W artykule przedstawiono, opracowaną w ITR, konstrukcję przyrządu do pomiaru wysokiego napięcia. Omówiono wybrane problemy techniczne związane z zastosowaną metodą pomiarową.
EN
Device for high voltage measurement, worked out in Tele and Radio Research Institute is described in the paper. Selected technical problems concerning used measuring method were discussed.
The goal of the Nanocafe project is preparation of a new type of cold cathode based on nanocomposite material that is nanostructural carbonaceous film. A special high voltage direct current power supply was designed and constructed. This power supply is used to power and test nanocarbon electron emitters. This device consists of four sections, all with a common cathode. The range of output voltage is as follows: section HV I from 0 V to 20 kV, section HV II from 0 V to 12 kV, section HV III from 0 V to 5 kV and section LV from -200 V to 0 V. Maximal output current for each section is 5 mA. Output voltage and current is measured for each section separately. Due to the fact that the power supply is to be used for cold emission experiments it was constructed to be resistant to short circuit between any of outputs or between an output and common cathode.
PL
Celem projektu Nanocafe jest opracowanie nowego typu katody do zimnej emisji elektronów, wykonanej na bazie nanomateriatów węglowych. W ramach projektu został zaprojektowany i wykonany specjalny zasilacz wysokonapięciowy. To urządzenie jest wykorzystywane do zasilania i testowania emiterów elektronów wykonanych na bazie nanostruktur węglowych. Zasilacz składa się z czterech sekcji, wszystkie ze wspólna katodą. Napięcie wyjściowe poszczególnych sekcji jest następujące: sekcja WN II od 0 V do 20 kV, sekcja WN II od 0 V do 12 kV, sekcja WN III od 0 V do 5 kV, sekcja NN od -200 V do 0 V. Maksymalny prąd wyjściowy każdej sekcji wynosi 5 mA. Napięcie i prąd wyjściowy każdej sekcji jest mierzony oddzielnie. Ze względu na przeznaczenie zasilacza do eksperymentów z zimną emisją, został on wykonany tak, aby zwarcia pomiędzy wyjściami dowolnych sekcji nie powodowały uszkodzenia urządzenia.
W pracy omówiono badania emisji polowej dla katod wykorzystanych w konstrukcji lamp fluorescencyjnych oraz dla lamp, w których zamontowano te katody. Badania pokazały, że najsilniejsza emisja obserwowana jest dla katod o strukturze litej matrycy z kompozytu węglowego z nanorurkami wystającymi z wyrw w tej matrycy. Nanorurki w takiej matrycy rozmieszczone są rzadko, tzn. ich długość jest znacznie mniejsza od odległości między nimi.
EN
Field emission studies were performed for cathodes used in a construction of a fluorescent lamp and for lamps in which these cathodes were mounted. investigations exhibited that a most intensive emission is observed for a cathode that was composed of film basing on carbonaceous matrix in which carbon nanotubes are placed in a holes. These nanotubes are rarely distributed in the matrix what means that their length is much smaller than distance between them.
4
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
This paper traces early inquires on the nature of the work function (WF). Much attention was paid to the papers published by Einstein (1905), Richardson (1901), Jentzsch (1908), Debye (1910), Schottky (1914) and Langmuir (1916). Those authors assumed that the image force, introduced already by Thomson for macroscopic bodies, may be the main reason for the barrier at the metal surface. The formula derived by Schottky (1914) is still used for calculation of the lowering of the surface barrier in presence of an external electric field. In further development of surface physics, however, much emphasis was paid to the role of a dipole layer. However, at the end of 20th century the idea of the image potential as the main contribution to WF was restored by Brodie (1995) and subsequently improved by Halas and Durakiewicz (1998). In these theories a distance d from which the image force can be integrated is found from the uncertainty principle and from the length of spontaneous metallic plasma polarization, respectively. The last approach has appeared to be very useful in calculation of WF of conducting compounds and ionization potentials of metallic clusters.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.