Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 17

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Slab-column connection is one of the most critical points in reinforced concrete structures. Punching shear capacity of this connection must be properly determined in both the persistent design situation and the accidental design situation of fire. European and American codes give simplified (tabulated) requirements for minimal slab thickness and minimal column cross-section width in accordance with the required fire resistance. In many cases, a more accurate prediction of fire resistance might be needed. It can be achieved when the ultimate limit states of a structure are checked in the case of fire conditions. This paper shows the comparison between European and American code requirements for punching shear capacity as the base for further calculations of flat RC slabs subjected to fire. The second part is going to present European and American requirements for determining the effects of loads relevant to the consideration of an accidental design situation of fire and comparing these effects with the punching shear capacity of the slab-column connection, which decreases with fire duration.
PL
Zapewnienie nośności na przebicie połączenia płyta-słup jest jednym z kluczowych etapów projektowania konstrukcji budynków żelbetowych, również z uwagi na warunki pożarowe. Zarówno w europejskich, jak i amerykańskich normach do projektowania konstrukcji są podane uproszczone (tabelaryczne) wymagania dotyczące minimalnej grubości płyt stropowych oraz minimalnej szerokości przekrojów słupów w zależności od wymaganej klasy odporności ogniowej. Jednak w przypadku projektowania budynków o szczególnym znaczeniu lub dużym zagrożeniu bezpieczeństwa ludzi, w wielu przypadkach konieczne może być dokładniejsze określenie odporności ogniowej konstrukcji. Można to osiągnąć, weryfikując stany graniczne nośności konstrukcji w warunkach pożarowych. W pierwszej części artykułu przedstawiono porównanie wymagań norm europejskich i amerykańskich w zakresie nośności stropu na przebicie oraz wyniki obliczeń nośności na przebicie dla typowych, stosowanych w praktyce inżynierskiej grubości stropów i wymiarów słupów, narażonych na działanie wysokiej temperatury. W drugiej części artykułu przedstawione zostaną wymagania norm europejskich i amerykańskich w zakresie określania oddziaływań w wyjątkowej sytuacji pożaru oraz porównanie efektów tych oddziaływań z nośnością stropu na przebicie, która zmniejsza się w trakcie trwania pożaru.
PL
W artykule przedstawiono wyniki badań krótkotrwałych i reologicznych przyrostu odkształceń w teście wypychania (push-out test) w przypadku dwuzakładkowych połączeń klejonych. Łącznie przebadano 15 próbek złożonych z elementów wykonanych z drewna klejonego krzyżowo (CLT) oraz prefabrykowanych płyt betonowych. Połączenie między elementami wykonano jako klejone z użyciem innowacyjnych prefabrykowanych złączy podatnych o grubości 3 mm, w trzech konfiguracjach powierzchni klejenia. Celem badań było określenie wpływu geometrii połączenia klejonego na początkowy przyrost odkształceń w czasie. Wykazano, że pełzanie przebiega nieliniowo w czasie t1 = 800 s niezależnie od powierzchni klejenia, a następnie zwiększa się w sposób liniowy. W przeprowadzonych badaniach złączy pasmowych uzyskano przyrost początkowego pełzania o ok. 10% mniejszy w przypadku złączy ułożonych w kierunku obciążenia niż w kierunku prostopadłym. Wykazano również, że wartości pełzania nie są wprost proporcjonalne do wielkości naprężenia ścinającego.
EN
This paper presents the results of a study of short-term rheological strain increments in a push-out test for double-lap glued joints. A total of 15 specimens consisting of cross laminated timber (CLT) elements and precast concrete slabs were tested. The joint between the elements was made as a glued joint using innovative 3 mm thick prefabricated flexible joints in three bonding configurations. The aim of the study was to investigate the influence of the adhesive joint geometry (type A with 600 cm2 glue, B - 200 cm2 in strips parallel to the load axis and C - 200 cm2 in strips in the perpendicular direction) on the initial deformation increase over time. Creep phenomenon was shown to be nonlinear for an initial time range of t1 = 800 s regardless of the adhesive area, and then to increase in a linear manner. In the tests carried out on strip joints, the increments of initial creep were obtained to be about 10% smaller for joints arranged in the load direction than for those arranged in the perpendicular one. It was also shown that the creep values are not directly proportional to the magnitude of the shear stress.
PL
Szacuje się, że sektor budowlany odpowiada za około 50% globalnej emisji dwutlenku węgla oraz zużycia zasobów naturalnych, a także olbrzymią ilość odpadów składowanych na wysypiskach. Konieczne stało się zatem znacznie silniejsze zaangażowanie naszej grupy zawodowej w realne zmiany proekologiczne. Idea budownictwa o obiegu zamkniętym stwarza ogromne możliwości dekarbonizacji, szczególnie jeśli rozważane jest ponowne użycie strunobetonowych elementów prefabrykowanych. W referacie omówiono możliwości ponownego wykorzystania już wbudowanych stropów ze sprężonych płyt kanałowych, jak i zasady projektowania nowych, uwzględniającego przyszły demontaż i ponowny ich montaż. Drugie życie płyt kanałowych jest możliwe, co zostało już potwierdzone praktycznymi realizacjami w Holandii, Szwecji czy Finlandii.
EN
The construction sector contributes to approximately 50% of global carbon dioxide emissions and natural resource consumption, along with generating a significant amount of landfilI waste. Thus, there is an urgent need to actively involve our professional community in fostering real environmental change. Embracing circularity in construction presents significant opportunities for decarbonization, particularly in the context of prestressed precast concrete structures. This paper explores the potential for reusing prestressed hollow core slabs already built-in, as well as the principles of designing for future dismantling and reassembly. A second life for hollow core slabs is possible, as has already been confirmed by practical realisations in the Netherlands, Sweden and Finland.
PL
Stropy wykonane ze sprężonych prefabrykowanych płyt kanałowych wykazują zdolność do współpracy w przenoszeniu obciążeń skupionych. Współpracę zapewniają złącza monolityczne między prefabrykatami oraz sztywność skrętna płyt. Uwzględnienie współpracy między prefabrykatami pozwala na zredukowanie obciążenia w bezpośrednio obciążonym elemencie, co przekłada się na możliwość redukcji wytężenia elementu w stanie granicznym nośności (SGN) w znacznie wyższym stopniu niż wówczas, gdy strop rozpatruje się jako wydzielony element wolnopodparty. Analizy porównawcze zapisów normy europejskiej EN 1168 oraz modeli analitycznych dotyczące współpracy między prefabrykatami prowadzą do niejednoznacznych, nierzadko sprzecznych wyników. Na podstawie wcześniejszych analiz numerycznych, których poprawność zweryfikowano względem istniejących danych eksperymentalnych, zbudowano modele numeryczne, które posłużyły do zaplanowania nowych, unikatowych badań na stropach w pełnej skali. Wyniki analiz przedstawiono w artykule, skupiając się na zachowaniu się stropu w SGN, a otrzymane siły niszczące porównano z wynikami otrzymanymi w modelu płyty pojedynczej oraz z wynikami obliczeń normowych.
EN
Precast prestressed hollow core floors are able to distribute concentrated loads due to the presence of cast on site joints and torsional stiffness of individual units. By considering this phenomenon in design, the directly loaded element is able to withstand loads much higher than in case of a single element analysis. The current design method provided by European Standard EN 1168 as well as different analytical methods can provide results that do not fully represent the actual performance of the floor. Due to that fact that a sparse amount of experimental data on full scale floor exists, out of which just a handful is documented well, the results of code provisions and analytical models are difficult to evaluate. Based on previous numerical analyses, validated by existing experimental data, numerical models of three hollow core floors were prepared which were used to design new experiments on full scale hollow core floors. Analysis focuses on the Ultimate Limit State of the HC floors, obtained failure loads are compared to single element results and with the results of the EN 1168 standard calculations.
5
PL
W pracy krótko przedstawiono i porównano dostępne metody pomiaru sił sprężających w istniejących konstrukcjach betonowych. Opisano badanie przeprowadzone na kablobetonowej prefabrykowanej belce podsuwnicowej, zdemontowanej z istniejącej konstrukcji po ponad 55 latach użytkowania. Przedstawiono wyniki pomiaru siły sprężającej metodą niszczącą i seminiszczącą, które porównano z obliczoną wartością siły według Eurokodu 2. Poszczególne metody określenia siły sprężającej wykazały zadowalającą zgodność.
EN
The paper briefly presents and compares available measuring methods of a prestressing force in existing concrete structures. A description of the prestressing force tests carried out on a post-tensioned precast concrete crane girder, dismantled from an existing structure after more than 55 years of service, is given. The results of the prestressing force measurements by destructive and semi-destructive methods are presented and compared with the calculated value of the force according to Eurocode 2. The different methods of determining the prestressing force have shown a satisfactory consistency.
PL
W pracy przedstawiono wybrane aspekty projektowania stropów z płyt HC, obciążonych siłą skupioną, w świetle obowiązującej normy EN 1168 oraz licznych publikacji. Przeprowadzono analizę porównawczą, w której obliczeniową nośność płyty porównano z wybranymi badaniami eksperymentalnymi takich stropów, przeprowadzonymi w Fińskim Instytucie Technicznym. Wykazano wiele niejasności i wątpliwości co do sposobu obliczania elementów pracujących w złożonym stanie naprężenia, które wciąż wymagają naukowego wyjaśnienia.
EN
The article presents selected aspects related to the design of hollow core slab units that are able to distribute concentrated loading to adjacent slabs. Provisions of EN 1168 as well as literature are presented and discussed. A comparative analysis has been performed in which calculated capacity of a slab has been compared to selected experimental results obtained from slab field tests done in Technical Research Centre of Finland. The outcome of analysis illustrated various ambiguities and questions that correspond to the state of the art knowledge regarding the considered subject.
7
PL
Stropy prefabrykowane zyskują coraz większą popularność we współczesnym budownictwie, przede wszystkim z uwagi na ich szybką realizację. Jednakże zapisy norm dotyczących projektowania stropów są często niejednoznaczne, a czasami wątpliwe. W artykule omówiono wybrane zagadnienia projektowania stropów z płyt kanałowych, które często sprawiają problemy w praktyce projektowej, podając odwołania do odpowiednich badań naukowych w tym zakresie. Szczególną uwagę poświęcono zasadom dystrybucji obciążenia skupionego na sąsiednie płyty w polu stropowym, wykonywania otworów w stropach, zagadnieniom podparcia stropu oraz uwzględniania tarczowej pracy płyty stropowej.
EN
Precast floors are gaining more and more popularity in modern construction, mainly due to their fast realization. However, the provisions of standards regarding floor design are often ambiguous and sometimes questionable. The article discusses selected issues of HC slabs design, which often pose problems in practice, with references to relevant scientific research in this field. Particular attention was paid to the principles of distribution of the concentrated load on adjacent slabs in the floor field, openings in the floors, support conditions and taking into account the slab function as an element of a floor.
EN
Half a century after the dominance of Brutalist architecture, the majority of discussions about these buildings concern their continued existence. Sadly today, there is more talk about the demolition of Brutalist buildings than about their protection and preservation. And yet, many Brutalist buildings expressed a progressive vision of community living and sustainable public ownership. The effort to preserve them, therefore, is not merely a fight to defend heritage, but also the idea that through the necessary process of adaptive reuse, maintenance, and preservation of existing buildings, the trend of constant “replacement of the fabric of the building” should be halted. In the era of seeking “sustainable” solutions in architecture, this kind of re-evaluation of the meaning of Brutalism and its concrete matter seems to be more than a will to preserve the legacy of the past. One may say that restoring or even prolonging the life of these valuable reinforced concrete structures, primarily in the form of properly selected protection of the concrete surface, is the core of activities aimed at their conservation.
PL
Pół wieku dominacji architektury brutalistycznej sprawiło, że dyskusję o takich realizacjach zdominowała kwestia dalszego ich istnienia. Niestety, obecnie więcej się mówi o wyburzaniu budynków brutalistycznych niż o ich ochronie i zachowaniu. Należy jednak pamiętać, że wiele obiektów brutalistycznych prezentowało nader istotną w połowie XX wieku ekspresję postępowej wizji życia społecznego i zrównoważonej własności publicznej. Trud ich zachowania nie jest więc jedynie walką o obronę dziedzictwa formalnego, lecz także ochroną konkretnej kulturowej idei. Poprzez konieczny proces readaptacji, utrzymania i zachowania istniejących budynków, należy położyć kres trendowi ciągłego „wymieniania tkanki zabudowy”. W erze poszukiwania „zrównoważonych” rozwiązań w architekturze ten rodzaj ponownej ewaluacji znaczenia brutalizmu i jego materii betonowej zdaje się czymś więcej niż wolą zachowania spuścizny przeszłości. Można powiedzieć, że rewaloryzacja lub przedłużanie życia tych cennych żelbetowych obiektów, głównie w formie odpowiednio dobranej ochrony ich betonowych powierzchni, jest podstawą działań zmierzających do ich konserwacji.
9
Content available remote Prefabrykacja betonowa - zrównoważone rozwiązanie dla budownictwa
PL
Prefabrykacja betonowa przyczynia się do przyspieszenia procesu budowlanego, poprawy jakości obiektu, optymalnego wykorzystania właściwości poszczególnych materiałów, a także lepiej wpisuje się w ograniczenia związane z szeroko rozumianą ochroną środowiska. Budownictwo realizujące strategię zrównoważonego rozwoju powinno cechować się przede wszystkim zmniejszonym zużyciem zasobów naturalnych, materiałów i energii, możliwością ponownego wykorzystania obiektu lub jego elementów konstrukcyjnych, a także odzyskiwania materiałów i surowców. W artykule przedstawiono liczne zalety prefabrykacji w kontekście koncepcji budownictwa o obiegu zamkniętym, realizującej najważniejsze cele zrównoważonego rozwoju.
EN
Precast concrete contributes to speeding up the construction process, improving the quality of the building, making optimum use of the properties of individual materials and better complying with the constraints of the wide-ranging environmental protection. Sustainable construction should be characterized primarily by reduced consumption of natural resources, materials and energy, the possibility of reusing a building or its structural elements, as well as recovering materials and raw materials. The numerous advantages of prefabrication in the context of the "circular building" concept, which realizes the most important sustainable development goals, are presented in the paper.
PL
Artykuł koncentruje się na wybranych aspektach statycznej pracy prefabrykowanych sprężonych płyt wielokanałowych wspartych na wspornikach elastycznych, tzw. struktury typu Slim Floor. Pierwsza część przedstawia zarys historyczny pojawienia się i rozwoju różnych rodzajów stalowych, betonowych i stalowo-betonowych belek zespolonych, wykorzystywanych w prefabrykowanych płaskich stropach, dla których wysokość belki jest tylko nieznacznie większa niż nominalna wysokość płyt. Opisano ponadto ogólną procedurę obliczania wytrzymałości na ścinanie płyt wielokanałowych według zaleceń fib. Wytrzymałość na ścinanie płyt wielokanałowych jest znacząco zredukowana przez odkształcenie poprzeczne systemu płyt stropowych w wyniku odchylenia wiotkiej belki.
EN
The paper is focused on selected aspects of static work of prestressed precast hollow core slabs supported on flexible supports, so-called Slim Floor structures. The first part presents a historical review of the emergence and development of various types of steel, concrete and steel-concrete composite beams, used in precast flat floors, for which the height of the beam is only slightly bigger than the nominal height of the slabs. A general procedure for calculating the shear capacity of hollow core slabs according to the fib recommendations is also described. The shear capacity of hollow core slabs is significantly reduced by the transverse deformation of the floor slab system due to the deflection of the slender beam.
11
Content available remote Najnowsze kierunki rozwoju stropów betonowych
PL
Przegląd najnowszych światowych innowacji w dziedzinie stropów pokazuje, że obecnie motorem dalszych poszukiwań są potrzeby odciążania konstrukcji, łatwego rozprowadzania wszelkich typów instalacji w grubości stropu, a także wykorzystanie konstrukcji stropowej do poprawy komfortu użytkowania pomieszczeń. W artykule omówiono i podano przykłady możliwych sposobów osiągania takich celów zarówno w stropach z prefabrykatów betonowych, jak i wykonywanych na miejscu budowy.
EN
An overview of the latest global innovations in the field of floor slabs shows that current driver for behind further exploration are the need to relieve the structure, easy distribution of all types of installations in the ceiling thickness, as well as the use of floor structure to improve the comfort of rooms’ use. The paper discusses and gives examples of possible ways of achieving such goals both in slabs made of precast concrete elements as well as those made on the construction site.
12
Content available remote Nowe rozwiązania stropów prefabrykowanych
PL
Stropy betonowe stanowią zdecydowaną większość ze wszystkich typów stropów realizowanych na świecie. Nie wymagają one dodatkowych zabezpieczeń przeciwpożarowych lub okresowych zabiegów konserwacyjnych, jakim podlegają chociażby elementy stalowe, co czyni je tańszymi w eksploatacji. Przy wykonywaniu stropów z betonu coraz powszechniej zaczynają być wykorzystywane betony specjalne, a także technologia sprężania. Chęć odciążenia konstrukcji jest motorem poszukiwań możliwości wykorzystywania kruszywowych betonów lekkich w konstrukcjach stropowych. Bardzo ciekawą wydaje się być perspektywa wykorzystywania w prefabrykacji betonowej drobnoziarnistych betonów wysokowartościowych ze zbrojeniem tekstylnym z włókien węglowych, które pozwalają na nieporównywalnie mniejsze przekroje poprzeczne elementów niż obecnie realizowane są w technologii tradycyjnego żelbetu.
EN
Concrete floors constitute the vast majority of all types of floors erected worldwide. They do not require additional fire protection measures or periodical maintenance work that is necessary in the case of steel components, thus reducing the cost of their exploitation. Special concretes and prestressing technology are increasingly common in the production of concrete floors. The desire to de-load the structure is the driving force behind looking for ways of applying light-aggregate concretes in floor production. The application of fine-grain high performance concretes with textile carbon fibres reinforcement in concrete prefabrication processes seems an interesting solution, allowing for incomparably smaller cross-sections of the used elements than the components currently used in the traditional reinforced concrete technology. Although innovations in the area of on-site RC construction are not uncommon, prefabrication still constitutes a technology that is the most open to creating and implementing new and unconventional solutions in the construction industry.
13
Content available Stropy zespolone z desek strunobetonowych
PL
Producenci prefabrykatów betonowych oferują wiele rozwiązań częściowo lub w pełni prefabrykowanych stropów, z których każde lepiej spełnia swoje funkcje w jednych warunkach użytkowania obiektu, a gorzej pracuje w innych zastosowaniach. Zalety, jakie niesie ze sobą prefabrykacja, są coraz częściej dostrzegane przez wszystkich uszestników procesu budowlanego, w tym również przez producentów chcących zaspokoić nacisk ze strony rynku budowlanego na opracowanie nowszych, lepszych i bardziej hybrydowych rozwiązań, tak aby możliwa była konkurencja z technologią tradycyjną wznoszenia obiektów, czyli betonem monolitycznym. Na Politechnice Krakowskiej zaproponowano wykonanie stropu ze strunobetonowych elementów nieznacznej grubości do zastosowania jako szalunku traconego dla zbrojonego nadbetonu [9, 10] wykonanego z betonu lekkiego. Powstały strop zespolony byłby stosunkowo tani w transporcie i montażu, co czyni go konkurencyjnym dla popularnych w budownictwie mieszkaniowym stropów gęstożebrowych, jednocześnie posiadając zalety stropów pełnych – dobre właściwości mechaniczne i akustyczne. W pracy przedstawiono zmodyfikowaną koncepcję takiego stropu, wykorzystującą jako nadbeton lekki beton kruszywowy, wraz z wybranymi wynikami analizy obliczeniowej.
EN
Precast concrete manufacturers offer many solutions of partially or fully precast slabs, each of which performs better in one site usage conditions, and works worse in other situations. The advantages of precast structures are increasingly noticed by all participants of the construction process, including producers who want to satisfy the pressure from the construction market to develop newer, better and more hybrid solutions, so that competition with traditional concrete technology is possible. On Cracow University of Technology Scientists proposes making a slab made of pre-tensioned concrete elements of low thickness for use as shuttering for reinforced concrete made of lightweight concrete [9, 10], which is lighter than conventional traditional concrete by about 30%. The resulting composite slab of precast elements would be relatively cheap in transport and assembly, which makes them competitive for popular ribbed floor structures usually used in houses, at the same time having the advantages of solid slabs, such as good mechanical and acoustic properties. The work presents the modified concept of such slab and an example of analysis.
15
Content available remote Projektowanie konstrukcji sprężonych wg Eurokodu 2. Cz.4.
EN
It is established fact that the initial prestressing force applied to concrete member continuously decreases with a time. The proper determining of level of prestressing force at each loading stage - from the moment of transter of the force to the concrete, to the different stages at service load, up to the ultimate - is very important. The reduction of prestressing force may be divided into two groups: immediate loses and lime-dependent loses. The rules for the adoption of the initial force and description of the immediate losses of the prestressing force are given in the paper.
16
Content available remote Projektowanie konstrukcji sprężonych wg Eurokodu 2. Cz.3
EN
Effective prestressing of the structure can be achieved by using very high-strength steel. Prestressing steel is characterized by high tensile strength, the lack of a defined yielding point, much smaller deformability and slightly lower modulus of elasticity than mild steel, relatively low relaxation, good fatigue resistance and high sensitivity to corrosion and temperature influence. In the article the design model of prestressing steel, given in Eurocode 2, is presented. In particular, the importance of proper consideration of relaxation losses in prestressing steel is highlighted.
17
Content available remote Prefabrykowane stropy żelbetowe i sprężone. Współczesne rozwiązania
EN
Structural solutions for building structures using prefabricated concrete elements are still very popular, which may be indicated by the size of the global construction output in precast technology. The subject of the greatest interest, among the items made in precast plants (also in Poland), are reinforced and prestressed floor systems. Selected recent, and most commonly used in building practice, solutions for residential, public and industrial buildings are given in this paper. The aim of the Authors of this article is to encourage the environment of investors, architects and civil engineers to use a wide range of new solutions in prefabricated floors, especially those made of prestressed concrete.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.