The present paper proposes a CFD model to study sulphur dioxide (SO2) absorption in seawater. The focus is on the treatment of marine diesel engine exhaust gas. Both seawater and distilled water were compared to analyze the effect of seawater alkalinity. The results indicate that seawater is more appropriate than distilled water due to its alkalinity, obtaining almost 100% cleaning efficiency for the conditions analyzed. This SO2 reduction meets the limits of SOx emission control areas (SECA) when operating on heavy fuel oil. These numerical simulations were satisfactory validated with experimental tests. Such data are essential in designing seawater scrubbers and judging the operating cost of seawater scrubbing compared to alternative fuels.
2
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Opracowanie prezentuje aktualny stan prawny ochrony powietrza przed odorami w Polsce. Zaprezentowano także różne technologie oczyszczania powietrza zawierającego związki odorowe na terenie komunalnych oczyszczalni ścieków i w systemach kanalizacji sanitarnej. Przedstawiono konkretne obiekty w Polsce, na których zastosowano różne technologie oczyszczania powietrza złowonnego z opisem parametrów i zdjęciami urządzeń. Zarysowano kierunek rozwojowy aplikowanych technologii. Zwrócono uwagę, że dwustopniowe technologie oczyszczania powietrza a szczególnie z użyciem złóż biologicznych zraszanych są technicznie atrakcyjne i kosztowo efektywne nie tylko inwestycyjnie ale również w eksploatacji w porównaniu chociażby z oczyszczaniem za pomocą skruberów chemicznych (przykład takiego rozwiązania z USA gdzie podjęto działania w kierunku zamiany na złoża biologiczne zraszane).
EN
This study presents the current legal status of air protection against odors in Poland. Were presented different air cleaning technologies in municipal wastewater treatment plants. Contains concrete objects in Poland with description and photographs. Shows the direction of technology development. The two stages technology with using bio-trickling filters were determined to be the most cost-effective control technology for treating the exhaust air from different places in wastewater treatment plants. The selection of bio-trickling filters met the goals of using a control technology that is “green”, uses no chemicals, generates no hazardous residuals, has relatively low costs and requires low maintenance (such as the USA, where attempts to convert chemical scrubbers for bio-trickling filters).
The article presents review of available biogas upgrading technologies to natural gas quality, as well as Polish achievements in this field. Article also took into account the national requirements relating to quality of biogas delivered to the natural gas network, as well as quality requirements for biogas in other European countries on the example of Germany. The paper discusses two new and perspective methods of upgrading biogas.
PL
W artykule przedstawiono przegląd dostępnych technologii oczyszczania biogazu do jakości gazu ziemnego oraz polskich osiągnięć w tej dziedzinie. Opisano również krajowe wymogi dotyczące jakości biogazu wprowadzanego do sieci gazu ziemnego, a także wymagania jakościowe dla biogazu w innych krajach europejskich na przykładzie Niemiec. Omówiono dwie nowe perspektywiczne metody oczyszczania biogazu.
4
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
An experience gained in the closed aluminum smelter in Sibenik (Croatia) is described in order to highlight possible similar problems anywhere in the world, when commercial wet-scrubber, designed for fresh water, is used in an unconventional seawater environment. Lime treatment process was used to remove fluoride as an insoluble calcium fluoride. Wet-scrubbing in real system is compared with that in model system, using the SOLGASWATER program (ERICSSON, 1979) for heterogeneous equilibria. It is shown that chemical modelling can help to control the wet-scrubbing process and thus to avoid the undesirable breaking of pipelines. The removal of fluoride at pH 5.4 in the form of insoluble cryolite, using lime slurry process and seawater in recirculation, is suggested to be an alternative to precipitation of calcium fluoride. Environmental consequences of partial discharging aluminum and fluoride into the marine environment are discussed in comparison with ecosystem response to volcanic aerosol.
5
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The results of the model calculations of SO2 absorption in spray absorber and in impinging-stream scrubber have been presented. The results of investigation have confirmed the assumption that intensification of the absorption occurs in impinging-stream scrubbers. A significant absorption activation was observed on an impinging-streams level, where droplet hold-up and mass transfer surface are greatest.
PL
W pracy porównano wyniki obliczeń modelowych absorpcji SO2 w absorberze natryskowym oraz absorberze ze zderzającymi się strugami cieczy (skruberze zderzeniowym). Uzyskane wyniki potwierdzają, że zastosowanie zderzających się strumieni cieczy intensyfikuje proces absorpcji. Istotne przyspieszenie tego procesu zaobserwowano w strefie zderzenia strug cieczy, gdzie zatrzymanie kropli i powierzchnia kontaktu międzyfazowego są największe.
7
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The paper presents the equation representing the dependence of such parameters as: gas cleaning efficiency in scrubber, a pollutant concentration in an inlet gas stream, an initial pollutant concentration in liquid being dosed to the scrubber, a pollutant concentration in a liquid flowing out from apparatus, a ratio of sprayed liquid volume stream to gas volume stream, and circulation number of sprayed liquid in apparatus on an actual gas cleaning efficiency in plant.
PL
Podano równanie opisujące zależność rzeczywistej skuteczności oczyszczania gazów odlotowych w instalacji od skuteczności oczyszczania gazów w skruberze, stężenia usuwanego zanieczyszczenia w gazach na wlocie do skrubera, początkowego stężenia zanieczyszczenia w cieczy podawanej do skrubera, unosu kropel tej cieczy z aparatu natryskowego, stosunku strumienia objętości rozpylanej cieczy do strumienia objętości oczyszczanych gazów i krotności tej cyrkulacji w obiegu tego aparatu
8
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Selected results of air dedusting process carried out in a large-laboratory horizontal cocurrent spray scrubber are presented. An experimental equation describing the influence of sprayed liquid volume stream to gas volume stream ratio and the efficiency of inertial separation of dust particles of a given size of single droplet on flue gas dedusting interval efficiency was derived. The influence of gaseous phase velocity and spraying rate on total dedusting efficiency was also determined.
PL
Podano wybrane wyniki badania procesu odpylania powietrza w wielkolaboratoryjnym poziomym współprądowym skruberze natryskowym oraz równanie doświadczalne, określające zależność przedziałowej skuteczności odpylania gazów w tym aparacie od stosunku strumienia objętości rozpylanej cieczy do strumienia objętości odpylanego powietrza i sprawności inercyjnego wydzielania cząstek pyłu określonego rozmiaru na pojedynczej kropli. Określono również wpływ prędkości fazy gazowej i gęstości zraszania na całkowitą skuteczność odpylania.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.