Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 10

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  ventilated façade
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Nevertheless, no comprehensive studies have been conducted thus far to evaluate the influence of environmental factors on the mechanical performance of sandstones quarried and used as façade materials in Poland. Experimental investigations carried out on sandstones from Śmiłów, Żerkowice, and Skała, extracted from existing building façades, revealed substantial degradation in their mechanical strength. The findings also highlighted deficiencies in current evaluation protocols for natural stone materials intended for use in ventilated façade systems. Petrographic and microscopic analyses demonstrated that the loss of structural integrity in the examined sandstones is primarily due to the development of multidirectional microcracks propagating through mineral grains, and, in near‑surface zones, the breakdown of grain‑to‑grain contacts leading to granular disintegration. These deterioration mechanisms were initiated and accelerated by repeated freeze‑thaw cycles associated with the infiltration of meteoric water. The ingress of water was facilitated by the high total porosity of the material, exceeding 20%, as well as by the presence of an interconnected pore network, which significantly enhanced water permeability and retention within the stone matrix.
PL
Dotychczas nie przeprowadzono badań wpływu środowiska na parametry wytrzymałościowe piaskowców wydobywanych i stosowanych na elewacje w Polsce. Wyniki badań piaskowców Śmiłów, Żerkowice i Skała, pochodzących z elewacji budynków, wykazały znaczne zmniejszenie ich wytrzymałości na zginanie oraz braki w stosowanych metodach weryfikacji materiałów kamiennych, stanowiących podstawę do ich stosowania jako materiału okładzinowego w elewacjach wentylowanych. Badania mikroskopowe wykazały, że powodem obniżenia zwięzłości piaskowców jest powstanie w ich wnętrzu wielokierunkowych spękań obejmujących ziarna, a w ich zewnętrznej części, zerwanie połączeń między ziarnami i ich wykruszanie się. Zmiany te zostały wywołane cyklicznym zamarzaniem i rozmarzaniem wody pochodzącej z opadów atmosferycznych. Jej wnikaniu w głąb kamieni sprzyjała ich znaczna porowatość, wynosząca ponad 20% oraz system połączonych porów.
EN
The trend of recent years is the use of a building information model (BIM) in the early design stages. This procedure positively affects the entire life cycle of a building, especially its construction and operation, during which the largest percentage of financial and energy resources are spent. The consumption rate of these resources is directly influenced by the architectural design of the building, from shape solutions to structural and material characteristics of passive systems. One of them is a multilayered external envelope with a ventilated gap, which reduces heat gains during the summer and better accumulates heat from solar radiation during the winter. The fact is that the internal climate in the gap is different from the external environment and is influenced mainly by the external temperature, air flow speed, sunlight intensity, material on the external and internal facade and shading from surrounding buildings. The aim of the work is to develop a simulation tool that will lead to a more efficient design of the shape of the building envelope with a ventilated gap. The tool will simulate the impact of solar radiation on the facade at a certain day and hour of the year, shading from surrounding buildings and materials on the external surface and their influence on the temperature course in the ventilated gap. This simulation will run dynamically on the background of the architectural design and will support the decisionmaking process. This could subsequently lead to savings in the total energy consumed for heating and cooling the building
EN
This article discusses the development of ventilated facades with passive brackets. A key element of any ventilated facade is the substructure, which is responsible for the mechanical properties of the facade systems, safety of use, and thermal insulation characteristics. Passive brackets in ventilated facades help minimize the negative impact of thermal bridges on the building envelope. However, the use of polymer insulators can significantly affect the mechanical properties, usability, and safety of buildings. The article analyses the issues associated with the application of passive brackets with polymer insulators in facade systems based on the collected research results. The conducted analysis indicates the need for further refinement and adaptation of research methods and techniques to the specifics of innovative passive brackets in order to gain a deeper understanding of their technical and usability properties, particularly in the context of their durability and load-bearing capacity.
PL
Artykuł dotyczy problematyki rozwoju elewacji wentylowanych z konsolami pasywnymi. Kluczowym elementem każdej elewacji wentylowanej jest podkonstrukcja. Odpowiada ona za właściwości mechaniczne systemów elewacyjnych, bezpieczeństwo użytkowania oraz właściwości termoizolacyjne. Pasywne konsole w elewacjach wentylowanych pozwalają zminimalizować negatywny wpływ mostków cieplnych na przegrodę, ale zastosowanie polimerowych izolatorów może mieć duży wpływ na właściwości mechaniczne, użytkowe oraz bezpieczeństwo użytkowania obiektów budowlanych. W artykule, na podstawie wyników badań, przeanalizowano problemy stosowania podkonstrukcji pasywnych z polimerowymi izolatorami w systemach elewacyjnych. Przeprowadzona analiza wskazuje na potrzebę dalszego doskonalenia i dostosowania metod i technik badawczych do specyfiki innowacyjnych konsoli pasywnych w celu dokładniejszego poznania ich właściwości techniczno-użytkowych, szczególnie w kontekście ich trwałości i nośności.
4
Content available Modernizacja elewacji wentylowanych
PL
Elewacje wentylowane należą do grupy najczęściej stosowanych rozwiązań elewacyjnych. Podczas użytkowania, jak każdy inny wyrób budowlany, ulegają degradacji i uszkodzeniom. Wraz z pogorszeniem stanu technicznego elewacji wentylowanej właściciel obiektu budowlanego musi podjąć decyzję dotyczącą jej dalszego losu: czy elewacja wentylowana może być naprawiona czy też wymaga demontażu? W artykule omówiono decydujące czynniki techniczno-użytkowe mające wpływ na zakwalifikowanie elewacji wentylowanej do dalszego użytkowania, naprawy lub rozbiórki.
EN
Ventilated facades belong to the group of the most commonly used facade solutions. During use, like any other construction product, they degrade and become damaged. With the deterioration of the technical condition of the ventilated facade, the owner of the building is to decide on its further fate: can the ventilated facade be repaired or does it require disassembly? The article discusses the decisive technical and operational factors affecting the qualification of a ventilated facade for further use, repair or demolition.
PL
Z doświadczenia eksperckiego ITB wynika, że w elewacjach wentylowanych połączenie „okładzina - łącznik mechaniczny - profil podkonstrukcji” charakteryzuje się dużą awaryjnością. Jedną z najczęstszych przyczyn uszkodzeń jest nieuwzględnienie zmian właściwości mechanicznych połączeń zachodzących wskutek oddziaływań klimatycznych. Na podstawie przeprowadzonych badań laboratoryjnych udowodniono, że zmniejszenie odporności na wyrywanie łączników mechanicznych z okładzin włóknisto-cementowych po oddziaływaniach klimatycznych może wynosić 40% w stosunku do wartości początkowej. Znajomość rzeczywistego poziomu zmiany tego parametru jest konieczna do zaprojektowania trwałej i bezpiecznej elewacji wentylowanej.
EN
The ITB expert experience shows that in ventilated facades, the join "cladding - mechanical connector - substructure profile" is characterized by a high failure rate. One of the common causes of damage is failure to take into account changes in the mechanical properties of joints due to climatic effects. Based on the conducted laboratory tests, it was proved that the drop in the resistance to tearing mechanical fasteners from fibercement linings after climatic influences may be 40% compared to the initial value. Knowledge about the real level of changes in the pull-out resistance of the connection "cladding - mechanical connector - substructure profile" after climatic influences is necessary to design a durable and safe ventilated facade.
6
Content available remote Wizualne zmiany na elewacjach wentylowanych z okładzinami włóknisto-cementowymi
PL
Podczas eksploatacji elewacji wentylowanych z okładzinami z płyt włóknisto-cementowych często uwidoczniają się zmiany w postaci przebarwień i w wielu przypadkach towarzyszą im deformacje okładzin. Czy zmiany te mają charakter wyłącznie estetyczny i czy wpływają na właściwości użytkowe systemu elewacyjnego? Przeprowadzone badania laboratoryjne dają podstawy do stwierdzenia, że wraz ze zmianami wizualnymi zachodzą zmiany strukturalne oraz wytrzymałościowe w okładzinach, które mogą mieć istotny wpływ na właściwości techniczno-użytkowe systemów elewacyjnych, w tym bezpieczeństwa użytkowania.
EN
During the exploitation on fiber-cement cladings of ventilated facades systems sometimes are visible changes in the form of discoloration. Discoloration is often accompanied by deformation of the cladding. Are these changes aesthetic and do they also have an impact on the performance properties of the façade system? The laboratory tests give grounds to state that along with the visual changes, structural and strength changes in the claddings occur which changes may have a significant impact on the technical and operational properties of facade systems, including the safety of use.
PL
W artykule przedstawiono zakres oceny technicznej właściwości mechanicznych elewacji wentylowanych z okładzinami kamiennymi z niewidocznym mocowaniem do rusztu.
EN
The article presents the scope of the technical assessment of mechanical properties of ventilated façades with stone cladding fixed to the foundation with concealed fixing.
EN
The paper examines the impact of possible operational factors on strength and frequency parameters generated by bending of fibre-cement panels. The tests were performed on elements cut out of a standard commercially available panel. The samples were exposed to factors described as environmental (soaking in water, bath-drying cycles, freeze-thawing cycles) and unique (flame ignition and high temperature exposure) and then subjected to three-point bending tests. Acoustic emission (AE) signals were acquired during the external load application. After the measurements were completed, the strength of individual elements was determined and the frequencies generated during bending were calculated. The obtained results were analysed statistically. Comparing the results obtained for a group of samples subjected to environmental and unique factors, significant differences between them were noted. It was noted that the decrease in the strength of the samples is related to the emission of lower frequency sounds. It was found that the application of the presented methodology allows to determine the condition of the fibre-cement boards in use.
PL
W artykule przedstawiono wyniki testów trzypunktowego zginania dla elementów włóknisto-cementowych poddanych działaniu czynników środowiskowych i wyjątkowych z jednoczesną akwizycją sygnałów AE. Analizie poddano wartości wytrzymałości na zginanie oraz częstotliwości generowanych przed momentem zniszczenia. Na podstawie otrzymanych wyników wyciągnięto następujące wnioski: Obniżenie wytrzymałości elementów włóknisto-cementowych wiąże się z generowaniem niższych częstotliwości przy zginaniu w odniesieniu do próbek o niezmienionych parametrach mechanicznych. Zastosowanie metody emisji akustycznej umożliwia śledzenie częstotliwości powiązanych z powstawaniem różnego rodzaju zmian w strukturze materiału. Przebieg procesu niszczenia struktury płyty cementowo-włóknistej jest mechanizmem złożonym i powiązanym w sposób ścisły z obecnością włókien zbrojących oraz stopniem wiązania pomiędzy zbrojeniem a matrycą. Częstotliwości generowane przez zmiany zachodzące w strukturze włókno-cementu są ściśle powiązane z obecnością zbrojenia w postaci włókien oraz stopniem wiązania między zbrojeniem a matrycą. Zastosowanie techniki emisji akustycznej umożliwia skuteczne wykrywanie i monitorowanie inicjacji zmian w strukturze wpływających na obniżenie parametrów mechanicznych płyt. Otrzymane rezultaty dają możliwość zastosowania metody AE do oceny stanu pełnowymiarowych elementach cementowo-włóknistych.
9
Content available remote Elewacje wentylowane - porównanie numeryczne w zakresie termicznym
PL
W artykule porównano elewację standardową z elewacjami wentylowanymi w dwóch wariantach: zamkniętych i otwartych złączy. Porównania dokonano za pomocą symulacji numerycznych CFD. Założenia środowiska zewnętrznego do obliczeń oparto o Eurokod, zakładając najbardziej niekorzystne warunki dla Polski w zakresie wysokich temperatur i dużego nasłonecznienia. Wyniki wykazały pozytywne rezultaty ze stosowania elewacji wentylowanych. Wybór wariantu technologicznego elewacji w zakresie zamkniętych lub otwartych złączy ma minimalny wpływ na efektywność termiczną całej przegrody.
EN
The article compares standard façade with ventilated façades in two variants: with closed and open connectors. The comparison has been made by means of the CFD numerical simulations. External environment assumptions for the purposes of the calculations have been made on the basis of Eurocode, considering the most unfavorable conditions for Poland in terms of high temperatures and high solar radiation. The results showed positive benefits of using ventilated façades. The choice of technological variants of ventilated façades (closed or open connector) has minimum impact on thermal efficiency of the entire partition.
10
Content available remote Elewacja wentylowana podczas oddziaływania pożarem
PL
Elewacje wentylowane stają się coraz popularniejszym rozwiązaniem elementu zewnętrznego, osłonowego ściany zewnętrznej w budownictwie. Niestety w niektórych aspektach nie są one jeszcze dobrze ustandaryzowanie i zbadane. W przypadku elewacji wentylowanych główny problem w zakresie bezpieczeństwa stanowi możliwe odpadanie części okładzin w trakcie oddziaływania pożarem. Niestety przepisy nie podają rodzajów badań oraz oceny takich elementów. Na potrzeby artykuły wykonano badania doświadczalne na modelu elewacji w skali naturalnej, z dwoma rodzajami okładzin elewacyjnych zewnętrznych. Materiałami wykorzystanymi jako okładzina zewnętrzna były płyty włóknisto-cementowe i spieki ceramiczne. Model elewacji wyposażono w termopary. Materiały okładzinowe wykazały różne zachowanie się podczas badania.
EN
Ventilated façades are becoming an increasingly popular solution for external walls in the construction. Unfortunately, in some aspects they are not yet well standardized and tested. The main safety problem of ventilated façade is the possible falling off of claddings parts under the influence of fire. Unfortunately, legislation does not provide the types of tests and assessment of these components. For the purposes of this paper, experimental tests have been conducted using a façade model in the natural scale, with two types of external claddings. The materials used as external cladding were fibre cement boards and big slab ceramic tiles. The façade model was equipped with thermocouples. Cladding materials showed different behaviour during the test.
first rewind previous Strona / 1 next fast forward last