Strengthening of cracked compressed masonry using different types of reinforcement located in the bed joints

Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
In engineering practice, the repair and strengthening of the cracked masonry is carried out in several different ways. In general practice it is normal for individual cracked bricks to be removed and replaced, reinforce the masonry by using bowstrings or anchors, stitch with bars or bond the brick by means of chemical injection. As only limited information and recommendations are available for strengthening cracked masonry, the method selected for a particular application is usually based upon local experience and engineering instinct. In this paper the investigations of strengthening vertically cracked compressed masonry wallettes with stitching bars of three different types are presented. The purpose of presented investigations was to check the effectiveness of strengthening in vertically cracked compressed masonry wallettes. The results of these investigations allow us to assess four ways of strengthening with respect of the obtained values of the compressive strengths and the modulus of elasticity of the masonry after repair.
PL
W praktyce inżynierskiej naprawy zarysowanych murów wykonuje się na kilka sposobów. Zazwyczaj stosuje się przemurowania zarysowanych obszarów, dozbrojenie za pomocą ściągów, zszycie rys przez układanie prętów w spoinach wspornych lub zespolenie muru przy pomocy iniekcji. Ze względu na ograniczoną ilość dostępnych informacji i zaleceń metoda wzmocnienia zarysowanych murów wybierana zwykle bywa na podstawie lokalnych doświadczeń wykonawczych i inżynierskiego wyczucia. W artykule przedstawiono wyniki badań zarysowanych murów wzmocnionych przez zszycie zarysowań trzema typami prętów zbrojeniowych. Celem prezentowanych badań było określenie efektywności wzmocnienia zarysowanych murów. Uzyskane na podstawie badań wartości wytrzymałości na ściskanie i modułu sprężystości wzmocnionego muru pozwoliły ocenić efektywność czterech sposobów zbrojenia.
Rocznik
Strony
39--48
Opis fizyczny
Bibliogr. 15 poz.
Twórcy
autor
autor
autor
  • Faculty of Civil Engineering, The Silesian University of Technology, Akademicka 5, 44-100 Gliwice, Poland, lukasz.drobiec@polsl.pl
Bibliografia
  • [1] Parkinson G., Shaw G., Beck J.K. Knowles, D.: Appraisal & repair of masonry, Thomas Telford Publishing, London, 1996
  • [2] Schubert P.: Mauerwerk. Risse vermeiden und instandsetzung, Fraunhofer IRB Verlag (Avoid and repair of cracks), Stuttgart, 2004, (in German)
  • [3] Freeman T.J., Littlejon G.S., Driscoll R.M.C.: Has your house got cracks? A guide to subsidence and heave of buildings on clay, Thomas Telford Publishing, London, 1994
  • [4] Brameshuber W., Beer I., Kang B.-G.: Untersuchungen zur Vermeidung von Riβschäden bei nicht tragenden Trennwänden (Investigations of repair methods of partition walls), Mauerwerksbau, Heft 1, 2007, pp.54-62, (in German)
  • [5] Drobiec L., Jasiński R., Kubica J.: Investigation of efficiency stitch boss on capacity of cracked masonry wallets. 12th International Brick/Block Masonry Conference, Madrid-Spain, 25-28 June 2000, pp. 953-970
  • [6] Cook D., Ring S.: The effective use of masonry reinforcement for crack repair. Proceedings of the British Masonry Society: Masonry 7, Proceedings of the Fourth International Masonry Conference, London, 1992, Vol. II , pp. 442-450
  • [7] D’ Ayala D.: The use of bed joint reinforcement to improve the performance of historic masonry buildings. Proceedings of the British Masonry Society: Masonry 8, Proceedings of the Fifth International Masonry Conference, London, 1995, pp. 320-326
  • [8] Atkinson R.H., Schuller M.P.: Injection grouting for the Repair of brick masonry. Conservation of historic brick structures. Case studies and reports of research. Donhead Publishing Ltd 1998, pp. 325-333
  • [9] PN-71/B-04500, Zaprawy budowlane. Badania cech fizycznych i wytrzymałościowych. Mortars. Research of physical and mechanical characteristics (Polish standard)
  • [10] EN 1015-11:1998, Methods of test for mortar for masonry - Part 11: Determination of flexural and compressive strength of hardened mortar. CEN, July 1998
  • [11] EN 772-1:2000, Methods of test for masonry units - Part 1: Determination of compressive strength. CEN, June 2000.
  • [12] PN-70/B-12016, Wyroby ceramiki budowlanej. Ceramicware. (Polish standard)
  • [13] EN 1052-1:1998 Methods of tests for masonry - Part 1: Determination of compressive strength. CEN, September 1998
  • [14] Sumon S.K.: Innovative retrofitted reinforcement techniques for masonry arch bridges. Proceedings of the Institution of Civil Engineers 2005, Bridge engineering, Vol.158, No 3, September 2005, pp.91-99
  • [15] Sumon S.K.: Repair and strengthening of tree-ring brick masonry arch bridges. Proceedings of the British Masonry Society: Masonry 10, Proceedings of the Seventh International Masonry Conference, London, 2006
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BSL2-0022-0110
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.