Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 17

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  current distribution
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Modeling of a wire antenna electromagnetic field
EN
A mathematical model of the electromagnetic field of a wire antenna in a steady (stationary) mode of radiation is built, which is presented in the form of a system of Maxwell's equations. Analytical representations are found for the components of the electric field strength of the wire antenna, which allowed calculating the value of the current along the antenna. The method used to calculate the electromagnetic field strength of a wire antenna can also be used when calculating the electromagnetic field with more complex boundary conditions. Numerical calculations of the current distribution along the antenna given in the paper are close to the experimental values.
PL
Zbudowano matematyczny model pola elektromagnetycznego anteny drutowej, który przedstawiono w postaci układu równań Maxwella. Dla składowych natężenia pola elektrycznego anteny drutowej znaleziono analityczne odwzorowania, co pozwoliło na obliczenie wartości prądu wzdłuż anteny. Metoda wykorzystywana do obliczania natężenia pola elektromagnetycznego może być również wykorzystywana do rozwiązywania problemów o bardziej złożonych warunkach brzegowych. Podane w pracy obliczenia numeryczne rozkładu prądu wzdłuż anteny są zgodne z danymi eksperymentalnymi.
EN
The compilation of unfavourable weather conditions, such as negative temperature and high humidity, leads to the formation of an ice layer and deposits on the elements of the overhead contact line, which leads to its degradation and prevents the supply of electricity to the traction vehicle. The traction line is located on a very large area and it is extremely difficult to effectively remove the remaining layers of ice. During planning the anti-icing measures it’s very important to know the current distribution in wires. The authors of the article analysed the catenaries operated in Poland and in EU in terms of the current distributions in contact and catenary wires in through spans. The approach presented in this paper allows to take into account the wear of the contact wires during calculations of the current distributions.
PL
Szereg niekorzystnych warunków atmosferycznych, takich jak ujemna temperatura i wysoka wilgotność, powoduje powstanie warstwy lodu i osadów na elementach sieci trakcyjnej, co prowadzi do jej degradacji i uniemożliwia dostarczanie energii elektrycznej do pojazdu trakcyjnego. Sieci trakcyjne znajdują się na rozległych obszarach i niezwykle trudno jest skutecznie usunąć warstwę lodu. Podczas planowania czynności mających na celu odlodzenie sieci jezdnych bardzo ważna jest znajomość rozpływu prądu w przewodach. Autorzy artykułu przeanalizowali sieci trakcyjne eksploatowane w Polsce i w UE pod kątem rozpływu prądów w przewodach jezdnych i linach nośnych w całym przęśle naprężenia. Przedstawione w niniejszej pracy podejście pozwala na uwzględnienie zużycia przewodów jezdnych podczas obliczeń rozpływu prądów.
EN
A compact Sierpinski Carpet square fractal multiband antenna operating at 3.9 (WiMAX) /6.6 (Satellite TV) /8.1/10.7/11.8 GHz (X-band) is presented. The proposed Microstrip Patch Antenna (MSPA) consists of a Sierpinski Carpet square fractal radiator in which square slots are etched out and a tapered microstrip feed line. The Sierpinski Carpet square fractal patch modifies the current resonant path thereby making the antenna to operate at five useful bands. Impedance matching at these bands are solely achieved by using Sierpinski square slot and tapered feedline, thus eliminating the need of any external matching circuit. The dimensions of the compact antenna is and exhibits S11<-10dB bandwidth of about 4.8% (4.01-3.82 GHz), 2.1% (6.62-6.48 GHz), 2.7% (8.24-8.02 GHz), 2.1% (10.77-10.54 GHz) and 21% (12.1-11.60 GHz) with the gain of 7.57/3.91/3.77/6.74/1.33 dB at the operating frequencies 3.9/6.6/8.1/10.7 and 11.8 GHz, respectively under simulation analysis carried out by using HFSS v.13.0.
EN
A compact planar multiband antenna operating at 3.1 (S-band) /4.7/6.4/7.6 (C-band) /8.9/10.4/11.8 GHz (X-band) is presented. The proposed Microstrip Patch Antenna (MSPA) consists of a rectangular radiator in which an E-shaped slot is etched out and a microstrip feed line. The E-shaped slot modifies the total current path thereby making the antenna to operate at seven useful bands. No external impedance matching circuit is used and the impedance matching at these bands are solely achieved by using a rectangular microstrip feed line of length 10mm (L6) and width 2mm (W10). The antenna has a compact dimension of and exhibits S11<-10dB bandwidth of about 6.45% (3.2-3.0GHz), 8.5% (4.9-4.5GHz), 7.6% (6.7-6.2GHz), 3.9% (7.8-7.5GHz), 5.7% (9.1-8.6GHz), 1.2% (10.44-10.35GHz) and 2.2% (11.87-11.62GHz). The simulation analysis of the antenna is carried out by using HFSS v.13.0.
EN
In this article, the current distribution of an antenna array in the presence of mutual coupling is calculated analytically by solving Pocklington’s integral equation. Blockpulse and Galerkin’s functions are used for numerical solving of Pocklington’s integral equation. In this work, the surface current distribution can be achieved for an antenna array in receiving mode, with any arbitrary structure and various numbers of elements. In all previous works, the authors have been tried to solve Pocklington’s integral equation for a single half dipole antenna in transmitting mode. Pocklington’s equation is somehow difficult to work with because of the singularity and existence of a sharp peak for a small value of wire’s radius. In order to calculate surface current distribution, for thin wires, singularity part is extracted from the kernel in aforementioned integral. Hence, the kernel is decomposed into singular and nonsingular parts. An inter-element mutual coupling effect between array elements and self-coupling for each element are assumed in this case. The validity of the proposed methodology is tested by numerical simulation results. The accuracy of the proposed method is evaluated by the multiple signal classification (MUSIC) algorithm for different scenarios to direction of arrival (DOA) estimation.
EN
The new 2G HTS tapes with high critical current and high resistivity in the normal state allow to build low-cost transformers with high short-circuit strength for the low and medium power distribution substations. The authors consider that currently the best chance of building have transformers, which rated currents of their windings do not exceed or slightly exceed the critical current of used superconducting tapes. Such units could be the low or medium voltage transformers with power less than 10 MVA, where the high voltage winding can be made with single HTS tape while the low voltage winding can also be made of single HTS tape or two – three tapes connected in parallel. This eliminates the need of tape transposition or application of the Roebel’s cable. Superconducting transformers could stabilize the low or medium power network and increase the connectivity of renewable and dispersed energy sources. The article presents an analysis of the possibility of using the low and medium voltage superconducting transformers. Such units could be e.g transformers working with renewable energy sources.
PL
Nowe taśmy nadprzewodnikowe 2G HTS o wysokim prądzie krytycznym i wysokiej rezystywności w stanie rezystywnym pozwalają na budowę transformatorów o wysokiej odporności na zwarcia dla sieci dystrybucyjnych niskich i średnich energii. Obecnie największe szanse na budowę mają transformatory, których znamionowe prądy uzwojeń nie przekraczają lub nieco przekraczają wartości prądu krytycznego zastosowanych taśm nadprzewodnikowych. Takimi jednostkami mogą być transformatory niskiego lub średniego napięcia o mocy poniżej 10 MVA, gdzie uzwojenie wysokonapięciowe może być wykonane pojedynczą taśmą HTS, a uzwojenie niskonapięciowe może być również wykonane z pojedynczej taśmy HTS lub dwóch - trzech taśm połączonych równolegle. Eliminuje to konieczność transpozycji taśm a tym samym zastosowania kabla Roebel. Zastosowanie transformatorów nadprzewodnikowych mogłoby ustabilizować sieć energetyczną niskiego i średniego napięcia i zwiększyć zdolność łączeniową odnawialnych i rozproszonych źródeł energii.
EN
The parallelism is a well known technique for increasing the power capacity of converters because it helps to overcome the current limitations of semiconductor devices. Multi-channel (interleaved) converters use a kind of parallelism that, thanks to their own particular features, makes it possible to map more accurately the converter output signal in a reference one. However, multi-channel converters present several disadvantageous. The most important problem consists in the fact that the output current may not be distributed equally in converter channels what requires additional components supporting this mechanism. In contrast to the generally used methods software only solution of the controller for balancing of current distribution is proposed in this paper. The controller constitutes part of a control system of wide-band power electronics current and voltage source. The paper presents an idea and principles of work of such controller. Also, results of converter simulation model experiments are presented.
PL
Łączenie równoległe przekształtników jest przyjętym sposobem zwiększenia mocy dysponowanej dla zasilania odbiorników energii elektrycznej. W przypadku przekształtników wielokanałowych (ang. „intereleaved”) możliwe jest również uzyskanie lepszej wierności odwzorowania energetycznego sygnału wyjściowego w sygnale referencyjnym (odniesienia). Przekształtniki te mają jednak, co najmniej jedną niekorzystną cechę związaną z tym, że prąd wyjściowy może nie rozpływać się równomiernie w poszczególnych kanałach. Wymaga ona stosowania dodatkowych rozwiązań sprzętowych, wspomagających mechanizm równoważenia rozpływu prądów. W przeciwieństwie do powszechnie używanych metod, w pracy przedstawiono propozycję kontrolera rozpływu prądów rozwiązanego wyłącznie programowo. Możliwe jest przez to ograniczenie kosztów, stopnia złożoności oraz gabarytów przekształtnika. W pracy przedstawiono zasadę pracy takiego kontrolera w sterowanym energoelektronicznym źródle napięcia i prądu. Zamieszczono w niej również wybrane wyniki badań modelu symulacyjnego układu.
EN
In this paper the time shape of a current pulse along a conductor is investigated by applying the Partial Element Equivalent Circuit (PEEC) method. The pulse is injected by a current source at one end of a perfect conductor placed in a conductive medium. Implementing the thin wire approximation, the current distribution is calculated in the frequency domain, while the time shape of the pulse is reconstructed using Inverse (Fast) Fourier Transform (IFFT). The developed model is verified by comparison with results found in other literature and shows satisfactory agreement.
PL
W artykule przebadano przebieg czasowy impulsów prądowych wzdłuż przewodu przy zastosowaniu metody obwodu zastępczego z elementami cząstkowymi. Impulsy są aplikowane ze źródła prądowego na końcu idealnego przewodu umieszczonego w przewodzącym środowisku. Implementując aproksymację cienkim przewodem, rozkład prądu obliczany jest w obszarze częstotliwościowym, podczas gdy przebieg czasowy impulsu został zrekonstruowany przy użyciu odwrotnej szybkiej transformaty Fouriera. Opracowany model został zweryfikowany przez porównanie z wynikami znalezionymi w literaturze i wskazano na zadowalającą zgodność.
PL
W artykule przedstawiono wyniki analizy rozkładu pola przepływowego prądu w wirniku tarczowym maszyny homopolarnej. Zaprezentowano dwuwymiarowy model oparty na metodzie elementów skończonych. Ograniczono się do zbadania rozkładu pola przepływowego bez uwzględniania zewnętrznego pola magnetycznego i ruchu wirnika. Opracowanie modelu uwzględniającego pozostałe zjawiska jest przedmiotem dalszych prac. Analizowano rozkład pola w tarczy zasilanej różną liczbą szczotek rozmieszczonych na obwodzie wirnika tarczowego i pierścienia wewnętrznego. Rozkład pola wyznaczony został za pomocą stworzonego w języku C programu. W algorytmie wykorzystano opracowany model.
EN
The article presents results of current distribution analysis in a disc rotor of a homopolar machine. The two-dimensional model based on the finite element method without taking into account external magnetic field and movement of a rotor has been proposed. Current distribution in a rotor with different number of supplying brushes has been analyzed. Field distribution has been determined using the computer program written in C language. The algorithm of the program uses the presented model.
EN
This paper presents transient analysis of a horizontal buried conductor performed by applying the Partial Element Equivalent Circuit (PEEC) method. A fast rising pulse is injected by a current source at one end of a perfect conductor placed in a finitely conductive ground. The presence of ground/air boundary surface is taken into account by implementing the image theory. The current distribution along the conductor is calculated in the frequency domain, while the time shape of the pulse is reconstructed using Inverse (Fast) Fourier Transform (IFFT). The developed technique is verified by comparison with results calculated with the Numerical Electromagnetic Code 4 (NEC4) solver and shows satisfactory agreement.
PL
W artykule zaprezentowano analizę stanu przejściowego w poziomo zakopanym przewodzie przez zastosownie metody obwodu zastępczego. Szybko narastający impuls aplikowany jest poprzez źródło prądowe na końcu przewodnika umieszczonego w gruncie o skończonej przewodności. Obecność granicy zienia/powietrze uwzględnina została poprzez wykorzstanie metody odbić. Rozkład prądu w przewodnikuobliczany jest w obszarze częstotliwościowym, podczas gdy czasowy kształt impulsu jest rekonstruowany poprzez metodę odwrotnel szybkiej transformaty Fouriera (IFFT) Rozwijana technika została zweryfikowana przez porównanie wyników obliczeń uzyskanych przez oprogramowanie CODE4 Zgodność została osiągnięta w stopniu zadowalającym.
EN
This paper presents a methodological analysis of differences between the classical method of moments (MoM) approach and the partial element equivalent circuit (PEEC) approach to determination of current along a conductor. A step by step investigation is performed of the two approaches while they are applied on a perfect conductor placed in a conductive environment, excited by a current source at one end. The fundamental discrepancy points of the two methods are marked and theoretical explanations of those discrepancies are offered during the analysis. Finally, the numerical results for the current along the conductor obtained by the two methods are compared.
PL
W artykule zaprezentowano analizę metodologiczną różnicy między klasyczną metodą momentów MoM a metodą elementu zastępczego PEEC przy wyznaczaniu prądu w przewodniku. Analizowano dobrze przewodzący przewodnik umieszczony w przewodzącym środowisku i zasilany na jednym końcu.
12
PL
Przeprowadzono badania eksperymentalne i symulacje komputerowe rozpływu prądu udarowego w urządzeniu piorunochronnym niewielkiego obiektu budowlanego. Stwierdzono, że kształty przebiegów prądu wprowadzonego do urządzenia piorunochronnego oraz wpływającego do systemu jego uziemienia i do instalacji elektrycznej chronionego obiektu różniły się znacznie między sobą. Relacje wartości prądu wpływającego do instalacji elektrycznej do prądu wprowadzonego do urządzenia piorunochronnego, zależały od konfiguracji tego urządzenia.
EN
Experiments and computer simulations were conducted of surge current distribution in a lightning protective system (LPS) of a residential structure. It was found that waveshapes of currents: injected into the LPS, flowing into the grounding system and flowing into wiring system of the object, differed considerably from each other. Value relations of the current flowing into wiring system to the current injected into the lightning protective system depended on configuration of the LPS.
13
Content available remote Current Distribution Modelling in Electroconductive Fabrics
EN
In this paper the current distribution within woven electroconductive textile sheets is investigated. The iterative method of solving very large resistor networks, which is used to model current density in textile sheets, is discussed. Factors taken into account are the conductivity of the fibres, the contact resistance between the fibres, the contact angle between the fibres and supply electrodes, as well as the size and aspect ratio of textile sheets. The influence of these factors on sheet resistivity is discussed. Maps of the current distribution generated with a computer program are included.
PL
W pracy badano rozkład prądu w elektroprzewodzących warstwach tkanin. Przedyskutowano stosowanie iteratywnej metody rozwiązywania bardzo dużych sieci oporów stosowanych dla modelowania gęstości prądów płynących w warstwach tekstylnych. czynnikami, które brano pod uwagę były przewodność elektryczna włókien, oporność przejścia pomiędzy włóknami, kąt kontaktu pomiędzy włóknami i doprowadzeniami prądu, jak również rozmiar badanych próbek. Przedyskutowano wpływ tych parametrów na oporność próbki. Mapy rozpływu prądu wygenerowanych specjalnym programem komputerowym przedstawiono również w artykule.
14
Content available remote Model analityczny elektryzacji strumieniowej w warunkach przepływu turbulentnego
PL
W artykule zaproponowano model rozkładu gęstości prądu elektryzacji w rurce. Model uwzględnia dyfuzję, konwekcję oraz przewodnictwo jako mechanizmy transportu nośników ładunku. Jako parametr wiążący równania przepływu oraz równania pola elektrycznego wykorzystano kombinację współczynnika dyfuzji molekularnej oraz współczynnika dyfuzji turbulentnej. Model zakłada podział obszaru przyściennego rurki na trzy warstwy: turbulentną, lepką oraz przejściową, w której w różny sposób uwzględniano dynamikę przepływu cieczy.
EN
In paper a model of streaming electrification current distribution in pipe was proposed. The model takes into account diffusion, convection and conduction phenomena as an ionic transport mechanism. A combination of both, molecular and turbulent diffusivity was used for linking a flow and electric field equations. The model assumes division of a boundary region into three layers. The viscous, buffer and turbulent layer were differently treated with regard to application of diffusion coefficient in EHD equations.
EN
A new approach to the theory of excess current carrier distribution in the homogeneous base region of the semiconductor multi-junction structure is proposed. Numerical analysis of this structure is performed taking into consideration an assumption that concentrations of excess electrons and holes in the semiconductor are equal (the neutrality principle). To obtain excess carrier distributions in this structure it is necessary to solve continuity equations of electron J n and hole J p current densities. A general solution is obtained and numerically calculated distributions of excess carriers and electrical potential for cases interesting from the point of view of their application in injection modulated thermal radiation structures destined for dynamic scene projectors are presented.
PL
W artykule dokonano analizy przyczyn zmiany rozpływu prądów w elektrycznej kopalnianej sieci trakcyjnej po zmianie konfiguracji sieci, polegającej na skróceniu torów i zastąpieniu ich przewodem podwieszonym na słupach trakcyjnych. Przeprowadzono badania w warunkach rzeczywistych pozwalających na ocenę zjawisk powodowanych przez prądy powrotne płynące w ziemi, przede wszystkim na procesy nagrzewania się uziomów stacji zasilających oraz wzrostu napięć dotykowych.
EN
The reasons of the changes of current distribution within the mine traction after change of the network configuration consisting in shortening of the tracks and their replacement with an overhead wire mounted at traction posts have been analysed in the paper. The tests have been made under real conditions, allowing the phenomena caused by return current flowing in the earth (heating processes of earth electrodes of the supply stations and increase of touch voltage), to be evaluated.
EN
The novel construction of the modular concentric transformer for power electronics is described and analyzed in the paper. Proposed design of the transformer is dedicated for high frequency (the best results are in the range of 500 kHz to 3 MHz). The transformer has two windings made of concentrically arranged, thin-walled pipes, formed as a multi-turn spiral and put into magnetic core. The primary (inner) turns are connected in series and secondary (outer) ones are connected in parallel. The transformer described in the paper has turn-to-turn ratio 2:1, but in general the turn ratio can be different. The transformer is of high efficiency (above 98%) and very high ratio of windings coupling (about 0,998). High power density (above 100 kW/kg) for output power about 5 kW is its additional advantage. The paper is focused on influence of the shape and arrangement of the windings and magnetic core on the transformer properties. The results of analysis (efficiency, output power and power density) determine optimal design of transformer with respect of relevant transformer parameters. The analysis is based on FEM and is carried out using ANSYS software. The selected results of FEM analysis (in particular parameters of the equivalent circuit of the transformer) are compared with the results of the laboratory measurements.The novel construction of the modular concentric transformer for power electronics is described and analyzed in the paper. Proposed design of the transformer is dedicated for high frequency (the best results are in the range of 500 kHz to 3 MHz). The transformer has two windings made of concentrically arranged, thin-walled pipes, formed as a multi-turn spiral and put into magnetic core. The primary (inner) turns are connected in series and secondary (outer) ones are connected in parallel. The transformer described in the paper has turn-to-tum ratio 2:1, but in general the turn ratio can be different. The transformer is of high efficiency (above 98%) and very high ratio of windings coupling (about 0,998). High power density (above 100 kW/kg) for output power about 5 kW is its additional advantage. The paper is focused on influence of the shape and arrangement of the windings and magnetic core on the transformer properties. The results of analysis (efficiency, output power and power density) determine optimal design of transformer with respect of relevant transformer parameters. The analysis is based on FEM and is carried out using ANSYS software. The selected results of FEM analysis (in particular parameters of the equivalent circuit of the transformer) are compared with the results of the laboratory measurements.
PL
W artykule przedstawiono sposób budowy i analizę nowej współosiowej konstrukcji transformatora modularnego. Konstrukcja ta przeznaczona jest do pracy przy wysokiej częstotliwości (najlepsze właściwości w zakresie 500 kHz do 3 MHz). Uzwojenia transformatora wykonane z cienkościennych współosiowych rur, uformowane w kształcie spirali, umieszczone są wewnątrz rdzenia magnetycznego. Zwoje pierwotne (wewnętrzne) połączone są szeregowo, natomiast zwoje wtórne (zewnętrzne) równolegle. Opisywany transformator posiada przekładnię zwojową 2:1. Charakteryzuje się wysoką sprawnością (około 98%), bardzo wysokim współczynnikiem sprzężenia uzwojeń (powyżej 0,99) oraz bardzo dużą gęstością mocy (powyżej 100kW/kg) przy mocy wyjściowej około 5 kW. Artykuł skupia się na analizie wpływu rozmieszczenia i kształtu uzwojeń na właściwości transformatora. Analiza przeprowadzona została w oparciu o metodę elementów skończonych. Wybrane elementy analizy porównano z wynikami eksperymentu laboratoryjnego.
first rewind previous Strona / 1 next fast forward last