Tytuł artykułu

Application of the stationary DC decay test to industrial turbogenerator model parameter estimation

Autorzy Majka, Ł.  Szuster, D. 
Treść / Zawartość http://pe.org.pl/
Warianty tytułu
PL Zastosowanie testu zaniku prądu stałego do estymacji parametrów modelu turbogeneratora przemysłowego
Języki publikacji EN
Abstrakty
EN In the paper there is presented measurement-based model parameter estimation in both d and q axis of a synchronous generator. The tests were carried out while the machine was at standstill. This is an interesting measurement method, especially when other tests are difficult to be performed. Optimisation of the appropriately formulated objective function was used for determining the considered model parameters. MatlabSimulink package was used for computations.
PL W artykule przedstawiono wyniki pomiarowej estymacji parametrów w osi d i q modelu generatora. Testy pomiarowe przeprowadzono dla generatora znajdującego się na postoju. Jest to interesująca metoda pomiarowo-obliczeniowa, szczególnie kiedy inne testy są trudne lub niemożliwe do przeprowadzenia. Wyznaczenie parametrów zrealizowano w drodze optymalizacji odpowiednio sformułowanej funkcji celu. Do obliczeń wykorzystano pakiet Matlab-Simulink.
Słowa kluczowe
PL generator synchroniczny   modele matematyczne   estymacja parametrów   stany nieustalone  
EN synchronous generator   mathematical models   parameter estimation   transient states  
Wydawca Wydawnictwo SIGMA-NOT
Czasopismo Przegląd Elektrotechniczny
Rocznik 2014
Tom R. 90, nr 4
Strony 242--245
Opis fizyczny Bibliogr. 10 poz., il., schem., tab., wykr.
Twórcy
autor Majka, Ł.
  • Silesian University of Technology, Faculty Of Electrical Engineering, Institute of Industrial Electrical Engineering and Informatics, ul. Akademicka 10, 44-100 Gliwice, lukasz.majka@polsl.pl
autor Szuster, D.
  • Silesian University of Technology, Faculty Of Electrical Engineering, Institute of Industrial Electrical Engineering and Informatics, ul. Akademicka 10, 44-100 Gliwice, dominik.szuster@polsl.pl
Bibliografia
[1] Paszek S.: Selected methods for assessment and improvement of power system angular stability. Silesian University of Technology Publishing House, Gliwice, 2012. (in Polish)
[2] Majka Ł., Paszek S.: Use of hybrid algorithm for estimation of generating unit mathematical model parameters. Electrical Review, No. 8, 2010, pp. 70-76. (in Polish)
[3] Boboń A., Paszek S., Pasko M., Pruski. P., Bojarska M. : Parameter estimation of different synchronous generator models obtained from measurement tests. Electrical Review, No. 2b/2013, pp. 116-119. (in Polish)
[4] Berhausen S., Paszek S.: Estimation of electromagnetic parameters of synchronous generator with electromechanical excitation system working in power system. Electrical Machines - Transaction Journal, No. 87/2010, pp. 95-98. (in Polish)
[5] Berhausen S., Paszek S.: Measurement estimation of synchronous generator parameters based on the waveforms under load conditions. XXXVI International Conference on Fundamentals of Electrotechnics and Circuit Theory, ICSPETO' 2013, Ustroń, May 2013, pp. 83-84. (in Polish)
[6] Tumageanian A., Keyhani A., Moon S.I., Leksan T. I., Xu L.: Maximum likelihood estimation of synchronous machine parameters from flux decay data. IEEE Transactions on Industry Applications, Vol. 30, Apr. 1994, pp. 433–439.
[7] Turner P.J., Reece A.B.J., MacDonald D.C.: The DC decay test for determining synchronous machine parameters: measurement and simulation. IEEE Transactions on Energy Conversion, Vol. 4, No. 4, Dec 1989, pp. 616-623
[8] IEEE Standard: Guide for synchronous generator modeling practices and applications in power system stability analyses. IEEE Std 1110-2002, Nov. 2003.
[9] Sellschopp F.S., Arjona M.A.: DC decay test for estimating d-axis synchronous machine parameters: a twotransfer-function approach. IEE Proceedings - Electric Power Applications, Vol. 153, No. 1, Jan. 2006, pp. 123-128.
[10] Boboń A., Berhausen S., Szuster D.: Determination of synchronous generator parameters on the basis of transient waveforms calculated by the finite element method. XVII International Symposium on Electric Machinery in Prague, ISEM'2009, 9-10 Sep 2009, Prague, pp.8-13.
Kolekcja BazTech
Identyfikator YADDA bwmeta1.element.baztech-42466746-0547-4602-96a6-4dba5ac8251b
Identyfikatory
DOI 10.12915/pe.2014.04.59