano na wymagania dotyczące implementacji sieci sensorowej według wymagań służb. Pozwoli to na zobrazowanie problematyki dotyczącej opracowania uniwersalnej sieci sensorowej podwyższającej bezpieczeństwo żołnierza na polu walki. Należy mieć również na uwadze, że przy docelowej implementacji konieczne będzie przeprowadzenie dodatkowych badań w utrudnionych warunkach ze względu na promieniowanie elektromagnetyczne.
EN
The article deals with the currently available devices used in sensor networks to examine human vital signs and the available knowledge about sensors and their sensitivity to electromagnetic interference. The article contains the basic concepts describing the studied issues that allow us to understand the being researched scientific field. In addition, it contains requirements for the implementation of the sensor network for the requirements of the services. This will allow you to illustrate the issues related to the development of a universal sensor network that increases the security of a soldier on the battlefield. It should also be borne in mind that with the final implementation it will also be necessary to carry out additional tests in difficult environments due to electromagnetic radiation.
EN
The paper presents issues associated with the impact of electromagnetic interference on track-side cabinets of a closed-circuit television system (CCTV) functioning in a railway transport environment. The measurements of an electromagnetic field emitted by a track-side CCTV cabinet were presented. Designs of this kind are operated in railway facilities; therefore, they should not disturb the functioning of other equipment, the rail traffic control systems, in particular (so-called inner compatibility). An analysis of the obtained results enabled developing a research model, and a further reliability and operational analysis, taking into account electromagnetic interference. This enabled determining a relationship allowing the determination of the probability of a track-side CCTV cabinet staying in a state of full ability. The presented discussions regarding a track-side CCTV cabinet, taking into account electromagnetic interference, allow for the numerical assessment of different types of solutions (technical and organizational), which can be implemented in order to mitigate the impact of electromagnetic interference on a system’s functioning.
PL
Zbadano zachowanie się bezzałogowych urządzeń latających w pobliżu dwutorowej linii najwyższego napięcia (400kV). Szczególny nacisk położono na wpływ generowanych przez linię zakłóceń elektromagnetycznych na pracę urządzeń pokładowych (czujniki, układy sterowania) oraz na jakość transmisji danych. Wykonane eksperymenty pokazały, że lot grupy dronów wzdłuż linii najwyższego napięcia jest możliwy, lecz należy uwzględnić pewne zakłócenia, które mogą zaburzać ich wzajemną komunikację.
EN
The operation of Unmanned Aerial Vehicles (UAVs) in the vicinity of the double extra high voltage (EHV) line (400kV) was investigated. We focused on the impact of the electromagnetic interference generated by the line on the operation of on-board devices (sensors, control systems) and on the quality of the data transmission. The performed experiments showed that the fly of the drones' group along the HV line is possible, but some noise of signals, which can disturb intercommunication, should be taken into account.
PL
W artykule opisano zakłócenia generowane przez zasilacze impulsowe energooszczędnych źródeł światła. Przeprowadzono pomiary zawartości harmonicznych prądu THDI oraz emisji zakłóceń przewodzonych i promieniowanych. Pomiarów dokonano dla pięciu różnych energooszczędnych źródeł światła i porównano je z żarówką halogenową o mocy 100 W.
XX
In the article has been described generated disturbances by switched-mode power supplies of energy-saving light sources. The current harmonics content, conducted interference and electromagnetic interference has been measured. Five different energy-saving light sources has been measured and compared with 100 W halogen bulb.
EN
In critical infrastructures like airports, much care has to be devoted in protecting radio communication networks from external electromagnetic interference. Protection of such mission-critical radio communication networks is usually tackled by exploiting radiogoniometers: at least three suitably deployed radiogoniometers, and a gateway gathering information from them, permit to monitor and localise sources of electromagnetic emissions that are not supposed to be present in the monitored area. Typically, radiogoniometers are connected to the gateway through relay nodes. As a result, some degree of fault-tolerance for the network of relay nodes is essential in order to offer a reliable monitoring. On the other hand, deployment of relay nodes is typically quite expensive. As a result, we have two conflicting requirements: minimise costs while guaranteeing a given fault-tolerance. In this paper, we address the problem of computing a deployment for relay nodes that minimises the overall cost while at the same time guaranteeing proper working of the network even when some of the relay nodes (up to a given maximum number) become faulty (fault-tolerance ). We show that, by means of a computation-intensive pre-processing on a HPC infrastructure, the above optimisation problem can be encoded as a 0/1 Linear Program, becoming suitable to be approached with standard Artificial Intelligence reasoners like MILP, PB-SAT, and SMT/OMT solvers. Our problem formulation enables us to present experimental results comparing the performance of these three solving technologies on a real case study of a relay node network deployment in areas of the Leonardo da Vinci Airport in Rome, Italy.
PL
Reaktory plazmowe to zaawansowane urządzenia służące do oczyszczania m.in. gazów. Wyładowania reaktora są źródłem zaburzeń elektromagnetycznych generowanych do systemu zasilania. W pracy przedstawiono wyniki badań przewodzonych zaburzeń elektromagnetycznych w torze zapłonu trójfazowego reaktora GlidArc. Przeprowadzono analizę emisji zaburzeń (w odniesieniu do wymagań EMC) przy kilku prędkościach przepływu gazu roboczego podawanego do komory wyładowczej.
EN
Plasma reactors are advanced devices used to purify, among others gases. The reactor discharges are the source of electromagnetic interferences generated to the power system. The paper presents the results of investigations of conducted electromagnetic interferences in the ignition circuit of the three-phase GlidArc reactor. The analysis of interferences emission (in relation to EMC requirements) at several flow rates of the working gas fed into the discharge chamber.
PL
W niniejszym artykule została przedstawiona analiza możliwości zastosowania pasywnych, aktywnych i hybrydowych filtrów EMI do tłumienia zaburzeń przewodzonych wspólnych generowanych przez falownik. Główny nacisk w prowadzonych badaniach kładzie się na aspekty techniczne i ekonomiczne, takie jak: cena filtru, masa, gabaryty oraz skuteczność tłumienia. W artykule porównano różne techniki tłumienia zaburzeń przewodzonych (za pomocą filtrów pasywnych, aktywnych i hybrydowych) wskazując ich zalety i wady.
EN
This article presents an analysis of the possibilities of using passive, active and hybrid EMI filters to reduce common mode noise generated by the frequency inverter. The main goal in the research is put on technical and economic aspects, such as: filter price, weight, dimensions and insertion losses. The article compares various techniques of reduction conducted noise (using passive, active and hybrid filters) indicating their advantages and disadvantages.
20
PL
Podstawowy obszar aplikacyjny termoanemometrów stanowią pomiary fluktuacji prędkości przepływu gazów w szerokim spektrum częstotliwości. Istotną cechą termoanemometrycznych systemów pomiarowych jest więc możliwie duże pasmo przenoszenia sygnału pomiarowego. Standardowo szerokie pasmo przenoszenia uzyskuje się poprzez zastosowanie stałotemperaturowego trybu pracy anemometru. W trybie tym temperatura grzanego elementu pomiarowego utrzymywana jest na stałym poziomie dzięki zastosowaniu układu elektronicznego ze sprzężeniem zwrotnym. Pasmo przenoszenia dla termoanemometrów stałotemperaturowych może sięgać setek kiloherców. Ponieważ czujnik termoanemometryczny stanowi pod względem elektrycznym rodzaj pętli indukcyjnej, mogą indukować się w nim zakłócenia elektromagnetyczne. Duże wzmocnienie oraz szerokie pasmo przenoszenia układu stałotemperaturowego powodują, że w przypadku występowania zakłóceń elektromagnetycznych udział sygnałów niepożądanych w sygnale wyjściowym termoanemometru może być znaczący. W pracy tej przedstawiono koncepcję metody eliminacji tych zakłóceń.
EN
The main application area for hot-wire anemometers are measurements of gas flow velocity fluctuations in a wide range frequency spectrum. An important feature of hot-wire anemometric measuring systems is therefore the highest possible frequency bandwidth of the measuring circuit. As a standard, a wide frequency response is obtained by using a constant temperature mode of the anemometer. In this mode, the temperature of the heated measuring element is kept constant, by the use of an electronic system with feedback. The frequency response for constant temperature anemometers can reach hundreds of kilohertz. Since the hot-wire sensor is a kind of induction loop in electrical terms, electromagnetic interference may be induced in it. The high gain and the wide frequency bandwidth of the constant temperature system mean that in the event of electromagnetic interference, the share of unwanted signals in the output signal of the anemometer can be significant. This work presents the concept of the method for eliminating these disturbances.
first rewind previous Strona / 5 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.