Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 182

Liczba wyników na stronie
first rewind previous Strona / 10 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  przepływ powietrza
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 10 next fast forward last
EN
Toxic smoke represents the most frequent cause of human fatalities in fire incidents. Therefore, it is crucial to design proper evacuation routes in buildings which one of the components are fire doors characterized by appropriate fire resistance and smoke containment classification. Achieving the required smoke containment class for fire doors primarily depends on effectively sealing gaps between movable door leaves, frames, and thresholds. For threshold edges, the most common solutions involve either special drop-down seals or properly profiled thresholds equipped with compression gaskets. In both cases, installation precision is paramount. The purpose of this study was to analyze the impact of threshold solution type and gap widths between door leaves, frames, and thresholds on door smoke containment performance.
PL
Toksyczny dym jest najczęstszą przyczyną śmierci ludzi w przypadku wystąpienia pożaru. Bardzo istotne jest więc zaprojektowanie w budynku odpowiednich dróg ewakuacyjnych, których jednym ze składowych elementów są drzwi przeciwpożarowe, charakteryzujące się odpowiednią odpornością ogniową i klasą dymoszczelności. W celu osiągnięcia odpowiedniej klasy dymoszczelności drzwi przeciwpożarowych najistotniejsze jest zabezpieczenie szczelin pomiędzy ruchomymi elementami skrzydła a ościeżnicą oraz progiem. W przypadku krawędzi progowej najczęściej stosowane rozwiązania polegają na zastosowaniu specjalnej uszczelki opadającej lub na wykonaniu odpowiednio wyprofilowanego progu wyposażonego w uszczelkę dociskową. W obu przypadkach ogromne znaczenie ma dokładność montażu. Celem zaprezentowanych badań było przeanalizowanie wpływu rodzaju zastosowanego rozwiązania progowego oraz szerokości szczelin pomiędzy skrzydłem a ościeżnicą i progiem na dymoszczelność drzwi.
EN
During the mining of a single coal seam isolated island work surface with large burial depth, the high mine pressures can crush and break the protective coal pillars, causing serious air leakages in the rear goaf. Herein, we use the analytic hierarchy process(AHP) to determine the main influencing factors of air leakage in island mining face. The air leakage source and sink in goaf were determined by measuring the differential pressures between the island mining face and the adjacent goaf using the energy level measurement method. The air volumes in the roadways were monitored on site to quantitatively analyze the specific changes of the air leakage in the isolated island work surface. Finally, the air leakage prevention measures were evaluated for the air leakage reduction efficiency in the island mining face and the goaf. Research shows that: (1) The fissure development in the roadway wall is the main influencing element of the air leakage in the isolated island work surface; (2) The differential pressure causes the air leakage volume of 37-40 m3/ min from the goaf to the island mining face; (3) Shotcrete in the gob-side roadway of the isolated island work surface can reduce the air leakage by 78%.
5
EN
The subject of this article's review is air distribution within a group of rooms (a model of groups of rooms is given in the article). For this group of premises, it is necessary to distribute air that will meet modern comfort requirements (temperature gradient, volume of supplied air, absence of noise and vibration), and also maintain the aesthetic architectural integrity of the premises. In order to ensure the necessary indoor climate parameters, it is necessary to provide a list existing ventilation schemes, conduct a review and comparative analysis of air distribution schemes and, in particular, ventilation ducts, diffusers, supply and exhaust grilles with different lengths and jet flow paths. The use of air distributors when designing ventilation that performs the distribution task of moving oxygen volumes, thereby creating circulation of air space in the work area. To avoid the presence of stagnant zones and uneven distribution of the temperature gradient, the best option, both for the conference room and the CD center, and for most of the teaching staff, is turbulent air distribution. At the same time, most of the air distributors considered are, for one reason or another, not suitable for use in this project.
EN
Machining difficult-to-cut materials involves challenging machining conditions, including higher temperatures in the cutting zone, cutting forces and friction. Another important phenomenon is vibration, which is undesirable when manufacturing high quality workpieces. One way to reduce vibration in the cutting zone is to use cooling methods. Due to its environmentally friendly nature, the minimum quantity lubrication (MQL) method has already been widely used in metalworking. However, when combined with nanofluids, it improves the ability of the aerosol to dissipate more heat and increase lubrication in the cutting zone. This paper presents the effect of a polyol ester-based Al2O3 nanofluid due to the varying mass concentration of nanoparticles on the vibration during turning of Ti6Al4V alloy and compares the results with dry cutting and the MQL method without nanoparticles. Four concentrations (0.25−1 wt%), variable nanofluid flow rate E = 0.388−1.182 g/min and air flow rate P = 10−40 l/min were considered. According to the statistical analysis, the most important factor influencing tool vibration was the mass concentration of nanoparticles in the cutting fluid. By combining the MQL method with 0.5 wt% Al2O3, the vibration acceleration RMS values were found to be the lowest. When compared to the MQL method without nanoparticles, the RMS values for dry cutting ranged from 17.8% to 24.9%, and for wet cutting they were reduced by about 10.9-18.5%.
7
Content available remote Szczeliny wentylacyjne w dachach mansardowych
8
Content available remote Przykład wykonania dachu wentylowanego
EN
The paper presents the results of research on the kinetics of the binding process of self-hardening moulding sands with an organic binder under conditions of forced air flow at various pressure values. Three moulding sands made using urea-furfuryl resin Furanol FR75A technology were studied. The moulding sands were prepared on a base of quartz sand with an average grain size of dL = 0.25, 0.29 and 0.37 mm, with permeability values of 306, 391 and 476 m2108Pa x s (for ρo = 1.60, 1.60 and 1.61 g/cm3 , respectively). The research was conducted for a resin content of 1% with a constant proportion of hardener to resin, which was equal to 50%. Samples of the tested moulding sands were blown with air at pressures of 0.1, 0.2, 0.4, 0.6, 0.8, and 1.0 bar. The kinetics of the hardening process was monitored using ultrasound technology, according to a previously developed methodology [1]. The research was carried out on an ultrasound testing station equipped with a temperature chamber and an airflow reducer. The tests were conducted at a temperature of 20°C, and of the air flow pressure on the changes in ultrasonic wave velocity in the hardening mouldins sand as a function of time, the kinetics of the hardening process, and the degree of moulding sand hardening were determined. Additionally, the influence of the moulding sand permeability on the course of the hardening process at a constant air flow pressure was determined.
10
Content available Building ventilation across history – examples
EN
Various cases from history indicate that the chimney is an important architectural detail in a building. Its shape, size and place where it rises above the roof affect the outline of a building and can even testify to the wealth of the family that inhabits it, as was the case in Portugal, among others. However, a chimney sometimes transforms from an architectural detail into a dominant element, which is not beneficial to the building’s overall massing. At present, ventilation is not only based on the design of ventilation ducts, but also on a comprehensive approach to design that affects the shaping of a building’s massing.
PL
Różne przykłady z historii świadczą o tym, że komin jest ważnym detalem architektonicznym budynku. Jego kształt, wielkość, miejsce wyprowadzenia ponad dach istotnie wpływają na sylwetę obiektu architektonicznego, a nawet świadczy o zamożności rodu zamieszkującego budowlę tak, jak to miało miejsce np. w Portugalii. Czasem jednak z detalu architektonicznego komin przeradza się w element będący dominantą, co nie jest korzystne dla całej bryły budynku. Obecnie wentylacja nie tylko polega na zaprojektowaniu przewodów wentylacyjnych ale również na kompleksowym podejściu do projektowania, mając wpływ na kształtowanie bryły obiektu.
PL
Dyrektywy Unii Europejskiej oraz przepisy krajowe wyraźnie wskazują na rozwój budownictwa niemal zeroenergetycznego i o niskiej emisji ditlenku węgla. Artykuł zawiera informacje o tym, jakie komponenty budynków na to wpływają i jak to osiągnąć. Energia w budynku jest zużywana w czasie jego wznoszenia - tzw. energia wbudowana i w czasie długoletniej eksploatacji. Na parametry energetyczne i ekologiczne wpływają głównie podstawowe komponenty: obudowa budynku i jej właściwości termiczne, szczelność, efektywne techniczne wyposażenie oraz źródła energii i sposób konwersji energii. Wszystkie te komponenty mają wpływ na wskaźnik nieodnawialnej energii pierwotnej i wskaźnik emisji ditlenku węgla. Pokazano przykładowe rozwiązania techniczne zapewniające te niskie parametry. Proponowany kierunek działania jest niezbędny dla przyszłości, aby spełnić wymagania niskiej emisji CO2 oraz wzrostu wykorzystania energii odnawialnej w budownictwie.
EN
European Union directives and national regulations clearly indicate the development of nearly zero-energy and low-carbon construction. The article provides information on what building components affect this and how to achieve it. The energy in the building is consumed during its erection - the so called embodied energy and long-term operational energy. The energy and ecological parameters are mainly influenced by the basic components: the building envelope and its thermal properties and tightness, efficient building services as well as energy sources and the method of energy conversion. All these components have an impact on the non-renewable primary energy index and the carbon dioxine emission factor. Examples of technical solutions ensuring these low parameters are shown. The proposed direction of action is necessary for the future to meet the requirements of low carbon dioxide emissions and the increase in the use of renewable energy in construction.
PL
W artykule przedstawiono studium przypadku ilustrujące typowe problemy użytkowników starszych domów jednorodzinnych w aspekcie pracy tradycyjnej wentylacji grawitacyjnej. Na podstawie przeprowadzonych badań stwierdzono, że przyczyną powstawania tzw. wstecznych ciągów, oprócz czynników pogodowych, może być wpływ urządzeń mechanicznych wymuszających ciąg w przewodach wentylacyjnych (okap kuchenny) lub dymowych (dmuchawa kotła c.o.). Zwrócono również uwagę na potrzebę częstych przeglądów skuteczności wentylacji, aby wyeliminować pewne prozaiczne powody jej nieskuteczności.
EN
The article presents a case study illustrating typical problems of users of older single-family houses in the aspect of traditional gravitational ventilation. Based on the conducted research, it was found that the cause of the so-called backdrafts, apart from weather factors, may be caused by the influence of mechanical devices forcing draft in ventilation ducts (kitchen hood) or smoke ducts (central heating boiler blower). Attention was also drawn to the need for frequent reviews of the effectiveness of ventilation to eliminate some prosaic reasons for its ineffectiveness.
13
Content available remote Przypadek kontrłaty a stan wiedzy o dachach
14
Content available remote MWK i szczelność powietrzna budynków
15
Content available remote Degradacja MWK
EN
The airflow field pattern in the condensing zone plays a vital role in the pneumatic compact spinning, which significantly affects the yarn's qualities. This study aimed to analyze the effects of the different negative air pressures on fiber condensing in compact spinning with lattice apron using ANSYS. The results of airflow simulations reveal that by increasing the negative pressure, the flow velocity increases, leading to a more tremendous increase in the transverse condensing effects. Additionally, a better convergence led to reduced fiber width and eliminated the spinning triangle. Experimental results showed that the three yarns spun with the highest negative pressure had better strength, hairiness, and evenness than those spun with lower negative pressure.
EN
COVID-19 is constantly spreading around the world. Doctors, nurses and medical staff spend more time providing their professional help than usual. It is especially important to provide them with a suitable working environment. Therefore, in the following article we will deal with the design of a computational model of a laminar field in a clean room using CFD methods.
PL
COVID-19 nieustannie rozprzestrzenia się w świecie. Lekarze, pielęgniarki i personel medyczny spędzają więcej czasu niż zwykle niosąc profesjonalną pomoc. Jest zatem szczególnie istotne, aby zapewnić im odpowiednie środowisko pracy. Dlatego też w prezentowanym artykule zajęto się zaprojektowaniem modelu komputerowego pola laminarnego w czystym pomieszczeniu z wykorzystaniem metod CFD.
18
Content available remote Zalety dachów wentylowanych
first rewind previous Strona / 10 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.