The integration of the disciplines of both the green operation and the complex supply chain (including purchasing, production and logistics) came into focus in the 1990s. In the literature review the focus of the researchers of this cross-sectional field was the automotive industry. It seems obvious that these closely-knit systems with high OEM dominance will offer more concrete results: it is difficult to resist when a given OEM starts to involve its first-, second- and third tier suppliers into its environmental schemes and processes. The Hungarian automotive sector can be characterized as somewhat one-sided: it consists of by few large international OEM’s (Audi, Mercedes-Benz, Opel, Suzuki, Raba), but by a large number of small-medium enterprises as 3rd (or even 4th!) tier suppliers. The aim of the paper was to find out whether companies acting as a member of more advanced chains show also better results in their “green” supply-chain-behavior. As a study description, in our empirical research, we have created a toolkit, and examined whether companies, which are using more sophisticated inter-organizational cooperation-tools, are more environmentally cautious, and if yes to what extent. As a result, discussion it can be stated that companies with a higher developed traditional Supply Chain have also a more developed green supply chain management system.
PL
Integracja dyscyplin, zarówno działalności ekologicznej, jak i złożonego łańcucha dostaw (w tym zakupów, produkcji i logistyki) w centrum uwagi znalazła się w latach dziewięćdziesiątych ubiegłego wieku. W przeglądzie literatury przedmiotem zainteresowania badaczy był przemysł motoryzacyjny. Wydaje się oczywiste, że te ściśle powiązane systemy o wysokiej pozycji dominującej wśród producentów oryginalnego wyposażenia(OEM), oferują bardziej konkretne wyniki: trudno jest oprzeć się sytuacji, kiedy dany producent zaczyna angażować swoich dostawców pierwszego, drugiego i trzeciego szczebla w swoje systemy i procesy środowiskowe. Węgierski sektor motoryzacyjny można scharakteryzować jako nieco jednostronny: składa się on z kilku dużych międzynarodowych producentów OEM (Audi, Mercedes-Benz, Opel, Suzuki, Raba), a także dużej liczby małych i średnich przedsiębiorstw jako dostawców trzeciego (lub nawet czwartego) poziomu. Celem artykułu było ustalenie, czy firmy działające jako członkowie bardziej zaawansowanych sieci wykazują również lepsze wyniki w swoich "zielonych" zachowaniach związanych z łańcuchem dostaw. W badaniach empirycznych stworzono zestaw narzędzi i zbadano, czy firmy, które używają bardziej wyrafinowanych narzędzi współpracy międzyorganizacyjnej, są bardziej ostrożne ekologicznie, a jeśli tak, to w jakim stopniu. Na podstawie przeprowadzonych badań, można stwierdzić, że firmy o bardziej rozwiniętym tradycyjnym łańcuchu dostaw mają również bardziej rozwinięty system zarządzania zielonym łańcuchem dostaw.
EN
Thermal analysis of a heat and power plant with a high temperature gas cooled nuclear reactor is presented. The main aim of the considered system is to supply a technological process with the heat at suitably high temperature level. The considered unit is also used to produce electricity. The high temperature helium cooled nuclear reactor is the primary heat source in the system, which consists of: the reactor cooling cycle, the steam cycle and the gas heat pump cycle. Helium used as a carrier in the first cycle (classic Brayton cycle), which includes the reactor, delivers heat in a steam generator to produce superheated steam with required parameters of the intermediate cycle. The intermediate cycle is provided to transport energy from the reactor installation to the process installation requiring a high temperature heat. The distance between reactor and the process installation is assumed short and negligable, or alternatively equal to 1 km in the analysis. The system is also equipped with a high temperature argon heat pump to obtain the temperature level of a heat carrier required by a high temperature process. Thus, the steam of the intermediate cycle supplies a lower heat exchanger of the heat pump, a process heat exchanger at the medium temperature level and a classical steam turbine system (Rankine cycle). The main purpose of the research was to evaluate the effectiveness of the system considered and to assess whether such a three cycle cogeneration system is reasonable. Multivariant calculations have been carried out employing the developed mathematical model. The results have been presented in a form of the energy efficiency and exergy efficiency of the system as a function of the temperature drop in the high temperature process heat exchanger and the reactor pressure.
EN
The jib luffing and slewing interlocks applicable to the ship deck crane are presented. The interlocks were provided to fix the crane jib without supporting it during sea voyage. The paper contains description of design and operation mode of the interlocks, assumptions to and results of their calculations and tests carried out at the manufacturer's twst station.