Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 131

Liczba wyników na stronie
first rewind previous Strona / 7 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  Eurocode
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 7 next fast forward last
EN
The paper presents a stability analysis of a municipal waste landfill lined by a single-drainage and mixed sealing layer. The drainage layer is medium-dense sand, while the mixed sealing layer consists of compacted stiff highly plastic clay and a synthetic barrier in the form of a double-sided textured HDPE geomembrane. Beneath a sealing, there is a non-woven geotextile with drainage and protective functions. The landfill was assumed as a sub-level in the excavation, where the maximum height of the waste is equal to the height of the excavation slope. Variable geometrical parameters of the municipal landfill were assumed, such as the height, the width and the inclination of the waste body. The structure stability analysis was performed using the GEO5 numerical programme. The calculations were carried out several times, looking for the most unfavourable slope surface. The considerations were conducted for checking the state of equilibrium (stability) according to design approach 3 (DA3) of Eurocode 7, approved according to the Polish National Annex and accepted in most CEN countries, and according to approach 1 (DA1) and 2 (DA2) adopted in other CEN countries. The values of the degree of utilization (utilization factor) for the ultimate limit state GEO according to Eurocode 7 were given. Stability calculations were also made considering the values of safety factors, i.e., using the characteristic values of parameters and actions. The values of the utilization factors achieved in all design approaches and the safety factor were compared.
PL
W pracy przedstawiono analizy stateczności odpadów komunalnych składowanych na składowisku podścielonym warstwą drenażową i mieszaną warstwą uszczelniającą. Warstwę drenażową stanowi piasek średni w stanie zagęszczonym, natomiast mieszaną warstwę uszczelniającą buduje zagęszczona glina zwięzła oraz geosyntetyczna bariera w postaci dwustronnie teksturowanej geomembrany PEHD. Pod uszczelnieniem znajduje się geowłóknina o funkcji drenażowej i ochronnej. Składowisko przyjęto jako podpoziomowe w wykopie, gdzie maksymalna wysokość składowania odpadów jest równa wysokości skarpy wykopu. Założono zmienne parametry geometryczne masywu odpadów komunalnych, takie jak wysokość, szerokość korony masywu oraz jego nachylenie. Analizę stateczności konstrukcji wykonano z wykorzystaniem programu numerycznego GEO5 (moduł Slope Stability), uwzględniając metody równowagi granicznej: Felleniusa/Pettersona, Bishopa, Spencera, Janbu i Morgensterna-Price’a, przy założeniu kołowej powierzchni poślizgu. Rozważania przeprowadzono zgodnie z podejściem 3 (DA3) Eurokodu 7 według polskiego załącznika krajowego i akceptowanego w większości krajów CEN oraz według podejść 1 (DA1) i 2 (DA2) przyjętych w innych krajach CEN. Podano wartości stopnia wykorzystania (współczynnika wykorzystania) dla stanu granicznego nośności GEO według Eurokodu 7. Obliczenia stateczności wykonano także z uwzględnieniem wartości współczynników bezpieczeństwa, tj. wykorzystując charakterystyczne wartości parametrów i oddziaływań. Porównano wartości współczynników wykorzystania uzyskanych we wszystkich podejściach projektowych oraz współczynniki bezpieczeństwa.
EN
The dynamic interaction between high-rise structures and environmental actions-particularly wind and seismic actions has remained a fundamental challenge in structural engineering for decades. This review critically examines the evaluation of modeling approaches, design standards, and analytical tools related to lateral load prediction and structural response in reinforced concrete high-rise buildings from 2000 to 2025. Drawing on over two decades of peer reviewed publications, Eurocode developments, and advancements in computer-aided structural analysis, the study traces the conceptual and practical shifts in how wind and seismic forces are understood static models toword performance-based and dynamic analysis using tools such as SAP2000, ETABS and TOWER. Key developments covered include the refinement of wind tunnel simulation data, probabilistic seismic hazard assessments, coupling of soil-structure interaction model, and the integration of damping mechanisms into design. The review also evaluates how modern guidelines (e.g., EN 1998, EN 1991-1-4, EUROCODE, ASCE 7, JUS) have evolved in response to empirical findings and catastrophic events (e.g., earthquakes in Turkey, Chile, Japan; extreme windstorms in Europe and Asia). This paper concludes by identifying future research directions, including the role of AI-assisted optimization, climate-adaptive design, and the integration of resilience-based frameworks for urban high-rise development. The review serves as a comprehensive resource for researchers and practicing engineers seeking to understand the trajectory of structural design methodologies for tall buildings in the face of increasing environmental uncertainty
EN
In this work, reinforced concrete frame buildings (frame structures), with 5 to 30 floors were analyzed in order to determine how the dominant design load shift with increasing building height, The study focuses on the identification of the number of floors where the controlling variable load moves with the gravity-inducted (own and live) load on lateral forces (wind and seismic forces) and examines the implications of this shift on the dimensioning of structural elements. Using computer models in software ETABS/TOWER and applying EUROCODE standards (EN 1991 for permanent and EN 1992 for concrete design), a series of buildings with only a central reinforced concrete core (surrounding elevator shafts and staircases) and without additional shear walls was evaluated under combined load scenarios. The analysis identifies a critical building height (within 5- to 30-storey range) where loads begin to govern design, replacing gravity loads as the primary driver for column sizing and reinforcement requirements. The results show that below this threshold height, column design is determined by vertical loads, with cross-sectional requirements increasing towards the lower floors due to accumulated gravity loads. Above the threshold, in taller buildings, lateral displacement and stability requirements dominate the design. This change loads to a significant increase in the required column dimensions and reinforcement – especially in the lower floors – to meet the strength and stiffness criteria. The transition in dominant loading significantly affects the distribution of internal forces and the amount of reinforcement required along the height of the building. These findings highlight the importance of recognizing the height at which lateral loads become critical in the design process, as they implicitly affect material utilization and structural efficiency in frame structures of medium and high-rise buildings.
PL
W artykule przedstawiono propozycję obliczania użebrowanych podstaw słupów, uwzględniającą założenia przyjęte w eurokodach. Procedura bazuje na zgodności przemieszczeń charakterystycznych punktów podstawy słupa i fundamentu. W strefie ściskanej przyjęto plastyczny rozkład naprężeń w betonie oraz towarzyszące mu graniczne odkształcenia zgodnie z Eurokodem 2, w strefie zaś rozciąganej uwzględniono deformacje podstawy słupa na podstawie współczynników sztywności podanych w Eurokodzie 3. Przedstawiono przykład obliczeniowy oraz porównano wyniki z programem IdeStatica bazującym na metodzie składnikowej i analizie MES.
EN
The article presents a proposal for the calculation of column bases with stiffeners, taking into account the assumptions made in the Eurocodes. The procedure is based on the compatibility of the displacements of the characteristic points of the column base and the foundation. In the compression zone, the plastic distribution of stresses in concrete and the accompanying limit strains were assumed in accordance with Eurocode 2, while in the tension zone the deformations of the column base were taken into account based on the stiffness coefficients given in Eurocode 3. A calculation example is presented and the results are compared with the IdeStatica program based on the component method and FEM analysis.
PL
W artykule dokonano przeglądu wybranych norm i standardów w zakresie nośności murów istniejących, obciążonych sejsmicznie z płaszczyzny. Szczególny nacisk położono na podane metody szacowania parametrów wytrzymałościowych muru, zalecenia dotyczące badań i inspekcji oraz konsekwencje przyjętego stopnia szczegółowości diagnostyki obiektów. Analizie poddano również kompletność zaleceń i ich wykonalność z inżynierskiego punktu widzenia. Skonfrontowano również zapisy normowe z dostępnymi wynikami badań doświadczalnych i opracowanych na ich podstawie wniosków.
EN
Article presents overview of chosen standards and codes in terms of seismic out-of-plane capacity of existing masonry walls. Particular attention was paid to methods of assessment of mechanical parameters, guidelines regarding testing and inspection, and consequences of diagnostics level. Also the completeness and feasibility of provided recommendations in terms of engineering practice is discussed. Standards are also confronted with available experimental data and scientific conclusions.
PL
Celem programu badań było porównanie wyników oznaczania wytrzymałości na ściskanie i wytrzymałości na rozciąganie uzyskanych podczas procedur badawczych zapisanych w Polskich Normach oraz zaleceniach Międzynarodowego Towarzystwa Mechaniki Skał (ISRM). Łącznie wykonano 130 eksperymentów jednoosiowego ściskania, punktowego obciążania oraz poprzecznego ściskania (tzw. testów brazylijskich) na próbkach skalnych wykonanych z granitu, wapienia i piaskowca. Właściwości geometryczne próbek dobierano w zależności od stosowanej metody badawczej, a następnie analizowano zależności między smukłością próbki i jej kształtem a uzyskanymi wartościami wytrzymałości na ściskanie i rozciąganie. Wyniki badań wykazały, że uzyskiwane w laboratorium wartości wytrzymałości na rozciąganie i na ściskanie silnie zależą od smukłości próbki, której różne wartości narzucają rożne normy i zalecenia ISRM, przy czym wrażliwość ta była znacznie większa w przypadku wytrzymałości na ściskanie. Badania wykazały także wątpliwą przydatność tzw. testu punktowego obciążania do wyznaczania wytrzymałości skały na ściskanie i ewentualnego szacowania jej wytrzymałości na rozciąganie.
EN
The aim of the test program was to compare the results of determining the compressive strength and tensile strength of some rocks, obtained by means of strength tests conducted according to the test procedures written in Polish Standards and in the recommendations of the International Society of Rock Mechanics (ISRM). In total, 130 experiments of uniaxial compression test, point load test and transverse compression test (so-called Brazilian test) were carried out on rock samples made of granite, limestone and sandstone. Geometrical properties of samples were selected depending on the applied research method. The relationships between the sample’s slenderness and its shape and the obtained values of compressive and tensile strength were analyzed The test results showed that the values of tensile and compressive strength obtained in laboratory tests strongly depend on the slenderness of the sample, the different values of which are imposed by different standards and ISRM recommendations, but the sensitivity was much higher in the case of compressive strength. The research also showed the questionable usefulness of the point load test for determining the compressive strength of a rock and for possible evaluation of its tensile strength.
PL
Opisano różnice między podejściem europejskim a amerykańskim w sposobie wymiarowania prętów z kształtowników giętych na zimno. Podano rezultaty obliczeń osiowo ściskanego ceownika. Otrzymane wyniki porównano z wynikami badań laboratoryjnych.
EN
This article shows differences between European and American methods of cold-formed section resistance calculations. Theoretical basis of both methods and calculation results of C-section axial compression are given. Computational analysis is compared with laboratory experiment.
8
Content available remote Façade scaffolding behaviour under wind action
EN
The main objective of the study was to estimate the mean horizontal wind action on a façade scaffolding on the basis of full-scale data. Measurements of climatic parameters were carried out for a number of façade scaffoldings (120 structures) located in Poland over a 30-month period. The measurement points were located on 2–3 deck levels of each structure and at 2–4 points placed in each level. The measurements were carried out 3–4 times during each day for 5 consecutive days. At each point, two components of wind speed were measured: first with the vane probe directed perpendicular to the façade and then parallel to the façade. Each measurement lasted 60 s, and the data were recorded every 1 s. On the basis of wind speeds, a procedure was suggested that enabled estimation of the static wind action on façade scaffoldings. The responses of structures to this action were computed via FEM simulations. The results were compared with those based on the approaches recommended by the wind and scaffolding codes. Initial analyses, illustrated by three scaffoldings without a protective cover, indicated large discrepancies between the approaches and the possibility of wind action, which is not considered in the codes.
PL
Polska jako kraj członkowski UE była zobowiązana do wprowadzenia w życie od 1 kwietnia 2010 r. tzw. Eurokodów, tj. norm europejskich do projektowania konstrukcji budowlanych. Podstawową normą do projektowania obiektów mostowych wg Eurokodów jest norma PN-EN 1991-2 [1], opisująca obciążenia ruchome mostów.
EN
Poland, as an EU Member State, was obliged to implement from 1 April, 2010 the so called Eurocodes, i.e. European standards for structural design. The basic standard for designing bridge structures to Eurocodes is PN-EN 1991-2 [1], which describes traffic loads on bridges.
PL
Przedstawiono program opracowywania II generacji eurokodów. Omówiono nowe propozycje norm i zasadnicze zmiany wprowadzane w poszczególnych normach dotyczących konstrukcji metalowych i zespolonych stalowo-betonowych. Eurokody i hEN są podstawą projektowania, wykonywania i kontroli konstrukcji budowlanych i inżynierskich, zgodnie z obowiązującymi w Polsce przepisami i Rozporządzeniem (UE) nr 305/2011.
EN
The paper presents new work program for the second generation Eurocodes. The proposals for new standards and main changes in particular standards, for metallic and composite steel-concrete structures are explain. The Eurocodes and hEN are the basic requirements for design, execution and inspection of building and civil engineering structures, according to the Polish Rules and the Regulations (EU) No. 305/2011.
PL
Przewody są najistotniejszym elementem linii z punktu widzenia pełnionej funkcji, to jednak słupy, będące efektem wspólnej pracy inżynieria energetyka i konstruktora, są odpowiedzialne za powszechny wizerunek linii elektroenergetycznych. W artykule przedstawiono wieloletni wkład ENERGOPROJEKT-KRAKÓW SA w obszarze branży konstrukcyjnej związanej z konstrukcjami wsporczymi napowietrznych linii elektroenergetycznych.
EN
The cables are the most important element of a transmission line from the point of view of performed function, nevertheless the pillars, being the effects of joined efforts of power and construction engineers, are responsible for the general image of power lines. Presented is here the many years’ ENERGOPROJEKT-KRAKÓW SA contribution to develop design industry that deals with support structures of overhead power lines.
PL
Przedmiotem artykułu jest analiza porównawcza prowadzenia obliczeń statyczno-wytrzymałościowych prowadzonych zgodnie z polską normą oraz Eurokodami. Szczególną uwagę zwrócono na różnice w przyjmowaniu obciążenia eksploatacyjnego, na różne podejście obu systemów norm do wyznaczania współczynnika dynamicznego tego obciążenia oraz na przyjmowaną wytrzymałość betonu na ściskanie. Artykuł wskazuje, że istnieje możliwość redukcji dynamicznej oddziaływania ruchomego przyjmowanego zgodnie z Eurokodem.
EN
The article describes in detail differences between various assumptions made in the two systems. Particular attention has been paid to the live load, the dynamic amplification factor and the design value of concrete compressive strength. The article indicates that there is a possibility for a dynamic reduction in live loads according to Eurocodes. The results are acceptable. Moreover, the author has proposed the αcc coefficient value.
PL
Omówiono najistotniejsze postanowienia krajowe dotyczące projektowania konstrukcji żelbetowych na warunki pożarowe, wprowadzone w brytyjskich i niemieckich załącznikach krajowych do eurokodów. Różnice dotyczą wartości dominującego oddziaływania zmiennego, przyjmowanej do analiz dotyczących wyjątkowej sytuacji projektowej pożaru, projektowania słupów na warunki pożarowe za pomocą tablic, stosowania metody „Izotermy 500°C” oraz przewodności cieplnej betonu i wilgotności, przy której jest mało prawdopodobne jego odpryskiwanie termiczne.
EN
This paper discusses the most important requirements for structural fire design of reinforced concrete structures, which are introduced by British and German National Annexes to Eurocodes. The most important changes were introduced to principal variable load used in analyses of accidental design situation of fire, design of columns by tabulated data, using of the “500°C Isotherm” method, thermal conductivity of concrete and its moisture content when thermal spalling is unlikely to occur.
PL
Cegła to materiał prawdziwie autentyczny. Nie udaje innych materiałów i rozwiązań. Jest po prostu sobą. Pasuje do rozwiązań tradycyjnych i nowoczesnych a odpowiednio zastosowany przez architekta i dobrze wykonany przez budowniczego nadaje niezwykłego charakteru wielu obiektom.
EN
An experimental investigation was conducted on 30 CFST columns. An influence of the following factors on load-carrying capacity of the investigated columns was analyzed: the column slenderness (λ1 = 42, λ2 = 27 and λ3 = 15), the tube thickness (the reinforcement ratio was equal to 4% or 6%), the way of applying the load to CFST columns (through the concrete core or through the entire cross-section), the bond strength between a steel tube and a concrete core. The results of the experimental investigation let the author derive a practical method of determining load-bearing capacity of CFST columns. The Eurocode 4 provisions regulating composite steel and concrete structures design impose the minimum share of a steel tube in the cross-sectional area of a CFST column. This minimum share is the prerequisite for the Eurocode 4 to be applicable. It ranges from 0.5% to 6%. As the experimental research presented in the paper indicate, the CFST columns of such low reinforcement ratios can be also effective in carrying loads. The proposed method is a second order analysis based on stiffness, similarly as the calculation procedure for the ordinary reinforced concrete columns which is used in Eurocode 2. The experimental results prove the author's suggestion to be correct.
EN
This paper presents the results from the deterministic and probabilistic seismic analysis of the influence of center mass eccentricity to symmetric tall buildings. During the structural design process, the problems of the safety, reliability and durability of a single structural element as well as the entire structure from the point of view of its planned life cycle must be considered. The methodology of the seismic analysis of the reinforced concrete tall building structures on the base of deterministic and probabilistic assessment is presented. The possibilities of the utilization the LHS method to analyze the extensive and robust tasks in FEM is presented in the case of tall buildings with central core and columns system. The analysis of the seismic resistance of the structure was calculated in the ANSYS program.
PL
Przedstawiono wyniki deterministycznej i probabilistycznej analizy sejsmicznej wpływu ekscentryczności masy środkowej na symetryczne budynki wysokie. Podczas projektowania strukturalnego należy wziąć pod uwagę problemy bezpieczeństwa, niezawodności i trwałości pojedynczego elementu konstrukcyjnego, a także całej konstrukcji z punktu widzenia planowanego cyklu eksploatacji. Przedstawiono metodologię analizy sejsmicznej zbrojonych konstrukcji żelbetowych na podstawie oceny deterministycznej i probabilistycznej. Możliwości wykorzystania metody LHS do analizy rozbudowanych zadań w MES przedstawiono dla przypadków wysokich budynków z centralnym systemem rdzeni i kolumn. Analizę odporności sejsmicznej konstrukcji wykonano w programie ANSYS.
EN
Formulae for the deflection of two examples of isostatic systems (simply supported beam, cantilever) were derived, accounting for influence of distribution of bending moments on cracking and beam stiffness distribution, according to EC2. Numerical analysis of the problem for the same two examples as well as for two further hyperstatic systems was performed using an iterative FEM algorithm. The influence of nonuniformity of cracking on deflection and distribution of bending moments was shown to be negligible in typical practical design problems, therefore also an estimation of deflection on the basis of the distribution of bending moments and the value of the factor αk obtained from linear solution (before redistribution) is shown to be justified.
PL
Wyprowadzono zamknięte wzory na ugięcia dla dwóch przykładów układów statycznie wyznaczalnych (belka swobodnie podparta, wspornik), uwzględniając wpływ rozkładu momentów zginających na zarysowanie i rozkład sztywności belki, zgodnie z EC2. Wykorzystując iteracyjny algorytm MES, przeprowadzono numeryczną analizę zagadnienia dla tych samych schematów statycznych oraz dwóch przypadków układów statycznie niewyznaczalnych. Wykazano minimalny wpływ nierównomierności zarysowania na wielkość ugięcia i rozkład momentów zginających w typowych praktycznych zagadnieniach projektowych, a tym samym stwierdzono zasadność szacowania ugięć na podstawie rozkładu momentów i wartości współczynnika αk dla rozwiązania liniowego (sprzed redystrybucji).
PL
Właściwa ocena stateczności ogólnej elementu oraz prawidłowe wyznaczenie siły krytycznej i nośności z uwagi na wyboczenie prętów poddanych działaniu osiowej siły ściskającej decydują o poprawnym zaprojektowaniu ustroju prętowego. Opisane zagadnienia związane są z projektowaniem prętów ściskanych osiowo według Eurokodu 9, wykonanych z kształtowników aluminiowych. Prezentowany artykuł zwraca uwagę na różnice wynikające z niewłaściwego stosowania programów do wymiarowania konstrukcji aluminiowych w wypadkach, gdy programy nie zawierają procedur Eurokodu 9, a jedynie bazę danych materiałowych wyrobów aluminiowych.
EN
Adequate assessment of general stability of the element as well as appropriate determination of a critical force and load-bearing capacity due to buckling of bars subject to the impact of axial compressing force determine the appropriate designing of the bar system. The issues described in the article are connected with designing of axially compressed bars according to eurocode 9, made using aluminium shape sections. The article pays attention to the differences resulting from improper use of software for sizing aluminium constructions in cases where programmes do not include eurocode 9 procedures, and only a material database of aluminium products.
PL
Po omówieniu w poprzednim artykule z niniejszej serii tematów związanych z materiałami konstrukcyjnymi gruntowo-powłokowych obiektów ze stalowych blach falistych [4] kolejnym zagadnieniem jest zasypka gruntowa, która stanowi istotny element konstrukcyjny tych obiektów.
first rewind previous Strona / 7 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.