The development of the interphase structure of polymer nanocomposites provides them with tribological properties difficult to obtain in traditional microfiller composites and microhybrid composites. In material solutions, it is preferable to modify the parameters of the material in order to obtain properties that are as close to the hard tissues of the teeth as possible. The aim of the study is to compare the wear resistance of new light-cured nanocomposites and to analyse the surface layer and structure before and after the wear process. Recently developed modern materials were selected for the study. In nanocomposites, G-aenial, G-aenial X FLO, and Essentia, an optimal structure was found in SEM images before and after wear, as well as low resistance to sliding friction and resistance to tribological wear. All tested composites were characterized by suitable properties for clinical applications.
PL
Rozwinięcie struktury międzyfazowej nanokompozytów polimerowych nadaje im właściwości tribologiczne trudne do uzyskania w tradycyjnych kompozytach z mikrowypełniaczami i kompozytach mikrohybrydowych. W rozwiązaniach materiałowych preferuje się taką modyfikację parametrów tworzywa, aby uzyskać właściwości najbardziej zbliżone do tkanek twardych zębów. Celem pracy jest porównawcza ocena odporności na zużycie nowych nanokompozytów utwardzanych światłem oraz analiza warstwy wierzchniej i struktury przed i po procesie zużycia. Do badań wytypowano nowoczesne materiały, które zostały opracowane w ostatnim czasie. W nanokompozytach G-aenial, G-aenial X FLO i Essentia stwierdzono w obrazach SEM jednorodną strukturę na etapie opracowania klinicznego oraz strukturę pozbawioną wyraźnych zarysowań, złuszczeń i wykruszeń po procesie zużycia, a także małe opory ruchu w tarciu ślizgowym i odporność na zużycie tribologiczne. Wszystkie badane kompozyty charakteryzowały się odpowiednimi właściwościami do zastosowań klinicznych.
The clinical functionality of the prosthesis structure consists of creating the most convenient conditions without any traumatic effects of chewing forces on the substrate and adapting it to the individual biomechanical exclusions of the stomatognathic system (SS). When transferring functional loads, the optimization of tribological features and the ability to absorb energy is an important design and material parameter. The aim is to evaluate acrylic plastics intended for prostheses in terms of resistance to wear and resistance to movement in sliding contact within the environment of artificial saliva and their ability to absorb energy. Based on the analysis of the test results, it can be pointed out that Vertex is a good material for partial and complete dentures. Villacryl demonstrated similar properties, with Probase and Probase O being slightly worse. The appropriate mechanical parameters of the materials used in the prosthesis allow the production of thin plates that accurately reproduce the prosthetic substrate and improve the patient’s comfort of use through such a fit.
PL
Funkcjonalność kliniczna konstrukcji protezy polega na stworzeniu najdogodniejszych warunków bezurazowego oddziaływania sił żucia na podłoże oraz dostosowania jej do indywidualnych wymuszeń biomechanicznych US. Przy przekazywaniu obciążeń czynnościowych istotnym parametrem konstrukcyjno-materiałowym jest optymalizacja cech tribologicznych oraz zdolność do pochłaniania energii. Celem jest ocena tworzyw akrylowych przeznaczonych na protezy w zakresie odporności na zużycie i oporów ruchu w kontakcie ślizgowym w środowisku sztucznej śliny oraz ich zdolności do pochłaniania energii. Na podstawie analizy wyników badań można wskazać, że Vertex jest dobrym materiałem do wykonywania protez częściowych i całkowitych. Zbliżone do niego właściwości posiadał Villacryl, a nieco gorsze Probase i Probase O. Odpowiednie parametry mechaniczne materiałów stosowanych na protezy pozwalają na wykonanie cienkich płyt, które dokładnie odwzorowują podłoże protetyczne i poprzez takie dopasowanie poprawiają pacjentowi komfort użytkowania.
Prosthetic crowns reproduce the damaged hard structures of the patient’s own teeth and take over their natural functions, thus securing the correct reconstruction of the stomatognathic system. The aim is to evaluate the crowns for premolars and molars produced by casting, milling, and Selective Laser Melting technologies, in terms of the accuracy of reproducing the degree against the prosthetic pillar, the analysis of the surface layer structure of the step, and the micromechanical parameters of the alloy. The study material included CoCrMo alloy crowns. The conducted study allowed finding that the tightness of prosthetic crowns made using traditional casting technology as well as in SLM milling and technology is comparable and meets clinical requirements. Structural crown analyses confirmed the very good quality of the surface layer obtained with milling technology and SLM technology using the CAD/CAM method. SLM and digital milling allow the formation of precise and durable structures constituting the foundation of crowns in a time much shorter than the casting process.
PL
Korony protetyczne odtwarzają uszkodzone twarde struktury zębów własnych pacjenta, przejmują ich naturalne funkcje i w ten sposób zabezpieczają prawidłową odbudowę układu stomatognatycznego. Celem jest ocena koron na zęby przedtrzonowe i trzonowe wytwarzane technologią odlewania, frezowania oraz Selective Laser Melting, w zakresie: dokładności odwzorowania stopnia względem filara protetycznego, analizy struktury warstwy wierzchniej stopnia, parametrów mikromechanicznych stopu. Materiałem badań były korony ze stopu CoCrMo. Przeprowadzone badania pozwoliły stwierdzić, że szczelność koron protetycznych wykonanych w technologii tradycyjnego odlewania oraz w technologii frezowania i technologii SLM jest porównywalna i spełnia wymogi kliniczne. Analizy strukturalne koron potwierdziły bardzo dobrą jakość warstwy wierzchniej uzyskiwanej w technologii frezowania oraz w technologii SLM metodą CAD/CAM. SLM i frezowanie metodą cyfrową pozwalają na wytworzenie precyzyjnych i wytrzymałych konstrukcji stanowiących podbudowy koron w czasie znacznie krótszym niż proces odlewniczy.
The aim of the study was to conduct strength analysis of a knee joint in order to experimentally determine the destructive fatigue loading under the conditions of cyclic compression. Animal joints were used as the study material. They were periodically subjected to variable axial loading. The degree of joint deformity and damage to articular surfaces and menisci were globally determined after isolation of the joint structures. The application of the variant of axial loading without slip and rolling results in the rupture of the medial meniscus, which is an important biotribological structure. Fatigue testing of the joints allowed for the determination of the parameters of biomechanical extortions, which lead to the loss of normal lubrication conditions and the degradation of the meniscus and cartilage structures on the femoral condyles.
PL
Celem jest analiza wytrzymałościowa w stawie kolanowym, która pozwala na eksperymentalne wyznaczenie niszczącego obciążenia zmęczeniowego w warunkach cyklicznego ściskania. Materiałem badań były stawy zwierzęce. Poddano je okresowo zmiennym obciążeniom osiowym. Oceniano globalnie stopień deformacji stawu oraz stopień uszkodzeń powierzchni stawowych i łąkotek po separacji struktur stawowych. Wariant obciążeń osiowych bez realizacji poślizgu i przetaczania się prowadzi do pękania łąkotki przyśrodkowej, która stanowi odpowiedzialną strukturę biotribologiczną. Badania zmęczeniowe stawów pozwoliły przybliżyć parametry wymuszeń biomechanicznych, które powodują utratę prawidłowych warunków smarowania i degradację struktur łąkotek oraz chrząstki na kłykciach kości udowej.
Endoprosthesis stem fractures are among the rarest complications that occur after hip joint arthroplasty. The aim of this paper is to evaluate the causes of the fractures of the Aura II stem neck, which is an element of an endoprosthesis implanted in a patient. In order to achieve it, a radiogram was evaluated, the FEM analysis was carried out for the hip joint replaced using the Aura II prosthesis and scanning tests as well as a chemical analysis were performed for the focus of fatigue. The tests performed indicate that the most probable causes leading to the fatigue fracture of the Aura II stem under examination were material defects in the process of casting and forging (forging the material with delamination and the presence of brittle oxides and carbides) that resulted in a significant reduction of strength and resistance to corrosion. In the light of an unprecedented stem neck fracture, this information should be an indication for non-destructive tests of ready-made stems aiming to discover the material and technological defects that may arise in the process of casting and drop forging.
The functionality of a prosthesis is determined by clinical procedures, the manufacturing technology applied, the material used and its strength parameters. The aim of the paper is to evaluate the static strength and fatigue strength of acrylic construction materials directly after the process of polymerisation and for aged materials. It has been confirmed that the deformation speed of the tested materials has an evident impact on their mechanical characteristics.With greater deformation speed, a consistent increase in the material elasticity was observed in static compression tests, which was accompanied by a reduction in engineering stresses at the final stage of deformation. The greatest fatigue strength was observed for Vertex. It was by about 33% greater than the strength of Villacryl – the material that has the lowest fatigue properties. The resistance of acrylic polymers to cyclic loading applied with the frequency of 1 Hz may become an indication for the selection of the material to be used in the clinical procedures in which a patient is provided with full dentures.
Physiological abrasion of teeth is a process of gradual loss of the hard tissue of opposite teeth resulting from age-related natural dental wear. In abrasion, the cusps and their slopes in the jaw and the mandible become flattened due to the mechanical load applied. The aim of this paper is to carry out a tribological and microstructural evaluation of modern composite materials used to reconstruct the teeth in the lateral part of the dental arch. Five light-cured composite materials were selected for tests. The tests involved the coefficient of friction and resistance to wear in a sliding contact in the presence of artificial saliva and the microstructure of the external surface of samples before the wear process and in the wear-related damaged area. The test method applied, which combines a biomechanical analysis of resistance to wear and the analysis of the microstructure before the wear process and in the wear-related damaged area, makes it possible to evaluate the tribological properties of composite materials used to reconstruct teeth in the lateral part of the dental arch.
PL
Fizjologiczne starcie zębów jest to proces stopniowej utraty twardych tkanek zębów przeciwstawnych w wyniku naturalnego zużycia postępującego z wiekiem. Starcie to polega na jednoczesnym spłaszczaniu guzków i ich stoków w zębach szczęki i żuchwy w warunkach obciążeń biomechanicznych. Celem pracy jest ocena tribologiczna i mikrostrukturalna nowoczesnych materiałów kompozytowych stosowanych do odbudowy ubytków w bocznym odcinku łuku zębowego. Do badań wybrano 5 materiałów kompozytowych utwardzanych światłem. Przeprowadzono badania współczynnika tarcia i odporności na zużycie w kontakcie ślizgowym, w obecności sztucznej śliny oraz badania mikrostrukturalne warstwy wierzchniej próbek przed procesem zużycia oraz w strefie skazy zużyciowej. Zastosowana metoda badań łącząca biomechaniczną analizę odporności na zużycie z analizą mikrostruktury przed procesem zużycia oraz w skazie zużyciowej pozwala na ocenę właściwości tribologicznych materiałów kompozytowych do odbudowy zębów w bocznym odcinku łuku.
Hip replacement surgery, by introducing a specific replacement head on the stem and cup, completely changes the conditions of co-operation typical for the biological correct pair. The clinical selection of endoprosthesis, apart from other conditionings, involves a dilemma between the choice of a rigid tribological node and the selection of a susceptible bearing cushioning the locomotive loads. The aim of the study is to evaluate the coefficient of friction and wear resistance of materials used for sliding contact in the endoprostheses of hip joints. On the basis of the conducted tests, it can be stated that, in the selection of material for cups of endoprosthesis, the wear resistance is important, and the coefficient of friction in contact head and cup in the prosthesis is less important. The presence of significant disproportions between the two parameters of the tribological process proves that the biomaterial is less useful on the cup. In the assessment of cooperation in the endoprosthesis, simulations of the contact of structural elements are useful, because, on that basis, in the correlation with tribological parameters, one can make conclusions about the distribution of stresses and displacements that may determine the lifetime of the implant.
PL
Zabieg alloplastyki stawu biodrowego poprzez wprowadzenie określonej zamiennej głowy na trzpieniu i panewki zmienia całkowicie warunki współpracy charakterystyczne dla biologicznej prawidłowej pary. Kliniczny dobór endoprotezy, oprócz innych uwarunkowań, wiąże się z dylematem pomiędzy wyborem sztywnego węzła tribologicznego a wyborem biołożyska podatnego, amortyzującego obciążenia lokomocyjne. Celem pracy jest ocena współczynnika tarcia i odporności na zużycie materiałów stosowanych na panewki do kontaktu ślizgowego w endoprotezach stawu biodrowego. Na podstawie przeprowadzonych badań można stwierdzić, że w doborze materiału na panewkę endoprotezy ważna jest odporność na zużycie ścierne, a nieco mniejsze znaczenie ma współczynnik tarcia w kontakcie z głową endoprotezy. Występowanie znacznych dysproporcji między tymi dwoma parametrami procesu tribologicznego świadczy o słabszej przydatności biomateriału na panewki endoprotez. W ocenie współpracy w endoprotezie przydatne są symulacje kontaktu elementów konstrukcyjnych, ponieważ na ich podstawie, w korelacji z parametrami tribologicznymi, można wnioskować o rozkładach naprężeń i przemieszczeń, które będą decydować o żywotności implantu.
The latest method for creating denture replenishment in CAD / CAM systems is Direct Metal Laser Sintering (DMLS) technology. With the use of DMLS, prosthodontics, implant prosthetics, and facial-cranialjaw surgery adapted to individual patient conditions can be realized. The aim is to evaluate the strength, microstructure, and tribological properties of Ti6Al4V and CoCrMo alloys obtained from DMLS technology in the aspect of therapeutic constructions. The conducted tests show that, in the DMLS technology, as compared to milling technology preceded by casting and forging or pressed powder and sintering, for the same percentage composition of elements, the micromechanical properties, microstructural and tribological change. This procedure, from which constructions for various dental applications are obtained, is the new technology preferred for making permanent restorations faced with ceramics, producing intravascular implants, and implants of the temporomandibular joint. It can be an alternative to conventional cast-based methods and CAD / CAM based milling.
PL
Najnowszą metodą tworzenia uzupełnień stomatologicznych w systemie CAD/CAM jest technologia Direct Metal Laser Sintering (DMLS). Z wykorzystaniem DMLS można realizować wykonanie konstrukcji protetyki, implantoprotetyki oraz chirurgii twarzowo-czaszkowo-szczękowej dostosowanej do indywidualnych warunków pacjenta. Celem jest ocena parametrów wytrzymałościowych, mikrostruktury i właściwości tribologicznych stopów Ti6Al4V oraz CoCrMo uzyskanych w technologii DMLS w aspekcie zastosowania na konstrukcje terapeutyczne. Przeprowadzone badania wskazują, że w technologii DMLS, w porównaniu z technologią frezowania poprzedzoną procesami odlewania i kucia lub prasowania proszku i spiekania, dla tego samego składu procentowego pierwiastków, zmieniają się właściwości mikromechaniczne, mikrostrukturalne i tribologiczne. Procedura ta, w wyniku której uzyskuje się konstrukcje dla różnych aplikacji stomatologicznych – jest nową technologią preferowaną do wykonawstwa uzupełnień stałych licowanych ceramiką, do wytwarzania wszczepów śródkostnych oraz implantów stawu skroniowo-żuchwowego. Może ona stanowić alternatywę dla klasycznych metod opartych na odlewnictwie oraz metod CAD/CAM opartych na frezowaniu.
Posts are permanent, single-tooth and periodontal restorations. During chewing, forces make teeth with posts to undergo complex stresses. The aim of this work is to compare and estimate the upper medial incisors restored with custom posts and prefabricated composite posts reinforced with fibreglass using the finite element method. Modelling and numerical analyses provide the opportunity to evaluate the reconstruction of teeth using custom and prefabricated posts.
11
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Purpose: The aim of this study is to generate a global digital model of treatment, analysis of stress distribution and displacements: in a construction of the bracket, in the incisor with bonded bracket, in tissues of the incisor, in a periodontal membrane and in an alveolus. Methods: An orthodontic therapy was provided with a three-dimensional model of a unique Cannon Ultra bracket. The placement of the bracket to the incisor was provided according to clinical standards. Composite material was placed between the rough surface of the bracket's base and labial incisor surface – which, in a digital model, resulted in contact without displacement. The bracket was loaded. An orthodontic arch wire was free to move in a wing slot of the bracket. For simplification, a force vector was parallel to the longitudinal axis of the incisor. A clamper was set on the surface of the cortical bone of the alveolus. The model was divided into a finite number of tetrahedral elements. To calculate the distribution of stress Ansys Workbench software was used. Results: The stress values indicate that there were no tissue overloaded areas. The stress distribution was regular in the periodontal ligament. Slight movements were observed with maximal values in the area of apex. Conclusions: This study simulation proves that tissues surrounding the tooth were influ-enced mechanically by the force loaded on the bracket. [...]
Najnowszą technologią wykonywania konstrukcji protetycznych jest DLMS. Celem badań jest ocena tej technologii oraz technologii odlewania pod względem mikrostruktury oraz twardości stopu CoCrMo. Materiałem badań były próbki ze stopu SP2 wykonane technologią DLMS. Grupę kontrolną stanowiły próbki z Remanium GM 800+ z odlewania. Badania strukturalne wykonano na mikroskopie skaningowym. Pomiary twardości przeprowadzono metodą Vickersa. SP2 wykazał jednorodną budowę i skład chemiczny oraz twardość 629 HV. W Remanium GM 800+ zaobserwowano mikrosegregację dendrytyczną oraz porowatości, twardość wynosiła 513 HV. Można stwierdzić, że DMLS w aspekcie mikrostruktury i twardości jest technologią preferowaną na indywidualne konstrukcje dla protetyki.
13
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Celem opracowania była ocena in vitro szczelności koron ze stopu Co-Cr-Mo na zęby przedtrzonowe i trzonowe wykonanych w trzech technologiach: odlewania, frezowania i stapiania laserowego. Dla porównania dopasowania koron do filarów protetycznych stanowiących modele referencyjne wykorzystano skanowanie światłem strukturalnym i modelowanie w programie Geomagic Qualify 12. Badania pozwoliły stwierdzić, że szczelność koron protetycznych wykonanych w badanych technologiach jest porównywalna i spełnia wymogi kliniczne.
EN
The aim of the study was to assess the in vitro tightness crown alloy Co-Cr-Mo on the premolars and molars made in three technologies: casting, milling and laser melting. For comparison fitting crowns to the pillars of prosthetic on which the reference models used structured light scanning and modeling in the Geomagic Qualify 12. The study revealed that the tightness of the prosthetic crowns made in the tested technologies is comparable and meets the requirements of the clinical.
14
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W artykule przedstawiono aplikację wzorców kulowych oraz wzorców typu Ball Bar do oceny odwzorowania przy obrazowaniu CT medycznej. Celem jest ocena wybranych procedur dokładności odwzorowania kształtu i wymiarów z zastosowaniem certyfikowanych wzorców oraz zaproponowanie parametrów metrologicznych umożliwiających porównanie urządzeń diagnostycznych pod kątem aplikacji pomiarowych. Błędy odwzorowania geometrii mogą być identyfikowane na podstawie systemów kontrolnych wykorzystywanych w CT przemysłowej.
EN
The paper presents the application patterns of ball and patterns of the Ball Bar type to evaluate mapping with medical CT imaging. The aim is to evaluation the selected procedures for assessing the accuracy of mapping shape and dimensions of the use of certified standards and proposing metrological parameters for the comparison of diagnostic equipment for measurement applications. Geometry mapping errors can be identified on the basis of the control systems used in industrial CT.
15
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Wymogiem klinicznym dla stałych uzupełnień protetycznych jest takie projektowanie ich konstrukcji, aby w czasie funkcji żucia nie doprowadzały do urazowych przeciążeń. Celem jest analiza naprężeń i przemieszczeń, występujących w trakcie obciążenia zgryzowego w zespole zębowo-zębodołowym i strukturach kostnych żuchwy oraz zastosowanych w tym układzie mostach. Wizualizacja biomechaniczna modeli pozwoliła ocenić wzajemne relacje pomiędzy rozległością przęsła mostu a uwarunkowaniami anatomicznymi tkanek podłoża protetycznego.
EN
Clinical requirement for fixed restorations is the design of the construction to during chewing function do not lead to traumatic overload. The aim is to analyze the stresses and displacements that occur during loading the occlusal on the team dental-alveolar and the jaw bone structures and used in this system bridges. Biomechanical visualization to models allowed to assess interaction between the extent of the structure of the bridge and the determinants of tissue anatomical of prosthetics substrate.
16
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Anatomical structures are characterized by free surfaces, and most are in lobed and pseudo-spherical shapes. The aim of this article is to analyze selected procedures for accuracy assessment of the shape and dimensions of these structures using certified sphere and Ball Bar standards and to propose metrology parameters facilitating comparison of diagnostic devices. The spherical standard of various materials and Ball Bar standards with various distances between spheres centers can be a tool for evaluation of computed tomography metrology applications. Errors in geometry mapping can be identified on the basis of standardized control systems used in coordinate measuring techniques.
17
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
This study presents the use of endobronchial ultrasound (EBUS) for imaging and dimensional measurements of a trachea. An assessment of shape reproduction accuracy was based on a comparative method using oneand two-later models. It was found that dimensions determined from EBUS scans of digital models are overstated by 1.2–2.9 mm on average. Developed 2-D and 3-D models of tracheal structures facilitate the evaluation of dimensions and thickness distribution for tissue layers.
Laserowe spiekanie proszków metali (DMLS) jest nową technologią otrzymywania konstrukcji w procedurze CAD/CAM. Celem opracowania były identyfikacja strukturalna i wyznaczenie parametrów wytrzymałościowych tytanu oraz stopów tytanu przeznaczonych na podbudowy stałych uzupełnień protetycznych otrzymywanych przy komputerowym wspomaganiu projektowania i wytwarzania. Materiałem badań były próbki z czystego technicznie tytanu – gatunek 1 do wytworzenia konstrukcji w technologii obróbki frezowaniem oraz próbki Ti6Al4V z technologii laserowego, przyrostowego spiekania proszków. Wykonano badania mikrostrukturalne i mikromechaniczne. Na ich podstawie stwierdzono, że w aspekcie wytrzymałościowym DMLS jest technologią preferowaną do wykonawstwa stałych konstrukcji nośnych dla protetyki stomatologicznej i może stanowić alternatywę dla systemu CAD/CAM z obróbką ubytkową.
EN
A direct metal laser sintering method (DMLS) is a new technology used for getting structures by the CAD/CAM procedures. The aim of the elaboration was a question of structural identification and setting strength parameters of titanium (Ticp) and its alloy (Ti6Al4V) which are used to serve as base for those permanent prosthetic supplements which are later manufactured with the employment of CAD/CAM systems. The research work was performed on Ticp samples – those which were intended for manufacture of structures by decrement milling working, and Ti6Al4V samples that comes from laser increment sintering of powder. According to the results obtained, the following conclusion has been derived: when strength aspect is discussed, the DMLS method is a preferred one for manufacturing of load structures in dentistry and may be an alternate way for the CAD/CAM system used in decrement processing.
19
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Etiologia uszkodzeń chrząstki stawowej kolana jest wieloczynnikowa. Konsekwencją tych uszkodzeń jest chzs. Celem badań była rekonstrukcja przestrzenna oraz ocena dokładności odwzorowania ubytków tkanki chrzęstnej w stawie kolanowym z wykorzystaniem MR. Materiałem badań były stawy z ubytkami chrząstki szklistej w obszarze kłykci kości udowej. Opracowano metodę identyfikacji kształtu tych ubytków oraz technikę ich rekonstrukcji przestrzennych. Dokładność metody zweryfikowano w referencyjnych pomiarach współrzędnościowych.
EN
The etiology of the articular cartilage of the knee is multifactorial. The consequence of this damage is OA. The aim of the study was the reconstruction of spatial and evaluation of the accuracy of the mapping of cartilage defects in the knee joint using MR. The material tests were ponds with hyaline cartilage defects in the femoral condyle. Developed a method to identify the shape of these defects and the technique of spatial reconstruction. The accuracy of the method was verified in the reference coordinate measurements.
20
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Celem opracowania było wyznaczenie parametrów wytrzymałościowych tytanu i stopu tytanu przeznaczonych na podbudowy stałych uzupełnień protetycznych otrzymywanych przy komputerowym wspomaganiu projektowania i wytwarzania. Wykonano badania mikromechaniczne w których wyznaczono mikrotwardości i moduły sprężystości wzdłużnej. Na ich podstawie stwierdzono, że DMLS jest technologią preferowaną do wykonawstwa stałych konstrukcji nośnych dla protetyki stomatologicznej i może stanowić alternatywę dla systemu CAD/CAM z obróbką ubytkową.
EN
The aim of the elaboration was a question of setting strength parameters of titanium (Ticp) and its alloy (Ti6Al4V) which are used to serve as base for those permanent prosthetic supplements which are later manufactured with the employment of CAD/CAM systems. Micromechanical tests were performed in which the designated microhardness and Young's modules. According to the results obtained, the following conclusion has been derived: when strength aspect is discussed, the DMLS method is a preferred one for manufacturing of load structures in dentistry and may be an alternate way for the CAD/CAM system used in decrement processing.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.