Narzędzia help

Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
first previous next last
cannonical link button

http://yadda.icm.edu.pl:80/baztech/element/bwmeta1.element.baztech-article-BPW8-0016-0046

Czasopismo

Przegląd Elektrotechniczny

Tytuł artykułu

How can the IRP p-q theory be applied for active filtering under nonsinusoidal voltage operation?

Autorzy Bitoleanu, A.  Popescu, M. 
Treść / Zawartość http://pe.org.pl/
Warianty tytułu
PL Jak teoria IRP p-q może być użyta do filtracji aktywnej w warunkach niesinusoidalnego napięcia?
Języki publikacji EN
Abstrakty
EN This paper presents an analysis of Akagi's p-q theory for active filtering under nonsinusoidal voltage conditions. It is ascertained that compensating the alternative parts of the instantaneous active and reactive powers leads to a sinusoidal power supply current only under sinusoidal voltage conditions. A modified definition of the active component of the current is proposed for operation under nonsinusoidal voltage conditions and shunt active filter applications. A generic example and the full controlled rectifier-based DC motor drive system are used as case studies.
PL Artykuł przedstawia analizę teorii p-q Akagi'ego, stosowanej do filtracji aktywnej w warunkach napięć niesinusoidalnych. Stwierdzono, że kompensacja składników oscylacyjnych mocy chwilowych, czynnej i biernej, prowadzi do sinusoidalnego prądu zasilania tylko w warunkach zasilania napięciem sinusoidalnym. Zaproponowano zmodyfikowaną definicję składowej czynnej prądu na potrzeby sterowania równoległego filtru aktywnego pracującego przy niesinusoidalnym napięciu zasilania. Prostownikowy napęd silnika prądu stałego został użyty w artykule jako przykład dla przedstawionej w artykule analizy.
Słowa kluczowe
PL teoria p-q   prąd aktywny   napięcie niesinusoidalne   filtracja aktywna  
EN p-q theory   active current   nonsinusoidal voltage   active filtering  
Wydawca Wydawnictwo SIGMA-NOT
Czasopismo Przegląd Elektrotechniczny
Rocznik 2011
Tom R. 87, nr 1
Strony 67--71
Opis fizyczny Bibliogr. 18 poz., rys.
Twórcy
autor Bitoleanu, A.
autor Popescu, M.
  • Electric Drivers and Industrial Informatics Department, Faculty for Electromechanical, Environmental and Industrial Informatics Engineering, University of Craiova, Romania, Decebal Bd. 107, 200440 Craiova, abitoleanu@em.ucv.ro
Bibliografia
[1] Nedelcu V.N., Die einheitliche leistungstheorie der unsymetrischen und mehrwelligen mehrphasensysteme, ETZ-A Elektrotech. Z., 84 (1963) No. 5, 153-157
[2] Nedelcu V.N., Electromechanical conversion theory, Technical Ed., Bucharest, 1978. (In Romanian)
[3] Akagi H. and Nabae A., The p-q theory in three-phase systems under non-sinusoidal conditions, European Trans. on Electrical Power, 3 (1993), No.1, 27-31
[4] Akagi H., New trends in active filters for power conditioning, IEEE Trans. Ind. Appl., 32 (1996), No. 6, 1312-1322
[5] Emanuel A.E., Powers in nonsinusoidal situations: A review of definitions and physical meaning, IEEE Trans. on Power Delivery, 5 (1990), No. 3, 1377-1389
[6] Emanuel A.E., On the definition of power factor and apparent power in unbalanced polyphase circuits with sinusoidal voltage and currents, IEEE Trans. on Power Delivery, 8 (1993), No. 3, 841-852
[7] Slonim M.A. and Van Wyk J.D, Power components in a system with sinusoidal and nonsinusoidal voltages and/or currents, Proc. IEE, 135 (1988) Issue 2, 76-84
[8] Willems J.L., Critical analysis of the concepts of instantaneous power currents and of active current, European Trans. on Electrical Power, 8 (1998), 271-274
[9] Willems J.L., Current compensation in three-phase power systems, European Trans. on Electrical Power, 3 (1993), Issue 1, 61 – 66
[10] Czarnecki L.S., On some misinterpretations of the instantaneous reactive power p-q theory, IEEE Trans. on Power Electronics, 19 (2004), No. 3, 828-836
[11] Czarnecki L.S., Orthogonal decomposition of the current in a three phase nonlinear asymmetrical circuit with nonsinusoidal voltage, IEEE Trans. on Instrum. Meas., IM-37 (1988), No. 1, 30–34
[12] Czarnecki L.S., Physical interpretation of the reactive power in terms of the CPC power theory, Electrical Power Quality and Utilisation Journal, XIII (2007), No. 1, 89-95
[13] Fryze S., Active, reactive, and apparent power in non-sinusoidal systems, Przeglad Elektrot., (1931), No. 7, 193-203. (In Polish)
[14] Ferrero A., Definitions of Electrical Quantities Commonly Used in Non-Sinusoidal Conditions, European Trans. on Electrical Power, 8 (1988), 235-240
[15] C.I. Budeanu, “Reactive and fictitious powers,” Inst. Romain de I’Energie, Bucharest, Rumania, 1927. (In Romanian)
[16] Popescu Mihaela, Bitoleanu A., Dobriceanu M., On the current decomposition based on instantaneous apparent power vector, Proc. of the Tenth IASTED International Conf. on Power and Energy Systems, Acta Press, Baltimore, 2008, 120-125
[17] Peng F.Z. and Tolbert L.M., Compensation of nonactive current in power systems - definitions from a compensation standpoint, IEEE Power Engineering Society Summer Meeting, July 15-20 (2000), Seattle, WA, 983-987
[18] Czarnecki L.S., Limitation of the IRP p-q Theory as Control Algoritm of Switching Compensators, 9th International Conference, Electrical Power Quality and Utilisation, Barcelona, 9-11 October 2007
Kolekcja BazTech
Identyfikator YADDA bwmeta1.element.baztech-article-BPW8-0016-0046
Identyfikatory