1
Content available Static modelling wooden modular construction
EN
The article systematically presents the modelling of individual stages of creating wooden modular buildings with static diagrams. Descriptions of modelling the connections of the frame and sheathing boards in elements (ceiling walls) are provided. Presented models of connections using pins and connectors in the form of nails and screws. The creation of modular structures in frame and plate systems is presented. Then, the vertical and horizontal connection between the modules in the building structure was presented. Finally, the creation of a global computational model of the structure was shown, taking into account the modelling of components (walls, floors), modules and entire buildings.
PL
W artykule przedstawiono w sposób systematyczny modelowanie schematami statycznymi poszczególnych etapów tworzenia drewnianych budynków modułowych. Podano opisy modelowania połączeń szkieletu i płyt poszycia w elementach (ściany, stropy). Zaprezentowano modele połączeń na trzpienie oraz za pomocą łączników w postaci gwoździ i wkrętów, a także tworzenie struktur modułowych w układzie szkieletowym i płytowym. Następnie przedstawiono połączenie w pionie i w poziomie między modułami w konstrukcji budynków oraz pokazano tworzenie globalnego modelu obliczeniowego konstrukcji, uwzględniając modelowanie elementów składowych (ścian, podłóg), modułów i całych budynków.
PL
Stalowe konstrukcje ramowe są powszechnie stosowanym rozwiązaniem w budownictwie przemysłowym i użytkowym, gdzie kluczową rolę odgrywają odpowiednio zaprojektowane połączenia prętowe, zapewniające skuteczne przekazywanie sił oraz ciągłość pracy konstrukcji. W artykule przedstawiono klasyfikację połączeń stosowanych w konstrukcjach stalowych oraz omówiono ich wpływ na nośność, sztywność i odkształcalność całego układu nośnego zgodnie z wymaganiami normy PN-EN 1993-1-8 (EC3). Szczególną uwagę poświęcono zagadnieniu modelowania połączeń belka-słup w ramach portalowych, ze szczególnym uwzględnieniem strefy węzła okapowego, gdzie często stosuje się skosy wzdłużne rygli. Celem opracowania jest analiza wpływu różnych sposobów odwzorowania skosu na rozkład sił wewnętrznych oraz konsekwencje projektowe wynikające z tego faktu. Wskazano również na znaczenie poprawnego modelowania węzłów w kontekście analizy statycznej i projektowania, ze szczególnym uwzględnieniem aspektów bezpieczeństwa, niezawodności oraz efektywności ekonomicznej realizacji konstrukcji.
EN
Steel frame structures are a widely used solution in industrial and commercial construction, where properly designed bar connections play a key role in ensuring effective force transmission and structural continuity. This paper presents a classification of connections commonly used in steel structures and discusses their impact on the load-bearing capacity, stiffness, and deformability of the entire structural system, in accordance with the requirements of the PN-EN 1993-1-8 (EC3) standard. Special attention is given to the modelling of beam-to-column connections in portal frames, with a focus on the eaves joint area, where longitudinal haunches are frequently applied. The aim of this study is to analyse the influence of different modelling approaches for haunches on the distribution of internal forces and the resulting design implications. The importance of accurate joint modelling in the context of structural analysis and design is highlighted, with particular emphasis on safety, reliability, and economic efficiency in the execution of steel structures.
EN
The paper is devoted to numerical analysis of the roof truss subjected to upward wind loading and braced at the tensioned top chord. Linear buckling analysis was performed for the beam and shell model of the structure. As a result, the influence of rotational connection stiffness between the brace and the top chord on truss stability was noted. A bi-axial strength testing machine was used to conduct the experimental tests of the rotational connection stiffness between selected steel profiles. The results in the form of measured structural displacements and rotations were presented. The static nonlinear analysis results obtained for the shell model of the structural connection were compared to the results obtained on the experimental set-up.
PL
W pracy przeanalizowano podstawowe narzędzia projektowe w postaci norm i literatury, umożliwiające projektowanie konstrukcji drewnianych z uwzględnieniem trwałości. Na tej podstawie wskazano najważniejsze zagrożenia, a także przedstawiono zbiór podstawowych zasad projektowych. Następnie zaprezentowano identyfikację czynników ryzyka i sposoby zapobiegania im na podstawie przykładów z zaprojektowanej konstrukcji drewnianej centrum badawczo-rozwojowego.
EN
The paper presents the analysis of basic design tools in the form of standards and literature, that enable the design of timber structures taking durability into account. On this basis, the most important threats were identified and a set of basic design principles was introduced. Then, the identification of risk factors and methods of preventing them were presented, that was based on examples from the designed timber structure of the research and development center.
5
Content available remote Połączenia na wkręty elementów z blach cienkich
PL
Cable-pooling to współdzielenie przyłącza, czyli tak właściwie infrastruktury przyłączeniowej oraz mocy przyłączeniowej w przyłączu. Do polskiego systemu prawnego takie rozwiązanie wprowadzono 1 października 2023 r. celem optymalizacji wykorzystywanych mocy przyłączeniowych. Pozwala na przyłączanie więcej niż jednej instalacji OZE do jednego miejsca przyłączenia.
EN
In Poland, until 2010, a number of buildings were built with the support structure of roofs in the form of timber trusses connections with punched metal plate fasteners. Standardisation changes, i.e. the introduction of Eurocodes in 2010, resulted in, among other things, increasing the values of recommended climatic loads. Due to the above, in structures built several years ago, the load capacity limit for both timber and fasteners is exceeded. Modernisation of structures with these trusses usually leads to the need to strengthen existing nodes. The issue of strengthening connections with punched metal plate fasteners is poorly recognised in experimental (failure) tests, and thus there are no detailed standard guidelines. The purpose of the experimental tests was to identify the behaviour of tension connections on metal plate fasteners and to evaluate the impact of the additional reinforcement in the form of perforated plates and screws. The analysis of the results obtained from the experimental tests allows us to conclude that the reinforced nodes achieved a much higher ultimate load than the one resulting from the design calculations.
PL
W Polsce do 2010 roku wybudowano szereg obiektów z konstrukcją nośną dachów w postaci drewnianych wiązarów z węzłami na płytki kolczaste. Zmiany normalizacyjne, tj. wprowadzenie w 2010 r. eurokodów dotyczących obciążeń, spowodowało między innymi zwiększenie wartości zalecanych obciążeń klimatycznych. W związku z powyższym w konstrukcjach wybudowanych kilka lat temu dochodzi do przekroczenia limitu nośności zarówno dla drewna, jak i łączników. Modernizacja obiektów z wiązarami drewnianymi, z reguły prowadzi do konieczności wzmacniania istniejących węzłów. Zagadnienie wzmacniania złączy na płytki kolczaste jest słabo rozpoznane w badaniach doświadczalnych (niszczących), a tym samym brak jest szczegółowych wytycznych normowych. Celem przeprowadzonych badań doświadczalnych było rozpoznanie zachowania się rozciąganych złączy na płytki kolczaste oraz oceny wpływu zastosowanego dodatkowego wzmocnienia w postaci płytek perforowanych i wkrętów. Analiza otrzymanych wyników badań doświadczalnych upoważnia do stwierdzenia, że wzmocnione węzły osiągnęły znacznie większe obciążenie granicznie niż to, które wynikało z obliczeń projektowych.
EN
This study evaluates the cyclic response of the Precast Hollow Core Slab (PHCS) to the beam connection by proposing a novel connection detail. The evaluation involved, three different connection details, namely, (1) Continuity rebar and U-type Core Rebar Discrete with 100 mm ledge width (CUCRD_100); (2) continuity rebar and Core Rebar Combined with 100 mm ledge width (CCRC_100); and (3) continuity rebar and Core Rebar Combined with Ties along with 100 mm ledge width (CCRCT_100) were experimentally validated. These were validated through experimental testing, comparing their performance with a reference specimen that adhered to New Zealand guidelines using Continuity rebar and Core Rebar Discrete with 100 mm ledge width (CCRD_100). Displacement controlled reverse cyclic loading, following the ACI T1.1–0.1 protocol, was applied to the end of a hollow core slab for the experimental testing. The structural performance of all four connections considered failure pattern, strength, hysteretic behaviour, energy dissipation, displacement ductility, stiffness degradation, and equivalent viscous damping. The overall seismic efficiency of the connections was assessed using ACI 374.1–05 approval criteria. The experimental results proved that the peak load-carrying capacity for CCRCT_100 specimen was observed to be greater in both directions of loading (positive and negative) when compared with the other connection detailing. The presence of transverse reinforcement enhanced the confining capacity of the concrete in the joint region which substantially increased the ductility and dissipation of energy in CCRCT_100 specimen. The seismic performance of every connection specimen was favourable, and they all met the ACI 374.1–05 approval standards.
PL
Kształtowanie układów warstw materiałowych przegród zewnętrznych i złączy budynku o niskim zużyciu energii nie powinno być przypadkowe, lecz opracowane na podstawie szczegółowych obliczeń i analiz parametrów fizycznych z uwzględnieniem przepływu ciepła w polu dwuwymiarowym (2D). W artykule przedstawiono autorski algorytm kształtowania układu materiałowego przegród zewnętrznych i ich złączy w aspekcie cieplno-wilgotnościowym oraz analizę parametrów fizycznych połączenia ściany zewnętrznej ze stropem w przypadku rożnych układów materiałowych.
EN
Shaping the material layers of the building envelope and joints with low energy consumption should not be accidental, but based on detailed calculations and analyzes of physical parameters, taking into account heat flow in a two-dimensional (2D) field. The article presents an original algorithm for shaping the material arrangement of external partitions and their joints in terms of heat and humidity, as well as an analysis of the physical parameters of the connection of the external wall with the ceiling with different material arrangements.
EN
Purpose To evaluate the effectiveness of determining the strength of loose rings made, polymer laminate, using a 3-point bending test of rectangular material specimens differing in form and dimensions from actual structural components. Design/methodology/approach The analysis carried out indicated a method of quantitative evaluation that could be directly related to the operating conditions of the rings. A similarity relation between the critical states of the ring and the specimens subjected to bending tests was presented. The assumed hypothesis of maximum tensile stresses of the rigid outer laminate layers provided the basis for formulating a criterion for the allowable loads on the rings, depending on the assembly tension of the bolts and the operating pressure in the installation. Findings The results of the bending tests, both in the elastic and failure range of the samples, confirmed the validity of the hypothesis about the proportionality of the breaking stresses in the ring and the bending, cuboid sample, made of a similar laminate. Practical implications The area of dimensional optimisation of the joint with regard to its strength and stiffness criterion is indicated. Originality/value The method provides a basis for evaluating the strength and tightness of a flange connection by means of experimental testing of specimens made of a laminate similar to the material of the rings. The results of the 3-point bend tests allow for the substitution of difficult tests of complex assembly components such as rings in a flanged connection, including the operating conditions of the connection in a pressure piping system.
PL
Artykuł przedstawia koncepcję oraz badania doświadczalne prototypowego połączenia poziomego prefabrykowanego zbiornika cylindrycznego. Połączenie zostało zaprojektowane na potrzeby przedsiębiorstwa Sienkiewicz MAT-BUD Sp. z o.o. Zaproponowane rozwiązanie łączenia elementów prefabrykowanych zbiornika nie wymaga wykonywania prac mokrych na miejscu budowy. Wykorzystuje ono krzywiznę płaszcza zbiornika cylindrycznego, umożliwiającą wprowadzenie śruby łączącej. Będący przedmiotem badań doświadczalnych łącznik zaprojektowano na siłę rozciągającą do 200 kN.
EN
The article presents the concept and experimental testing of a prototype connection of a horizontal, prefabricated cylindrical tank. The connection was designed for the Sienkiewicz MAT-BUD Sp. z o.o. company. The proposed solution for connecting prefabricated elements of the tank, does not require wet work on site. The proposed solution takes advantage of the curvature of the cylindrical tank shell, allowing the introduction of a connecting bolt. The connector, which is the subject of the experimental study, was designed for a tensile force of up to 200 kN.
PL
Regardless of the operating conditions, a load acts on the parts of a machine in different directions. These loads in particular determine the required strength and resistance of parts and determine the study and selection of appropriate strength, resistance parameters for the parts. This can be determined by their impact on oilfield equipment and machine parts. Testing is done to determine the static flexibility, flow limit, tensile strength relative to flexibility, strength period limit, and plastic deformation coefficient. In some cases, when the limits of wear of machine parts are equal, elements with a larger coefficient of deformation are more convenient. These regularities should be used in those cases when it is possible to apply the methods of fracture mechanics or when there are direct experimental data on the development of fatigue cracks, which make it possible to carry out a probabilistic assessment of the durability of structural elements at the stage of crack growth and to substantiate the corresponding limitations on the service life of products. For the safety margins of machine parts, the starting points are as follows: longitudinal bending stress in the sleeve of a solid machine part made of a plastic material cannot damage the part. The length of the first crack can be taken to be equal to several millimetres, which is determined by the capabilities of the simplest means of observation, and by the fact that in some cases even a crack of such length can be critical from the point of view of a potential brittle fracture. In this regard, the fatigue resistance characteristics used in such a calculation should correspond to the point at which the first macroscopic crack appears.
EN
Niezależnie od warunków pracy na części maszyn działają obciążenia w różnych kierunkach. Obciążenia te w szczególności określają wymaganą wytrzymałość i odporność zmęczeniową części maszyn oraz determinują dobór metod badawczych oraz dobór odpowiednich parametrów wytrzymałościowych i odpornościowych tych części. Parametry te można określić poprzez ich oddziaływanie na urządzenia i części maszyn na złożach ropy naftowej, które są poddawane wyższym obciążeniom i odznaczają się wyższymi wartościami granicznymi zużycia. Badania wykonuje się w celu określenia elastyczności statycznej, granicy płynięcia, wytrzymałości na rozciąganie w stosunku do elastyczności, granicy okresu wytrzymałości oraz współczynnika odkształcenia plastycznego. W niektórych przypadkach, gdy wartości graniczne zużycia części maszyn są sobie równe, bardziej praktyczne w użytkowaniu są elementy o większym współczynniku odkształcenia. Prawidłowości te powinny być wykorzystywane w tych przypadkach, gdy możliwe jest zastosowanie metod mechaniki powstawania pęknięć lub gdy istnieją bezpośrednie dane doświadczalne dotyczące rozwoju pęknięć zmęczeniowych, które umożliwiają przeprowadzenie probabilistycznej oceny trwałości elementów konstrukcyjnych na etapie wzrostu pęknięć i uzasadnienie odpowiednich ograniczeń trwałości użytkowej wyrobów. W przypadku ustalania marginesów bezpieczeństwa dla części maszyny przyjmuje się następujące założenie wyjściowe: wzdłużne naprężenia zginające w wykonanej z tworzywa sztucznego tulei stałej części maszyny nie mogą spowodować jej uszkodzenia. Długość pierwszej rysy można przyjąć jako równą kilku milimetrom, co jest uzależnione od stosowanych metod obserwacji oraz faktu, że w niektórych przypadkach nawet rysa o takiej długości może być krytyczna z punktu widzenia potencjalnego wystąpienia pęknięcia kruchego. W związku z tym charakterystyka wytrzymałości zmęczeniowej, stosowana w takich obliczeniach, powinna odpowiadać punktowi, w którym pojawia się pierwsze makroskopowe pęknięcie.
PL
W artykule przedstawiono wyniki badań zespolonych elementów belkowych. Głównym celem analiz było określenie wpływu kształtu przekroju poprzecznego styku na pracę statyczną układu zespolonego. Rozważano pełne zespolenie styku beton-beton oraz styku, w którym zastosowano środek antyadhezyjny. Badania zasadnicze, które dotyczyły belek o złożonym przekroju styku, poprzedzono testami na elementach o przekroju prostokątnym i o płaskiej powierzchni zespolenia. Udowodniono eksperymentalnie, że belka składająca się z prefabrykatu w kształcie żebra z powierzchnią zespolenia pozbawioną adhezji pracowała od początku badania jako częściowo zespolona. Sztywność na zginanie elementu bez pełnego zespolenia była przed wystąpieniem pierwszej rysy pionowej o 14,9% mniejsza niż belki w pełni zespolonej. W obu belkach doszło do połączenia zarysowań pionowych z rysami w styku. Belki utraciły nośność ze względu na zmiażdżenie strefy ściskanej nadbetonu.
EN
The article presents a study of composite prestressed beams. The scope of the research is to determine the influence of the shape of the interface cross-section joint on the static work of the beams. The elements were divided into beams with a natural joint surface and broken adhesion in contact. Preliminary tests were done on the beams with a rectangular cross-section and a flat interface surface. The leading research focused on beams with complex cross-sections. It has been proven experimentaly the beam, made of a rib-shaped precast element with broken adhesion, worked as partially composite from the beginning of the test. Before the first vertical crack occurred, the bending stiffness of the element with a broke adhesion interface was 14.9% lower than that of a fully bonded beam. In both beams, vertical cracks connect with cracks in the interface. Beams load capacity were achieved due to the crushing of the compression zone of the concrete overlay.
EN
Purpose: This paper describes the study of the connection with loose fixing composite rings of pipe flanges. The elastic properties of the joint components - gasket, pressure flanges, rings and fixing bolts were determined experimentally. Design/methodology/approach: The criterion of joint tightness was formulated. The constructed model was used to determine the analytical dependence of the joint leakage pressure on the assembly torque of bolts tightening. The correctness of the model was confirmed by the agreement of the analytical results with the experimental results. Findings: Quantitative characteristics were determined for the selected type of joint. Practical implications: The formulated conclusions indicate the possibility of using the model to support the design process and to select the structural parameters of the joint meeting the operational requirements and safety criteria. Originality/value: Produced with recycled materials using.
PL
W artykule zamieszczono prezentację instalacji elektrycznych w części wspólnej wielorodzinnych budynków mieszkalnych. Obejmują one zasilanie i rozdział energii elektrycznej oraz pomiar odrębny dla instalacji w części wspólnej, jak i liczniki dla lokali mieszkalnych, a także opcjonalnie dla lokali usługowych. Ponadto w tej części budynku występują instalacje odbiorcze w pomieszczeniach technicznych i w przestrzeniach takich jak garaże, piwnice, strychy, klatki schodowe itp., przeznaczonych dla wszystkich mieszkańców.
EN
The article presents electrical installations in the common part of multi-family residential buildings. They include power supply and distribution of electricity and separate metering for the installation in the common area, as well as meters for residential premises, and optionally for service premises. In addition, in this part of the building there are receiving installations in technical rooms and spaces such as garages, basements, attics, staircases, etc., intended for all residents.
EN
The work concerns the influence of the method of numerical modelling of the connections of the roof truss and vaults with the walls of historic masonry objects structures on the local stress distribution in the walls. At the outset, the need to search for rational modelling was justified due to the large size of the calculation models and the erroneous results obtained with oversimplification of the model. Four methods of modelling the connections between the walls and roof truss and vaults were analysed. The first method was to describe the elements of walls and foundations as solid elements, the ribs of the vaults and the roof truss as beam elements, and the vaulting webs as shell elements. The remaining methods 2-4 describe the walls as shell elements. In places where the walls join with the roof truss and vaults, fictitious/fictional elements in the form of rigid horizontally-oriented shells were used in model No. 2. In model No. 3, fictitious rigid horizontally-oriented shell elements in addition to local rigid vertically-oriented shells were used, while in model No. 4, only fictitious rigid vertically-oriented shell elements with stepwise decreasing protrusions were introduced. The best solution in terms of local stress distribution turned out to be the description of connections with fictitious shell elements in the case of model No. 4. This approach slightly increases the number of unknowns, and makes the results of stresses in the connection areas realistic in relation to full modelling with solid finite elements.
PL
Praca dotyczy wpływu sposobu numerycznego modelowania połączeń więźby dachowej i sklepień ze ścianami zabytkowych obiektów murowych na lokalny rozkład naprężeń w ścianach. Na wstępie uzasadniono potrzebę poszukiwań racjonalnego modelowania z uwagi na duże rozmiary modeli obliczeniowych lub błędnych wyników przy zbytnich uproszczeniach modelu. Przedstawiono aktualnie stosowane sposoby modelowania, w tym stosowanie sztywnych elementów skończonych między nieprzecinającymi się osiami konstrukcyjnymi elementów. Przeanalizowano cztery sposoby modelowania połączeń więźby dachowej i sklepień ze ścianami. Pierwszy sposób to opisanie elementów ścian i fundamentów elementami bryłowymi, żeber sklepień i więźby dachowej elementami belkowymi, a wysklepek sklepień elementami powłokowymi. Pozostałe sposoby 2-4 to opisanie ścian elementami powłokowymi. W miejscach połącznia ścian z więźbą dachową i ze sklepieniami w modelu No. 2 zastosowano fikcyjne elementy w postaci sztywnych powłok zorientowanych poziomo. W modelu No. 3 również wprowadzono fikcyjne sztywne powłoki poziome oraz lokalnie dodatkowo sztywne powłoki zorientowane pionowo, natomiast w modelu No. 4 wprowadzono tylko fikcyjne sztywne pionowe elementy powłokowe o skokowo zmiennym wysięgu. Najlepszym rozwiązaniem w zakresie rozkładu lokalnych naprężeń okazał się opis połączeń fikcyjnymi elementami powłokowymi w przypadku modelu No. 4. Takie podejście niewiele zwiększa liczbę niewiadomych, a urealnia wyniki naprężeń w rejonach połączeń w stosunku do pełnego modelowania bryłowymi elementami skończonymi.
EN
Three equivalent exterior precast concrete beam-column (PCBC) connections have been investigated in this study in orderto analyze the effect of steel fiber reinforced concrete (SFRC) as cast-in-place (CIP) on the seismic performance of the PCBC connection. The connection was designed as a ductile connection for a moment-resisting frame and consists of a precast U-beam, precast column with corbel, interlocking bars, and CIP-concrete to connect the precast beam to precast column. The volume fractions of steel fiber incorporated within the CIP-concrete were 0%, 0.5% and 1%. A quasi-static load was applied vertically to the beam tip of the PCBC specimen. The results showed that the steel fibers contained within the CIP-concrete provided 2% increase of the maximum load, 17.7% increase of the energy dissipation, and increase in the joint stiffness of the PCBC connection. The steel fibers delayed the onset of cracking and slowed down the crack propagation, resulting in shorter cracks in the joint core of PCBC specimen, which correlates well with the deflection-hardening characteristic found from the modulus of rupture test.
PL
W artykule wyjaśniono pojęcie stropu i wymieniono różne jego rodzaje. Autor omówił konstrukcję stropu i zwrócił uwagę na jego połączenie z płytą balkonową.
EN
The article explains the concept of a ceiling and lists its different types. The author discussed the structure of the ceiling and drew attention to its connection with the balcony slab.
first rewind previous Strona / 5 next fast forward last