Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  generator synchroniczny
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 7 next fast forward last
EN
This paper presents a sensitivity analysis of the synchronous generator non-integer order model parameters for SSFR (Standstill Frequency Response) identification. The equivalent circuits of the generator, comprising 10 parameters in the d-axis and 7 parameters in the q-axis, were prepared for a 3 kVA and a 125 kVA synchronous machines. Then, an analysis of the model fitting errors to the measured SSFR characteristics was performed for the changing with saturation selected parameters of the non-integer order model.
PL
Artykuł przedstawia analizę wrażliwości parametrów modelu rzędu niecałkowitego generatora synchronicznego do celów identyfikacji metodą SSFR (StandStill Frequency Response). Obwodowy schemat zastępczy generatora zawierający 10 parametrów w osi d oraz 7 parametrów w osi q został przygotowany dla maszyn synchronicznych o mocy 3 kVA i 125 kVA. Następnie przeprowadzono analizę błędów dopasowania modeli do zmierzonych charakterystyk SSFR dla zmieniających się wraz z nasyceniem wybranych parametrów modelu rzędu niecałkowitego.
EN
This article presents various methods for calculating frequency deviations in response to changes in parameters affecting the operation of the power system, such as load, power flows, distributed generation, and inertia. The paper also includes a comprehensive analysis of frequency disturbance tests conducted under different scenarios, evaluating the performance and response of power system protection mechanisms. By studying the impact of these disturbances on system stability and the operation of protective devices, the paper provides insights into the critical role of Rate of Change of Frequency (ROCOF) calculation in ensuring the reliability and resilience of electrical grids. The findings highlight the importance of accurate ROCOF calculations and robust protection schemes to mitigate potential system failures.
PL
W artykule przedstawiono różne metody obliczania zmian częstotliwości w odpowiedzi na zmiany parametrów wpływających na pracę systemu elektroenergetycznego, takich jak obciążenie, przepływy mocy, generacja rozproszona i inercja. Artykuł zawiera również kompleksową analizę testów zaburzeń częstotliwości przeprowadzonych w różnych scenariuszach, oceniających wydajność i reakcję zabezpieczeń częstotliwościowych. Badając wpływ tych zakłóceń na stabilność systemu i działanie urządzeń zabezpieczających, artykuł dostarcza wglądu w krytyczną rolę obliczeń szybkości zmian częstotliwości w czasie (ROCOF) w zapewnianiu niezawodności pracy systemu elektroenergetycznego. Wyniki badań podkreślają znaczenie dokładnych obliczeń ROCOF i stosowania pewnych zabezpieczeń częstotliwościowych w celu złagodzenia potencjalnych awarii systemowych.
PL
W artykule przedstawiono referaty zaprezentowane w ramach Komitetu Studiów A1 CIGRE. Referaty podzielone były formalnie na trzy grupy tematów preferowanych PS (preferred subjects), choć zdaniem autora podział był dość umowny. Referaty starały się podążać za bieżącą sytuacją w energetyce związaną z transformacją energetyczną. Wyraźnie dało się zauważyć duże zainteresowanie kompensatorami synchronicznymi, które są optymalną metodą zapewnienia regulacyjności napięcia i mocy biernej, zapewnienia mocy zwarciowej i inercji w systemach elektroenergetycznych przyszłości. Bardzo ciekawy jest referat prezentujący możliwości współczesnego bloku jądrowego. W kilku referatach przedstawiono współczesne rozwiązania hydrogeneratorów, w tym pracujących ze zmienną prędkością obrotową. Godny polecenia jest referat opisujący doświadczenia włoskiego OSD w zakresie eksploatacji kół zamachowych współpracujących z kompensatorami synchronicznymi. Autor przedstawił 29 referatów zaprezentowanych na sesji, starając się omówić wynikające z nich wnioski oraz w sposób skrócony ich zawartość.
EN
The article presents papers of the A1 committee, during the Paris CIGRE session. The papers were formally divided into three groups of preferred subjects PS, although, according to the author, the division was quite fuzzy. The papers tried to follow the current situation in the energy sector related to the Energy Transition. There was a lot of interest in Synchronous Condensers SC which are optimal solutions for control of the voltage and reactive power, ensure short circuit power and inertia in the power systems of the future. The paper presenting the possibilities of a modern nuclear unit is very interesting. Several papers present modern solutions for hydrogenerators, including variable speed motor generators. Worth recommending is a paper describing the experience of the Italian DSO in the field of flywheel cooperating with SC maintenance, is especially worth recommending. The author presented all 29 papers presented at the session, trying to present the resulting conclusions and their content.
EN
Non-integer order modelling is used for a better description of different natural physical phenomena, which leads to more compact and knowledge-based models. The main objective of the presented study is to apply the non-integer order model of a synchronous generator (SG) in the power hardware-in-the-loop (PHIL) technique, which is readily used for design, research and development, maintenance, or service purposes. The developed model was prepared and run in the MATLAB/Simulink software using a discrete solver. To discretize the non-integer order model, the Z-transform was applied and the half-order derivatives and integrals present in the model equations were evaluated using Oustaloup approximation. Finally, the model was validated on the measurements of the 125 kVA SG connected to the active-reactive loads of different values and compared with the classical integer order one.
PL
W artykule opisano zagadnienia techniczne związane z eksploatacją zabezpieczeń częstotliwościowych. Zbadano wpływ różnych parametrów charakteryzujących konstrukcję źródeł energii na zmiany częstotliwości generowanego napięcia. Na podstawie przeprowadzonych analiz teoretycznych i symulacji zebrano dane, które następnie wykorzystano w badaniach laboratoryjnych przekaźnika zabezpieczeniowego, wyposażonego w kryteria nad- i podczęstotliwościowe oraz kryterium df/dt. Ustalono wpływ zarówno samych nastaw zabezpieczeń, jak i parametrów źródeł na skuteczność działania zabezpieczeń częstotliwościowych
EN
The article describes technical issues related to the operation of frequency protection. The impact of various parameters characterizing the structure of energy sources on changes in the frequency of the generated voltage was examined. Based on theoretical analyses and simulations the data were collected. In the next step obtained data were used in laboratory tests of a protection relay, equipped with over- and under-frequency criteria and the df/dt criterion. Moreover, the influence of the protection settings and the parameters of the distributed energy sources on the effectiveness of the operation of frequency protection was determined.
EN
This paper proposes the usage of the wavelet coherence to analyse the phenomenon of the loss of synchronism by a synchronous generator due to a short-circuit in the transmission electrical power network. On the basis of the simulation studies and the use of the wavelet coherence, the relationships between various electrical and mechanical quantities were investigated.
PL
Artykuł proponuje wykorzystanie koherencji falkowej do analizy zjawiska utraty synchronizmu przez generator synchroniczny na skutek wystąpienia zwarcia w sieci przesyłowej. Na podstawie badań symulacyjnych oraz użycia koherencji falkowej zbadano związki pomiędzy różnymi wielkościami elektrycznymi i mechanicznymi.
EN
This paper presents a comparative analysis of the impact of the forced excitation coefficients of two different excitation control systems of large synchronous generators on the transient stability of electric power systems. The analysis is based on the mathematical model of the synchronous generator of the seventh order based on Park’s transformations and a simplified and sufficiently accurate model of excitation control systems. The model simulates the operation of the generator unit as a one-machine system connected to the infinite bus through a double transmission line during a normal operating regime followed by a short circuit fault disturbance causing challenging the transient stability of the system.
PL
W artykule przedstawiono analizę porównawczą wpływu współczynników wzbudzenia wymuszonego dwóch różnych układów regulacji wzbudzenia dużych generatorów synchronicznych na stabilność przejściową systemów elektroenergetycznych. Do analizy wykorzystano model matematyczny generatora synchronicznego siódmego rzędu oparty na transformacjach Parka oraz uproszczony i wystarczająco dokładny model układów sterowania wzbudzeniem. Model symuluje pracę agregatu prądotwórczego jako systemu składającego się z jednej maszyny podłączonej do nieskończonej magistrali za pośrednictwem podwójnej linii przesyłowej podczas normalnego trybu pracy, po którym następuje zakłócenie zwarciowe, powodujące wyzwanie dla przejściowej stabilności systemu.
EN
The automatic circuit recloser (ACR) plays an essential role in the operation of not only the transmission, but also the distribution systems, where it helps to restore normal system operation after a failure, the correct setting of which is very important, especially in terms of transient stability of generators and power system stability as a whole. In this paper, we deal with the correct setting of the ACR cycle based on data from the real operation of the power system and its incorporation into the operational management of the power system.
PL
Automatyczny reklozer (ACR) pełni istotną rolę w pracy nie tylko przekładni, ale również systemów rozdzielczych, gdzie pomaga przywrócić normalną pracę systemu po awarii, której prawidłowe ustawienie jest bardzo ważne, zwłaszcza w zakresie stabilności przejściowej generatorów i stabilności systemu elektroenergetycznego en bloc. W niniejszym artykule zajmujemy się prawidłowym ustawieniem cyklu ACR na podstawie danych z rzeczywistej pracy systemu elektroenergetycznego i jego włączeniem do zarządzania operacyjnego systemem elektroenergetycznym.
EN
At present time, the task of studying the operating conditions of synchronous generators operating in parallel with the power system taking into account the introduction of new capacities in the system and increasing their stability provokes interest for research. An effective mean of the stability of power plants, as part of the power system, is automatic excitation control. The simulation environment MATLAB / Simulink is widely used in the calculation and analysis of normal steady-state and transient conditions of electrical systems. The article presents the results of the study and the comparison of operating parameters on the example of the Nurek hydropower plant. The results obtained will be useful in studying the use of modern types of AEC in the excitation system of the generators of Nurek HPP.
PL
Skutecznym środkiem stabilności elektrowni, jako części systemu elektroenergetycznego, jest automatyczna kontrola wzbudzenia. Środowisko symulacyjne MATLAB / Simulink jest szeroko stosowane w obliczeniach i analizach normalnych stanów ustalonych i stanów nieustalonych układów elektrycznych. W artykule przedstawiono wyniki badań i porównanie parametrów eksploatacyjnych na przykładzie elektrowni wodnej Nurek. Uzyskane wyniki będą przydatne w badaniu wykorzystania nowoczesnych typów AEC w układzie wzbudzenia generatorów Nurek HPP.
EN
A model of Small Wind Turbines (SWT) based on the general functional equations under Matlab/Simulink and validate by the modeling of a real generator for residential usage is presented. The considered SWT is based on a variable rotational speed system coupled to a PMSG The method presents a huge original interest thanks to its simplicity by considering at first the response to the wind velocity in agreement to the SWT datasheet, without the necessity of a MPPT technique. Simulations are carried out with discussions showing the effectiveness of the approach.
PL
Zaprezentowano model małej turbiny wiatrowej bazujący na równaniach funkcji. Model obliczono w Matlab/Simulink i zweryfikowano w postaci wykonanej turbiny do celów domowych.. Dzięki swej prostocie model potrafi odwzorowa różne warunki pracy, przede wszystkim zmienną prędkość wiatru.
PL
W artykule przedstawiono zagadnienia techniczne związane z dostosowaniem generatora TGH-120 do pracy w charakterze kompensatora synchronicznego. Konieczność wytwarzania dodatkowej mocy biernej indukcyjnej w systemie elektroenergetycznym wynika z zastępowania starych bloków węglowych z generatorami synchronicznymi źródłami odnawialnymi. Z doświadczeń remontowych wynika, że generatory TGH-120 po przejściu na pracę ze zmiennym obciążeniem mocą czynną i bierną w szerokim zakresie oraz częstych uruchomieniach ulegają powtarzającym się uszkodzeniom, w szczególności dotyczy to uzwojenia wzbudzenia. Przedstawione nowe wdrożone do produkcji uzwojenie wzbudzenia zapewnia bezawaryjną eksploatację generatora przy dużych i częstych zmianach prądu wzbudzenia związanych z koniecznością regulacji mocy biernej.
EN
Technical issues related to adoption of TGH-120 generator for the role of reactive power compensator are presented in this paper. During the on-going transformation of Polish power system, numerous renewable energy sources are connected into the system, while old coal-fired power units are being eliminated. Most RES cannot generate inductive reactive power. Balancing reactive power in power system requires installation of devices generating reactive inductive power. After modernization, disconnected generators TGH-120 may operate as synchronous compensators. The present maintenance practice shows that when discussed generators operate in the wide range of active and reactive loads and with frequent startups, they are prone to repetitive damages. This is in particular true in case of field winding. A new design of excitation winding is presented in the paper; this has already been implemented in production. Such winding does not fail when changes of excitation current are high and frequent, such operating conditions are enforced by continuous control of reactive power. This performance has been verified by many years of failure-free operation of modernized generator and periodical overhauls of the rotor.
EN
The paper presents idea and implementation of the control of synchronous motor-synchronous generator machines set used for supplying the high-voltage test station in the electrical equipment repair and service plant. In the excitation circuits of both machines the microprocessor-controlled excitation units were used. Possibilities of generator output voltage regulation by the field current control in the synchronous state of operation were introduced. Simulation model of Matlab-Simulink and results of simulation research was shown. Exemplary realization was disclosed. Verification measurements of the real machines set in the start-up process and synchronous state of operation were presented and discussed.
PL
W artykule przedstawiono realizację sterowania zespołem napędowym silnik synchroniczny - generator synchroniczny przeznaczonym do zasilania stacji prób wysokonapięciowych. W obwodach wzbudzenia obu maszyn zastosowano mikroprocesorowo sterowane bloki zasilania wzbudzenia. Przedstawiono możliwości sterowania napięciem wyjściowym. Zamieszczono model symulacyjny oraz wyniki badań symulacyjnych. Zaprezentowano przykładowe wdrożenie. Przedstawiono wyniki pomiarów w układzie rzeczywistym.
EN
The necessity of preliminary estimation of the value of voltage dip arising at starting-up of asynchronous motor commensurate in power with operating diesel-generator sets as part of the ship electric power system is justified. The model of ship electric power system with a modified in real-time mode configuration is developed. The process of direct starting-up of asynchronous motor is simulated, and the values of voltage dips for various values of voltage and time of excitation boost of the synchronous generator are determined. It is established that there are optimum values of the magnitude and time of boosting of excitation voltage of the synchronous generator, where voltage dip in the network is minimal. The obtained results enable assessing in the process of monitoring and management of ship electric power system of the possible consequences of direct starting-up of asynchronous motor on the network voltage under current conditions, and based on them deciding on whether to connect the additional diesel generator to the network or disconnect the least essential consumers of electricity from the network to provide generated capacity reserve.
PL
Zbadano możliwości zapadu napięcia w systemie okrętowtm generatora współpracującego z silnikiem diesla. Symulowano generator asynchroniczny podłączony do sieci dla różnych warunków startu. Określono optymalna wartość napięcia wspomagającego zapewniającą minimalne zapady napięcia.
EN
In this paper a WECS (Wind Energy Conversion System) based on a PMSG (Permanent Magnet Synchronous Generator) and implementing a sensorless MPPT (Maximum Power Point Tracking ) strategy is presented using three types of generator rotor speed and angle estimators; the Angle Tracking Observer, the Extended Kalman Filter and the Synchronous Reference Frame Phase Locked Loop. The main purpose is to compare these estimators. Simulation results in Matlab-Simulink allowing this comparison can be found at the end of this work.
PL
W artykule opisano generator z magnesami stałymi PMSG wykorzystujący strategię MPPT (śledzenie maksimum mocy). Porównano trzy typy estymatorów prędkości i kąta obrotu wirnika: czujnik kąta obrotu (angle tracking observer), filtr Kalmana i synchroniczną pętlę fazową (synchronous frame phase locked loop).
PL
W artykule przedstawiono uwarunkowania prawne skłaniające do ograniczania emisji dwutlenku węgla w warunkach naszego kraju. Wykazano, że mimo niestabilnej i niesprzyjającej polityce finansowej inwestowanie w budowę lokalnych instalacji produkujących biogaz i przetwarzających go na energię elektryczną jest uzasadnione. Przedstawiono schemat technologiczny instalacji przystosowanej do przetwarzania gnojowicy, obornika bydlęcego i kukurydzy na biogaz. Wykazano, że pod względem surowcowym stado liczące ok. 1000 krów pozwala uruchomić i podtrzymać pod względem ilości niezbędnego surowca bioelektrownię o mocy 500 kW. W zestawieniach tabelarycznych przedstawiono dane dla takiej instalacji oraz dla instalacji o mocy dwukrotnie większej. Wskazano podstawowe kryteria doboru liczby zespołów prądotwórczych, typu napędu mechanicznego (silnika) dla zespołu prądotwórczego oraz samego generatora tak, aby źródła energii elektrycznej mogły pracować zarówno na sieć jak też w systemie wyspowym (wydzielonym). Wskazano na możliwość kompleksowego zagospodarowania całej wytworzonej w biogazowni energii cieplnej.
EN
The article presents the legal constraints for limiting carbon dioxide emissions in Poland. It has been shown that, despite unstable and unfavorable financial policies, investing in the construction of local biogas plants and converting them into electricity is justified. The technological processes in such installations have been described. The article presents a flowchart of the technological process of processing manure, bovine manure and maize for biogas. It has been shown that a herd of about 1000 cows provides enough waste that this enables the bio-power plant of 500 kW. Tabular data lists data for such installations and for installations with twice the power. The basic criteria for selecting the number of generating sets, the type of mechanical drive (motor) for the generating set and the generator itself, are given, so that the power sources can work both on the grid and in the island system (isolated). It was indicated the possibility of comprehensive development of all heat generated in the biogas plant.
16
Content available Nowe życie pracujących turbogeneratorów
PL
Na Wydziale Elektrycznym Politechniki Śląskiej od 25. lat prowadzone są wielokierunkowe badania naukowe mające na celu opracowanie nowych rozwiązań konstrukcyjnych turbogeneratorów wdrażanych przy rewitalizacji starych bloków energetycznych. Turbogeneratory po modernizacji mają moce zwiększone nawet o 20%, zaś resurs techniczny wzrasta od około 200 do nawet 350 tysięcy godzin. Opracowane innowacyjne rozwiązania zastosowano w turbogeneratorach pracujących w elektrowniach w Polsce oraz w wielu krajach Europy i Azji.
EN
For 25 past years, multi-directional research aimed at elaborating new constructional designs of turbogenerators which might be implemented during revitalization of old power units has been ongoing in the Faculty of Electrical Engineering of Silesian University of Technology. After modernization, turbogenerator power may be increased by even 20%, while its service life is increased from c. 200 to even 350 thousand hours. The elaborated innovative designs have been applied in turbogenerators operating in Polish power plants as well as power plants in European Union and Asian states.
PL
Niniejszy artykuł stanowi opis wykonanego stanowiska laboratoryjnego, propozycję badań stanów dynamicznych generatora synchronicznego oraz wstępną analizę wyników tych badań. Założeniem było opracowanie narzędzia pozwalającego wyznaczyć niektóre parametry modelu matematycznego generatora synchronicznego na podstawie przebiegów napięć i prądów stanów nieustalonych, występujących podczas tych procesów. Stworzony przyrząd wirtualny służy do przeprowadzenia procesów zwarcia generatora oraz synchronizacji generatora z siecią sztywną przy idealnych oraz odbiegających od nich warunkach układu oraz umożliwia rejestracje chwilowych wartości prądów i napięć niezbędnych do późniejszej analizy tych stanów. W artykule przedstawiono wyniki tych pomiarów oraz zaproponowano sposoby ich opracowania.
EN
This article is a description of laboratory stand, a testing proposal of synchronous generator in dynamic states of operation and a preliminary analysis of the results of these studies. The idea was to develop an instrument to determine some parameters of a mathematical model of synchronous generator based on the voltage and current waveforms transients occurring during those processes. Virtual measurement instrument can used to carry out the processes of generator short-circuit and the synchronization of the generator to the grid in ideal and non ideal conditions, and allows the registration of instantaneous currents and voltages needed for further analysis of these states. The article presents the results of these measurements and suggests ways of their development.
18
EN
To ensure Poland’s energy security in the coming years will require increasing the power system’s generation capacity while at the same time improving both the efficiency of electricity generation and its use [1, 2]. One way of achieving this is to revitalize the old units in power plants, thus providing a capacity increase. The most difficult technical problem is to increase the output power and overhaul life of turbogenerator sets. Research has been conducted for 25 years at the Faculty of Electrical Engineering of the Silesian University of Technology aiming at the development of new solutions of a turbogenerator set’s key major structural nodes [3]. Implemented solutions have enabled a turbogenerator set’s output power increase by as much as 20% while extending the overhaul life from 200,000 to as many as 350,000 hours. The paper presents some examples of the upgrade of the largest in the Polish power system group of 200 MW turbogenerator sets. The current status of the study is reported as well as new solutions now developed to enable further increase in turbogenerator power well above 240 MW.
PL
Zapewnienie bezpieczeństwa energetycznego Polski w najbliższych latach będzie wymagało zwiększenia mocy wytwórczych w systemie elektroenergetycznym połączonego z poprawą efektywności zarówno wytwarzania, jak i wykorzystania energii elektrycznej [1, 2]. Jednym ze sposobów realizacji tego celu jest przeprowadzenie rewitalizacji starych bloków energetycznych elektrowni zapewniającej podwyższenie mocy. Najtrudniejszym problemem technicznym jest zwiększenie mocy oraz resursu technicznego turbogeneratorów. Od 25 lat na Wydziale Elektrycznym Politechniki Śląskiej prowadzone są prace badawcze, których celem jest opracowanie nowych rozwiązań głównych węzłów konstrukcyjnych turbogeneratorów [3]. Wdrożone do produkcji rozwiązania umożliwiły podwyższenie mocy turbogeneratorów nawet o 20% przy jednoczesnym zwiększeniu resursu technicznego z 200 do nawet 350 tysięcy godzin. W artykule przedstawiono przykładowe modernizacje najliczniejszej w polskim systemie elektroenergetycznym grupy turbogeneratorów o mocy 200 MW. Zaprezentowano stan aktualny prowadzonych prac oraz opracowane nowe rozwiązania umożliwiające dalszy wzrost mocy turbogeneratorów znacznie powyżej 240 MW.
19
Content available Diagnostyka wirników generatorów synchronicznych
PL
W artykule przedstawiony został zakres badań i prób jakiemu zostaje poddany każdy wirnik na końcowym etapie remontu jakim jest wyważanie i sezonowanie. Obecnie w przemyśle energetycznym wymaga się by przestoje maszyn były jak najkrótsze, a maszyny były jak najbardziej niezawodne. Aby spełnić ten wymóg, prace wykonane podczas remontu muszą zostać zweryfikowane na kompletnie zmontowanym wirniku w stanie dynamicznym w warunkach najbardziej zbliżonych do pracy remontowanej jednostki.
PL
Niniejszy artykuł stanowi opis wykonanego stanowiska laboratoryjnego, propozycję badań stanów dynamicznych generatora synchronicznego oraz wstępną analizę wyników tych badań. Założeniem było opracowanie narzędzia pozwalającego wyznaczyć niektóre parametry modelu matematycznego generatora synchronicznego na podstawie przebiegów napięć i prądów stanów nieustalonych występujących podczas tych procesów. Stworzony przyrząd wirtualny służy do przeprowadzenia procesów zwarcia generatora oraz synchronizacji generatora z siecią sztywną przy idealnych oraz odbiegających od nich warunkach układu oraz umożliwia rejestracje chwilowych wartości prądów i napięć niezbędnych do późniejszej analizy tych stanów. W artykule przedstawiono wyniki tych pomiarów oraz zaproponowano sposoby ich opracowania.
EN
This article is a description of laboratory stand, a testing proposal of synchronous generator in dynamic states of operation and a preliminary analysis of the results of these studies. The idea was to develop an instrument to determine some parameters of a mathematical model of synchronous generator based on the voltage and current waveforms transients occurring during those processes. Virtual measurement instrument can used to carry out the processes of generator short-circuit and the synchronization of the generator to the grid in ideal and non ideal conditions, and allows the registration of instantaneous currents and voltages needed for further analysis of these states. The article presents the results of these measurements and suggests ways of their development.