Purpose: in this article, virological analysis was used to detect SARS-Cov-2 RNA in municipal sewage. As part of the work obtained comparatively with current epidemiological data to assess, or in terms of the indicator of the impact of COVID-19, municipal sewage can be a representative medium for assessing the health status of residents, sewage catchment. Methodology: The research used the physicochemical analysis method using a set of research techniques used in chemistry and related sciences, which allow for determining the physical and chemical properties of substances. Result: based on the obtained results of physicochemical parameters of wastewater, it can be concluded that the quality of wastewater has a significant impact on virus RNA concentration, which directly affects the sensitivity, viability and reproducibility of the SARs-CoV-2 virus in the same volume of analyzed wastewater. Originality: research groups around the world have begun analyzing wastewater for a new indicator that can estimate the total number of infections in a given community. Scientists have already shown that there is a correlation between the concentration of SARS-CoV-2 RNA in wastewater and the number of identified clinical cases of COVID-19. They also suggest that monitoring RNA concentrations can provide information about cases of infection 4-7 days in advance, and thus provide an early warning system or identify sources of serious infections.
The article presents the key provisions of the new European Parliament directive on municipal wastewater treatment, outlining the directions in which wastewater treatment technologies will need to advance. In line with the principles of the circular economy, municipal wastewater should be regarded as a source for water recovery, raw materials, and energy, both from the wastewater itself and from waste generated during its treatment processes. The quality parameters of treated wastewater necessitate the adoption of increasingly effective technologies for the removal of carbon compounds and nutrients, employing both biological and chemical methods. The elimination of micropollutants, such as pharmaceuticals and microplastics, will require the introduction of an additional treatment stage within municipal wastewater treatment plant systems, incorporating specific processes such as oxidation, adsorption, or filtration. The efficiency of their removal depends primarily on the chemical structure of the pollutants and their resultant physicochemical properties. Another critical aspect of municipal treatment plant operation is energy self-sufficiency and the sustainable management of sewage sludge. In this regard, treatment plants must reduce the energy consumption of technological processes and prioritise the acquisition of energy from renewable sources, including the utilisation of sludge as biofuel. Sewage sludge should also be considered a source of valuable elements, with potential for resource recovery. In light of these considerations, municipal wastewater treatment plants are evolving into production facilities that use sewage as a raw material, with increasingly high processing efficiency and improved removal of both conventional and emerg-ing pollutants. Modern technologies and legal regulations are driving the implementation of such targeted technological solutions.
Edukacja społeczeństwa i promowanie technologii odzysku ciepła ze ścieków na różnych etapach jest niezwykle istotne w dobie szukania nowych źródeł energii. W artykule nakreślono podstawowe zagadnienia związane z odzyskiem ciepła ze ścieków komunalnych oraz przedstawiono kilka przykładów realizacji tego typu projektów.
5
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Możliwości wykorzystania surowców pozyskiwanych ze ścieków komunalnych do produkcji systemów GRP zgodnie z zasadami gospodarki o obiegu zamkniętym i strategią zrównoważonego rozwoju.
EN
The possibilities of using raw materials recovered from urban wastewater for the production of GRP systems in accordance with the principles of circular economy and sustainable development strategy.
6
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Pierwsza europejska dyrektywa ściekowa została przyjęta w 1991 r., gdy najważniejszym celem gospodarki ściekami komunalnymi było redukowanie emisji biogenów do środowiska. Jej efekty środowiskowe są niekwestionowane, mimo, że jest kosztowna i generuje w państwach członkowskich wiele kontrowersji, trudności i opóźnień. Jednak postęp naukowy, technologiczny oraz zmiany w środowisku spowodowały, że ponad trzydziestoletnia dyrektywa musiała ulec gruntownemu przekształceniu. Nowa dyrektywa ściekowa przegłosowana już została przez Parlament Europejski i zostanie prawdopodobnie przyjęta przez Radę pod koniec 2024 roku. Wówczas nastąpi etap jej transpozycji do polskiego prawa oraz wdrażanie, które ma się zakończyć w 2045 roku. W porównaniu do aktualnej dyrektywy stawia przed Unia Europejską wiele nowych wyzwań, takich jak ograniczanie emisji z sektora usług kanalizacyjnych czy poszerzony monitoring ścieków.
EN
The first European urban wastewater treatment directive was adopted in 1991 when the most important goal of municipal wastewater management was to reduce the emission of nutrients into the environment. Its environmental effects are unquestionable, even though it is expensive and generates a lot of controversy, difficulties, and delays in the Member States. However, scientific and technological progress and environmental changes meant the over-thirty-year-old directive had to be thoroughly transformed. The new directive has already been voted on by the European Parliament and will probably be adopted by the Council at the end of 2024. Then, the stage of its transposition into Polish law and implementation will occur, which is expected to be completed in 2045. Compared to the current directive, it poses many new challenges to the European Union, such as reducing emissions from the sewage services sector and extending wastewater monitoring.
W wyniku działań organów Inspekcji Ochrony Środowiska oraz Policji ujawniane są nieprawidłowości w stosowaniu komunalnych osadów ściekowych. Gospodarka tak specyficznym odpadem wymaga wyjątkowej czujności, ciągłej weryfikacji i kontrolingu.
Analizy laboratoryjne nie muszą być trudne. Wystarczy przestrzegać kilku podstawowych zasad, aby dostać szybki i wiarygodny wynik, niezbędny do prawidłowego eksploatowania oczyszczalni ścieków.
Istotny wpływ na działanie osadników wtórnych mają nie tylko przyjęte parametry i wskaźniki technologiczne charakteryzujące pracę tych urządzeń, jak przepływ ścieków czy obciążenie powierzchni zbiornika osadem czynnymi. Często główną przyczyną złego funkcjonowania mogą by( zakłócenia pracy samych reaktorów biologicznych. Tylko optymalizacja pracy układu reaktor biologiczny - osadnika wtórny może zagwarantować uzyskiwanie wysokiej efektywności redukcji zanieczyszczeń w ściekach, które po oczyszczeniu odprowadzane do środowiska.
Instalacja wstępnego oczyszczania ścieków dowożonych, wyposażona we własne instalacje cieplną i elektryczną, dzięki hermetyzacji oraz niezależności energetycznej jest przyjazna środowisku i samowystarczalna. W Polsce jest to pierwsze tego typu rozwiązanie.
Miejskie ścieki odzwierciedlają styl życia populacji, od której pochodzą. Zarówno patogeny, jak i związki chemiczne/metabolity mogą być wydalane z moczem i kałem, trafiając do kanalizacji, a następnie do oczyszczalni ścieków. Chociaż pierwotnie epidemiologia oparta na ściekach była wykorzystywana do szacowania spożycia narkotyków wśród miejskich populacji, obecnie coraz większą rolę odgrywa w śledzeniu rozprzestrzeniania się chorób zakaźnych, a także chorób cywilizacyjnych, w tym w wykrywaniu obecności markerów chorób nowotworowych.
Treatment of Municipal wastewater by Electrocoagulation (EC) process using punched aluminium and zinc electrodes was studied in a batch EC cell reactor. Response surface methodology (RSM) based on Central Composite Design (CCD) was utilized to optimize the operating parameters for the removal of % Total Suspended Solids (TSS) and % Chemical Oxygen Demand (COD) from Municipal Sewage. Effect of operating parameters such as Electrode Distance (x1), Electrolysis Time (x2) and Voltage (x3) has been optimized for the removal of TSS and COD. The prediction of removal percentage of TSS and COD in various Operational circumstances is done by using Quadratic model. The significance of each operating parameter was computed by Analysis of variance (ANOVA). To achieve the maximum removal of % TSS and % COD, the optimum conditions were Electrode distance(x1)-3 cm, Electrolysis Time (x2)-70.299 minute and Voltage (x3)-6.5V. It was observed that the performance of electrocoagulation process increased up to 61.45% for COD removal, and 73.73% for TSS removal using punched electrode compared to plane electrodes.
18
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W artykule opisano problemy związane z wykorzystaniem ścieków komunalnych jako dolnego źródła pomp ciepła eksploatowanych w instalacjach ogrzewania budynków i przygotowania c.w.u. na potrzeby ich mieszkańców. Opisano różne technologie pozyskiwania ciepła ze ścieków oraz podano przykłady instalacji wykonanych w kilku miastach europejskich, przy czym szczególną uwagę zwrócono na konstrukcję wymienników ciepła ścieki/nośnik ciepła.
EN
The article describes the problems associated with the use of municipal wastewater as a lower source of heat pumps used in the buildings heating and preparation of a domestic hot water installations. Various technologies for extracting heat from wastewater are described and examples of installations made in several European cities are given, with particular attention paid to the construction of heat exchangers wastewater/heat medium.
19
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Do procesu oczyszczania ścieków komunalnych w biologicznych reaktorach filtracyjnych jako wypełnienie zastosowano odpadowy poli(akrylonitrylo-butadieno-styren) w postaci granulatu o wielkości frakcji 1,0–3,0 cm lub 0,4–0,8 cm. Oznaczano stopień redukcji ChZT, BZT5 oraz zawiesin w ściekach. Reaktory ze złożem zraszanym ściekami były efektywniejsze od napowietrzanych.
EN
The ABS waste material in the form of granules with a fraction size of 1.0–3.0 cm or 0.4–0.8 cm was used as a filling in the municipal wastewater treatment process in biological filter reactors. The degree of redn. of COD, BOD5 and suspended solids in sewage was detd. Reactors with a bed sprinkled with sewage were more effective than those with an aeration system.
Komisja Europejska podjęła decyzję o wniesieniu do Trybunału Sprawiedliwości UE sprawy przeciwko Polsce w związku z nieprzestrzeganiem dyrektywy dotyczącej oczyszczania ścieków komunalnych.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.