W artykule przedstawiono wyniki badań pomiarów temperatury złączą diody półprzewodnikowej zabudowanej w obudowie do montażu powierzchniowego (SOT–23), przy pomocy metody bezkontaktowej. Przedstawiono układ pomiarowy i otrzymane wyniki pomiarów oraz szczegółowe parametry diody użytej do badania. Omówiono zależność wiążącą temperaturę obudowy diody z temperaturą złącza, warunki panujące w trakcie wykonywania eksperymentu, oraz wnioski wynikające z otrzymanych wyników.
EN
Junction temperature is one of the most important parameters of semiconductor diode. Diode operation depends on this temperature, however its correct measurement is difficult because of small size of the object. Measurements are especially complex for SMT (Surface Mount Technology) diodes of size 1 to 3 mm. Application of a contact temperature sensor is inefficient. Thus, an alternative way is the noncontact thermovision measurement which can give information on temperature of the diode case. However, in practice information about diode semiconductor junction is more significant. Experimental studies of the relation between a result of diode case thermovision measurement and temperature of junction inside the case have been undertaken. BAT54C diode with two junctions in the same case for SMT was used. One junction was temperature sensor while another one operated as heater. It was found that the temperature difference was not higher than 9°C what allows us to conclude that thermovision measurement of diode junction temperature may be useful in diagnostic testing of electronic circuits.
2
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W pracy zaprezentowano wyniki badań eksperymentalnych dotyczących oddziaływania wahań napięcia zasilającego na stan wybranych impulsowych zasilaczy diod LED z wyjściami napięciowymi i prądowymi. Badania zrealizowano na skonstruowanym stanowisku laboratoryjnym wytwarzającym napięcie zasilające o zadawanej zmienności. Do generacji wahań napięcia zastosowano prostokątną modulację amplitudy o zadawanej głębokości i częstotliwości modulacji. Wpływ wahań napięcia na stan badanych zasilaczy określono dwiema metodami: na podstawie analizy przebiegów czasowych prądu wyjściowego (zasilającego diody LED) oraz wykorzystując subiektywną ocenę postrzegania migotania światła przez obserwatora.
EN
The paper presents result of experimental research the interaction of input voltage fluctuation on the state of selected LED switching power supply with constant-voltage and constant-current outputs. Research was realized on the designed measuring system for voltage fluctuation reconstructed by amplitude modulation on rectangular signal for selected frequency modulation. The influence of voltage fluctuation on the state of tested power suppliers was determined with two methods: on the basis of output current waveforms (supplying LEDs) and using the subjective assessment observer by flicker vision.
3
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Ocena jakości energii elektrycznej w sieciach elektroenergetycznych wykorzystuje zestaw wielkości normatywnych i uzupełniających. Wśród tych wielkości znajdują się dwie miary zawartości harmonicznych w napięciu: widmo amplitudowe oraz całkowity współczynnik odkształcenia THD. Pomiar oraz rejestracja parametrów służących do oceny jakości energii elektrycznej są wykonywane z wykorzystaniem przyrządów pomiarowych zwanych analizatorami jakości energii elektrycznej. W pracy zaprezentowano przykładowe wyniki badań wybranego analizatora z zastosowaniem programowalnego źródła napięcia przemiennego, przeprowadzonych na przygotowanym stanowisku pomiarowym.
EN
The electric power quality evaluation in electrical power networks is a complex measuring task carried out with the use of asset of standard and complementary quantities. Among these quantities two measures of harmonic content in voltage can be mentioned: spectrum amplitude and coefficient THD. The parameters dedicated to assess the power quality are measured and registered with the use of measurement devices called power quality analysers. Examples of the results of testing a selected power quality analyser with the use of programmable AC source in a prepared measuring system are presented in the paper.
4
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Jednym z podstawowych parametrów opisujących metodę obrazowania jest jej rozdzielczość. W pracy podjęto próbę wyznaczenia rozdzielczości i kontrastu proponowanej metody. W tym celu do przygotowanego fantomu jednorodnego wprowadzano zaburzenie absorpcyjne w postaci stalowych prętów o różnych średnicach. Przeszkody umieszczano w określonych konfiguracjach przestrzennych względem siebie. Pomiary powtarzano odtwarzając ułożenie prętów dla różnych grubości warstwy badanej (różnych poziomów cieczy).
EN
The resolution is one of the basic parameters describing the imaging method. This paper attempts to determine the resolution and contrast for the proposed method. Steel rods of various diameters were placed in the homogeneous phantom. The barriers were placed relatively to each other, in a specific spatial configuration. The measurements were repeated for different thickness of the tested layer (different levels of liquid).
W pracy przeprowadzono ocenę możliwości aplikacyjnych dwóch kamer CMOS w prześwietlaniu peryferyjnych części ciała. Wykonano badania porównawcze dwóch typów kamer, przyjmując metodykę pomiaru zgodną z przyjętym sposobem prześwietlania obiektów biologicznych w układzie docelowym. Badania przeprowadzono przy zastosowaniu kamer tego samego producenta różniących się charakterystyką widmową. Porównano wyznaczone charakterystyki widmowe z danymi katalogowymi producenta. Wyznaczono transmitancję widmową dwóch typów obiektywów. Porównano obiektyw o podwyższonej czułości w zakresie bliskiej podczerwieni z obiektywem przeznaczonym do pracy w zakresie widzialnym. Uzyskane charakterystyki widmowe odniesiono do przykładowej transmitancji optycznej śródręcza.
EN
In the paper the assessment of the possibility of using two CMOS cameras for transilluminating the peripheral body parts are presented. The comparative tests were performed for two camera types with the adoption of the measurement methodology similar to the transillumination of the perypherial body parts in a target circuit. Cameras of the same producer but with different spectral characteristics were used in the research. Spectral sensitivity characteristics obtained during the research are different from the ones provided in producer’s data sheets. There was also the spectral transmittance for two types of a lens delineated - the first lens with high sensitivity in the near infrared, the second intended for use in the visible range. The obtained results were related to a sample transmittance of the peripheral body parts of (for example metacarpus).
Źródłami promieniowania najczęściej stosowanymi w budowie symulatorów promieniowania słonecznego są lampy: halogenowe, metalohalogenkowe, ksenonowe oraz siarkowe. Znajomość widm promieniowania tych lamp jest warunkiem koniecznym dla poprawnego projektowania symulatora promieniowania słonecznego. Lampy ksenonowe charakteryzują się ciągłym widmem promieniowania w zakresie od 200 - 3000 nm, choć dokładny jego przebieg nie jest zawsze prezentowany przez wytwórców. W artykule opisane zostanie stanowisko pomiarowe do wyznaczania rozkładów widmowych lamp w zakresie od ultrafioletu do podczerwieni. Przedstawiona zostanie również procedura pomiaru widma optycznego spektrometrem. Omówione zostaną rozkłady widmowe lamp ksenonowych różnej mocy wyznaczone doświadczalnie i porównane zostaną z krzywymi przedstawianymi przez producentów w katalogach.
EN
Radiation sources typically used in solar simulators include: halogen lamps, metal halide lamps, xenon lamps, and sulfur lamps. Knowledge of spectral characteristics of these lamps is a necessary condition for the correct design of solar simulator. Xenon lamps are characterized by a continuous radiation spectrum in the range of 200 - 3000 nm, although the exact course of its is not always presented by the manufacturers. The paper described measuring position to determine the spectral distribution of the lamp from the ultraviolet to the infrared. The paper also presented a procedure for measuring the optical spectrum using the spectrometer. Spectral distributions of xenon lamps of different power, set experimentally, are discussed and compared with the curves presented by the producers in catalogs.
Parametry wyjściowe paneli fotowoltaicznych i kolektorów słonecznych zależą m.in. od poziomu natężenia napromienienia. Dostosowanie takich urządzeń do warunków panujących na danym terenie wymaga odtworzenia promieniowania słonecznego. W tym celu w warunkach laboratoryjnych powinny być wykorzystywane symulatory promieniowania słonecznego o rozkładzie widmowym dostosowanym do właściwości badanych urządzeń. Najczęściej stosowanymi źródłami promieniowania w tego rodzaju symulatorach są lampy: halogenowe, metalohalogenkowe, ksenonowe oraz siarkowe. Znajomość widm promieniowania tych lamp jest warunkiem koniecznym dla poprawnego projektowania symulatora promieniowania słonecznego. W artykule opisano stanowisko pomiarowe do wyznaczania wypadkowych rozkładów widmowych lamp ksenonowych i halogenowych. Przedstawiono procedurę pomiaru widma optycznego spektrometrem dla układu dwóch źródeł promieniowania. Otrzymane rozkłady widmowe poddano analizie.
EN
Output parameters, tested photovoltaic panels and solar collectors, depend on the level of irradiance therefore build new solar simulators allow to adapt these products to the conditions prevailing in the area. Radiation sources typically used in solar simulators include: halogen lamps, metal halide lamps, xenon lamps, and sulfur lamps. Knowledge of spectral characteristics of these lamps is a necessary condition for the correct design of solar simulator. The paper described measuring position to determine the cumulative spectral distributions of the halogen and xenon lamps from the ultraviolet to the infrared. The paper also presented a procedure for measuring the optical spectrum using the spectrometer for the team of two radiation sources. Received spectral distributions have been analyzed.
W artykule opisano stanowisko badawcze zdolności koordynacyjnych kończyn dolnych składające się z układu sterowania oraz z dwóch przyrządów: jednego przeznaczonego do przeprowadzania próby różnicowania ruchów i drugiego do badania równowagi statycznej, częstotliwości ruchów lokalnych i globalnych. Omówiono przebieg poszczególnych prób oraz określono końcowe wyniki pomiaru. Zwrócono uwagę na specyficzne cechy tego typu układów pomiarowych. Przedstawiono przykładowe wyniki badań.
EN
Football is one of the sports that requires proper coordination capabilities of the lower limbs. The evaluation of such capabilities, which must include limb asymmetry, is required at each stage of the training. The evaluation is a basis on which the load, intensity, and training means are selected. So far, such studies have been performed using a stopwatch, a ruler, and a wooden stand, the so-called t-bar. To facilitate the research and improve the reliability of the results, a specialized test stand was built. The design process was aimed at simplicity of the resulting instruments. There were also taken into account available financial resources. This paper describes the research test stand for lower limb coordination capabilities. It consists of a control system and two devices, one for trial of movement differentiation and the other for trials of static balance, as well as local and global movement rate. The operator manages the course of attempts using a PC with dedicated software. The paper discusses the course of each trial task and describes the measurement results. Some of the specific features of this type of measurement systems, visible only during the actual tests, are also mentioned. The basic functions of trials managing software are outlined. Moreover, the paper presents the measurement results obtained from tests of lower limb coordination capabilities.
Prześwietlanie optycznie mętnych obiektów biologicznych jest zada-niem trudnym. W artykule przedstawiono wyniki prześwietleń ręki. Opisano transmisję promieniowania optycznego w zakresie 500–1500 nm. Wyznaczono okna transmisyjne oraz oszacowano wartość optycznego sygnału wyjściowego z prześwietlanego obiektu. Przedstawiono schemat blokowy stanowiska do rejestracji obrazów transiluminacyjnych. Zamieszczono przykładowe obrazy transiluminacyjne poddane wstępnemu przetwarzaniu i analizie.
EN
Transillumination of turbid biological objects is a difficult task. The easiest way to obtain a transillumination image is through observation of the illuminated object with a camera. The paper presents the results of hand transillumination. The transmission of optical radiation (in the 500-1500 nm wavelengths range) through the metacarpus is described. A method applied to optical transmittance measurements (Fig. 1) is discussed. Two transmission windows of 630-950 nm and 1000-1140 nm (Fig. 2) are found. The value of the transillumination optical output signal is estimated. The next part of the paper presents a block diagram of the hand transillumination image recording setup (Fig. 4) and the spectral characteristic of the emitter (Fig. 3). Sample transillumination images are also included. The problem of overexposure of the camera detector (Fig. 6) is pointed out. The images recorded during transillumination of a hand with three different wavelengths are presented. To improve the quality, one of the images has been processed with a Gaussian sharpening filter (Fig. 7). Based on the results of the analysis of the recorded test results it can concluded that it is purposeful to conduct further research to find optimal conditions of transillumination and algorithms which will allow to highlight information about the anatomical structure of tested body parts.
W artykule omówiono definicję wskaźnika ΔV10. Zaproponowano schemat blokowy miernika ΔV10 i wyznaczono jego równanie przetwarzania dla sinusoidalnej zmienności napięcia. Porównano wartości wskaźników ΔV10 i Pst. Prezentując wyniki porównań obu miar przybliżono możliwości diagnostyczne wskaźnika ΔV10. Odwołując się do zamieszczonych zależności ΔV10, Pst i ƒm wykazano, że dla zmienności napięć występujących w sieciach elektroenergetycznych niemożliwe jest przeliczanie jednej miary do drugiej.
EN
The ΔV10 index is a measure of voltage fluctuations in power grids proposed by the Japanese CRIEPI Institute [1] and used all over the Far East countries. European standards prefer Pst and Plt indicators in voltage fluctuation measurements [11]. The ΔV10 and Pst/Plt are different in terms of the characteristics of measurement signal chains [6]. Therefore the measures may be characterized by different diagnostic capabilities. This may lead to the situation where some receivers may be described as faultless while voltage fluctuations are acceptable for one measure and may be described as faulty with the voltage fluctuations being unacceptable for the other measure. On the other hand, some level of uncertainty may appear as the influence of a receiver may be classified as obnoxious with the use of one measure and not-obnoxious with the use of the other. The paper includes analytical determination of the ΔV10 index value dependency on the voltage fluctuation reproduced with a sinusoidal amplitude modulation (Eq. (2)). The calculations have been made for the assumed signal chain model of a ΔV10 index measuring instrument (Fig. 3). The values of ΔV10 and Pst indexes at a given sinusoidal voltage fluctuation have been compared (Figs. 4-6). On the basis of the obtained ΔV10 and Pst dependencies on ƒm it has been assumed that for the voltage fluctuations present in power grids of unknown type and frequency it is impossible to convert one measure into the other.
W artykule przedstawiono wyniki badań transiluminacyjnych śródręcza z użyciem dwupunktowego źródła promieniowania optycznego. W pierwszej części pracy omówiono specyfikę transiluminacji takich obiektów oraz warunki badań. Następnie zamieszczono uzyskane wyniki transiluminacji dla diod LED o różnych charakterystykach widmowych. Zaobserwowano, że obraz transiluminacyjny w dużym stopniu zależy od wzajemnego położenia diod LED i silnie pochłaniających elementów prześwietlanego obiektu.
EN
The optical turbidity of biological objects related to the scattering and absorption properties of particular tissue elements makes it difficult to transilluminate them with optical radiation. In the paper the results of transillumination studies of the metacarpus are presented. Experimental studies were realized to determine a suitable configuration of the two-point source of optical radiation in order to transilluminate peripheral body parts. The specificity of transillumination of such objects and conditions to study them in the arrangement: LED - the tested object - CMOS camera are described (Fig. 2). The results obtained for LEDs of different spectral characteristics are shown (Figs. 3, 6-8). The results of measurements are given with changes in the pixel intensity as a function of its location in the transillumination image. We made an attempt to interpret the influence of the location of the applied point sources of radiation on the results of transillumination (Fig. 5). It can be supposed that this image depends significantly on the mutual position of LEDs and the strongly absorbing elements of the transilluminated object. This relationship can make location of the particular components of the object very difficult. However, it seems to be probable that taking into account the mutual position of a LED and an object in the analysis of transillumination images will facilitate location of such elements as e.g., blood vessels.
Most often, solar radiation simulators are built with a certain lamp type - halogen, xenon, metal halogen or, less frequently, sulphur lamps. The knowledge of radiation spectra of these lamps is a prerequisite to correctly design a solar radiation simulator. On many occasions, two lamps used simultaneously provide better adjustment of the simulator's radiation to solar radiation. This is especially beneficial in case of simulators dedicated to selected solar radiation receivers with specific sensitivity range, e.g. photovoltaic panels or solar collectors. The article presents the test bed and results of examination of summary spectral distributions of xenon and halogen lamp. Proper mixing of radiation of these lamps allows better adjustment of the simulator's radiation to the needs of a specific receiver of real solar radiation.
Do podstawowych składników oceny jakości energii elektrycznej należą wielkości charakteryzujące zmienność napięcia w sieci elektroenergetycznej. Należą do nich miary przeznaczone do oceny uciążliwości wahań napięcia i wspierające identyfikację źródeł zmienności napięcia. W pracy przedstawiono porównanie trzech najczęściej używanych miar: maksymalnych Umax i minimalnych Umin wartości skutecznych napięcia, wskaźnika krótkookresowego migotania światła Pst oraz wskaźników wahań napięcia. W części specyfikującej poszczególne miary (uzupełnionej o wskaźnik ΔV10) zamieszczono ich krótkie opisy. W głównej części pracy omówiono zależność wybranych miar wahań napięcia od częstotliwości fm sygnału modulującego amplitudę i częstotliwość. Sformułowano obserwacje określające możliwości diagnostyczne poszczególnych miar. Ze względu na złożoność problematyki miar wahań napięcia praca nie wyczerpuje zagadnienia. Jest tylko jednym z etapów pogłębiania wiedzy o miarach wahań napięcia.
EN
Voltage fluctuation measures in power network are the basic components of the evaluation of power quality. These measures include among other the measures designed to assess the voltage fluctuations obnoxiousness and to support the identification of the sources of voltage variation. The paper presents a comparison of three mostly used measures: the Umax maximum and Umin minimum value of the true RMS voltage, short-term flicker index Pst and indicators of voltage fluctuations, i.e. δU amplitude and f frequency. Each measure is briefly described in a part specifying the particular measures which has been supplemented by the ΔV10 indicator. The main part of the paper discusses a relationship between the selected voltage fluctuation measures and the modulating amplitude and frequency signal fm frequency. Conclusions which define the diagnostic capabilities of particular measures, were formulated. Due to the complexity of the voltage fluctuations measurements, this work does not exhaust the problem. It is only one of the stages to broaden the knowledge about the measures of the voltage fluctuations.
Similarly to a number of other quantities, those describing voltage variation make it possible to provide a complete assessment of the quality of electrical energy. Voltage variation may be described by measures used to assess the obnoxiousness of voltage fluctuations or measures that help indicate the source of fluctuations. The paper provides a comparison of the three most popular measures: the Umax maximum and Umin minimum rms voltage values, the Pst short-term flicker indicator, and voltage fluctuation indicators. The part that specifies the particular measures (including an additional description of the ∆V10 indicator) also contains their short descriptions. The main part of the dissertation describes the dependence of the voltage fluctuation measures on the frequency of the fm amplitude and frequency modulating signal. Observations drawn allow to specify the diagnostic capabilities of particular measures. Due to the complexity of voltage fluctuation measures’ studies the paper deals with only a certain aspect of it and should be concerned as a step to understanding the idea of voltage fluctuation measures.
15
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The paper discusses a set of the most frequently used measures of voltage fluctuation, which are useful in searching for disturbing loads. A procedure appropriate for searching the loads causing voltage fluctuation is proposed. The procedure utilizes two measures of fluctuation: Pst indicator as well as minimal and maximal values of voltages and currents. An analysis is included of four exemplary measuring results, recorded in a LV network. The effect of this analysis is a conclusion whether a disturbing load appears or not. The first Example illustrates the state in which it was possible to designate a disturbing load. The other Example shows a situation in which an unequivocal conclusion is impossible. In Examples 3 and 4 it was found that the loads under investigation are not dominant sources of voltage fluctuation. By means of the hereby analysis of measurement data the authors prove the diagnostic potential of the proposed procedure for searching for disturbing loads.
PL
W pracy zestawiono najczęściej stosowane miary zmienności napięcia, pomocne w poszukiwaniu odbiorników niespokojnych: wskaźnik Pst, wskaźniki wahań napięcia, wartości maksymalne i minimalne wartości skutecznej napięcia oraz wskaźnik ΔV10. Zwrócono uwagę¸ na możliwości diagnostyczne wartości maksymalnych i minimalnych prądu. Zaproponowano metodę¸ postępowania podczas poszukiwania odbiorników wywołujących zmienność napięcia wykorzystującą¸ wskaźnik Pst oraz wartości maksymalne i minimalne napięcia i prądu. Metodę¸ te¸ zilustrowano z wykorzystaniem czterech przykładowych wyników pomiarów zarejestrowanych w sieci elektroenergetycznej niskiego napięcia. Efektem analizy wyników pomiarów było wnioskowanie o występowaniu bądź nie odbiornika niespokojnego. Pierwszy przykład obrazuje stan, w którym możliwe było wytypowanie niespokojnego odbiornika. Przykład drugi pokazuje sytuacje¸, w której niemożliwe jest jednoznaczne wnioskowanie. W przykładach trzecim i czwartym stwierdzono, że badane odbiorniki nie są dominującymi źródłami napięcia. Za pomocą zamieszczonej analizy danych pomiarowych wykazano możliwości diagnostyczne przedstawionego sposobu poszukiwania odbiorników niespokojnych.
In the paper, investigations of semiconductor diodę heating to be observed by a rrmovision camera are presented. The presented results are given as time varying waveforms of temperature recorded for the diode case during its heating .
The influence of the foil shutters on temperature measurements using thermovision cameras was studied. Measurements were carried out in laboratory conditions. The thickess of a polyethylene foil used in experiments was between 0,028 mm to 0,16 mm. Based on the received results of measurements, the scaling coefficient describing a relationship between the indicated and reference temperature was presented.
W artykule opisano w uproszczony sposób proces odczuwania przez człowieka migotania światła. Zamieszczono wyniki przeprowadzonych laboratoryjnych badań widzenia migotania. Stwierdzono, że zależność widzenia migotania światła od częstotliwości jest przedziałami niemonotoniczna, a częstotliwości najbardziej widocznego migotania światła nie zależą od jego barwy. Odwołując się do modelu miernika migotania, zwanego potocznie flickermetrem, wykazano, że odczuwalne migotanie może występować w sieci elektroenergetycznej dla wahań napięcia o częstotliwości do około 150 Hz.
EN
In the paper, a simplified description of the process of flicker observing by people is presented. The results of the author's own laboratory studies are discussed. A relationship between flicker observing and frequency is nonmonotonic, and frequency values of the most visible flicker do not depend on light color. Referring to the flickermeter model, it was shown that the observed flicker can occur in power network at the voltage fluctuations of frequency equal up to about 150 Hz.
19
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The purpose of the work is to present specific and difficult problems connected with scientific investigations and education in the interdisciplinary field what there is biomedical engineering. In our Division of Metrology and Optoelectronics, research works are combined with teaching duties. Our investigations in biomedical engineering are mainly based on utilization of light-tissue interaction. Interests include research and developing of measuring systems, evaluation of the uncertainty of measurement results, and improvement of instrumentation used in biomeasurements. The conducted by us speciality Measuring Systems in Industry and Biomedical Engineering (SPPIB) is the interdisciplinary speciality offered to the students at Faculty of Electrical Engineering at PUT. The Engineer's and the Master’s programs of the speciality offer several courses enabling greater depth knowledge and practical experience to students.
20
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W pracy przedstawiono cztery miary zmienności napięcia w sieci elektroenergetycznej: wskaźnik krótkookresowego migotania światła Pst, wskaźniki wahań napięcia [delta]U i f, wartości maksymalne Umax i minimalne Umin napięcia oraz wskaźnik [delta]V10. Wymieniono podstawowe cechy tych miar. Graficznie zobrazowano zależności wartości tych miar od zmienności napięcia. Na podstawie wyników pomiarów zarejestrowanych w obwodzie nn przeprowadzono przykładową ocenę zmienności napięcia. Wykorzystując wartości Umax i Umin przyjęto, że zarejestrowane zmiany napięcia, wzrosty i zaniżenia, nie powinny być przyczyną zakłóceń w pracy odbiorników. Jednak duże wartości różnic (Umax-Umin) zwróciły uwagę na możliwość wystąpienia dużej zmienności napięcia. Analizując przebieg czasowy Pst = f (t) wykryto wystąpienie uciążliwych wahań napięcia w jednej fazie. Na tej podstawie stwierdzono niezachowanie jakości energii elektrycznej w ujęciu prawnym i normatywnym. Określono wartości wskaźników wahań napięcia: amplitudy [delta]U i częstości f.
EN
The paper presents four measures of voltage variability in power grid: a short-term flicker Pst indicator, voltage fluctuation [delta]U and f indices, maximum Umax, and minimum Umin rms voltage values as well as [delta]V10 index. The basic features of these measure were listed. Dependences of these measures values on voltage variability were graphically depicted. An exemplary voltage variability assessment was conducted basing on the measurement results recorded in the low-voltage circuit. In the example, using the Umax and Umin values, it was stated that the recorded changes of voltage, its rises and falls, should not be causing interference in the work of receivers. However, large values of (Umax-Umin) differences drew an attention to the possibility of occurrence of large voltage variability. Analysis of Pst = f(t) time plot confirmed the occurrence of obnoxious voltage fluctuation in one phase. This was the basis to the final statement that the voltage quality failed to meet legal and normative requirements. Moreover, the values of voltage fluctuation indices [delta]U and f were determined. In this way it was able to estimate the properties of source of voltage variability.